Invert:12 VDC120V, 60 Hz. AC
Charge:120V, 60 Hz. AC12 VDC
Quiet Mobile Power
Congratulations! You’ve purchased the most advanced, feature-rich Inverter/Charger designed for recreational vehicle applications. Tripp Lite
RV Inverter/Chargers are the quiet alternative to gas generators—with no fumes, fuel or noise to deal with! You get AC electricity anywhere
and anytime you need it: rolling down the highway, dry camping in majestic back country or parked overnight at a money-saving non-electric
site. RV Inverter/Chargers provide your equipment with utility- or generator-supplied AC electricity (filtered through premium ISOBAR®surge
protection) whenever available. In addition, your RV Inverter/Charger automatically powers your RV’s 12V system and recharges your connected
battery bank—doing what traditional RV converter/chargers do. Whenever power blackouts, brownouts or high voltages occur, your RV
Inverter/Charger immediately and automatically switches over to inverting battery output to power connected AC equipment.
Better for Your EquipmentPremium Protection Levels
• Built-In ISOBAR®Surge Protection
• Automatic Overload Protection
1111 W. 35th Street, Chicago, IL 60609 USA
Customer Support: (773) 869-1234
www.tripplite.com
Ideal Output for All Loads (including computers)
• Frequency-Controlled Output
• Fast Load Switching
• Balanced Load Sharing*
Better for Your BatteriesFaster Battery Recharge
• High-Amp, 3-Stage Battery Charger (adjustable)
Critical Battery Protection
• Battery Charge Conserver (Load Sense)*
• Battery Temperature Sensing*
• High-Efficiency DC-to-AC Inversion
Better for YouQuiet, Simple, Maintenance-Free Operation
• Multi-Function Lights & Switches
• Automatic Generator Starting*
• Moisture-Resistant Construction
†
Contents
Specifications/Warranty2
Safety3
Battery Selection8
Mounting9
Feature Identification4
Operation5
Configuration6-7
* Available on all models except 612 models. †Inverter/Chargers are moisture-resistant, not waterproof.
is a registered trademark of Tripp Lite. All rights reserved.
two 4164 (fuse blocks)two 4164 (fuse blocks)
(fuse blocks)
4164
(fuse block)two
two 4164 (fuse block)4164
(fuse block)
4164
(fuse block)
Note on Labeling Two symbols are used on the RV labels.
V~: AC Voltage V: DC Voltage
DC Input Volts (Nominal):12 VDC • · DC Input Voltage Range: 10 - 15 VDC • Output Volts (Nominal): 120 VAC, ± 5% • Output Frequency (Nominal): 60 Hz, ± 0.5% • Efficiency: 88% to 94%, depending on load and temperature
Specifications
MODEL NUMBER:RV612ULRV612ULHRV1012ULRV1012ULHWRV1512ULRV1512OEMRV2012ULRV2012OEMRV2512OEMRV3012OEM
Series Number:AGAP60012MVJAGAP60012MVJAGAP100012MV3AGAP100012MV3AGAP200012MV3AGAP200012MVP3AGAP200012MV3AGAP200012MVP3
AC Input Connection:Input CordHardwireInput CordHardwireHardwireHardwireHardwireHardwireHardwireHardwire
INVERTER
Common Specifications for All Models: •
Select Tripp Lite Inverter/Chargers include a Battery Charge Conserver (Load Sense) Control which saves battery power by allowing users to set the minimum load level at which the unit’s
inverter turns on. Users can significantly reduce the No Load DC Input Current (approximately 1 to 3 A for all models) to a very low amp level with the use of this control.
Continuous Power (@ 20 C):60060010001000150015002000200025003000
(Transfer to Battery)105 VAC105 VAC95 or 105 VAC95 or 105 VAC95 or 105 VAC95 or 105 VAC95 or 105 VAC95 or 105 VAC95 or 105 VAC95 or 105 VAC
Maximum Input AC Current 11.3 A14.5 A12 A20 A35 A35 A38 A40 A44 A37 A
†
Minimum Recommended Cable Sizing Chart
(Continuous, Charger
at Maximum):
Maximum Bypass AC Current:6 A6 A12 A12 A20 A20/20 A20 A20/20 A20/20 A20/20 A
(Load circuit breaker limited)
* OverPower duration (up to 1 hour). DoubleBoost duration (up to 10 seconds). Actual duration depends on battery age, battery charge level and ambient temperature. **Factory setting. The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.
2R
Twin 00 (2/0)
Wire Gauge
Inverter/Charger DC Volt: 12
Use in conjunction with DC wiring connection instructions in the Battery Connection section.
N/R = Not Recommended. NOTE: Acceptable power is directly related to cable length (i.e. - the shorter the cable, the better the performance)
3000N/RN/RN/R10 ft13 ft26 ft.
†
Limited Warranty
Tripp Lite warrants its Inverter/Chargers to be free from defects in materials and workmanship for a 30 month period from the date of retail purchase by end user.
Tripp Lite’s obligation under this warranty is limited to repairing or replacing (at its sole option) any such defective products.To obtain service under this warranty you must obtain a Returned Material Authorization (RMA) number from Tripp Lite or an authorized Tripp Lite service center.Products must be returned to Tripp Lite or an author-
ized Tripp Lite service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty does not apply to equipment which has been damaged by accident, negligence or misapplication or has been altered or modified
in any way, including opening of the unit’s casing for any reason.This warranty applies only to the original purchaser who must have properly registered the product within 10 days of retail purchase.
EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s)
may not apply to the purchaser.
EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, Tripp Lite is not liable for any
costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise.
Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
Important Safety Instructions
SAVE THESE INSTRUCTIONS!
This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite
Inverter/Chargers.
Location Warnings
• Install your Inverter/Charger (whether for a mobile or stationary application) in a location or compartment that minimizes exposure to
heat, dust, direct sunlight and moisture.
• Although your Inverter/Charger is moisture resistant, it is NOT waterproof. Flooding the unit with water will cause it to short circuit
and could cause personal injury due to electric shock. Never immerse the unit, and avoid any area where standing water might
accumulate. Mounting should be in the driest location available.
• Leave a minimum of 2" clearance at front and back of the Inverter/Charger for proper ventilation. To avoid automatic Inverter/Charger
shutdown due to overtemperature, any compartment that contains the Inverter/Charger must be properly ventilated with adequate
outside air flow. The heavier the load of connected equipment, the more heat will be generated by the unit.
• Do not install the Inverter/Charger directly near magnetic storage media, as this may result in data corruption.
• Do not install near flammable materials, fuel or chemicals.
Battery Connection Warnings
• The Inverter/Charger will not operate (with or without utility power) until batteries are connected.
• Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type.
• Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be
installed (whether for a mobile or stationary application) in a “dead air” compartment. Ideally, any compartment would have some
ventilation to outside air.
• Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.
• Do not allow objects to contact the two DC input terminals. Do not short or bridge these terminals together. Serious personal injury
or property damage could result.
Equipment Connection Warnings
Do not use a Tripp Lite RV Inverter/Charger in life support or healthcare applications where a malfunction or failure of a
Tripp Lite RV Inverter/Charger could cause failure of, or significantly alter the performance of, a life support device or
medical equipment.
• Corded models: Do not modify the Inverter/Charger’s plug or receptacle in a way that eliminates its ground connection. Do not use
power adapters that will eliminate the plug’s ground connection.
• Connect your Inverter/Charger only to a properly grounded AC power outlet or hardwired source. Do not plug the unit into itself; this
will damage the device and void your warranty.
• You may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to the output of
the Inverter/Charger.
Operation Warnings
• Your Inverter/Charger does not require routine maintenance. Do not open the device for any reason. There are no user serviceable parts inside.
• Potentially lethal voltages exist within the Inverter/Charger as long as the battery supply and/or AC input are connected. During any
service work, the battery supply and AC input connection (if any) should therefore be disconnected.
• Do not connect or disconnect batteries while the Inverter/Charger is operating in either inverting or charging mode. Operating Mode
Switch should be in the OFF position. Dangerous arcing may result.
3R
Feature Identification
HOT IN
NEUTRAL IN
GROUND IN
GROUND OUT
HOT OUT
“FOR USE WITH COPPER WIRE ONLY”
NEUTRAL OUT
Identify the premium features on your specific model and quickly locate instructions on how to maximize their use.
The “AUTO/REMOTE” setting ensures your equipment
receives constant, uninterrupted AC power. It also enables the
Inverter/Charger to be remotely monitored and controlled with
an optional remote module (Tripp Lite model APSRM2, sold
separately or included with select models). The “CHARGE
ONLY” setting allows your batteries to return to full charge faster
by turning the inverter off which halts battery discharging. See
page 5 for setting instructions.
show whether the Inverter/Charger is operating from AC line
power or DC battery power. It also warns you if the connected
equipment load is too high. See page 5 for instructions on
reading indicator lights.
4
Battery Indicator Lights: intuitive “traffic light” signals show
approximate charge level of your battery. See page 5 for
instructions on reading indicator lights.
5
DC Power Terminals: connect to your battery terminals. See
page 10 for connection instructions.
6
Ground Fault Interrupter (GFI) AC Receptacles (not on
hardwire models): allow you to connect equipment that would
normally be plugged into a utility outlet. They feature ground
fault interrupter switches that trip if there is excessive current
on the ground safety wire.
7
AC Input Cord (not on hardwire models): connects the
Inverter/Charger to any source of utility- or generator-supplied
AC power. See page 11 for connection instructions.
8
Hardwire AC Input/Output Terminals (not on corded
models): securely connect the Inverter/Charger to vehicle or
facility electrical system input and recommended GFCI receptacle
output. See page 11 for connection instructions.
9
Resettable Circuit Breaker: protect your Inverter/Charger against
damage due to overload. See page 5 for resetting instructions.
10
Remote Control Module Connector: allows remote monitoring
and control with an optional module (Tripp Lite model
APSRM2, sold separately or included with select models). See
remote module owner’s manual for connection instructions.
11
Battery Charge Conserver (Load Sense) Dial (not on 612
models): conserves battery power by setting the low-load level
at which the Inverter/Charger’s inverter automatically shuts off.
See page 7 for setting instructions.
12
Main Ground Lug: properly grounds the Inverter/Charger to
vehicle grounding system or to earth ground. See page
10 for connection instructions.
13
Multi-Speed Cooling Fan: quiet, efficient fan prolongs equipment
service life.
14
DC Power Terminal Cover Plate
15
Hardwire AC Input/Output Cover Plate
16
Battery Temperature Sensing Connector (not on 612 models):
prolongs battery life by adjusting charge based on battery temperature. Use with cable (included on select models). See page
7 for details.
17
Automatic Generator Start Connector (not on 612 models):
automatically cycles generator based on battery voltage. Use
with user-supplied cable. See page 7 for details.
14
Front View (Corded Models)
* 612 models have only one set of DIP Switches. ** Select models include front-mounted ground lug. † Available on all models except 612 models.
5
12
Front View (Dual Input/Output Hardwire Models)
13
5
1
13
4
1*10
7
10
3
4
3
2
†
11
†
Side Mounted,
16
Not Shown
†
Side Mounted,
17
Not Shown
9
6
**
12
2
11
16
17
9
8
13
14
Front View (Single Input/Output Hardwire Models)
12
Rear View (Single Input/Output Hardwire Models and Select Corded Models)
4R
1
5
10
8
243
15
11
16
17
9
Side Mounted,
Not Shown
Side Mounted,
Not Shown