Tripp SUINT2200LCD2U Product Data Sheet

SmartOnline 208/230V 2.2kVA 1.98kW Double­Conversion UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9, ENERGY STAR
MODEL NUMBER: SUINT2200LCD2U
High-performance on-line double-conversion UPS with interactive LCD interface ideal for any critical voice, data, medical or industrial IT application. Converts AC input to DC and then fully regulated sine wave AC power.
Description
Highlights
Zero transfer time suitable for advanced network applications
2% output voltage regulation in online and battery modes
Selectable 200/208/220/230/240V output voltage
Meets strict ENERGY STAR efficiency guidelines
11.7 min. runtime at half load;
4.3 min. at full load
Package Includes
SUINT2200LCD2U SmartOnline 2200VA/1980W On-Line Double-Conversion UPS
4-post rack-mount installation kit
USB cable
RS-232 cable
C19-to-C20 power cable
(2) C13-to-C14 power cables
Owner’s manual
In case of AC power outage, the internal batteries support 11.7 minutes of runtime at half load and 4.3 minutes at full load. Extended runtime is possible with optional external battery packs. “Smart” battery packs, such as Tripp Lite’s BP48V27-2US, are automatically sensed and configured during replacement. An intelligent battery management system extends battery life.
Managing the UPS is simplified through the interactive front-panel LCD interface, which displays operating conditions and diagnostic data, such as load and battery levels. You can set power strategies to reflect your protection priorities, whether it’s precise power quality for sensitive systems or the highest possible electrical efficiency, all while ensuring 100% uptime for your systems.
Power is filtered to protect connected equipment against surges and EMI/RFI line noise that can damage equipment or destroy data. Adding an optional Tripp Lite network management accessory card permits remote management of the UPS, including reboots and activity logs.
Features
1 / 6
Protects Mission-Critical Rack-Mounted Equipment
Converts AC input to DC power, then DC to fully regulated sine wave AC output
+/-2% voltage regulation in online and battery modes
Selectable 200/208/220/230/240V output voltage
2200VA/1980W capacity
1 C19 and 8 C13 outlets
936-joule surge suppression rating
Interactive Front-Panel LCD
Reports detailed status information, including load and battery levels
Offers advanced configuration options, including output voltage and power strategies
5 Power Strategies
Auto Adaptive enables high efficiency and high-quality operation as necessary for ideal equipment protection
Max Efficiency favors economy operation with high 95% efficiency
Max Quality favors on-line double-conversion mode, maintaining +/-2% output voltage regulation and zero transfer time
Frequency Regulation and Frequency Conversion enable +/-0.05 Hz output regulation for selected frequency (50/60 Hz)
Reliable, Expandable Battery Backup
Supports half load for 11.7 min. and full load for 4.3 min.
Add external battery packs for extra runtime
“Smart” battery packs, such as Tripp Lite’s BP48V27-2US, are automatically sensed and configured during replacement
Full capacity available with and without external battery packs
Battery-independent restart ensures automatic power-up after lengthy power outages
Highly Customizable
Customize communications and behavior to integrate with device makers’ specific needs
Selectable auto-restart from 0 to 60 sec. after AC power is restored
Selectable minimum battery charge level before auto-restart
Schedule system reboot if USB signal from connected device is lost
Set overload thresholds and low battery levels for alert and shutdown
Remote on/off support via DB9
ENERGY STAR Certification
Saves money and energy and protects environment by meeting strict EPA efficiency guidelines
2 / 6
Network Management Card Options / USB & Serial Ports
Compatible Tripp Lite UPS management card options WEBCARDLX and SNMPWEBCARD support a wide variety of UPS control and monitoring capabilities
USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert
Specifications
OUTPUT
Output Volt Amp Capacity (VA) 2200 Output kVA Capacity (kVA) 2.2 Output Watt Capacity (Watts) 1980 Output kW Capacity (kW) 1.98 Output Capacity Details DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 1386 watts for
Power Factor 0.9 Crest Factor 3:1 Nominal Output Voltage(s)
Supported Nominal Voltage Details Nominal output voltage is user configured on first power-on Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion
Output Voltage Regulation (Line Mode)
Output Voltage Regulation (Economy Line Mode)
Output Voltage Regulation (Battery Mode)
Output Receptacles (8) C13; (1) C19 Included Output Power Cables Includes 2 C13 to C14 and 1 C19 to C20 power cables
208/220/230/240V output voltages; Max output is 1584W (1108W in Frequency Conversion mode) at 200V output voltage
OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).
200V; 208V; 220V; 230V; 240V
operation
+/- 2%
+/- 10%
+/- 2%
Load Management Receptacles Two switchable outlet load banks (Bank 1: 3 C13 outlets / Bank 2: 1 C19 + 3 C13 outlets) Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery
Mode)
INPUT
Pure Sine wave
3 / 6
Rated input current (Maximum Load) 10.94A Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC UPS Input Connection Type C20 inlet Input Phase Single-Phase
BATTERY
Full Load Runtime (min.) 4.3 min. (1980w) Half Load Runtime (min.) 11.7 min. (990w) Expandable Battery Runtime Supports extended runtime with optional external battery packs External Battery Pack Compatibility  <a class="productLink" href="//www.tripplite.com/External-48V-2U-Rack-Tower-Battery-Pack-Enclosure-DC-
Cabling-select-UPS-Systems-BP48V24-2U~BP48V24-2U">BP48V24-2U</a> (limit 1);  <a class="productLink" href="//www.tripplite.com/External-48V-2U-Rack-Tower-Battery-Pack-for-UPS-Systems­BP48V27-2US~BP48V27-2US">BP48V27-2US</a> (multi-pack compatible);  <a class="productLink" href="//www.tripplite.com/External-48V-3U-Rack-Tower-Battery-Pack-Enclosure-DC-Cabling-select-UPS-Systems-
BP48V60RT-3U~BP48V60RT-3U">BP48V60RT-3U</a> (multi-pack compatible) DC System Voltage (VDC) 48 Battery Recharge Rate (Included
Batteries) Internal UPS Replacement Battery
Cartridge
Less than 3.0 hours from 10% to 90% (typical, full load discharge)
 <a class="productLink" href="//www.tripplite.com/Replacement-Battery-Cartridge-Select-48V-Tripp-Lite-
SmartOnline-UPS-Systems~RBC48S">RBC48S</a>  Battery Access Front panel battery access door Battery Replacement Description Hot-swappable, replaceable batteries Expandable Runtime Yes
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning Overvoltage Correction 2% output voltage regulation during overvoltages to 288V Undervoltage Correction 2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load)
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Interactive front-panel LCD interface reports UPS operating mode, detailed UPS status and site-power information;
LCD interface also enables a variety of advanced UPS setup and configuration options Switches 5 front panel switches: On/Off, Up, Down and Escape Alarm Cancel Operation Power-fail alarm can be silenced by following on-screen prompts Audible Alarm Audible alarm indicates power failure, low battery, overload and fault LED Indicators 4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red)
SURGE / NOISE SUPPRESSION
UPS Dataline Suppression Details Single line dialup / network dataline protection included EMI / RFI AC Noise Suppression Yes AC Suppression Joule Rating 936
4 / 6
AC Suppression Response Time Instantaneous
PHYSICAL
Included Mounting Accessory Description
Installation Form Factors Supported with Included Accessories
Installation Form Factors Supported with Optional Accessories
4 post installation accessories included
4 post 19 inch rackmount
2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)
Primary Form Factor Rackmount UPS Power Module Dimensions
(hwd, in.) UPS Power Module Dimensions
(hwd, cm)
3.46 x 17.24 x 19.53
8.79 x 43.79 x 49.61
Rack Height (U Spaces) 2 Minimum Required Rack Depth
(inches)
26
Minimum Required Rack Depth (cm) 66.04 UPS Power Module Weight (lbs.) 50.94 UPS Power Module Weight (kg) 23.11 Shipping Dimensions (hwd / in.) 9.450 x 22.240 x 27.560 Shipping Dimensions (hwd / cm) 24.00 x 56.49 x 70.00 Shipping Weight (lbs.) 60.0000 Shipping Weight (kg) 27.22 Cooling Method Fan UPS Housing Material Metal Primary UPS Height (mm) 879 Primary UPS Width (mm) 4,379 Primary UPS Depth (mm) 4,961
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius. Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius. Relative Humidity 5 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 675 AC Economy Mode BTU / Hr. (Full
Load)
356
Battery Mode BTU / Hr. (Full Load) 1012 AC Mode Efficiency Rating (100%
Load)
>90%
5 / 6
AC Economy Mode Efficiency Rating (100% Load)
Audible Noise <50dB at front side 1M
COMMUNICATIONS
Communications Interface USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface Network Management Cards SNMPWEBCARD; WEBCARDLX
>95%
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at
Communications Cable USB and DB9 cabling included WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer Time No transfer time (0 ms.) in online, double-conversion mode; 2-12 ms. transfer time during economy mode operation Low Voltage Transfer to Battery
Power (Setpoint) High Voltage Transfer to Battery
Power (Setpoint)
SPECIAL FEATURES
Grounding Lug Back panel grounding lug included Cold Start (Startup in Battery Mode
During a Power Failure) High Availability UPS Features Automatic inverter bypass; Hot swappable batteries Green Energy-Saving Features High efficiency economy mode operation; Individually controllable load banks
CERTIFICATIONS
http://www.tripplite.com/poweralert
160V (100% load), 140V (66% load), 120V (33% load)
288V
Cold-start operation supported
UPS Certifications CE; ENERGY STAR Qualified; Tested to CSA (Canada); Tested to EAC (Belarus, Kazakhstan, Russia); Tested to
UPS Certification Details IEC62040-1:2008+A1; UL1778 5th; Meets EMI approvals IEC62040-2:2006; FCC Part 15
WARRANTY
Product Warranty Period (Worldwide)
SASO (Saudi Arabia); Tested to UL1778 (USA)
2-year limited warranty
© 2018 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies: https://www.tripplite.com/products/product-certification-agencies
6 / 6
Loading...