SmartOnline 208/230V 2.2kVA 1.98kW DoubleConversion UPS, 2U, Extended Run, Network
Card Options, LCD, USB, DB9, ENERGY STAR
MODEL NUMBER: SUINT2200LCD2U
High-performance on-line double-conversion UPS with interactive LCD interface ideal for any critical
voice, data, medical or industrial IT application. Converts AC input to DC and then fully regulated sine
wave AC power.
Description
The SUINT2200LCD2U SmartOnline® 2200VA/1980W On-Line Double-Conversion UPS converts AC
input to DC power, and then converts DC to fully regulated sine wave AC output with +/-2% voltage
regulation in online and battery modes. ENERGY STAR certification saves you money by meeting strict
EPA guidelines. An interactive front-panel LCD interface provides detailed real-time UPS status and
advanced setup and configuration options.
Highlights
●
Zero transfer time suitable for
advanced network applications
●
2% output voltage regulation in
online and battery modes
In case of AC power outage, the internal batteries support 11.7 minutes of runtime at half load and 4.3
minutes at full load. Extended runtime is possible with optional external battery packs. “Smart” battery
packs, such as Tripp Lite’s BP48V27-2US, are automatically sensed and configured during replacement.
An intelligent battery management system extends battery life.
Managing the UPS is simplified through the interactive front-panel LCD interface, which displays operating
conditions and diagnostic data, such as load and battery levels. You can set power strategies to reflect
your protection priorities, whether it’s precise power quality for sensitive systems or the highest possible
electrical efficiency, all while ensuring 100% uptime for your systems.
Power is filtered to protect connected equipment against surges and EMI/RFI line noise that can damage
equipment or destroy data. Adding an optional Tripp Lite network management accessory card permits
remote management of the UPS, including reboots and activity logs.
Features
1 / 6
Protects Mission-Critical Rack-Mounted Equipment
●
Converts AC input to DC power, then DC to fully regulated sine wave AC output
●
+/-2% voltage regulation in online and battery modes
●
Selectable 200/208/220/230/240V output voltage
●
2200VA/1980W capacity
●
1 C19 and 8 C13 outlets
●
936-joule surge suppression rating
Interactive Front-Panel LCD
●
Reports detailed status information, including load and battery levels
●
Offers advanced configuration options, including output voltage and power strategies
5 Power Strategies
●
Auto Adaptive enables high efficiency and high-quality operation as necessary for ideal equipment
protection
●
Max Efficiency favors economy operation with high 95% efficiency
●
Max Quality favors on-line double-conversion mode, maintaining +/-2% output voltage regulation and
zero transfer time
●
Frequency Regulation and Frequency Conversion enable +/-0.05 Hz output regulation for selected
frequency (50/60 Hz)
Reliable, Expandable Battery Backup
●
Supports half load for 11.7 min. and full load for 4.3 min.
●
Add external battery packs for extra runtime
●
“Smart” battery packs, such as Tripp Lite’s BP48V27-2US, are automatically sensed and configured
during replacement
●
Full capacity available with and without external battery packs
●
Battery-independent restart ensures automatic power-up after lengthy power outages
Highly Customizable
●
Customize communications and behavior to integrate with device makers’ specific needs
●
Selectable auto-restart from 0 to 60 sec. after AC power is restored
●
Selectable minimum battery charge level before auto-restart
●
Schedule system reboot if USB signal from connected device is lost
●
Set overload thresholds and low battery levels for alert and shutdown
●
Remote on/off support via DB9
ENERGY STAR Certification
●
Saves money and energy and protects environment by meeting strict EPA efficiency guidelines
2 / 6
Network Management Card Options / USB & Serial Ports
●
Compatible Tripp Lite UPS management card options WEBCARDLX and SNMPWEBCARD support a
wide variety of UPS control and monitoring capabilities
●
USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert
software, available via FREE download from www.tripplite.com/poweralert
Specifications
OUTPUT
Output Volt Amp Capacity (VA)2200
Output kVA Capacity (kVA)2.2
Output Watt Capacity (Watts)1980
Output kW Capacity (kW)1.98
Output Capacity DetailsDE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 1386 watts for
Power Factor0.9
Crest Factor3:1
Nominal Output Voltage(s)
Supported
Nominal Voltage DetailsNominal output voltage is user configured on first power-on
Frequency Compatibility50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility DetailsOutput frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation
(Economy Line Mode)
Output Voltage Regulation (Battery
Mode)
Output Receptacles(8) C13; (1) C19
Included Output Power CablesIncludes 2 C13 to C14 and 1 C19 to C20 power cables
208/220/230/240V output voltages; Max output is 1584W (1108W in Frequency Conversion mode) at 200V output
voltage
OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for
30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are
WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).
200V; 208V; 220V; 230V; 240V
operation
+/- 2%
+/- 10%
+/- 2%
Load Management ReceptaclesTwo switchable outlet load banks (Bank 1: 3 C13 outlets / Bank 2: 1 C19 + 3 C13 outlets)
Output AC Waveform (AC Mode)Pure Sine wave
Output AC Waveform (Battery
Voltage Regulation DescriptionOnline, double-conversion power conditioning
Overvoltage Correction2% output voltage regulation during overvoltages to 288V
Undervoltage Correction2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load)
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD DisplayInteractive front-panel LCD interface reports UPS operating mode, detailed UPS status and site-power information;
LCD interface also enables a variety of advanced UPS setup and configuration options
Switches5 front panel switches: On/Off, Up, Down and Escape
Alarm Cancel OperationPower-fail alarm can be silenced by following on-screen prompts
Audible AlarmAudible alarm indicates power failure, low battery, overload and fault
LED Indicators4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red)
SURGE / NOISE SUPPRESSION
UPS Dataline Suppression DetailsSingle line dialup / network dataline protection included
EMI / RFI AC Noise SuppressionYes
AC Suppression Joule Rating936
4 / 6
AC Suppression Response TimeInstantaneous
PHYSICAL
Included Mounting Accessory
Description
Installation Form Factors Supported
with Included Accessories
Installation Form Factors Supported
with Optional Accessories
4 post installation accessories included
4 post 19 inch rackmount
2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)
Primary Form FactorRackmount
UPS Power Module Dimensions
(hwd, in.)
UPS Power Module Dimensions
(hwd, cm)
3.46 x 17.24 x 19.53
8.79 x 43.79 x 49.61
Rack Height (U Spaces)2
Minimum Required Rack Depth
(inches)
26
Minimum Required Rack Depth (cm)66.04
UPS Power Module Weight (lbs.)50.94
UPS Power Module Weight (kg)23.11
Shipping Dimensions (hwd / in.)9.450 x 22.240 x 27.560
Shipping Dimensions (hwd / cm)24.00 x 56.49 x 70.00
Shipping Weight (lbs.)60.0000
Shipping Weight (kg)27.22
Cooling MethodFan
UPS Housing MaterialMetal
Primary UPS Height (mm)879
Primary UPS Width (mm)4,379
Primary UPS Depth (mm)4,961
ENVIRONMENTAL
Operating Temperature Range+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
Storage Temperature Range+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
Relative Humidity5 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)675
AC Economy Mode BTU / Hr. (Full
Communications InterfaceUSB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
Network Management CardsSNMPWEBCARD; WEBCARDLX
>95%
PowerAlert SoftwareFor local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at
Communications CableUSB and DB9 cabling included
WatchDog CompatibilitySupports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer TimeNo transfer time (0 ms.) in online, double-conversion mode; 2-12 ms. transfer time during economy mode operation
Low Voltage Transfer to Battery
Power (Setpoint)
High Voltage Transfer to Battery
Power (Setpoint)
SPECIAL FEATURES
Grounding LugBack panel grounding lug included
Cold Start (Startup in Battery Mode
During a Power Failure)
High Availability UPS FeaturesAutomatic inverter bypass; Hot swappable batteries
Green Energy-Saving FeaturesHigh efficiency economy mode operation; Individually controllable load banks