SMARTONLINE
3-PHASE UPS SYSTEMS
The Most Reliable and Cost-Effective Power Solutions for Your Data Center
SUPPORT
UP TO
160 KVA IN
PARALLEL
SMARTONLINE MODULAR 3-PHASE (40 – 80 KVA)
IDEAL OUTPUT POWER
PROTECTS CRITICAL SYSTEMS
MODULAR ARCHITECTURE
ELIMINATES DOWNTIME
1:1 GENERATOR SIZING
LOWERS INSTALLATION COSTS
EXTREME EFFICIENCY
LOWERS OPERATING COSTS
SMARTONLINE 3-PHASE (20 – 30 KVA)
RELIABLE OPERATION
KEEPS EQUIPMENT POWERED
COMPACT FOOTPRINT
SAVES FACILITY FLOOR SPACE
VERSATILE BATTERY SYSTEM
EXPANDS RUNTIME OPTIONS
SMARTONLINE MODULAR 3-PHASE UPS SYSTEMS
Extremely efficient protection for your most important equipment
IDEAL OUTPUT POWER
PROTECTS CRITICAL SYSTEMS
On-line, double conversion operation continuously
delivers precision-regulated, pure sine wave output,
isolating your critical systems from damaging and
disruptive power problems.
MODULAR ARCHITECTURE
ELIMINATES DOWNTIME
Internal N+1 power module redundancy, 1+1 parallel
capability and fault-tolerant bypass features keep your
critical systems highly available and productive around
the clock.
1:1 GENERATOR SIZING
LOWERS INSTALLATION COSTS
An advanced IGBT rectifier produces best-in-class
<4% THDi (input current Total Harmonic Distortion),
eliminating costly over-sizing requirements for
generators, breakers and cables.
EXTREME EFFICIENCY
LOWERS OPERATING COSTS
Efficiency up to 96% significantly lowers power and
cooling costs compared to multiple smaller units
or legacy high-capacity units.
SmartOnline Modular 3-Phase UPS Systems contain up to four intelligent,
independent 20 kVA power modules that support internal N+1 redundancy. If any
power module goes offline, the load is distributed among the remaining modules
and your equipment continues to operate without interruption. The UPS systems
also support a 1+1 parallel configuration to increase fault tolerance or double
output capacity (up to 160 kVA).
CONTENTS
SMARTONLINE
MODULAR
3-PHASE UPS
SYSTEMS
SU80K
208Y/120 VAC
80 kVA / 64 kW
SU80KTV
480Y/277 VAC
80 kVA / 64 kW
SU60K
208Y/120 VAC
60 kVA / 48 kW
SU60KTV
480Y/277 VAC
60 kVA / 48 kW
SU40K
208Y/120 VAC
40 kVA / 32 kW
IDEAL OUTPUT POWER 4
MODULAR
PARALLEL
1:1 GENERATOR
EXTREME
GREEN
MONITORING AND CONTROL
BATTERY
COMPACT
ORDERING
TECHNICAL
WARRANTIES AND SERVICES
ARCHITECTURE 4
FEATURES 4
SIZING 5
EFFICIENCY 5
POWER 5
6
CABINETS 6
FOOTPRINT 7
INFORMATION 7
SPECIFICATIONS 8
12
2
SMARTONLINE 3-PHASE UPS SYSTEMS
Reliable protection for small and mid-range installations
RELIABLE OPERATION
KEEPS EQUIPMENT POWERED
On-line operation and fault-tolerant bypass
features keep your equipment powered at all
times—even if the UPS system requires
maintenance, repair or replacement.
COMPACT FOOTPRINT
SAVES FACILITY FLOOR SPACE
The all-in-one design packs enough power for
multiple racks of equipment into a compact
footprint that saves precious floor space for
critical systems and cooling.
VERSATILE BATTERY SYSTEM
EXPANDS RUNTIME OPTIONS
A hot-swappable battery system with convenient
front-panel access allows you to customize battery
backup runtime through internal and/or external
expansion.
SmartOnline 3-Phase UPS Systems are available in standard and
extended-runtime configurations. The power module and expandable
internal battery system are combined in a single compact footprint.
Runtime can also be increased by connecting one or more external
battery cabinets.
CONTENTS
SMARTONLINE
3-PHASE
UPS SYSTEMS
SU30K3/3
208Y/120 VAC
30 kVA / 24 kW
SU30K3/3XR5
208Y/120 VAC
30 kVA / 24 kW
SU20K3/3
208Y/120 VAC
20 kVA / 16 kW
SU20K3/3XR5
208Y/120 VAC
20 kVA / 16 kW
3
RELIABLE OPERATION 9
COMPACT
VERSATILE
MONITORING AND CONTROL
ORDERING
TECHNICAL
WARRANTIES AND SERVICES
FOOTPRINT 9
BATTERY SYSTEM 9
10
INFORMATION 10
SPECIFICATIONS 11
12
tter C b n t U attery Cabinet UPS S
SMARTONLINE MODULAR 3-PHASE UPS SYSTEMS
IDEAL OUTPUT POWER
SmartOnline Modular 3-Phase UPS Systems
isolate your critical equipment from power
problems, including surges, line noise,
harmonic distortion, electrical impulses,
frequency variations, brownouts, overvoltages
and blackouts. True on-line operation
continually transforms AC input power into
filtered DC power, then resynthesizes it into
precision-regulated AC output with a pure
sine wave. Strong overload capacity supports
up to 150% output for up to 60 seconds.
Reliable backup power with zero transfer time
to battery keeps equipment operating safely
through shorter power failures and allows
time to shut down or switch to generator
power during longer outages. Rapid
recharging restores battery charge levels in
as little as two hours.
MODULAR ARCHITECTURE
Intelligent, independent 20 kVA power
modules provide internal redundancy. When
the UPS is configured for N+1 redundancy,
convenient hot-swap power modules can
be replaced without powering down the
connected load. In the event of a power
module fault, the load is automatically
distributed among the remaining modules.
Because load redistribution happens without
interrupting critical systems, mean time to
recovery is zero—far superior to legacy UPS
systems. In addition, redundant control circuits
eliminate a single point of failure commonly
found in less reliable UPS designs.
If service or repair requires UPS shutdown,
a manual bypass breaker and automatic
bypass function maintain system availability
by passing through AC power until the UPS
system returns to service.
PARALLEL FEATURES
Increase fault tolerance or double output
capacity by connecting two SmartOnline
Modular 3-Phase UPS Systems in a 1+1
parallel configuration. If one UPS is taken
offline for maintenance, the other UPS
automatically compensates to support the
equipment load—without requiring additional
programming.*
UPS systems ship ready for parallel operation
and patented dual-DSP technology provides
optimal synchronization of power sources.
* Each UPS system must be configured to support ≤ 50% of the
total load to provide redundancy in a 1+1 parallel configuration.
INTERNAL N+1 REDUNDANCY
20 kVA
Power Module
20 kVA
Power Module
20 kVA
Power Module
20 kVA
Power Module
20 kVA
Redundancy
60 kVA
Load
External Battery Cabinet 80 kVA UPS System
In an N+1 configuration, the supported load is at least 20 kVA less than the maximum output capacity of the UPS system.
For example, an 80 kVA UPS is configured for N+1 redundancy when the connected load is 60 kVA or less.
1+1 PARALLEL REDUNDANCY
50% Support 50% Support
80 kVA
Load
External
Battery Cabinet
Two 80 kVA SmartOnline Modular 3-Phase UPS Systems can provide redundant backup power for an 80 kVA load.
80 kVA
UPS System
External
Battery Cabinet
80 kVA
UPS System
1+1 PARALLEL CAPACITY DOUBLING
100% Support 100% Support
160 kVA
Load
External
Battery Cabinet
Two 80 kVA SmartOnline Modular 3-Phase UPS Systems can provide non-redundant backup power for a 160 kVA load.
4
80 kVA
UPS System
External
Battery Cabinet
80 kVA
UPS System