Tripp SU20KX Product Data Sheet

®
SMARTONLINE
3-PHASE UPS SYSTEMS
The Most Reliable and Cost-Effective Power Solutions for Your Data Center
SUPPORT
UP TO
160 KVA IN
PARALLEL
SMARTONLINE MODULAR 3-PHASE (40 – 80 KVA)
IDEAL OUTPUT POWER
PROTECTS CRITICAL SYSTEMS
MODULAR ARCHITECTURE
1:1 GENERATOR SIZING
LOWERS INSTALLATION COSTS
EXTREME EFFICIENCY
LOWERS OPERATING COSTS
SMARTONLINE 3-PHASE (20 – 30 KVA)
RELIABLE OPERATION
KEEPS EQUIPMENT POWERED
COMPACT FOOTPRINT
SAVES FACILITY FLOOR SPACE
VERSATILE BATTERY SYSTEM
EXPANDS RUNTIME OPTIONS
SMARTONLINE MODULAR 3-PHASE UPS SYSTEMS
Extremely efficient protection for your most important equipment
IDEAL OUTPUT POWER
PROTECTS CRITICAL SYSTEMS
On-line, double conversion operation continuously delivers precision-regulated, pure sine wave output, isolating your critical systems from damaging and disruptive power problems.
MODULAR ARCHITECTURE
ELIMINATES DOWNTIME
Internal N+1 power module redundancy, 1+1 parallel capability and fault-tolerant bypass features keep your critical systems highly available and productive around the clock.
1:1 GENERATOR SIZING
LOWERS INSTALLATION COSTS
An advanced IGBT rectifier produces best-in-class <4% THDi (input current Total Harmonic Distortion), eliminating costly over-sizing requirements for generators, breakers and cables.
EXTREME EFFICIENCY
LOWERS OPERATING COSTS
Efficiency up to 96% significantly lowers power and cooling costs compared to multiple smaller units or legacy high-capacity units.
SmartOnline Modular 3-Phase UPS Systems contain up to four intelligent,
independent 20 kVA power modules that support internal N+1 redundancy. If any power module goes offline, the load is distributed among the remaining modules and your equipment continues to operate without interruption. The UPS systems also support a 1+1 parallel configuration to increase fault tolerance or double output capacity (up to 160 kVA).
CONTENTS
SMARTONLINE MODULAR 3-PHASE UPS SYSTEMS
SU80K
208Y/120 VAC 80 kVA / 64 kW
SU80KTV
480Y/277 VAC 80 kVA / 64 kW
SU60K
208Y/120 VAC 60 kVA / 48 kW
SU60KTV
480Y/277 VAC 60 kVA / 48 kW
SU40K
208Y/120 VAC 40 kVA / 32 kW
IDEAL OUTPUT POWER 4
MODULAR
PARALLEL
1:1 GENERATOR
EXTREME
GREEN
MONITORING AND CONTROL
BATTERY
COMPACT
ORDERING
TECHNICAL
WARRANTIES AND SERVICES
ARCHITECTURE 4
FEATURES 4
SIZING 5
EFFICIENCY 5
POWER 5
6
CABINETS 6
FOOTPRINT 7
INFORMATION 7
SPECIFICATIONS 8
12
2
SMARTONLINE 3-PHASE UPS SYSTEMS
Reliable protection for small and mid-range installations
RELIABLE OPERATION
KEEPS EQUIPMENT POWERED
On-line operation and fault-tolerant bypass features keep your equipment powered at all times—even if the UPS system requires maintenance, repair or replacement.
COMPACT FOOTPRINT
SAVES FACILITY FLOOR SPACE
The all-in-one design packs enough power for multiple racks of equipment into a compact footprint that saves precious floor space for critical systems and cooling.
VERSATILE BATTERY SYSTEM
EXPANDS RUNTIME OPTIONS
A hot-swappable battery system with convenient front-panel access allows you to customize battery backup runtime through internal and/or external expansion.
SmartOnline 3-Phase UPS Systems are available in standard and
extended-runtime configurations. The power module and expandable internal battery system are combined in a single compact footprint. Runtime can also be increased by connecting one or more external battery cabinets.
CONTENTS
SMARTONLINE 3-PHASE UPS SYSTEMS
SU30K3/3
208Y/120 VAC 30 kVA / 24 kW
SU30K3/3XR5
208Y/120 VAC 30 kVA / 24 kW
SU20K3/3
208Y/120 VAC 20 kVA / 16 kW
SU20K3/3XR5
208Y/120 VAC 20 kVA / 16 kW
3
RELIABLE OPERATION 9
COMPACT
VERSATILE
MONITORING AND CONTROL
ORDERING
TECHNICAL
WARRANTIES AND SERVICES
FOOTPRINT 9
BATTERY SYSTEM 9
10
INFORMATION 10
SPECIFICATIONS 11
12
tter C b n t U attery Cabinet UPS S
EL RE
SMARTONLINE MODULAR 3-PHASE UPS SYSTEMS
IDEAL OUTPUT POWER
SmartOnline Modular 3-Phase UPS Systems isolate your critical equipment from power problems, including surges, line noise, harmonic distortion, electrical impulses, frequency variations, brownouts, overvoltages and blackouts. True on-line operation continually transforms AC input power into filtered DC power, then resynthesizes it into precision-regulated AC output with a pure sine wave. Strong overload capacity supports up to 150% output for up to 60 seconds. Reliable backup power with zero transfer time to battery keeps equipment operating safely through shorter power failures and allows time to shut down or switch to generator power during longer outages. Rapid recharging restores battery charge levels in as little as two hours.
MODULAR ARCHITECTURE
Intelligent, independent 20 kVA power modules provide internal redundancy. When the UPS is configured for N+1 redundancy, convenient hot-swap power modules can be replaced without powering down the connected load. In the event of a power module fault, the load is automatically distributed among the remaining modules. Because load redistribution happens without interrupting critical systems, mean time to recovery is zero—far superior to legacy UPS systems. In addition, redundant control circuits eliminate a single point of failure commonly found in less reliable UPS designs.
If service or repair requires UPS shutdown, a manual bypass breaker and automatic bypass function maintain system availability by passing through AC power until the UPS system returns to service.
PARALLEL FEATURES
Increase fault tolerance or double output capacity by connecting two SmartOnline Modular 3-Phase UPS Systems in a 1+1 parallel configuration. If one UPS is taken offline for maintenance, the other UPS automatically compensates to support the equipment load—without requiring additional programming.*
UPS systems ship ready for parallel operation and patented dual-DSP technology provides optimal synchronization of power sources.
* Each UPS system must be configured to support 50% of the total load to provide redundancy in a 1+1 parallel configuration.
INTERNAL N+1 REDUNDANCY
20 kVA
Power Module
20 kVA
Power Module
20 kVA
Power Module
20 kVA
Power Module
20 kVA
Redundancy
60 kVA
Load
External Battery Cabinet 80 kVA UPS System
In an N+1 configuration, the supported load is at least 20 kVA less than the maximum output capacity of the UPS system.
For example, an 80 kVA UPS is configured for N+1 redundancy when the connected load is 60 kVA or less.
1+1 PARALLEL REDUNDANCY
50% Support 50% Support
80 kVA
Load
External
Battery Cabinet
Two 80 kVA SmartOnline Modular 3-Phase UPS Systems can provide redundant backup power for an 80 kVA load.
80 kVA
UPS System
External
Battery Cabinet
80 kVA
UPS System
1+1 PARALLEL CAPACITY DOUBLING
100% Support 100% Support
160 kVA
Load
External
Battery Cabinet
Two 80 kVA SmartOnline Modular 3-Phase UPS Systems can provide non-redundant backup power for a 160 kVA load.
4
80 kVA
UPS System
External
Battery Cabinet
80 kVA
UPS System