Tripp SU16KRTHW Product Data Sheet

NETWORK/SERVER UPS
SmartOnline
®
Hot-Swappable UPS Systems (12 to 20 kVA)
MAXIMIZE AVAILABILITY
You invest in UPS systems to maintain system availability, but
the wrong UPS system will actually cause downtime. Traditional
UPS systems typically require you to power down equipment
for an hour or more during UPS maintenance and repair.
You may even need to disconnect your equipment and hire a
repair technician to rewire power connections before you can
ON-LINE DOUBLE CONVERSION
• Parallel Hot-Swappable Power Modules
• Built-in N+1 Redundancy
• Best-in-Class Energy Efficiency
• High Output Power Factor (0,9)
• Industrial Overload Capacity
• Wide Input Voltage Range
• Pure Sine Wave Output
• Scalable Runtime
Tripp Lite’s SmartOnline Hot-Swappable UPS Systems
maximize uptime, simplify maintenance and reduce service
expenses. You can remove one or both power modules without
powering down your equipment or hiring repair technicians.
The detachable PDU remains connected to your AC source and
your equipment, maintaining system availability without any
interruption to normal operation.
Remove the Power Modules… …And Your Equipment Stays On
SmartOnline Hot-Swappable UPS Systems allow you to remove both power modules without powering down your equipment.
SmartOnline Hot-Swappable UPS Systems Eliminate Downtime!
Traditional UPS System (5+ kVA)
Schedule Downtime (Typically After Hours) Hours to Days
Wait for UPS Repair Technician 4 to 24 hours
Shut Down and Disconnect Equipment 10+ minutes
Disconnect and Remove Old UPS 15 minutes
Install New UPS in Rack and Power Up 20 minutes
Plug In, Start Up and Test Equipment 15+ minutes
SmartOnline Hot-Swappable UPS System (5+ kVA)
Schedule Downtime Not Required
Wait for UPS Repair Technician Not Required
Turn Bypass Switch and Detach PDU 1 minute
Remove Old Power Module 1,5 minutes
Install New Power Module 1,5 minutes
Reattach PDU and Turn Bypass Switch 1 minute
Estimated Time to Repair 5 to 25+ hours
Estimated System Downtime 60+ minutes
Estimated Time to Repair 5 minutes
Estimated System Downtime Zero
NETWORK/SERVER UPS
PROVIDE BUILT-IN REDUNDANCY
SmartOnline Hot-Swappable UPS Systems automatically
provide N+1 redundancy when the equipment load is
the UPS capacity. If one of the parallel power modules requires
maintenance, repair or replacement, equipment still receives
perfect power and battery backup from the redundant power
module. If the equipment load is > 50% of the UPS capacity,
the parallel power modules work together to support the
heavier load.
50% of
SAVE ENERGY AND REDUCE COSTS
SmartOnline Hot-Swappable UPS Systems provide exceptional
energy efficiency. For each 80 kVA of on-line UPS capacity,
SmartOnline Hot-Swappable UPS Systems can save more than
100 megawatt-hours of electricity and USD $10 000 per year
while reducing CO2 emissions by nearly 70 metric tons.*
* The estimate compares a SmartOnline Hot-Swappable UPS System operating at 96% efficiency in Economy Mode to a traditional on-line UPS system operating at 86% efficiency. The calculations assume a 24x7 duty cycle and estimated electricity cost of USD $0,10 per kilowatt-hour. Savings vary with application and actual electricity cost.
SUPPORT HEAVIER LOADS
A high output power factor (0,9) allows you to connect more
equipment to the UPS and better utilize your facility’s existing
circuits and space. Industrial-grade overload capacity supports
higher inrush currents at equipment startup and fluctuating
power demands during operation without interrupting
production lines. SmartOnline Hot-Swappable UPS Systems
handle overloads up to 150% for brief periods and transfer
to bypass dynamically to sustain productivity during higher
overloads for extended periods.
SUPPLY PERFECT POWER
On-line operation with continuous double conversion
corrects input voltages as low as 100 V and as high as 300 V.*
SmartOnline Hot-Swappable UPS Systems deliver pure sine
wave output, regulate output voltage within 2% of nominal,
regulate frequency within 0,1% of nominal and comply
with international standards for voltage- and frequency-
independent operation.**
* Input voltage range is 156 to 280 V at 100% load, plus 281 to 300 V at 90% load and 100 to 155 V with linear derating to 50% load at 100 V. ** Voltage- and frequency-independent (VFI-SS-111) operation complies with EN 62040-3:2001.
CENTRALIZE POWER MANAGEMENT
SmartOnline Hot-Swappable
UPS Systems connect to the
network through the optional
SNMPWEBCARD accessory
or through a networked
computer connected to the
built-in USB or serial port.
The included PowerAlert
Network Management System (NMS) allows you to manage
hundreds of networked UPS systems and PDUs over the
network.
PowerAlert Software
INCREASE RUNTIME
The included hot-swappable batteries provide sufficient
backup runtime to support uninterrupted operation during
typical outages. For applications or adverse power conditions
that require additional runtime, you can connect as many
external battery packs as you need.
Estimated Battery Backup Runtime
Connected Equipment Load
Model
12 kVA UPS (Included Batteries)
12 kVA UPS and (2) BP192V12-3U
16 kVA UPS (Included Batteries)
16 kVA UPS and (2) BP240V10RT3U
20 kVA UPS (Included Batteries)
20 kVA UPS and (2) BP240V10RT3U
Runtime varies with load, temperature, battery condition and other factors. Visit www.tripplite.com for additional runtime options.
2 kW 4 kW 6 kW 8 kW 10 kW 12 kW 14 kW 16 kW 18 kW
29 min 12 min 7 min 4,5 min 2,8 min
133 min 59 min 36 min 25 min 18 min
80 min 35 min 20 min 13 min 11 min 8,4 min 6,7 min
184 min 84 min 52 min 36 min 27 min 21 min 17 min
80 min 35 min 20 min 13 min 11 min 8,4 min 6,7 min 4,9 min 4,3 min
184 min 84 min 52 min 36 min 27 min 21 min 17 min 17 min 14 min