Tripp PDUMV32HVNETLX Product Data Sheet

7.4kW Single-Phase Switched PDU w/LX Platform Interface, 230V Output, IEC 309 32A Blue, 10 ft. Cord, 0U, TAA
MODEL NUMBER: PDUMV32HVNETLX
Highlights
20 C13 and 4 C19 230V outlets distribute clean power to connected rack equipment
Built-in Java-free HTML5-based LX Platform interface allows you 24/7 remote access
Remote power monitoring and control reduces on-site visits and maintenance costs
10 ft. power cord with IEC 309 32A Blue (2P+E) input connects to compatible AC source
Digital ammeter for on-site load monitoring helps prevent power overloads
0U PDU distributes, monitors and manages single-phase power in an IT or industrial environment.
Features
0U PDU Distributes, Monitors and Manages Network-Grade AC Power
Recommended for data centers, server rooms and network closets, this 0U vertical PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. You can more efficiently manage network power consumption and properly balance loads without having to visit the site. Reducing the number of on-site visits can help lower the cost of data center maintenance.
24 Outlets Dispense Clean Power
During normal operation, 24 individually controllable outlets—20 C13 and four C19—distribute AC power to connected equipment. Each 230V outlet is accompanied by an LED that illuminates when the outlet is ramped up and ready to be used. The outlets are split into two load banks, each protected by a circuit breaker that trips if the bank’s connected load exceeds its maximum load rating. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.
Digital Load Meter Helps Prevent Potentially Expensive Overloads
A digital ammeter reports the load for each outlet bank separately and the total connected load. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. The firmware can be easily upgraded to ensure the PDU continues to perform at its best as connected equipment adds new features.
Built-In LX Platform Network Management Card Allows Remote Access 24/7
The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The 0U PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.
Easy to Install Vertically in an EIA-Standard 19 in. Rack
The 0U PDU mounts vertically using the included toolless mounting buttons or the included brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with
Applications
Powering a data center with server racks running mission­critical applications
Monitoring power loads from various computers, switches, servers and other networking equipment
Maintaining a computer network in a commercial or industrial facility
Package Includes
PDUMV32HVNETLX 7.4kW Single-Phase Switched PDU
(24) Plug-lock insert sleeves
Rack-mounting hardware
Spare mounting buttons
PDUMVROTATEBRKT mounting bracket accessory
Owner’s manual
1 / 3
outlets facing the rear for better airflow or equipment access. A 10-foot cord with IEC 309 32A Blue (2P+E) input plug connects the single-phase PDU to a compatible AC power source, generator or protected UPS system.
TAA-Compliant for GSA Schedule Purchases
The PDUMV32HVNETLX is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases.
2-Year Warranty
The PDUMV32HVNETLX is backed by a 2-year warranty, ensuring reliability and performance.
Specifications
OVERVIEW
UPC Code 037332202352 PDU Type Switched
OUTPUT
Output Capacity Details 7.7kW (240V), 7.4kW (230V), 7kW (220V), 6.7kW (208V), 6.4kW (200V) / 32A total capacity; 16A max per
Frequency Compatibility 50 / 60 Hz Output Receptacles (20) C13; (4) C19 Output Nominal Voltage 230 Overload Protection Two 20A circuit breakers protect 12 outlets each Customized Load Management
Receptacles
INPUT
PDU Input Voltage 230 Recommended Electrical Service 32A 230V Maximum Input Amps 32.0 PDU Plug Type IEC-309 32A BLUE (2P+E) Input Cord Length (ft.) 10 Input Cord Length (m) 3.05 Input Phase Single-Phase
USER INTERFACE, ALERTS & CONTROLS
breakered outlet bank; 16A max per C19 outlet; 10A max per C13 outlet
Each outlet is individually controllable via remote interface
Front Panel LCD Display Digital display reports output amps in 3 separately metered loading segments (BANK 1: Outlets #1-12; BANK 2:
Front Panel LEDs 24 power availability LEDs confirm power off/on status for each built-in outlet Switches Pushbutton control scrolls visual load meter display from bank 1, bank 2 and band 1&2 combined
Outlets #13-24; BANK 3: All outlets combined)