Management Interface
The management interface for this PDU model is transitioning to a new technology platform. The new
interface can be distinguished by a USB-A port (for EnviroSense2 modules) in place of the round
ENVIROSENSE port. For managing the units containing the round port, Tripp Lite recommends using the
PowerAlert Console Launcher rather than a web browser. This application enables local access of the
PDU using a self-contained, compatible Java Runtime Environment version. The Console Launcher can
be downloaded for free; click the above link or go to the Management Solutions / Utilities page. Units with
the new interface work will with most current web browsers.
3.7kW Single-Phase 230V ATS/Monitored PDU
with LX Platform Interface, IEC309 16A Blue
Outlet, 2 IEC309 16A Blue Inputs, 1U Rack-Mount
MODEL NUMBER: PDUMNH16HVAT
Highlights
●
Two IEC309 16A Blue (2P+E)
inputs with 10 ft. cords
●
IEC309 16A Blue outlet (2P+E)
for connecting device or 0U
PDU
●
Automatic transfer switching
within 1–5 ms
●
Built-in LX Platform network
interface for remote access
●
Digital display with LEDs for
real-time status monitoring
Package Includes
●
PDUMNH16HVAT 3.7kW
Single-Phase 230V
ATS/Monitored PDU
●
Rack-mounting brackets
●
Owner’s manual
High-capacity 3.7kW PDU with ATS provides remote power monitoring and enables redundant power for
non-redundant hardware. Digital display and Ethernet interface allow load monitoring to prevent overloads
that cause downtime.
Description
The PDUMNH16HVAT 3.7kW Single-Phase 230V ATS/Monitored PDU provides remote power monitoring
and enables redundant power for network devices with non-redundant power supply configurations. Ideal
for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has an
IEC309 16A Blue outlet for connecting a single device or a 0U 230V vertical PDU with IEC309 16A Blue
plug.
Dual 10-foot input cords with IEC309 16A Blue plugs connect to separate primary and secondary singlephase power sources, including out-of-phase sources. The PDU constantly evaluates the power quality of
both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to
the secondary source within 1–5 milliseconds if the primary source fails or becomes unstable to ensure
connected equipment remains powered.
Built-in LX Platform network management interface card. The Java-free LX Platform HTML5-based
network interface enables full remote access for PDU status monitoring and email notifications via secure
web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication
with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of
environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1,
SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. Digital display with LEDs indicates power
availability, voltage, input status for both power sources, output load and power factor, as well as
temperature and humidity conditions with optional ENVIROSENSE2 module (sold separately).
1 / 4
Features
Primary and Secondary Inputs for Power Redundancy
●
Offers remote power monitoring and enables redundant power for network devices with non-redundant
power supply configurations
●
IEC309 16A Blue (2P+E) inputs with 10 ft. cords connect to separate primary and secondary singlephase power sources
●
Fault-tolerant, hot-swappable UPS protection when used with single UPS; fully redundant UPS
protection when each cord is connected to a separate UPS
Built-In IEC309 16A Blue Outlet
●
Powers a single device or indirectly powers equipment through a 0U 230V PDU with IEC309 16A Blue
input (sold separately)
Automatic Transfer Switching
●
Dynamic solid-state (TRIAC) automatic transfer switching
●
Switches to secondary power source if primary source fails or becomes unstable
●
1–5 ms transfer time ensures uninterrupted operation of connected equipment
●
Built-in processor monitors power sources and prevents switching if secondary source is unavailable or
of lower quality than primary source
Multifunction Digital Display with LEDs
●
Reports input status for primary and secondary power sources, power availability, line voltage,
frequency, amps, kilowatts and power factor
Advanced Network Monitoring
●
LX Platform interface allows full remote access for power monitoring with email notifications via secure
web browser, SNMP, telnet or SSH
●
Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring
capabilities
Broad Communications Compatibility
●
HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
●
10/100 Mbps auto-sensing for communication with 10/100 Base-T networks
Mounts Horizontally in 1U of Rack Space
●
Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
●
Optional PDU4PKIT rail kit (sold separately) adds rear mounting support
Specifications
OVERVIEW
PDU Type Monitored; Auto-Transfer Switch
2 / 4