Congratulations on your purchase of the Triplett GSM350 Carbon
Monoxide/Carbon Dioxide IAQ Meter The GSM350 simultaneously
displays CO, CO2, Temperature and Humidity. The meter has a real-time
clock, datalogs and has user settable alarms for CO/CO2.
Long press the ON/OFF Button to boot and shutdown.
of Time, Battery Power, CO, CO2, Temperature and Humidity in
real time, CO will begin a sensor warm up period of 30 seconds
and then will start to measure.
Click the Left Button to enter the setup page, you can set the
Language, Temperature unit switch, data sampling settings,
automatic shutdown settings, alarm settings, brightness
adjustment, time settings.
Short pressof the Right Button will enter the CO, CO2
temperature and humidity and MAX/MIN/AVG mode.
Press theEnter/Rec Button to enter the history data query
interface.
MAX/MIN/AVG Mode
In this mode, the real-time data, maximum,
minimum and average values for CO, CO2,
Temperature and Humidity is displayed
Short press Right Button pauses the
reading.
Short press Left Button switches the
display page, so that CO, CO2, Temperature
and Humidity can be switched in order
Press the Return Button to return to the main page.
User Interface allows for the custom setting of Language,
Temperature Unit, Data Log sampling rates, Auto Power Off time,
Alarm settings, Brightness adjustment, and time settings.
Short press Left/Right Button can move
cursor, Left Button,
cursor moves up; Right Button corresponds
to cursor moves down.
press the Enter Button to enter the
corresponding setting interface.
Language Setup
Use the cursor to move to the desire language setting.
Short press the Enter Button to enter
the language setting.
Short press Enter Button again to
confirm and return to the setting interface, so that the Chinese
and English interface can be switched.
Unit, (°C or °F) press the Enter Button
to enter the temperature unit setting.
Short press the Enter button to
confirm and return to the settings interface
Datalogger Setup
to move to the
Datalogger settings, Press the Enter Button to enter the data sampling
setting interface, The sampling rate,
duration, and sleep mode can be set here.
duration setting is completed, the meter will automatically shut
down (when the timing reaches the sampling time)
Sampling Rate Setup
rate setting. Short press Enter Button to
enter the sampling rate time setting
page.
sampling rate is selected, - Short press the Enter
Button to confirm and return to the datalogger page.
setting, short press Enter Button to enter
the alarm setting.
The CO2 alarm value setting is first, a
short press of the Left Button increases
alarm limit, and a short press of the Right
Button decreases the alarm limit
short press button to
confirm the setting and enter the CO alarm
value setting and repeat steps.
the alarm value, the display value color changes from black to red,
and when the CO or CO2 exceeds the alarm value, the buzzer
sounds to alarm.
Brightness Setup
the display
brightness, short press Enter Button to enter
brightness adjustment. There are (4) levels
to select from.
Short press Left Button to decrease the
brightness; Short press Right Button to
increase the brightness.
CO 0 to 1000PPM 1PPM ±5% FS
CO2 0 to 9999PPM 1PPM ±3% ±75PPM
Temper0 to 50°C/32 to 0.1°C/0.1°±2°C/±4°F
Humidi
ty
**Note: The humidity test is tested under about 1m/s wind
speed, the response timeof the sensor to the accuracy of the
index is about 30 minutes.
** Note: Recommended CO measuring environment 0 to 40°C (32
to 104°F), 15 to 95%; CO2 measuring environment 0 to 50°C (32 to
122°F),0 to 85%.
General Specifications
0 to 100%RH
0.1%RH
±3.5% at (20% to 80%)
±5% at (0 to 20%)
±5% at (80% to 100%)
Triplett / Jewell Instruments extends the following warranty to the original
purchaser of these goods for use. Triplett warrants to the original purchaser
for use that the products sold by it will be free from defects in workmanship
and material for a period of (1) one year from the date of purchase. This
warranty does not apply to any of our products which have been repaired or
altered by unauthorized persons in any way or purchased from unauthorized
distributors so as, in our sole judgment, to injure their stability or reliability, or
which have been subject to misuse, abuse, misapplication, negligence,
accident or which have had the serial numbers altered, defaced, or removed.
Accessories, including batteries are not covered by this warranty