Triplett Test Equipment & Tools GSM350 User manual

Page 1
User Manual
GSM350
CO/CO2 Meter with Temperature and Humidity
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 2
Introduction
Congratulations on your purchase of the Triplett GSM350 Carbon Monoxide/Carbon Dioxide IAQ Meter The GSM350 simultaneously displays CO, CO2, Temperature and Humidity. The meter has a real-time clock, datalogs and has user settable alarms for CO/CO2.
Meter Description
1. CO/CO2 Sensor
2. Temperature and
3. LCD Display
4. Left Function
5. Right Function
6. ON/OFF Button
7. Enter/Record
8. Return Button
9. Air Bleed Outlet
10. Tripod Mount
11. USB (Charging
Humidity Sensor
Button
Button
Button
and Data) Port
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 3
Operation
Measurement Mode
Long press the ON/OFF Button to boot and shutdown.
of Time, Battery Power, CO, CO2, Temperature and Humidity in real time, CO will begin a sensor warm up period of 30 seconds and then will start to measure.
Click the Left Button to enter the setup page, you can set the
Language, Temperature unit switch, data sampling settings, automatic shutdown settings, alarm settings, brightness adjustment, time settings.
Short press of the Right Button will enter the CO, CO2
temperature and humidity and MAX/MIN/AVG mode.
Press the Enter/Rec Button to enter the history data query
interface.
MAX/MIN/AVG Mode
In this mode, the real-time data, maximum, minimum and average values for CO, CO2, Temperature and Humidity is displayed Short press Right Button pauses the reading.
Short press Left Button switches the
display page, so that CO, CO2, Temperature and Humidity can be switched in order
Press the Return Button to return to the main page.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 4
Setup Menu
User Interface allows for the custom setting of Language, Temperature Unit, Data Log sampling rates, Auto Power Off time, Alarm settings, Brightness adjustment, and time settings.
Short press Left/Right Button can move
cursor, Left Button , cursor moves up; Right Button corresponds
to cursor moves down.
press the Enter Button to enter the corresponding setting interface.
Language Setup
Use the cursor to move to the desire language setting.
Short press the Enter Button to enter
the language setting.
Short press Enter Button again to
confirm and return to the setting interface, so that the Chinese and English interface can be switched.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 5
Temperature Units (°C/°F) Setup
Unit, (°C or °F) press the Enter Button to enter the temperature unit setting.
Short press the Enter button to
confirm and return to the settings interface
Datalogger Setup
to move to the Datalogger settings, Press the Enter Button to enter the data sampling setting interface, The sampling rate, duration, and sleep mode can be set here.
duration setting is completed, the meter will automatically shut down (when the timing reaches the sampling time)
Sampling Rate Setup
rate setting. Short press Enter Button to enter the sampling rate time setting page.
sampling rate is selected, - Short press the Enter
Button to confirm and return to the datalogger page.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 6
Sleep Mode Setup
sleep mode setting, then short press Enter Button to enter the
sleep mode setting interface.
Short press the Enter Button to confirm and return to the datalogger page.
Auto Power OFF (APO) Setup
Use the cursor to Auto-off, short
press Enter Button to enter
automatic shutdown setting
User can select None, 2min,
10min, 1h. Press the Enter Button to confirm and return to the settings interface.
the meter will Auto Power Off at the selected
time.
Choosing None will run until low battery and shut down.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 7
Alarm Setup
setting, short press Enter Button to enter the alarm setting.
The CO2 alarm value setting is first, a short press of the Left Button increases alarm limit, and a short press of the Right Button decreases the alarm limit
short press button to confirm the setting and enter the CO alarm value setting and repeat steps.
the alarm value, the display value color changes from black to red, and when the CO or CO2 exceeds the alarm value, the buzzer sounds to alarm.
Brightness Setup
the display
brightness, short press Enter Button to enter
brightness adjustment. There are (4) levels to select from.
Short press Left Button to decrease the brightness; Short press Right Button to increase the brightness.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 8
Date/Time Setup
Date/Time setting , short press the Enter Button to enter the time initialization
setting.
year, short press Left Button plus, short press Right Button minus.
short press Enter Button confirmation into the month settings, and so on set the year.
short press Left, or Right
Button can achieve switching.
enter the time division setting, short press Left Button
plus, short press Right Button minus.
Confirm and exit by Enter Button after setting up.
History (Page 1)
long press the Enter Button to enter the sampling history data query page. Move the cursor through the Left/Right Button, select the
corresponding date and time data.
Short press the Enter Button to enter the CO2, CO, Temperature
and Humidity selection interface.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 9
History (Page 2)
g the selection interface, there are CO2, CO, Temperature and Humidity options.
Enter Button to enter the histogram display interface.
Histogram Query (Page 3)
You can query the real-time data corresponding to the history time and the MAX/MIN/AVG value. And visualize it in the form of histogram.
A short press Left Button can make time move forward, a short press of the Right Button can make time move back, the
change of time can be seen in the operation process.
Exporting Logged Data to .CSV File
OFF state, you can use USB lcable
to connect to the computer and to transfer the logged data.
also delete files from this mode.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 10
Maintenance
F
unction
R
ange R
esolution
Accuracy
products must be repaired by professionals.
s are subject to change.
Specifications
CO 0 to 1000PPM 1PPM ±5% FS CO2 0 to 9999PPM 1PPM ±3% ±75PPM Temper 0 to 50°C/32 to 0.1°C/0.1° ±2°C/±4°F
Humidi ty
**Note: The humidity test is tested under about 1m/s wind speed, the response timeof the sensor to the accuracy of the index is about 30 minutes. ** Note: Recommended CO measuring environment 0 to 40°C (32 to 104°F), 15 to 95%; CO2 measuring environment 0 to 50°C (32 to 122°F),0 to 85%.
General Specifications
0 to 100%RH
0.1%RH
±3.5% at (20% to 80%) ±5% at (0 to 20%) ±5% at (80% to 100%)
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 11
Warranty
Triplett / Jewell Instruments extends the following warranty to the original purchaser of these goods for use. Triplett warrants to the original purchaser for use that the products sold by it will be free from defects in workmanship and material for a period of (1) one year from the date of purchase. This warranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as, in our sole judgment, to injure their stability or reliability, or which have been subject to misuse, abuse, misapplication, negligence, accident or which have had the serial numbers altered, defaced, or removed. Accessories, including batteries are not covered by this warranty