Triplett XR-5 User Manual

Page 1
WireMaster XR-5
5 Cable Tester
www.triplett.com
CAUTION: Read, understand and follow all Safety
Rules and Operating Instructions in th is i nstruction
manual before using this product.
84-851
Page 2
CONTENTS
1. Introduction
2. Safety Rules and Warnings
3. Product Features
4. Specifications
5. Front Panel
6. Operation
7. Cable Repairs
8. Maintenance
9. Accessories
10. Warranty
1: INTRODUCTION
The Triplett WireMaster XR-5 tests 5 common LAN and Computer cables. It tests installed cables or patch cords with RJ-45, RJ-11, 1394, USB, and BNC connectors. It is intended
to test cables with straight through connections ...... not cables
with reversed or transposed connections like some LAN crossover cables or reverse wired telephone cables.
-1-
Page 3
2: SAFETY RULES & WARNINGS
This tester is not intended for use on powered circuits. Attaching this tester to a powered circuit can result in
2.1 Read all instructions in this manual before using this
2.2 Do not use this tester with its case open , or with parts
2.3 When using this tester in schools and workshops,
2.4 Follow the recommendations of any Trade Orga nizations
2.5 Do not open this tester for maintenance without first
2.6 Repairs and maintenance must only be carried out by
2.7 Do not touch th e ends of the cables when making tests.
2.8 Do not apply voltage or current to any of the tester's
damage to the tester or injury to the user.
tester. Failure to do so may result in damage to the tester or injury to the user.
removed. Doing so may damage the tester and/or injure the user.
responsible teachers or skilled personnel must control the usage of this tester. Failure to observe this precaution may result in damage to the tester or injury to the user.
or Regulatory Agencies whose scope encompasses the use of this tester. Failure to do so m ay result in damage to the tester or injury to the user.
disconnecting it from all external circuitry. Failure to observe this precaution may result in damage to the tester or injury to the user.
qualified service personnel or qualified electricians / technicians who know the dangers of, and the safety rules applicable to this type of equi pment. Failure to observe this precaution may result in damage to the tester or injury to the user.
An unexpected dangerous potential may be present. Failure to observe this precaution may result in damage to the tester or injury to the user.
connectors. Doing so may damage the tester and/or injure the user.
WARNING!!!
-2-
Page 4
2.9 This tester is not for use by children. Failure to observe this precaution may result in damage to the tester or injury to the user.
2.10 Do not use this tester to make measurements in adverse environments such as rain, snow, fog, or locations with steam, explosive gases or dusts.
2.11 Do not use tester in condensing atmospheres. That is, do not use tester in conditions where ambient temperature and humidity could cause condensation of water inside of the tester.
2.12 Do not use this tester if it is wet, either from exposure to the weather, or after cleaning the case of the tester.
2.13 Do not attempt immediate use of the tester when bringing it from a cold environment to a warm environment. Condensation of water, inside and outside of the tester, may produce dangerous measuring conditions . Allow the tester to warm to room temperature before using.
2.14 Do not modify this tester. Changing the design may make the tester unsafe and may result in injury to the user.
2.15 Do not use the tester if it has undergone long-term storage under unfavorable conditions.
2.16 Do not use the tester if it may have been damaged in transport.
2.17 Avoid usage near strong magnetic fields (magnets, loudspeakers, transformers, motors, coils, relays, contactors, electromagnets, etc.). The tester may display readings that are in error.
2.18 Avoid usage near strong elect rostati c fields (high vo ltage power lines, televisions, computer monitors, etc.). The tester may display readings that are in error.
2.19 Avoid usage near strong RF fields (radio or television transmitters, walkie talkies, cellular phones, etc.). The tester may display readings that are in error.
2.20 Remove the battery when the tester may be left un used for longer than 1 month. Chemical leakage from the battery could damage the tester.
2.21 Do not use the tester if there is evidence of chemical leakage from the battery.
-3-
Page 5
3: PRODUCT FEATURES
3.1 Tests 5 types of cables
3.2 Simple one button test
3.3 Ergonomic portable handheld design
3.4 Tests installed wiring or patch cables
3.5 Remote unit stores on Main unit
3.6 600 ft test distance (RJ-45 / RJ-11 / BNC)
3.7 Convenient battery access
3.8 Built in battery test
3.9 LEDs indicate connections and faults
3.10 Beeper provides audible annunciation of test results
3.11 Tests shielded (STP) or unshielded (UTP) LAN cables
3.12 Tests shields in 1394 and USB cables
4.1 Cables Tested: UTP and STP LAN cables
4.2 Faults Indicated: No Connection, Shorts,
4.3 Low Battery
4.4 Case
4.5 Weight:
4.6 Battery: 1 standard 9 volt alkaline battery,
4: SPECIFICATIONS
Annunciator: ..
Dimensions: (w/ Remote)
(without battery)
terminated in RJ-45 male connectors (EIA / TIA 568)
RJ-11 cables with male connectors, 2 to 6 conductors installed
1394 Cables with Type 1 plugs on both ends
USB cables with Type A "flat" plug on one end and Type B "square" plug on other end
BNC cables with male connectors
Opens, Crosses LED lights to indicate low bat tery
7.25 x 4.0 x 1.0 inches (L x W x H)
18.4 x 10.2 x 2.5 cm, (L x W x H)
202 grams, 0.445 lbs.
Triplett Part Number 37-48
-4-
Page 6
5: FRONT PANEL &
XR-5 DIAGRAM
1 Test Button 2 Main Display 3 RJ-45 Jack 4 RJ-11 Jack 5 1394 Jack 6 USB Jack 7 BNC Jack
-5-
Page 7
6.1 General Information:
The WireMaster XR-5 performs its tests when the single button on its front panel is pres sed an d releas ed. 6 St atus LEDs indicate the condition of the cable being tested, as well as informing the user that Power is turned on, and that the battery is good (or bad). 8 additional "connection" LEDs light to indicate that specific wires in a cable are connected. A chart beneath the 8 LEDs shows the LEDs that should light for a good cable.
Note: Only one cable can be tested at a time. I.e. A BNC cable and an RJ-45 cable cannot be tested simultaneously.
6.2 The MAIN and REMOTE unit:
The WireMaster XR-5 consists of a Main unit and a Remote unit. The Remote unit stores conveniently on the bottom of the Main unit. It can be removed or replaced by sliding it from left to right or right to left respectively.
Use care when removing or replacing th e Remote some of the plastic edges are a little sharp.
The Remote is often attached to the Main unit when storing, when transporting, or when Patch cables are being tested. The Remote is removed from the Main unit when an installed (in wall, ceiling, etc.) cable is being tested.
6.3 Testing Patch cables:
"Patch" cables have both ends accessible at the same location. Usually, but not always, these cables are less than 25ft in length, and are not installed in a wall or ceiling. Since both ends are accessible, one end can be plugged into the XR5's Main unit , and one end into the Remote unit. It is not necessary to remove the Remote unit from its "docked" position on the Main unit.
6.4 Testing Installed cables:
To test cables installed in ceilings or walls, or in applications that prevent the ends from being in the same location, the Remote can be detached from the Main unit. Once detached, the Remote can be attached to one end a cable, and the Main unit attached to the other end of the cable. These ends are often in different rooms and on different floors of a building.
6: OPERATION
-6-
Page 8
6.5 Performing the Test:
Once the Remote and Main unit are attached to the ends of the subject cable, as described in 6.3 and 6.4, testing may begin. Simply press and release the Test Button on the Main unit, observe the LED indicators, and note the beeping sound that comes from the Main unit.
6.6 Interpreting the Results:
6.6.1 Power LED:
The Power LED should light whenever the Test Button is pressed and released. It will stay on for a minimum of 5 seconds, or for however long the Test Button is pressed. If the Power LED does not light, replace the battery.
6.6.2 Low Battery LED:
The Low Battery LED should not light. If it does, replace the battery.
6.6.3 No Connection LED / Single Beep
If the Remote is not connected to the Main unit with a cable, or the cable has no intact conductors, the No Connection LED with light and th e Beeper will sound once.
6.6.4 Connected LED / Lo-Hi Beep / Numbered LEDs
If the Connected LED lights and the Beeper emits a Lo­Hi beep, examine the Numbered LEDs (i.e. LEDs numbered 1 to 8, and the S/G LE D).
The Numbered LEDs corresponding to the type of cable being tested must light. Examine the table below the Numbered LEDs, noting what LEDs should light. If all of these LEDs do not light, the cable has an OPEN fault.
If all of the appropriate Numbered LEDs light, the cable is OK.
Notes: When testing an RJ-45 UTP cable, the S/G LED must not light. When testing an RJ-45 STP cable, the S/G LED must light.
The XR-5 is intended to test compl ete cables. It may not find faults in cables that are intentionally incomplete. For example, the standard EIA / TIA 568 RJ-45 terminated Ethernet cable is expected to contain 8 conductors . If o nly 4 conductors are us ed between the RJ-45 connectors, the XR-5 may not properly identify the faults.
RJ-11 cables may have 2 connections, 4 connections, or as many as 6 connections. For 2 connection cables, LEDs 3 and 4 must light. For 4 connection cables, LEDs 2, 3, 4, and 5 must light. For 6 connection cables, LEDs 1, 2, 3, 4, 5, and 6 must light.
-7-
Page 9
The Numbered LEDs DO NOT indicate that a GOOD connection exists, only that a connection exists. If the Sh ort or Cross LEDs are lit, there is a fau lt in the cable.
6.6.5 Connected LED/3 Beeps/Short LED/Numbered LEDs
If the Connected LED lights, the Beeper emits 3 beeps, and the Short LED lights, the cable has a fault. The Numbered LEDs indicate the location of a short.
Note:
In the Short mode, the Numbered LEDs only indicate the location of the shorts. The other connections in the cable are not indicated. If more than 3 Nu mbered LEDs light, th ere may be multiple shorts in the cable.
6.6.6 Connected LED/2 Beeps/Cross LED/Numbered LEDs
If the Connected LED lights, the Beeper emits 2 beeps, and the Cross LED lights, the cable has a fault.
Notes:
In the Cross mode, the Numbered LEDs indicat e connections but do not indicate the location of the cross.
RJ-11 cables used for telephone connections are of ten crossed. Even new cables are often crossed. This seldom affects the performance of standard analog telephone lines (POTS). Digital telephone lines and old touch tone phones may be polarity sensitive, so a crossed cable may prevent them from working properly.
7.1 General Information: The following section provides information to the user about common cable types, common failures, and repairs. It is not meant to b e an exhaustive study of the topic, just some basic information that the uninitiated may find helpful.
7.2 Cable damage: When a cable tests bad, either the wire or the connectors or both may be at fault. If the cable has been installed and working, then its likely that the wire or connectors have been abused in some way. The wire portion of the cable can be damaged by being crushed (under the leg of a desk), stretched (pulled sharply around a corner), punctured (by a nail or staple), overvoltaged (hit by lightening), burned, etc. Similar abuses will damage the connectors on the ends of the
7: Cable Repair
-8-
Page 10
cable. The connectors can also be damaged by excessive insertion and removal or flexing of the cable close to connector body.
While the WireMaster XR-5 can identify a bad cable, it cannot determine if the wire or the connectors are at fault. The user must examine the different parts of the cable to determine the cause of failure and take the appropriate steps to correct the problem.
7.3 Which end is bad? The XR-5, like many cable testers, cannot find the location of the fault, o r even determine which end or connector is bad. It simply "knows" that a fault exists. The user must locate the fault and take the appropriate action.
7.4 Cables with Molded on ends: Many cables have molded on end s that cann ot be opened up for repair. The entire cable must be replaced, or the molded on end removed and replaced with a user serviceable connector. These types of cables usually fail from Opens or Shorts. They seldom fail from a Crossed connection.
7.5 Cables with Crimped on RJ connectors: Crimped on RJ connectors cannot be reused or repaired. New connectors must be installed on the cable. If the cable being tested has just been "made up" or put in service, and it tests as Open or Crossed, the RJ co nnectors have probably been installed incorrectly. Shorts very se ldom occur as the result of a badly crimped RJ connector, so the user should suspect a problem with the wire (possibly a staple or nail through the wire, or a crushed or pinched wire) if the XR-5 indicates a Short. A visual examination
of the RJ connectors may reveal the fault...... but keep in
mind that whatever the cause of a connector problem (i.e., miswiring, improper stripping of the wire, bad crimp, etc.), the only solution is to replace the connector. Consequently, it is not necessary for the user to know the exact cause of the problem, simply to make sure that he installs the new connector c orrectly!
7.6 Conflicting Results: Sometimes, the tests results of the XR-5 seem to conflict with the performance of the
cable........ i.e., the cable tests bad but works OK, or vice
versa. The following items list some of the reasons why.
7.6.1 The WireMaster XR-5 says my cable is bad, but my LAN works OK: Installed LAN cables with RJ-45
connectors that have been in service and working OK
may test as Open, Shorted, or Crossed. Here's why.........
-9-
Page 11
The EIA / TIA 568 standard for LAN cables only uses 4 of the wires in the eight wire cable. The other 4 wires in the cable may have faults, but these wi ll not affect the operation of the LAN. The XR-5 tests all of the wires in the LAN cable, and identifies the faults, even though these wires may not be being used in the LAN system.
Not all LAN cables are wired "straight through". Crossover cables used on LANs are purposely "miswired", with their Receive and Transmit wires "crossed over". The XR-5 will test this as a bad cable, but it may work just fine as a Crossover cable.
7.6.2 The WireMaster XR-5 says my cable is good, but it doesn't work on my LAN: Many cable testers like the
XR-5 only perform continuity style tests (Open, Short, Crossed, etc.). Ethernet LAN cables are constructed in a special way. The 8 wires inside are grouped into 4 pairs of 2 wires each. Not only must the 8 wires connect from end to end of the cable, the pairs in the cable must connect to specific pins of the RJ-45 connectors. An installer can crimp the RJ-45 plugs onto the ends of a cable, ignoring the pairing (as described in EIA / TIA
568), and the cable will test OK. But when the cable is tried on the LAN, it doesn't work. This is because the lack of proper pairing causes excessive crosstalk in the cable, preventing the LAN from working. This type of cable fault is sometimes called a "split pair" or "double split pair". To detect this type of fault, a more sophisticated tester capable of performing a NEXT test (Near End Cross Talk) must be used. Both the Triplett PairMaster and LAN TDR can perform N EX T tests.
Note:
Crosstalk increases with the length of the cable. A LAN s ystem will tolerate a certain amount of crosstalk. A sh ort cab le (10 ft or less) that is improperly paired may work just fine. However, longer cables, paired in exactly the same way, may not wo rk. This explains why an installer can ma ke short jumper cables that work (although they are improperl y paired), but when he installs RJ-45's in exactly the same way on a longer cable, the cable does not work.
7.6.3 The WireMaster XR-5 says says my phone cable is bad, but my phone works OK.
Most single line telephones only use 2 wires in a modular cable. The modular cable, which terminates in RJ-11 connectors, could have as many as 6 wires in it. The unused wires may have faults, which the XR-5 will identify, but these faults may have no effect on the working 2 wire telephone circuit.
-10-
Page 12
Many telephone cables with RJ-11 plugs / jacks are wired in reverse. The XR-5 will show that a cable like this is Crossed. A cable like this reverses the polarity of the telephone line. Most regular telephones made in t he last 20 years are not polarity sensitive. So, even thoug h the cable is wired in reverse (crossed), it may work OK.
Early touch tone telephones and answering machines were polarity sensitive. If connected in reverse polari ty, the touch tone phone may not dial out (no touch tone), and the answering machine may not answer when the line rings.
7.6.4 The WireMaster XR-5 says my RJ-11 phone cable is good, but my phone doesn't work.
First, make sure the telephone line is hooked up and "live" by using a tester like the Triplett Line Bug or Line Bug 2. This simple tester will verify the pres ence o f loop current, and will test the polarity of the line.
The "good" cable may result in a reversed line. The Line Bug will show reversed if this is the case. The line is not
actually being reversed in the good cable......its been
reversed somewhere else along the wire. Either the reversed cable can be located and corrected, or, an often used simpler approach is to replace th e good cabl e with a reversed cable, making the polarity come out correctly. It is also worth knowing that some female/female couplers reverse the polarity of the phone line.
Analog telephones will usually work, regardless of line polarity. Digital phones are often polarity sensit ive, and may not work with reversed line polarity.
-11-
Page 13
8: MAINTENANCE
Your Triplett WireMaster XR-5 is a precision test instrument and, when used as described in this manual, should not require maintenance. There are no internal adjustments. Calibration is not required.
To clean the outside of the tester, use a cloth dampened with a mild detergent solution. Do not use any abrasive cleansers, or chemical solvents that may damage the case of the tester.
TRIPLETT PRODUCT RETURN INSTRUCTIONS
In the unlikely event that you must return your Triplett equipment for repair, the fol lowing steps must be taken.
1) Call 1-800-TRIPLETT to obtain a Return Material
Authorization (RMA) number from Customer Service.
2) Enclose a copy of the original sales receipt showing date
of purchase.
3) Clearly print the RMA number on the outside of the
shipping container.
4) Return to: Triplett Corporation
One Triplett Drive Bluffton, OH 45817
Be sure to include a full description of the problem, and a telephone number, street address, or email address, where you can be contacted, and a return address where the meter can be shipped to upon repair.
ATTN: Repair Dept.
-12-
Page 14
9.1 The Triplett WireMaster XR-5 package contains the
following items:
WireMaster XR-5 Main Unit
Female BNC Terminator (PN: 26-940)
Male / Male BNC jumper cable (5"), (PN: 26-937)
Male / Male RJ-11 jumper cable, 4 wire (PN: 26-938)
Male / Male RJ-45 STP jumper cable, EIA / TIA 568, (PN: 26-939)
9 volt battery (PN: 37-48)
Instruction Manual (PN: 84-851)
Carrying Case (PN: 10-4250)
9: ACCESSORIES
WireMaster XR-5 Remote (PN: 3260-R)
-13-
Page 15
10: WARRANTY
Triplett One Year Limited Warranty
The Triplett Corporation warrants instruments and test equipment manufactured by it to be free from defective material or workmanship and agrees to repair or replace such products which, under normal use and service, disclose the defect to be the fault of our manufacturing, with no charge within three years (one year on calibration) of the date of original purchase for parts and labor. If we are unable to repair or replace the product, we will make a refund of the purchase price. Consult the Instruction Manual for instructions regarding the proper use and servicing of instruments and test equipment. Our obligation under this warranty is limited to repairing, replacing, or making refund on any instrument or test equipment which proves to be defective within three years from the date of original purchase. This warranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way so as, in our sole judgment, to injure their stability or reliability, or which have been subject to misuse, abuse, misapplication, negligence, accident or which have had the serial numbers altered, defaced, or removed. Accessories, including batteries and fuses, not of our manufacture used with this product are not covered by this warranty. To register a claim under the provisions of this warranty, contact Triplett Corporation's Customer Service Department for a Return Authorization Number (RMA) and return instructions. No returned product will be accepted without an RMA number. Upon our inspection of the product, we will advise you as to the disposition of your claim.
ALL WARRANTIES IMPLIED BY LAW ARE HEREBY LIMITED TO A PERIOD OF THREE YEARS (ONE YEAR ON CALIBRATION) FROM DATE OF PURCHASE, AND THE PROVISIONS OF THE WARRANTY ARE EXPRESSLY IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED.
The purchaser agrees to assume all liability for any damages and bodily injury which may result from the use or misuse of the product by the purchaser, his employees, or others, and the remedies provided for in this warranty are expressly in lieu of any other liability Triplett Corporation may have, including incidental or consequential damages. Some states (USA ONLY) do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. No representative of Triplett Corporation or any other person is authorized to extend the liability of Triplett Corporation in connection with the sale of its products beyond the terms hereof. Triplett Corporation reserves the right to discontinue models at any time, or change specifications, price or design, without notice and without incurring any obligation. This warranty gives you specific legal rights, and you may have other rights which vary from state to state.
-14-
Page 16
Triplett Corporation
One Triplett Drive, Bluffton, OH 45817
PH: 419-358-5015 FAX: 419-358-7956
1-800-874-7538 www.triplett.com