Triplett POE2000 User Manual

Page 1
POE2000 Pro
PoE Tester
USER MANUAL
Introduction
Thank you for purchasing the Triplett POE200 POE TESTER PRO. Please read the manual carefully before using the product. This tester helps to speed up the installation and troubleshooting of PoE systems devices. The Main Functions of this tester are:
Detecting PSE-type/class, power source, polarity and voltage  Determining-standard PoE or NON-standard passive PoE  Inline Power Level Monitoring
The standard compliance this tester works for are:
IEEE 802.3 af,(PoE)  IEEE 802.3 at (PoE+)  IEEE 802.3 bt (PoE ++)
Page 2
1
RJ45 PSE Test Jack
2
(2) LED indicators for Power Type Reverse (REV) Polarity
3
(4) LED indicators for IEEE 802.3 af or IEE802.3 at/bt Standard
4
LCD Display for Voltage , Current and Power
5
STEP Button for selecting specific data to be displayed (Default is Voltage)
6
RJ45 PD Test Jack
Description
3 www.triplett.com UM-POE2000
Page 3
Operation
Either IEEE 802.3 af or 802.3 at compliant standard and either Endspan, Midspan or Ultra-4 pair Power Source
IEEE 802.3 af - Power Source End (A)
Note: This tester does not need a battery to operate as it uses system power when connected to a device.
Connect to RJ45 PSE Test Jack for PSE type tests (PoE switches, PoE midspan switches, PoE (Active / Passive) injectors.
Connect to RJ45 PD Test Jack for PD tests (IP camera, IP phone and Wireless AP and Other Network Appliances.
Connect Inline for Inline Power Level Monitoring (Voltage (V), Current (mA/A), Power (W)
Pressing the STEP Button allows the selection of specific test data for reading.
Display Ledger
4 www.triplett.com UM-POE2000
Page 4
IEEE 802.3 at - Power Source End (A)
IEEE 802.3 af - Power Source Mid (B)
IEEE 802.3 at - Power Source Mid (B)
REVERESED Polarity Power Source either Endspan, Midspan or both
5 www.triplett.com UM-POE2000
Page 5
Numeric LCD for Inline Power Testing (U) Voltage, (A) Current, (P) Power STEP Button cycles: Voltage CurrentPower
Test Modes
There are (3) Modes of operation for this tester selectable by the switch at the rear of the tester. The function modes are as follows:
T mode: for detecting PSE status N mode: for determining NON-standard PoE + inline testing I mode: for testing and monitoring real time power status
Operation Notes
When performing Inline Testing in T-Mode connect to the PSE side of
the tester first .until voltage is displayed, then connect PD side.
The length of the cable and the quality of the cable or the pin location
in the RJ45 connector can affect the real power available. To ensure the power at the other end of the wall outlet is what is required for PD test the wattage level at the wall outlet/jack where the PD plugs in.
The STEP button allows you to select specific test data for easier
reading .Pressing this button once will change auto-rotate to step mode, and voltage display will be the default measurement. Press the button again to select current or power display.
To revert back to auto-rotate, disconnect the PSE side cable (If in
Inline Testing disconnect PD side cable first, then disconnect the PSE
6 www.triplett.com UM-POE2000
Page 6
side of the cable), Reconnecting the PSE to the tester will start auto­rotate display.
To perform a reset, first unplug the cable from PD side, next unplug
the PSE side cable. Reconnect the PSE side until voltage values are displayed then connect to the PD to be tested.
The tester cannot measure and test PD alone, it has to be connected
to a PSE first, Once this is done then connect to the PD, after negotiation process, the tester will start power Level testing.
**CAUTION**: Before connecting PD to the tester make sure that the PD to be connected is either a standard PoE powered device or a non-PoE powered device to avoid damaging a non-PoE device is damaged by a non-standard passive PoE power.**
7 www.triplett.com UM-POE2000
Page 7
Specifications