Congratulations on your purchase of the Triplett EPC175 Particle Counter/Air
Quality Meter. This device is a particle counter/ air quality detector that
includes several measurement types. It can detect PM2.5, PM10, HCHO,
TVOC, temperature and humidity.
This device uses a laser weight scattering test method and includes a
professional structure design and fan. It can precisely detect and monitor
and display PM2.5 and PM10, and indoor air quality. HCHO can detect
formaldehyde and TVOC can detect indoor harmful gas, alerting the user of
any environmental pollution. In order to detect PM2.5, PM10, HCHO and
TVOC at the same time, it adopts reliable power supply circuity to ensure all
measurements are precise and stable and operate for extended periods of
time.
Features
● 3.0’’ TFT LCD Display,240*400 Pixels
Description
● Measures mass concentration of PM2.5/PM10
● Measures HCHO & TVOC
● Measures Temperature & Humidity
● 5000 groups of sampling data
● Auto Power Off (APO)
METER DESCRIPTION
Page 3
Set/Up Button: Long press to enter/exit the settings page; Short
press to switch measurement displaying in measure page, or to
turn on in settings/memory page.
ON/OFF/ENTER Button: Long press to startup/shutdown; Short
press to enter/exit in settings/memory page.
Memory/Down Button: Long press to enter/exit the memory
page; Short press to switch measurement displaying in measure
page, or to down on in settings/memory page.
Operation
Power ON/OFF
In shutdown mode, long press ON/OFF/ENTER key until the
screen light, device will power ON.
In startup mode, long press ON/OFF/ENTER key until the screen
off, device will power OFF..
Display Description (Measurement Data Areas)
Page 4
After powered ON and start up the meter will display and measure
data continuously. The measurements consist of PM2.5, PM10,
TVOC, HCHO, temperature and humidity readings. The meter will
refresh the screen and toggle between a display of PM10, TVOC,
and HCHO every 15 seconds. You can short press
ON/OFF/ENTER key to switch display manually.
PM2.5, PM10 and TVOC need 40 seconds warm-up time, during
this time the last measurement recorded is displayed. The analog
bar graph shows, air quality and has six alarm levels. If the air is
polluted, the meter will alarm based on the reading value of
measured data the display will change color. All alarms are based
on real time data.
Page 5
Auto Power OFF (APO), Sleep and Wake-Up Modes
Auto Power OFF/Sleep Mode
The meter can be set to auto power off or auto sleep. If there are long
intervals without change in operation, the meter can auto power off or auto
sleep to save consumption.
Wake-Up (Button Press)
This meter can awake form shutdown status by long press of
ON/OFF/ENTER key.
Wake-up (Noise)
Noise also can be used to awaken the metere, for example striking table can
awaken the meter from sleep status to measure status. This meter can
awake by noise within 30 minutes after shutdown.
Memory
In the measurement page a LONG PRESS of the MEM/Down button enters
and exits the memory page.
The MEMORY page will dynamically display the latest curve of measurement
data. To view the static measurement data, SHORT PRESS of the
ON/OFF/ENTER button.
Page 6
In static MEMORY page, the meter displays the static curve of measurement
data, a SHORT PRESS of the Up/Down button will view the detail of
historical data one by one.
The meter can record memory data as many as 5000 points, which contents
include PM2.5, PM10 and record times. In MEMORY page, one curve
includes (8) data point/measurements. Indications are – a bright spot for the
data, dark spot for connection, and a dot for the current data. A SHORT
PRESS of the Up/Down button will display before and after historical data.
Settings
Time Settings
Time can be set up hourly (12 hours or 24 hours), AM/PM, date and time.
Short press Up/Down key to change time settings, and short press
ON/OFF/ENTER key to confirm, after confirm all setting items then exit and
back to the main menu of settings page.
Auto Power Off/Auto Sleep Settings
APO can set up auto power off/auto sleep time as 10~120 minute or no auto
power off/auto sleep.
Unit Settings
Temperature units can be set up for unit of temperature as Celsius(℃) or
Fahrenheit(℉), the default is Celsius.
Page 7
Alarm Settings
Color
Green
Yellow
Orang
e
Red
Purple
Deep
Purple
Concentration
0~35μg/m3
35^75μ
g/m3
75~150
μg/m3
150~200
μg/m3
200~25
0μg/m3
>250μ
g/m3
Air Quality
Good
Normal
Mild
Pollut
ed
Middle
Polluted
Heavy
Pollut
ed
Serious
Polluted
Alarms can be set for the start point of PM2.5 alarm as 10ug/m3, 35ug/m3,
75ug/m3, 150ug/m3, 200ug/m3 or no alarm, which default is 35ug/m3. If
PM2.5 alarm is enable, the meter will beep when concentration of PM2.5 is
so high as to beyond the set start point of PM2.5 alarm.
Brightness Settings
Screen Brightness can be set, there are (5) levels of screen brightness.
Noise Sensor Settings
Enable/disable noise sensor. If enabled, device can be awake from
shutdown/sleep status by noise sensor.
Language Settings
Language can be set to English or Chinese,default is English.
Air Quality Standard
PM2.5 Concentration and Corresponding Index Color Table
Page 8
Color
Green
Yellow
Orange
Red
Purple
Deep
Purple
Concentration
0~75μ
g/m3
75~150μ
g/m3
150~300μ
g/m3
300~400μ
g/m3
400~500
μg/m3
>500μ
g/m3
Air Quality
Good
Normal
Mild
Polluted
Middle
Polluted
Heavy
Polluted
Serious
Polluted
Color
Green
Orange
Red
CO2
Concentration
0~800ppm
800~1500ppm
1500~9999ppm
HCHO
Concentration
0~0.05mg/m3
0.05~0.1mg/m3
0.1~5.00mg/m3
TVOC
Concentration
0~0.6mg/m3
0.6~1.8mg/m3
1.8~9.99mg/m3
Air Quality
Good
Normal
Bad
PM10 Concentration and Corresponding Index Color Table
PM10、CO2、HCHO、TVOC Concentration and Corresponding Index
Color Table
Page 9
Specifications
Particle Measure
Particle Channels
PM2.5/PM10
Mass Concentration Range
0 ~ 2000 μg/m3
Resolution
1μg/m3
HCHO
Range
0.00~5.00 mg/m3
Accuracy
±5% F.S
Resolution
0.01 mg/m3
TVOC Measure
Range
0.00~9.99 mg/m3
Accuracy
±5% F.S
Resolution
0.01 mg/m3
Temperature & Humidity Measure
Temperature Range
-20 ~ 70℃ (-4 ~ 158℉)
Temperature Accuracy
±2℃
Temperature Resolution
0.1℃
Humidity Range
0 ~ 100%RH
Humidity Accuracy
±3.5%RH(20 ~ 80%RH)
±5%RH(0~20%RH or
80~100%RH)
Humidity Resolution
0.1%RH
Intelligent Sensor
Noise Detect Sensor
A slight noise can awaken device
Power
Battery
2400mAh Recharge Li-ion Battery
Work Time
Able to continue work almost 5 hours
Charging
USB 5V/1A
Charging Time
Almost 2 hours when shutdown
Auto Sleep
Able to set auto sleep time
Page 10
Others
Display
3.0’’TFT LCD Display, 240 * 400
Pixels
Data Storage
5000 groups of sampling data
Work Temperature
0 ~ 50 ℃
Storage Temperature
-10 ~ 60 ℃
Size
85 * 75 * 155
Weight
360g
Warranty
Triplett / Jewell Instruments extends the following warranty to the original purchaser of
these goods for use. Triplett warrants to the original purchaser for use that the products
sold by it will be free from defects in workmanship and material for a period of (1) one
year from the date of purchase. This warranty does not apply to any of our products
which have been repaired or altered by unauthorized persons in any way or purchased
from unauthorized distributors so as, in our sole judgment, to injure their stability or
reliability, or which have been subject to misuse, abuse, misapplication, negligence,
accident or which have had the serial numbers altered, defaced, or removed.
Accessories, including batteries are not covered by this warranty