Model Number 9325 9305 9200-A
AC Current
DC Current
AC Voltage
DC Voltage
Resistance
(Ohms)
Frequency
Capacitance
Digital Clamp-On Meter FunctionsPhysical Safety
Temperature (K-Type)
Continuity
Diode Check
Duty Cycle
Total Ranges / Functions
0.1A to 1000A True RMS
1(600A, 0.1A res) ± (2.8% rdg + 8 dgts)
1(1000A, 1A res) ± (3.0% rdg + 8 dgts)
0.1A to 1000A
1(600A, 0.1A res) ± (2.8% rdg + 5 dgts)
1(1000A, 1A res) ± (3.0% rdg + 5 dgts)
0.001V to 600V True RMS
2(6/60V, 0.001/0.01V res) ± (1.8% rdg
+ 8 dgts)
1(600V CAT III, 0.1V res) ± (1.8% rdg +
8 dgts)
0.001V to 600V
1(600mV, 0.1mV res) ± (0.8% rdg + 2 dgts)
2(6/60V, 0.001/0.01V res) ± (1.5% rdg
+ 2 dgts)
1(600V CAT III, 0.1V res) ± (1.5% rdg +
2 dgts)
0.1Ω to 60M
1(600Ω, 0.1Ω res) ± (1.0% rdg + 4 dgts)
3(6/60/600K, 0.001/0.01/0.1K res)
± (1.5% rdg + 2 dgts)
1(6M, 0.001M res) ± (2.5% rdg + 3 dgts)
1(60M, 0.01M res) ± (3.5% rdg + 5 dgts)
10Hz to 10KHz
4(10/100Hz__1/10K,
0.01/0.1Hz__0.001/0.01K res)
±(1.5% rdg + 2 dgts)
40nF to 4000µF
1(40nF, 0.01nF res) Unspecified
3(400nF__4/40µF, 0.1nF__0.001/0.01uF res)
± (3.0% rdg + 5 dgts)
1(400µF, 0.1µF res)
± (4.0% rdg + 10 dgts)
1(4000µF, 1µF res)
± (5.0% rdg + 10 dgts)
-4° to 1400°F
1(-4° to 1400°F, 1°F res) ± (3.0% + 9 dgts)
1(-20° to 760°C, 1°C res) ± (3.0% +
5 dgts)
28 27 2
0.01A to 400A
1(40A, 0.01A res) ± (2.5% + 8 dgts)
1(400A, 0.1A res) ± (2.8% + 8 dgts)
- -
0.001V to 600V
3(4/40/400V, 0.001/0.01/0.1V res) ± (1.8%
+ 8 dgts)
1(600V CAT III, 1V res) ± (2.5% + 8 dgts)
0.001V to 600V
1(400mV, 0.1mV res) ± (0.8% + 2 dgts)
3(4/40/400V, 0.001/0.01/0.1V res) ± (1.5%
+ 2 dgts)
1(600V CAT III, 1V res) ± (2.0% + 2 dgts)
0.1Ω to 40M
1(400 , 0.1 res) ± (1.0% + 4 dgts)
3(4/40/400K, 0.001/0.01/0.1K res) ± (1.5%
+ 2 dgts)
1(4M, 0.001M res) ± (2.5% + 3 dgts)
1(40M, 0.01M res) ± (3.5% + 5 dgts)
10Hz 10KHz
4(10/100Hz__1/10K,
0.01/0.1Hz__0.001/0.01K res)
±(1.5% rdg + 2 dgts)
40nF to 100µF
1(40nF, 0.01nF res) ± (4.0% rdg + 20 dgts)
3( 400nF__4/40uF, 0.1nF__0.001/0.01uF
res)
± (3.0% rdg + 5 dgts)
1(100µF, 0.1uF res) ± (4.0% rdg + 10 dgts)
-4° to 1400°F
1(-4° to 1400°F, 1°F res) ± (3.0% + 9 dgts)
1(-20° to 760°C, 1°C res) ± (3.0% + 5 dgts)
- -
0.01A to 300A
2(40/300A, 0.01/0.1A res) ± (1.8% rdg
+ 5 dgts)
-
-
-
-
-
-
-
-
Overload Protection
All Ranges
Agency Approval
Battery
Max Cable Diameter
Dimensions
Weight
CAT III 600V AC/DC CAT III 600V AC 400A AC for 60 Seconds Max
CE
IEC 1010-1
1 - 9 Volt 2 - AAA 1 - 3 Volt
500MCM 450MCM 300MCM
9.5” x 2.75” x 1.5” 8.0” x 2.25” x 1.25” 7.0” x 3.2” x 2.2”
11.2 oz 8.0 oz 3.2 oz
CE
IEC 1010-1
CE
IEC 1010-1