Introduction
We are confident you will find
many uses for your ProTemp 6
hand-held, non-contact
thermometer. Compact, rugged,
and easy to use—just aim, push
the button, and read current
surface temperatures in less than
a second. You can safely
measure surface temperatures of
hot, hazardous, or hard-to-reach
objects without contact.
How it Works
Infrared thermometers measure the surface
temperature of an object. The unit’s optics sense
emitted, reflected, and transmitted energy, which
is collected and focused onto a detector. The
unit’s electronics translate the information into a
temperature reading which is displayed on the
unit. The built in laser aids in pointing the
thermometer by identifying the center of the
measurement area.
How to Operate the Unit
1) °C / °F and Battery
To switch between Celsius or Fahrenheit, slide
switch (A) to select C or F. When necessary,
replace the 9v battery as shown in diagram.
3
2
1
2) Display
1) Battery Gauge
2) Hold Icon
3) Measurement in Process
4) Temperature Units
5) Measured Temperature
3) Operating the Unit
To measure a temperature, point the ProTemp 6
at the object or surface to be measured and
press and hold the ProTemp 6’s “On” button.
The pointing laser will be activated. Point it at
the areas to be measured. The laser identifies
the center of the area.
The display of the ProTemp 6 will light up (this is
only visible in reduced lighting), the “Battery
Gauge” will indicate the state of charge of the
battery, the “Measurement in Process” icon will
oscillate, and the measured temperature will be
displayed (in °C or °F, as selected by the user).
Release the “On” button. The “Hold” icon will
light and the “Measurement in Process” icon will
go off. The ProTemp 6 will hold and display the
previously measured temperature for about 7
seconds, and then turn itself off.
4
5
How to Accurately
Measure Temperatures
1) Locating a Hot Spot
To find a hop spot aim the thermometer outside
the area of interests, then scan across with an up
and down motion until you locate the hot spot.
2) Distance & Spot Size
As the distance (D) from the object increases the
spot size (S) of the area measured by the unit
becomes larger.
3) Field of View
Make sure that the target is larger than the unit’s
spot size. The smaller the target, the closer you
should be to it. When accuracy is critical, make
sure the target is at least twice as large as the
spot size.
4) Cautions
All models should be protected from the
following:
• EMF (electro-magnetic fields) from arc
welders, induction heaters,
• Static electricity
• Thermal shock (caused by large or abrupt
ambient temperature changes—allow 30
minutes for unit to stabilize before use)
• Do not leave the unit on or near objects of
high temperature.

WARNING!!!
Do not point laser directly at eye or view
indirectly off reflective surfaces.
5) Reminders
Not recommended for use in measuring shiny or
polished metal surfaces (stainless steel, aluminum,
etc.) See Emissivity.
6) Emissivity
Most organic materials and painted or oxidized
surfaces have an Emissivity of 0.95 (preset in the
unit). Inaccurate readings will result from
measuring shiny or polished metal surfaces. To
compensate, cover the surface to be measured
with masking tape or flat black paint. Allow time
for the tape to reach the same temperature as the
material underneath it. Measure the temperature
of the tape or painted surface.
7) Maintenance
Lens Cleaning: Blow off loose particles using clean
compressed air. Gently brush remaining debris
away with a camel’s hair brush. Carefully wipe the
surface with a moist cotton swab. The swab may
be moistened with water. NOTE: DO NOT use
solvents to clean the plastic lens. Case Cleaning:
Use soap and water on a damp sponge or soft clot.
NOTE: DO NOT submerge the unit in water.
CE Certification
This instrument conforms to the following
standards:
*En50081-1:1992, Electromagnetic Emissions
*En50082-1:1992, Electromagnetic Susceptibility
Applications for the ProTemp 6
1. Industrial/Electrical
Check for hot spots in electrical panels and
circuit breakers, generators and gearboxes.
2. Heating and Air Conditioning
Check and monitor supply and return registers,
air stratification and duct leakage
3. Automotive
Check cylinder heads, heating & cooling
systems, and scan radiators for blockage
4. Food Safety
Monitor temperatures for HACCP requirements
during receiving, storage and preparation
Specifications
Temperature Range: 0° to 605°F (-18° to 315°C)
Operating Temperature: 50° to 125°F (10° to
52°C)
Resolution: 1
Accuracy:
77° to 500°F (25° to 260°C) ± 2% of rdg or 3°F
°
C) plus one digit, whichever is greater
(2
30° to 76°F (0° to 24°C) ± 3% of rdg or 5°F (3°C)
0° to 29°F (-18° to -1°C) ± 4% of rdg or 7°F (4°C)
Response Time: 500 mSec, 95% Response
Tar get Size/Field of View:
1” minimum target
Repeatability: 2% of reading, or 3
Spectral Response: 7-18 um
Emissivity: Fixed at 0.95
Relative Humidity: 10-95% RH noncondensing,
@ up to 86
Storage Temperature: -4° F to 150° F
°
(-20
Battery: 1 - 9 volt Alkaline Battery
Battery Life: 12 Hours Continuous Operation
Dimensions: 7.25” x 1.75” x 1.5”
Weight: 4.8 oz.
Triplett Model ProTemp 6
Cat. No.: PT6
Made in China
°
F (1°C)
6:1 optics ratio with a
°
F (30°C)
to 65°C) without battery
°
F (2°C)
Triplett One Year Limited Warranty
The Triplett Corporation warrants instruments and test equipment
manufactured by it to be free from defective material or workmanship
and agrees to repair or replace such products which, under normal
use and service, disclose the defect to be the fault of our
manufacturing, with no charge within one year of the date of original
purchase for parts and labor. If we are unable to repair or replace the
product, we will make a refund of the purchase price. Consult the
Instruction Manual for instructions regarding the proper use and
servicing of instruments and test equipment. Our obligation under
this warranty is limited to repairing, replacing, or making refund on
any instrument or test equipment which proves to be defective within
three years from the date of original purchase.
This warranty does not apply to any of our products which have been
repaired or altered by unauthorized persons in any way so as, in our
sole judgment, to injure their stability or reliability, or which have been
subject to misuse, abuse, misapplication, negligence, accident or
which have had the serial numbers altered, defaced, or removed.
Accessories, including batteries and fuses, not of our manufacture
used with this product are not covered by this warranty.
To register a claim under the provisions of this warranty, contact Triplett
Corporation’s Customer Service Department for a Return Authorization
Number (RMA) and return instructions. No returned product will
be accepted without an RMA number. Upon our inspection of the
product, we will advise you as to the disposition of your claim.
ALL WARRANTIES IMPLIED BY LAW ARE HEREBY LIMITED TO A
PERIOD OF ONE YEAR FROM DATE OF PURCHASE, AND THE
PROVISIONS OF THE WARRANTY ARE EXPRESSLY IN LIEU OF
ANY OTHER WARRANTIES EXPRESSED OR IMPLIED.
The purchaser agrees to assume all liability for any damages and
bodily injury which may result from the use or misuse of the product
by the purchaser, his employees, or others, and the remedies provided
for in this warranty are expressly in lieu of any other liability Triplett
Corporation may have, including incidental or consequential damages.
Some states (USA ONLY) do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or
exclusion may not apply to you. No representative of Triplett
Corporation or any other person is authorized to extend the liability
of Triplett Corporation in connection with the sale of its products
beyond the terms hereof.
Triplett Corporation reserves the right to discontinue models at any
time, or change specifications, price or design, without notice and
without incurring any obligation.
This warranty gives you specific legal rights, and you may have
other rights which vary from state to state.
TRIPLETT PRODUCT RETURN INSTRUCTIONS
In the unlikely event that you must return your ProTemp 6
for repair,the following steps must be taken.
1) Call 1-800-TRIPLETT to obtain a Return Material Authorization
(RMA) number from Customer Service.
2) Enclose a copy of the original sales receipt showing date of purchase.
3) Clearly print the RMA number on the outside of the shipping container.
4) Return to: Triplett Corporation
One Triplett Drive
Bluffton, OH 45817
ATTN: Repair Dept.
Triplett Corporation One Triplett Drive Bluffton, OH 45817
800-TRIPLETT FAX: 419-358-7956 www.triplett.com
Be sure to include a full description of the
problem, and a telephone number, street
address, or email address, where you can
be contacted, and a return address where
the meter can be shipped to upon repair.
© Triplett Corporation All Rights Reserved