To Clean and Inspect ...............................................................................................................................................11
To Check for Leaks ..................................................................................................................................................11
To Clean Spray Nozzle ........................................................................................................................................... 12
To Clean Solenoid Valve ......................................................................................................................................... 13
Unit Diagram and Parts List........................................................................................................................................... 14
Read this manual carefully and completely before installing this
product. Installation and maintenance should be
completed by qualied personnel.
2www.trioniaq.com
Caution:
Mister-
MINI
®
Humidifier
Page 3
Installation, Operation, & Maintenance Manual
Introduction
The benets of a properly humidied environment (35-50% Relative Humidity) are many. They include both personal
comfort as well as the preservation of furniture, draperies, carpets, wooden oors and cabinets, paintings, pianos,
etc. Your home can be more comfortable at a lower temperature (i.e.: 68° F) at 35-50% Relative Humidity (RH)
than at 71° to 72° F without controlled humidity. Since every degree of temperature setback represents about 3%
of your heating costs, this can possibly represent a signicant annual savings. During the heating season, cold
air inltrates the home and must be heated. When heated, this air dries out and greatly increases its capacity to
hold more moisture. By using a humidier, a source of water is provided to satisfy this increased moisture holding
capability, rather than having it drawn from our body surface and the surrounding furnishings in the home.
DO NOT install the humidier where freezing conditions could
occur or where accidental overow could cause water damage to
the home or property.
For any installation in areas where water damage could occur,
always install a drain safety pan, plumbed to a suitable drain.
Specications
ModelMister-MINI
Type of UnitAtomizing/Evaporative
Duct PositionSupply Duct
GPD @ 140°F12.5 Gallons per day @ 60 psi
GPD @ 120°F12.5 Gallons per day @ 60 psi
GPD @ 100°FNot Recommended for Temperatures <120°F
Voltage24 VAC 3 watt 0.125a
Unit Dimensions4.25"W x 3.88" D x 4.25" H
Duct Opening3.125" W x 3.125" H
Shipping Weight3 lbs
What's in the box(1) Humidier
(1) Wall/Duct Mount Humidistat
(1) Instruction Manual
(1) Mounting Template
Features5-Year Warranty
Mister-
MINI
®
Humidifier
www.trioniaq.com
3
Page 4
Installation, Operation, & Maintenance Manual
Capacity Selection
The table below is for reference only and is based upon the following:
Inside temperature of 70°F / 35% relative humidity
Outside temperature of 20°F / 70% relative humidity
8 foot ceiling height
Internal moisture gain of one pound per hour
Furnace on-time 70%
The chart uses Standard ASHRAE denitions:
A “Tight Home” is assumed to be well insulated with vapor barriers, tight storm windows and doors, and a dampered
replace. Air exchange rate of .5 changes per hour.
An “Average Home” is insulated and has a dampered re place, but there are no vapor barriers, storm doors, or
storm windows. Air exchange rate of 1.0 changes per hour.
A “Loose Home” is generally one constructed before 1930, has little or no insulation, no storm doors, storm windows,
weather stripping or vapor barriers, and often no effective dampering of replaces. Air exchange rate is as high as
1.5 changes per hour
Sq. Footage of
Home
10000.55.010.0
15003.010.016.5
20005.014.024.0
25007.519.030.5
300010.023.537.5
400014.533.051.5
Tight Home
(GPD)
Average Home
(GPD)
Loose Home
(GPD)
4www.trioniaq.com
Mister-
MINI
®
Humidifier
Page 5
Installation, Operation, & Maintenance Manual
Output Capacity
Increasing or decreasing the nozzle size or supply water pressure can vary the output capacity of this humidier. It
is recommended that the humidier NOT be used with water pressures below 40 PSI, otherwise, the mist may be
adversely affected.
This humidier comes standard with a .75 GPH (oil) nozzle with a hollow spray pattern. Alternatively sized nozzles
may be purchased from your local HVAC supply house or plumbing supply outlet. If the water pressure uctuates or is
excessive, a pressure regulator should be installed in the water line supplying the humidier.
The following chart illustrates the capacity of different nozzles at varying water pressures. The capacity listed on the
nozzle is for #2 fuel oil at 100 psi and should not be considered relative to the water capacity of this humidier.
Nozzle
Pressure
(PSI)
400.235.50.286.80.4310.20.5713.7
450.245.80.307.20.4510.90.6014.5
500.256.10.327.60.4811.50.6415.3
550.276.40.338.00.5012.00.6716.0
600.286.70.358.40.5212.50.7016.7
650.297.00.368.70.5413.10.7317.4
700.307.20.389.00.5613.60.7518.1
750.317.50.399.40.5814.00.7818.7
800.327.70.409.70.6014.50.8019.3
850.338.00.4110.00.6214.90.8319.9
900.348.20.4310.20.6415.40.8520.5
950.358.40.4410.50.6615.80.8821.1
1000.368.60.4510.80.6816.20.9021.6
NOTE:
Due to the operation cycle of the furnace and humidier, it may take from 2-5 days to reach the proper
humidication level.
0.40.50.751
GPHGPDGPHGPDGPHGPDGPHGPD
Nozzle Size
Mister-
MINI
®
Humidifier
www.trioniaq.com
5
Page 6
Installation, Operation, & Maintenance Manual
Installation
When selecting a location for the installation of your humidier, certain
conditions must be met for its proper operation. The recommended location
for this humidier is on the warm air supply plenum, approximately 3 inches
downstream of the furnace discharge. The air temperature must be at least
120ºF in order for the temperature switch to operate properly. In narrow plenum/
duct arrangements, the humidier should be mounted on the narrow side of the
duct. Select a location so that the spray from the nozzle will not impinge on the
furnace fan, control switches, air conditioning or heat coils, or walls of the duct.
The humidier should be mounted so that the furnace air carries the mist away
from the humidier temperature switch. The direction of airow is indicated inside
of the humidier housing and on the rating label on the side of the humidier.
DO NOT install the humidier where freezing conditions could occur or where
accidental overow could cause water damage to the home or property.
DO NOT install the humidier where the temperature will exceed 180°F.
Excessive heat may cause softening and distortion of the plastic housing.The
installation of a water lter may reduce the potential clogging of the nozzle and
solenoid valve in hard water applications.
Nozzle
Supply Plenum
Nozzle
Supply Plenum
Temperature
Switch
Furnace
Temperature
Switch
Furnace
6www.trioniaq.com
Temperature
Switch
Furnace
Mister-
MINI
Supply Plenum
Nozzle
®
Humidifier
Page 7
Installation, Operation, & Maintenance Manual
Installation
Remember to select a location that is readily accessible for periodic inspection and cleaning of your humidier.
Mounting:
1. Read the instructions carefully prior to installing this product to ensure safe operation. Failure to follow these instructions could damage the humidier or cause a hazardous condition. Property damage may result from improper
installation.
2. Check the ratings given on the product to make sure it is suitable for your application. Do not install this product on
heat pump systems.
3. Tape the template (included inside the carton) in place on the duct.
4. Drill the (4) 1/8” diameter holes as indicated. These are used to secure the unit to the duct
5. Neatly cut out the 3 1/8" x 3 1/8" opening according to the "cut out on line" indicator on the template. A portion of the
unit will be inserted through this opening.
6. Remove all sharp edges and burrs to prevent damage to the unit or injury to yourself.
7. Remove the screw on the unit that secures the cover & nozzle assembly and pull back on the water tting to release
the humidier cover from the housing. All of the components inside of the unit are attached to the cover and will
come off with the cover.
8. Mount the unit housing with gasket (included) to the duct using the (4) mounting screws (included). Please refer to
the illustration on the next page for reference.
Mister-
MINI
®
Humidifier
www.trioniaq.com
7
Page 8
Installation, Operation, & Maintenance Manual
Installation
Standard Wiring
This humidier is intended to be wired directly to the integrated control panel on your furnace. The electrical tap will
provide power to the humidier whenever the circulating air blower is in operation.
Read the instructions in the furnace installation manual carefully before attempting installation or operation of the humidi-
er. Failure to follow these instructions may result in improper installation and therefore, void the manufacturer's warranty.
The solenoid valve provided with the Mister-MINI is designed for 24VAC operation. Ensure that the proper diagram is
used to connect power to the unit and humidistat.
FURNACE
24VAC
COMMON
8www.trioniaq.com
Mister-
MINI
®
Humidifier
Page 9
Installation, Operation, & Maintenance Manual
Installation
Optional Wiring
Electrical Connections (24 VAC)
Plumbing - USE COPPER WATER TUBING ONLY:
1. Install a saddle valve (not included) to a source of water per the instructions printed on the saddle valve package.
2. Fasten a copper water line (not included) of sufcient length to reach from the humidier to the saddle valve.
3. With the end of the copper water line pointing into a bucket or pan, turn on the saddle valve to wash the tubing of any debris
that may get stuck in the solenoid valve seat or clog the spray nozzle. When nished, turn the saddle valve off again.
4. Cut off any excess length of copper water tubing and connect it to the humidier using the nut and ferrule provided on
the humidier. Slide the nut onto the copper water tubing and then slide the ferrule onto the water tubing. Assemble
the nut to the compression tting on the humidier by turning it clockwise 1 ¼ to 1 ½ turns past hand-tight to seal.
5. Turn the saddle valve back on and check the humidier and tubing for leaks.
Nut & Ferrule
supplied with saddle
valve (not included
with humidier)
Copper
Tubing
Compression
Nut
Brass
Ferrule
Mister-
MINI
®
Humidifier
1/4”
Compression
Fitting
www.trioniaq.com
9
Page 10
Installation, Operation, & Maintenance Manual
Operation
Overview:
Your atomizing mister type humidier operates by dispersing a ne mist into the warm air plenum of your furnace. The
water is then evaporated and carried into the home by the furnace air ow. This humidier is recommended for areas
where water mineral content is low. Otherwise, a ne accumulation of white dust may occur in either the ducts or liv-
ing areas. High mineral content will also clog the nozzle causing an uneven spray pattern, excessive dripping, or total
blockage of the nozzle tip. When wired properly, the humidier will operate only when the plenum temperature rises to
the internal thermostat setting, the humidistat senses a need for humidity, and the furnace blower is in operation. The
internal thermostat controls the temperature at which the humidier will turn on. The humidier should activate after the
furnace blower comes on and shut off before the furnace blower turns off. If this does not occur, readjust the furnace
fan switch as required. If applicable, set the humidistat in the recommended range of 35-50% Relative Humidity for
automatic humidity control during the heating season (a lower setting may be used to control condensation on single
pane windows). Due to the operation cycle of the furnace and humidier, it may take two to ve days to reach the proper
humidication level.
Start-up & Operation:
1. Adjust the humidistat to the ON position and turn the furnace on.
2. Adjust the house thermostat to cause the furnace to operate. The heat and blower should turn on BEFORE the
humidier.
3. The solenoid valve will make an audible click when it operates, either on or off.
4. If necessary, adjust the furnace fan control to a lower setting to allow the blower to turn on before the humidier
turns on and the blower turns off after the humidier is off.
5. Readjust the humidistat to the desired setting (35-50% Relative Humidity is recommended).
6. If condensation occurs on windows, lower the humidistat setting until the condensation has disappeared.
Recommeded Relative Hu-
midity Level vs. Outside Air
Temperature
Outside
Temperature
40°F45% RH
30°F40% RH
20°F35% RH
10°F30% RH
0°F25% RH
Recommended
Set-point
NOTE: When shutting the humdier down for the summer months, turn off
the water and clean any mineral accumulation from the unit. Leave the water
turned off. If the furnace fan is to be used for cooling purposes, disconnect
power to the humidier or turn the humidistat to the OFF position if applicable.
10www.trioniaq.com
Mister-
MINI
®
Humidifier
Page 11
Installation, Operation, & Maintenance Manual
Maintenance
Like your heating system and air conditioning unit, periodic maintenance and cleaning are required to ensure the safe
and efcient operation of your humidier. To improve the efciency of your humidier, and to reduce the possibility of a
health hazard, it is recommended that you take the following precautions:
• Follow the manufacturer’s recommended cleaning and maintenance instructions.
• The amount of minerals and other impurities in a water source can vary greatly, therefore the frequency of cleaning
the humidier also varies.
• During the heating season, check for lm or scale build-up on the atomizing nozzle on a monthly basis. Establish a
proper cleaning schedule to ensure the efciency of the humidier.
• At the end of the winter humidication season, drain and thoroughly clean the humidier.
NOTE: The necessity to clean your humidier is substantially the result of impurities coming in through your water supply which feeds the humidier. Other household dust, containing biological and microbial contaminants can nd its way
into the air handling system and ultimately, the humidier. The humidier is not the source of these impurities.
To clean and inspect the unit:
1. Turn the power to the furnace OFF.
2. Turn the humidistat to the OFF position.
3. Turn the water off at the saddle valve and remove the water tubing from the humider.
4. With the open end of the water line directed into a bucket or pan, turn on the water at the saddle valve to void the
water line of any debris or particulates.
5. Remove the screw securing the unit cover to the housing and swing the cover down to gain access to the nozzle.
6. Carefully remove the nozzle from the adapter and proceed to clean the spray nozzle section.
7. Replace the spray nozzle with a clean one or new one of the same size and capacity as initially provided with the
unit. Use care and secure tightly.
8. Swing the cover into place and fasten with screw.
9. Restore the water supply to the humidier by reversing step 3.
To check for leaks:
1. Turn the furnace and humidistat on and ensure that the humidifer has operated for at least one minute.
2. Remove the screw securing the cover to the housing and check nozzle for leakage.
3. If there is no leakage, return the unit to its original position and secure with screw.
4. After completing the cleaning, operate the solenoid to be sure it's operating properly.
Mister-
MINI
®
Humidifier
www.trioniaq.com
11
Page 12
Installation, Operation, & Maintenance Manual
Maintenance
The following symptoms indicate that the spray nozzle requires cleaning or replacement. For best performance, nozzle
should be replaced in lieu of cleaning.
• Larger spray pattern
• Non symmetrical spray pattern
• Constant water stream
• Not spraying water
To Clean the Spray Nozzle
1. Turn the power to the furnace OFF.
2. Turn the humidistat to the lowest position.
3. Turn off the water supply at the saddle valve.
4. Remove the screw securing the cover of the humidier to the housing.
5. Remove the cover assembly from the humidier by tilting outward.
6. Be careful not to kink the water supply line or cause undue strain on the wiring.
7. Hold the nozzle adapter with a 3/4” wrench and using a 5/8” wrench, turn the spray nozzle counter clockwise and
remove the nozzle.
8. Remove the screen from the nozzle by turning it counter clockwise.
9. Holding the spray nozzle with the 5/8” wrench, insert a 5/32” allen wrench into the set screw and turn it counter
clockwise and remove the components.
10. Rinse and clean all parts. Suggested cleaners include 50/50 solution of white vinegar and water or liquid humidier
cleaner.
11. Using a razor blade, carefully clean the (4) slots on the director (see diagram below).
12. Reassemble the nozzle assembly, paying careful attention to the diagram below for the correct replacement of
parts.
13. After completing the assembly, operate the unit to be sure it is functioning properly.
NOTE: It is recommened that the nozzle be replaced annually to avoid mineral build-up and possible clogging. Upon
replacing the nozzle, check thoroughly for leaks.
Nozzle Body
12www.trioniaq.com
O-ring
Slots
Strainer ScreenDirector
Mister-
MINI
®
Humidifier
Page 13
Installation, Operation, & Maintenance Manual
Maintenance
The following symptoms indicate that cleaning the solenoid valve is required:
• Sluggish valve operation
• Excessive noise
• Constant water spray
• Streaming water
To clean the solenoid valve:
1. Turn the power to the furnace OFF.
2. Turn the humidistat to the lowest position.
3. Turn off the water supply at the saddle valve.
4. Remove the screw securing the cover of the humidier to the housing.
5. Remove the cover assembly from the humidier by tilting outward.
6. Be careful not to kink the water supply line or cause undue strain on the wiring.
7. Remove the solenoid valve assembly from the cover using a Phillips head screwdriver.
8. Using a 3/4” wrench, remove the brass nozzle adapter from the OUT port of the valve body. Remove the compression
tting from the IN port of the valve.
9. Remove the coil from the assembly by turning the valve body counter clockwise.
10. Clean and remove all particulates from the brass ttings, lter, plunger/spring assembly and orices in the valve
body using a 50/50 solution of white vinegar and water.
11. Reassemble the parts, paying careful attention to the diagram below for the correct placement.
12. After completing the assembly, operate the unit to be sure it is functioning properly and check for leaks.
Coil Assembly
Mister-
MINI
®
Humidifier
Plunger
SpringO-Ring
Solenoid Valve Assembly
1/8” NPT to 1/4”
Brass Compression
Fitting
Valve Body
www.trioniaq.com
13
Page 14
Installation, Operation, & Maintenance Manual
Unit Diagram
15
7
3
1
12
9
2
4
8
5
6
10
QTY.ITEM NO. PART NUMBER DESCRIPTION
11259959-001COVER
12265205-001THERMOSTAT
13266121-001G-109C SOLENOID VALVE ASSEMBLY
14266122-001WIRE ASSEMBLY
25EST-1434SCREW, SST MACH M4 x 6MM
26142983-003CHRISTMAS TREE CLIP
17AH-25⅛ NPT x ¼” COMPRESSION FITTING
1812006-01WATER NOZZLE W/FILTER
19160"O" RING
110259960-001CASE
111265165-001GROMMET
112165007-001NOZZLE ADAPTER
113265037-001GASKET MISTER-MINI (not shown)
114265160-001HUMIDISTAT, MECHANICAL (not shown)
1152034PHILLIPS SCREW #8 - 1/2" S/S
11
14www.trioniaq.com
Mister-
MINI
®
Humidifier
Page 15
Installation, Operation, & Maintenance Manual
Warranty
Humidier 5-Year Limited Warranty
This limited warranty covers Trion Residential Type Humidiers, excluding duct work, wiring and installation. Trion
warrants that all new Trion humidiers are free from defects in material and workmanship under normal, non-commercial
use and service. Trion will remedy any covered defects if they appear within 60 months from the date of original
installation & subject to the terms and conditions of this Limited 5-Year Warranty stated below:
1. THIS LIMITED 5-YEAR WARRANTY is granted by Trion Customer Service, 101 McNeill Road, Sanford, NC 27330.
2. This warranty shall extend only to any non-commercial owner who has purchased the residential humidier other than for
purposes of resale.
3. All components are covered by this limited warranty except expendable items, such as evaporative pads, media lter pads and
nozzles.
4. If, within the warranty period, any Trion residential humidier unit or component requires service it must be performed by a
competent heating and/or air conditioning contractor (preferably the installing contractor). Trion will not pay shipping charges,
or labor charges to remove or replace such defective parts or components. If the part or component is found by inspection to
contain such defective material and workmanship it will be either repaired or exchanged free of charge at Trion’s option, and
returned freight collect.
5. In order to obtain the benets of this limited 5-year warranty, the owner must notify the dealer or distributor of any defect within 30
days of its discovery. If after reasonable time you have not received an adequate response from the dealer or distributor, notify
in writing to Trion Customer Service 101 McNeill Road, Sanford, NC 27330, or call 1-800-884-0002 or email customerservice@
trioniaq.com Humidiers which have been installed or become part of real estate cannot be returned. Trion will receive, freight
prepaid, only removable parts or components of such defective humidiers.
6. This limited warranty does not apply to any part or component that is damaged in transit or in handling, has been subject to
misuse, neglect or accident; has not been installed, operated and serviced according to Trion’s instructions; has been operated
beyond the factory rated capacity; or altered in any such way that its performance is affected. There is no warranty due to
neglect, alteration or ordinary wear and tear. Trion’s liability is limited to replacement of defective parts or components and does
not include the payment of the cost of labor charges to remove or replace such defective components or parts.
7. Trion will not be responsible for loss of use of any product; loss of time, inconvenience, or any other indirect, incidental or
consequential damages with respect to person or property, whether as a result of breach of warranty, neglect or otherwise.
SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO
THE LIMITATION OR EXCLUSION IN THE PRECEDING SENTENCE MAY NOT APPLY TO YOU.
8. THIS WARRANTY GIVES YOU SPECIFIC RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM
STATE TO STATE.
9. Any warranty by Trion of merchantability, tness for use or any other warranty (express, implied or statutory), representation or
guarantee other than those set forth herein, shall expire at the expiration date of this express limited warranty. SOME STATES
DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE LIMITATION IN THE PRECEDING
SENTENCE MAY NOT APPLY TO YOU.
10. Trion reserves the right to make changes in the design and material of its products without incurring any obligation to incorporate
such changes in units completed on the effective date of such change.