![](/html/21/2126/21268b31b380c54e7bce71bcdddbf7cb7ab15a61c135586d9663084d25c67223/bg1.png)
QUICK START
Using the TS-PFS to Automatically
Totalize A Weighing Session
Prepare the Scale
1
Model TS-PFS
PORTABLE FEEDER SCALE
Power
On
Clear
The
Tot al
Weight
Memory
Verify
Scale’s
Status
Press the ON key. The scale will perform a
brief self-test.
PRESS AND HOLD THE RESET KEY UNTIL
“RESET” DISPLAYS. The scale will beep
once and show zeros.
As shown below, view the display to confirm that:
- No weight is indicated (memory has been reset)
- Arrows point to AUTO ADD and TOTAL WEIGHT*
- ZERO and STABLE icons are on.
Triner Scale and Manufacturing Co., Inc.
8411 Hacks Cross Road
Olive Branch, MS 38654
Toll Free: (800) 238-0152
Tel: (662) 890-2385
Fax: (662) 890-2386
Email: info@trinerscale.com
www.trinerscale.com
* If not, refer to the Users Guide index
for “Setting the Operating Mode”
Proceed With Weighing Session
2
• Place item on scale. BEEP indicates the item has
been weighed and added.
• Remove item from scale. BEEP BEEP indicates the
scale is ready for next item
• Place next item on scale. BEEP indicates the item has
The weight will display been weighed and added.
briefly, then the totalized
weight will display.
• Continue as above until Single and double beeps
completed. make it unnecessary to
The display will show constantly check the display
the totalized weight, even to confirm the scale’s status
when the scale is at rest.
NOTE: If the scale powers off, simply turn back on to continue,
or to view the totalized weight of the session.
Be sure to read the TS-PFS User’s Guide to become familiar with
all of the scale’s features and functions.
If for any reason the scale does not return
to “Zero” during a weigh session (as
indicated by a single beep), the scale
will not proceed with the session. If this
occurs, press the Zero key (with nothing