Trine 3000, 3234, 3234W, 3234WRS, 3234RS Series Manual

...
1440 Ferris Place · Bronx · New York· 10461-3699
Model Number: 3234 - Fail Secure
3234RS - Fail Safe
Model Number: 3234W - Fail Secure
3234WRS - Fail Safe
TRINE 3000 SERIES ELECTRIC RELEASES
Congratulations on the purchase of this quality TRINE security product.
This product has been designed to install easily, perform reliably, and provide years of trouble free security.
In order for this product to fulfill its objectives, certain steps must be performed by the installer, and certain site conditions must be satisfied.
Before proceeding with your installation, please review the following list of items. If you have any questions first please finish reading this document to see if the information you require is contained in this document, otherwise please call:
TRINE TECH SUPPORT (718) 829-2332 EXT. 425,
or visit the TRINE Website www.TrineOnline.com.
The TRINE Model #3234, #3234W & Model #3478 are designed for new installation or retrofitting into metal, wood and aluminum door frames. Be sure that you have ordered the correct TRINE strike for your application.
Model Number: 3478 - Fail Secure
3478RS - Fail Safe
STANDARD FEATURES
Face Plate - 3234, 2-3/4" x 1-1/8" 3234W, 3-3/4" x 1-1/4" 3478, 4-7/8" x 1-1/4"
Mortise Type - 1" backset (Smallest in the Industry)Durability - 500,000 Life CyclesHolding Force - 1,200 Pounds (Static Force)
- 70 ft-lb (Dynamic Force)
All stainless steel locking partsSolid Cast Latch - Stainless SteelCavity: Width 5/8", Height 1-1/8", Depth 1/2"Non-handedHeavy-duty latch springSilent OperationIntermittent Duty with the Standard versionsIntermittent and Continuous Duty with the LC versionsMicro Solenoid assemblyFail-Secure:(standard action) unlocks with powerFail-Safe: RS (reverse action) unlocks when power is off
FINISHES
3234 3234W
US3 (Polished Brass)
US4 (Satin Brass)
US10B (Dark Bronze)
US26 (Bright Chrome)
US26D (Satin Chrome)
US32D (Satin Stainless Steel)
    
3478
RECOMMENDED INSTALLATION SEQUENCE:
1. Verify strike is proper for the door into which it is to be installed.
2. Verify that you have all parts required to complete the installation.
3. Verify that the new electric release operates with the existing power supply/control circuit (retrofit applications); or verify that the new power supply/ control circuit operates the new electric release (new installations).
4. Locate and clearly mark the circuit breaker which provides ac power to your transformer/ power supply or that supplies power to the receptacle into which you will plug your transformer/power supply. This will enable you to safely cut power during installation, and permit troubleshooting if required.
5. Verify that the receptacle or circuit providing power to the electric release is not controlled by a wall switch, time clock, or other external device.
6. Verify that the circuit/receptacle used for the locking system is not powering any other equipment. Remember that interruption of power to your locking system could prevent access into the protected area, or jeopardize the security/safety of the site's occupants.
7. Verify that the door and associated components are in good working order.
8. Install electric release as per attached guidelines.
9. Wire electric release as per attached guidelines.
10. Perform final test of completed installation.
LUBRICATION: The TRINE Model #3234, #3234W & #3478 do not require lubrication. Lubricating these units will actually
hamper their performance by attracting dust and debris into the tight tolerance precision Micro Solenoid assembly.
GETTING STARTED: Before proceeding with your installation, verify that the door to which the electric release is being applied is in good working condition.
DUTY & VOLTAGES: The TRINE Model #3234, #3234W & Model #3478 are available as FAIL-SECURE (Normally Locked, Power to Unlock), INTERMITTENT DUTY and are supplied in two different operating voltage and the LC VERSION, suitable for use in a range of voltages from 12V to 24V AC or DC. The TRINE Model #3234RS, 3234WRS & Model #3478RS are FAIL­SAFE (Normally Unlocked, Power to Lock), continuous duty and are supplied with LC module.
These items are essential for either new installations or retrofits Items which should be specifically checked prior to beginning the installation include:
The hinges (or pivots) are in good conditionIf your installation is a retrofit, that the existing latch
lines up perfectly with the existing strike plate. The door is not rubbing on the saddle or anywhere on the frame The door closer is not leaking and is in good condition and properly adjusted. The door is not warped or otherwise damaged which might hamper its operation or otherwise affect your installation or the final system's performance. That the door frame member into which the door release is to be installed is deep enough (1 inch) for the body of the electric strike, and that the wiring to operate the electric release can be installed for your application.
HANDING: The TRINE Model #3234, #3234W and #3478 are non-handed.
DOOR HANDING GUIDE
LEFT HAND (LH)
OUTSIDE
RIGHT HAND
(RH)
LC units will operate on any input voltage from 12V to 24V AC or DC, and offer both the benefits of reducing inventory by enabling you to stock one strike. In addition, they offer both
surge suppression and inductive kickback protection.
Please refer to the accompanying VOLTAGE DROP CHART for recommended wire gauges for various voltages and wire lengths.
VOLTAGE DROP GUIDE
Length to Transformer 12V 24V
Up to 50 feet 18 AWG 20 AW
50 to 150 feet 16 AWG 18 AW
150 to 300 feet 14 AWG 16 AW
300 to 600 feet 12 AWG 14 AW
G
G
G
G
The TRINE MODEL # 3234, #3234W and #3478: FAIL-SECURE "INTERMITTENT DUTY" units are designed for
momentary application of voltage for access control purposes, and cannot be continuously powered without permanent and irreversible damage to the electric strike's solenoid.
The TRINE MODEL #3234-RS, #3234W-RS and #3478-RS: FAIL-SAFE "CONTINUOUS DUTY" versions may be used for
applications where the release must remain UNLOCKED for extended periods. Please contact TRINE for other additional TRINE electric release solutions for those applications requiring a continuous duty FAIL-SECURE electric release that may be powered for extended periods, commonly referred to as CONTINUOUS DUTY.
LEFT HAND REVERSE BEVEL (LRB)
HANDING OF DOOR IS ALWAYS DETERMINED
OUTSIDE
REVERSE BEVEL
FROM THE OUTSIDE.
3000 SERIES ELECTRICAL CHARACTERISTICS CHART:
VOLTAGE CURRENT (AMPS)
12V DC 0.480 25 Int Silent Blue-Blue ST
24V DC 0.240 100 Int Silent White-White ST
VOLTAGE
12V DC 0.743/0.298 13 Int./Cont. Silent Red-Red
12V AC 0.715/0.277 13 Int./Cont. Silent Red-Red
24V DC 0.397/0.170 13 Int./Cont. Silent Red-Red
24V AC
Page 2
CURRENT (AMPS) PULL-IN/HOLDING
0.378/0.173 13 Int./Cont. Silent Red-Red
RIGHT HAND
(RRB)
RESISTANCE
RESISTANCE
STANDARD MODELS
COIL
(OHMS)
DUTY AUDIBLE SOUND WIRE COLOR
LC & RS MODELS
COIL
(OHMS)
DUT
The TRINE LC version of MODEL # 3234, 3234W, #3478, # 3234-RS, #3234W-RS and #3478-RS can be used for "INTERMITTENT DUTY" AND "CONTINUOUS DUTY"
MODEL
D
D
Y AUDIBLE SOUND WIRE COLOR
MODEL
LC
LC
LC
LC
ELECTRICAL: If you are performing a new installation, be certain that you make provisions for the proper voltage power supply for your electric strike. If you are performing a retrofit type installation, determine that the voltage present at the location of the strike is appropriate for the TRINE strike you have, that the circuitry supplying the voltage is operating properly, and also verify that you are able to cut the power completely to the door location so that you may perform the installation safely without endangering yourself or causing damage to the power supply or other devices connected to the circuit. It is strongly recommended that you also test for high voltages which may exist between each lead of the power wiring to the electric release solenoid, and to the door frame which is an earth ground. Dangerous voltages or currents may occur due to a miswire or other pre-existing fault conditions in the system you are servicing.
TESTING YOUR ELECTRIC STRIKE; POWER SUPPLY; & SWITCHING CIRCUIT PRIOR TO FINAL MOUNTING OF THE ELECTRIC RELEASE IS RECOMMENDED
POWER SOURCES:
The TRINE MODEL #5208 (12 VDC) or MODEL # 5209 (24 VDC) are suitable DC POWER SUPPLIES which are plug-in and therefore do not require that the installer perform line voltage wiring. TRINE offers several low voltage transformers suitable for use with the TRINE MODEL #3234, #3234W & #3478 electric releases.
HARDWIRED POWER SUPPLY MODELS are also available ­see our website or call our Customer Support Line for details.
SILENT OPERATION: The TRINE #3234, #3234W & #3478 are referred to as "Silent Operating"; unlike some types of AC electric releases which make a "buzzing sound" when activated. For some applications, such as entrances into apartment buildings or storerooms, an audible sound is desirable, and
even expected. For other applications, such as offices, silent operation is preferred because a buzzing sound is distracting or disturbing. Verify with your client which they require, and if an audible signal when the electric release is activated is desirable, then add a sounding device as shown in the accompanying wiring diagrams.
CONFIRMING PROPER LOCK-LATCH ENGAGEMENT & CLEARANCES:
The latch and the lock must engage properly for the electric strike to operate as intended. On doors where the gap between the edge of the door and the jamb are within standard tol­erances and the latch is the proper length, no adjustments will be required and this is true for the majority of installations.
But too little lock-latch engagement will result in an installation were the door may be easily spread; allowing the locked door to be forced open.
Too much lock-latch engagement will result in a situation where the door release will interfere with the door latch, causing binding; improper operation and premature mechanical wear on the latch and release.
Extended latch length (LL) minus the gap (G) between the edge of the door and the edge of the jamb equals the amount of lock­latch engagement.
"Lock-Latch Engagement = LL - G"
INSTALLATION OF SHIM:
An adequate amount of clearance must exist between the door latch and the strike keeper so that they do not interfere or bind when the door opens or closes. Two 1/16" thick shims are supplied with the TRINE #3234, #3234W and #3478 which may be installed as shown in the "Installation Drawings section" to resolve this situation if this problem is encountered. (also See Figure 4 below).
LOCK - LATCH
ENGAGEMENT
LOCK
LATCH
Page 3
FIGURE 4
LOCK - LATCH ENGAGEMENT
LOCK
LATCH
SHIM
METAL AND WOOD FRAME INSTALLATION
The 3478's 4-7/8" x 1-1/4" faceplate requires the least amount of jamb preparation when compared with other electric strikes.
3 3/8"
1 3/8"
1 1/4"
7/16"
INSTALLATION DRAWINGS
1 1/4"
1 1/4"
1 13/16"
1 3/4"
1 1/4"
1 1/32"
1 11/16"
3/32"
OPTIONAL 1/16" THICK SHIM
1 1/4"
3/4"
1 7/8"
4 7/8"
1 1/8"
4 7/8"
1/8"
7/16"
1 1/4"
4 7/8"
3 3/8"
1 9/16"
3/4"
9/16"
1 1/16"
3/32"
WOOD FRAME INSTALLATION
The 3234W's 3-3/4" x 1-1/4" faceplate requires the
least amount of jamb preparation when compared
with other electric strikes.
1 1/4"
3/32"
1 5/16"
1 1/32"
3/8"
5/8"
1"
4 1/8"
3 11/32"
OPTIONAL 1/16" THICK SHIM
1 11/16"
3 3/4"
1 1/64"
1 1/16"
Page 4
1 5/16"
3/32"
1 11/16"
1"
5/16"
9/16"
1 1/8"
3 3/4"
3 1/8"
1 1/8"
INSTALLATION DRAWINGS (Continued)
METAL FRAME INSTALLATION
The 3234's 2-3/4" x 1-1/4" faceplate requires the
least amount of jamb preparation when compared
with other electric strikes.
1 7/16"
2 3/4"
5/8"
TO 120V AC LINE
** When wiring the optional buzzer, polarity must be observed. Connect the (+ or RED) positive wire to the (+) positive side of the circuit and the (- or BLACK) negative side wire terminal to the negative side of the circuit.
24V DC OR 12V DC
TRANSFORMER
1 1/32"
1 11/16"
5/16"
WIRING DIAGRAM
FIGURE 1
USING DC TRANSFORMER
+
PUSH
BUTTON
NORMALLY OPEN
-
1/8"
1"
BLACK
1 11/16"
1 1/8"
-
9/16"
+
RED
5/8"
2 1/8"
5/8"
1 7/16"
OPTIONAL 1/16" THICK SHIM
2 3/4"
FAIL-SECURE
ELECTRIC
STRIKE
24V OR 12V AC/DC
TRANSFORMER
TO 120V AC LINE
Page 5
FIGURE 2
FAIL-SAFE MODELS
PUSH
BUTTON
NORMALLY
CLOSED
OPTIONAL BUZZER
BZ-12 or BZ-24
LC100
OPTIONAL
+
-
LED
FAIL-SAFE
ELECTRIC
STRIKE
24V AC OR 12V AC
TRANSFORMER
WIRING DIAGRAM (continued)
FIGURE 3
USING AC TRANSFORMER
PUSH
BUTTON
NORMALLY OPEN
TO 120V AC LINE
* The rectifier can be positioned before of after the push button in the circuit. The LC module can ONLY be positioned after the push button as shown above.
** The LC100 module is wired-in like a rectifier and the above schematic will work also with a DC output transformer.
*** When wiring the optional buzzer, polarity must be observed. Connect the (+ or RED) positive wire to the (+) positive side of the circuit and the (- or BLACK) negative side wire terminal to the negative side of the circuit.
RECTIFIER*
or
LC100**
+
-
-
BLACK
OPTIONAL***
BUZZER
BZ-12 BZ-24
BZ-6 - for the LC Version
+
RED
FAIL-SECURE
ELECTRIC
STRIKE
TROUBLESHOOTING THE COMPLETED INSTALLATION:
SYMPTOM: Electric release is not actuating:
1. Verify proper voltage is present AT STRIKE. If voltage IS present: the strike may have been damaged during the installation, or dirt or debris may be preventing proper operation.
2. Verify for proper electric release coil resistance (REFER TO COIL ESISTANCE CHART), for either a short circuit or open circuit. Coil is NOT a serviceable part. Note that intermittent coils can only receive
power for 1 minute or less.
3. If voltage IS NOT present:
Verify Circuit breaker is on
Verify voltage at the transformer/power supply output.
Verify output from rectifier (if used)
Verify that there are no additional, unknown external switches or devices which may be interrupting
your circuit.
Check for damaged wiring or bad wire splices.
SYMPTOM: Door will not open but strike is working
Check for other locks on door
Check for proper lock-latch engagement (SEE SECTION: "CONFIRMING PROPER LOCK-LATCH
ENGAGEMENT & CLEARANCES").
Lock latch engagement may be not set correctly. (If proper clearance cannot be achieved by installing
a shim; a shorter lock latch may be required for your installation.)
Check for excessive backpressure on door release latch by following these steps: While observing the electric release and latch; apply enough pressure on the door so that the lock's latch does not press on the electric release's latch. If applying pressure as described does not cause any movement of the lock away form the latch, then there may be too much pressure on the electric release's latch. If electric release works properly while you are applying this pressure, then steps must taken to relieve this pressure. Possible remedies include:
Re-adjust (or install) a door closer
Remove door silencers
Correct excessive door warpage
Re-center electric release in jamb
Remove or trim weather stripping around the door
Page 6