Triangle Tube PA110 User guide

Page 1
Prestige Solo Features
• Light weight construction for wall mounting
• Approved for zero clearance to combustibles
• 2” PVC, CPVC, PP venting up to 45 equivalent feet
• 3” PVC, CPVC, PP, or AL29-4C venting up to 100 equivalent feet
• Limited 5 year warranty on parts, except igniter
• Limited 10 year warranty on heat exchanger
Engineering Submittal
Prestige Solo 110
ACVMax Control System
• Graphical display with 6 navigation buttons
• EZ Setup allows quick and easy boiler settings adjust­ment
• Presets allow quick configuration of 4 circulator out­puts
• Each circulator output is fully configurable for cus­tom applications
• Outdoor temperature reset to maximize efficiency
• Accepts two space heating call inputs with indepen­dent outdoor reset curves
• Simultaneously heat dual temperature heating sys­tems with built-in mixing valve control
• Domestic hot water priority with optional time-out
• Integrated cascade control for up to 6 Prestige boil­ers
• 0-10 VDC Modulation input
• Modbus building management system (BMS) inter­face, LonWorks® and BACnet® interface optional
• Adjustable warm weather shutdown
• Adjustable boiler freeze protection
• Logging function records sensor readings for sys­tem optimization and troubleshooting
• Describes lockouts in plain english and suggests solutions while storing last 8 errors
Standard Equipment
• 95% AFUE Efficiency
• ENERGY STAR Qualified
• ANSI Z21.13 and CSA 4.9 Boiler Standards Compliance
• ASME Boiler Certification – ASME “H” Stamp
• Low NOx operation exceeding SCAQMD 2012 regu­lations
Stainless Steel Fire Tube Heat Exchanger
• 439 Stainless Steel heat exchanger construction for corrosion resistance
• Low pressure drop minimizes circulator size
• High water content provides stable temperature control
• Self cleaning flue ways reduce maintenance
• Suitable for use with propylene glycol up to 50% concentration
Project / Location:_________________________________________________________________ Date: _______________
Consulting Engineer / Architect: _________________________________________________________________________
Mechanical Contractor: _________________________________________________________________________________
• Stainless steel premix burner
• Direct spark ignition with variable speed blower
• Full modulation with turndown ratio of 5.5:1
• Automatic air vent
• ASME 30 PSI pressure relief valve
• Integrated pressure and temperature gauge
• Outdoor temperature sensor
• Automatic low water cutoff feature with early warn­ing
• High temperature manual reset limit safety control
• Terminal block for circulator output
• Low voltage terminal strip with removable jumpers for manual or automatic reset limits
• Swing out control for easy access and servicing
• Alarm and flame status contacts
• Polypropylene condensate pan and internal flue pipe
• Polypropylene vent/air connections with test ports
1
2016-7 Prestige ACVMax Solo 110 SubmittalDate: 12/11/2017
Page 2
C
B
A
D
E
F
G
H
J
I
M
K
L
4
6
8
10
12
14
16
ressure Drop (Ft. W.C.)
Solo 110
0
2
45678910 11 1 2
P
Flow Rate (G PM)
Boiler Dimensions
Solo (('
Grundfos UPS15-58 F/FC - Spd 1
Grundfos UPS15-58 F/FC - Spd 2
Grundfos UPS15-58 F/FC - Spd 3
Letter Connection
3/4" NPSC
Side ViewFront View
A
B
C
D
E
F
G
H
Pressure Relief
Valve
3" Combustion
Air Inlet
3" Vent Outlet
1" NPT Boiler
Return
1/2" NPT Gas
Connection
1" NPT Boiler
Supply
Boiler Width
Boiler Height
3/4" NPSC
I
Pressure Relief
Valve
3" Combustion
J
Air Inlet &
3" Vent Outlet
K
1/2" NPT Gas
Connection
Dimension
in [mm]
16-5/8"
423]
[
15-13/16"
[402]
8-13/16"
[224]
2-7/8"
[73]
5-7/8"
[150]
16-7/16"
[418]
19-3/4"
[502]
36-9/16"
[928]
11-1/4"
[286]
5-9/16"
[141]
4"
[102]
Boiler Specifications
Model Fuel
Solo 110
Natural
Propane
Input
Modulation
(MBH)
AFUE
DOE Heating
Capacity (MBH)
Net
AHRI
(MBH)
Boiler Water
Volume (gal)
20 - 110 95% 102 89 2.1
Pressure Drop Curve vs Grundfos UPS 15-58-FC
2
L
M
1" NPT Boiler
Return & Supply
Boiler Depth
Power
120/1/60
FLA: 10A
13-7/16"
[341]
17-5/16"
[440]
Shipping Weight
Lbs
103
Loading...