Engineering Submittal
Keystone Water Heater
KW 199 - 850
Engineering Submittal Data
• High efficiency condensing water heater
• Electronic PID modulating control with large color
touchscreen display
• Displays holds, alerts, and errors in clear text
• Complete diagnostics for analog and digital inputs
•
Accepts external analog modulation signal
• Built-in cascade function for up to eight Keystone
water heaters
• Modulation down to 20% of full fire (5:1 turndown)
• Sealed combustion chamber
• Pre-mix stainless steel burner
• Low NOx - 2012 SCAQMD certified
• Horizontal or vertical direct vent
• Horizontal vent and air terminals
• Vent and combustion air pipe lengths of up to 100’
• Built-in condensate trap
• Vent temperature cutoff feature
• Direct spark ignition system
• 160 psi maximum working pressure
• Stainless steel heat exchanger with welded con-
struction (no gaskets)
• ASME “H” stamp
• 125 psi (861 kPa) ASME Rated pressure relief valve
• Water flow switch (KW 399 - 850 only)
• Temperature & pressure gauge
• Drain valve
• Alarm output
• On/off service switch
• Manual reset high temperature limit
• Burner site glass
• Zero clearance to combustible surfaces
• 5 year limited warranty on heat exchanger
1
2012-14 Keystone KW 199-850 SubmittalDate 4/13/17

Engineering Submittal - KW 199 - 850
Sizing Data
Model
Input
MBH [kW]
Output
MBH [kW]
Thermal
Efficiency
%
Gas Conn. Size
Inches
Water Conn.
Sizes
nches
I
KW 199 199 [58.3] 193 [56.5] 97 1/2 NPT 1 1/4 NPT 270 [123]
KW 285 285 [83.5] 271 [79.3] 95 3/4 NPT 2 NPT 299 [136]
KW 399 399 [116.9] 383 [112.2] 96 3/4 NPT 2 NPT 364 [165]
KW 500 500 [146.5] 480 [140.6] 96 1 NPT 2 NPT 419 [190]
KW 600 600 [175.8] 582 [170.4] 97 1 NPT 2 NPT 426 [193]
KW 750 750 [219.8] 705 [206.4] 94 1 1/2 NPT 2 NPT 481 [218]
KW 850 850 [249.1] 816 [238.9] 96 1 1/2 NPT 2 NPT 503 [228]
Vent System Data
Model Intake (Air) Pipe Exhaust (Vent) Pipe
KW 199 3” 3” 100 [30]
3” 3” 20 [6.1]
KW 285
4” 4” 100 [30]
Maximum Allowable Equivalent
Length* Ft [m]
Shipping
Weight
bs [Kg]
L
KW 399 4” 4” 100 [30]
KW 500 4” 4” 100 [30]
4” 4” 40 [12]
KW 600
6”** 6”** 100** [30]**
4” 4” 40 [12]
KW 750
6” 6” 100 [30]
4” 4” 40 [12]
KW 850
6” 6” 100 [30]
Installations in the U.S. require exhaust vent pipe that is a combination of PVC & CPVC complying with ANSI/ASTM D1785 F441, polypropylene
pipe that complies with ULC S636, or stainless steel complying with UL1738. Installations in Canada require exhaust vent pipe that is certified
to ULC S636.
Intake (air) pipe may be ABS, PVC, CPVC or galvanized material.
Installer must comply fully with manufacturer’s installation instructions, including use of minimum exhaust length CPVC, to maintain ANSI
Z21.13 safety certification.
Closet and alcove installations do not allow the use of PVC under any circumstances
* To calculate max equivalent length, measure the linear feet of the pipe, and add 5 feet (1.5m) for each elbow used.
** Allowed only if the vent pipe is no more than 20 equivalent feet longer than the air pipe.
2

Engineering Submittal - KW 199 - 850
Recovery Data
Required Water Temperature Rise GPH Delivered [L/H Delivered]
odel
M
KW 199
KW 285
KW 399
KW 500
KW 600
KW 750
KW 850
40°F
[22°C]
Flow gph
[L/h]
579
[2190]
818
[3091]
1153
[4359]
1451
[5485]
1729
[6536]
2170
[8203]
2434
[9201]
50°F
[28°C]
Flow gph
[L/h]
463
[1752]
654
[2473]
923
[3487]
1161
[4388]
1383
[5288]
1736
[6562]
1947
[7360]
60°F
[33°C]
Flow gph
[L/h]
386
[1460]
545
[2061]
769
[2906]
967
[3657]
1152
[4355]
1447
[5470]
1622
[6131]
70°F
[39°C]
Flow gph
[L/h]
331
[1251]
467
[1766]
659
[2491]
829
[3134]
988
[3735]
1240
[4687]
1391
[5258]
80°F
[44°C]
Flow gph
[L/h]
290
[1095]
409
[1545]
577
[2181]
726
[2743]
864
[3266]
1085
[4101]
1217
[4600]
90°F
[50°C]
Flow gph
[L/h]
257
[973]
363
[1374]
513
[1937]
645
[2438]
768
[2903]
964
[3644]
1082
[4090]
100°F
[56°C]
Flow gph
[L/h]
232
[876]
327
[1236]
461
[1744]
580
[2194]
691
[2612]
868
[3281]
973
[3678]
120°F
[67°C]
Flow gph
[L/h]
193
[730]
273
[1030]
384
[1453]
484
[1828]
576
[2177]
723
[2733]
811
[3066]
140°F
[78°C]
Flow gph
[L/h]
166
[626]
234
[883]
329
[1245]
415
[1567]
494
[1867]
620
[2344]
695
[2627]
Water Flow Requirements
Model
KW 199 25 [95] 28 [8.5] 15 [8]
KW 285 36 [98] 33 [10.1] 15 [8]
KW 399 50 [189] 35 [10.7] 15 [8]
KW 500 63 [239] 28 [8.5] 15 [8]
KW 600 60 [227] 24 [7.3] 19 [11]
KW 750 68 [257] 35 [10.7] 21 [12]
KW 850 68 [257] 26 [7.9] 24 [13]
Flow
gpm [lpm]
H/L
feet [m]
Temp Rise
°F [°C]
Note: Maximum allowed Water
Hardness of 10 grains per gallon
3

Engineering Submittal - KW 199 - 850
Air Inlet*
Keystone is shipped with adapters for the air and vent connections that accept standard pipe of the proper size and type.
Ve n t*
Return
Supply
Gas Inlet
PRV
E
GC
M
J
F
K
A
24 1/2
64
L
38
97
D
8 3/4
22
B
Top View
Front View
Right Side View
Model
A
KW285
KW399
in cm
25 64
B
in cm
7
1
/
4
19
5
1
/
4
13
19
3
/
4
19
3
/
4
50
50
C
in
cm
6
1
/
4
16
4
1
/
4
11
11
1
/
4
29
14
3
/
4
37
D
in
cm
E
in cm
F
in cm
13
1
/
2
34
18
1
/
2
47
G
in cm
14 36
19
1
/
4
49
J
in cm
15
38
16
1
/
2
21
3
/
4
18
3
/
4
18
3
/
4
17
42
48
48
K
M
in
in
cm
cm
43
KW199
20
1
/
2
20
1
/
4
52
52
5
1
/
4
13
19
48
3
1
/
4
8
17
3
/
4
45
7
1
/
2
19
14
1
/
4
36 19
1
/
2
49
15
1
/
4
11
3
/
4
39
30
KW500
30
1
/
4
77
5
1
/
4
13
19
3
/
4
50
4
1
/
4
11
15
1
/
4
38
20
51
20
1
/
2
52
19
48
18
3
/
4
26
48
66
55
KW600
KW750
35
1
/
2
90
513
615
19
1
/
2
19
1
/
2
50
50
4
1
/
4
11
5
1
/
4
13
15
38
19 48
20
51
40
1
/
2
103
3
8
3
1
/
4
8
19
48
19
30
3
/
4
18
3
/
4
18
3
/
4
26
48
48
48
66
29
3
/
4
76
KW850
39
3
/
4
101
6
15
19
1
/
2
50
5
1
/
4
13
19 48
44
3
/
4
114
3
1
/
2
9
19
48
18
3
/
4
35
48
26
3
/
4
31
1
/
2
68
80
L
in
cm
26
3
/
4
68
37
3
/
4
96
37
3
/
4
51
96
130
55
1
/
4
140
89
78
*
Inches - Bold
C
entimeters - Regular
Dimensional Data
Clearance and Electrical Data
Appliance
Surface
Suggested Service
Access Clearance
Left Side 1 [2.5]
inches [cm]
Models Volts Phase Amps
Right Side 12 [31]
KW 199-850 120 Single 2* Max 7.4A FLA
*Minimum 15A circuit required
4
Top 24 [61]
Back 6 [15]
Closet, Front 6 [15]
Alcove, Front 24 [61]
Vent N/A
Certified by CSA for zero clearance to combustible materials on all sides
Pump Connections
Ratings