TriangleTube GPX Series, GPX 12010, GPX 1611, GPX 2011, GPX 2413 Installation, Operation & Repair Parts Information

...
Page 1
M
OWNER’S
MANUAL
Read and save these
instructions
Installation Operation Repair parts
FOR MODELS: GPX 1210 GPX 1611 GPX 2011 GPX 2413 GPX 3013
OWNER'S RECORD
Please complete for future reference. Model #
Purchased from
_______________________
________________________________
_______________________________
Serial #
________
TRIANGLE ENGINEERING
OF ARKANSAS, INC.
E-mail: mail@trianglefans.com • Website: www.trianglefans.com
T
1101 North Redmond Road Jacksonville, Arkansas 72076 (501) 982-7558 Fax (501) 982-5691 • 1-800-255-9014
October 2016
Page 2
IMPORTANT: READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING
TO INSTALL, OPERATE OR SERVICE THIS FAN.
FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
Proper installation is required to achieve maximum efficiency. It is nec­essary to provide adequate ventilation to meet minimum intake air require­ments. This prevents pressure buildup, which will reduce the fan's efficiency. Inadequate intake air can also lead to premature motor failure.
CAUTION - SAFETY RULES
WARNING: TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK OR INJURY,
OBSERVE THE FOLLOWING:
• Use this unit only in the manner intended by the manufacturer. If you have questions, please contact manu­facturer.
• Before servicing or cleaning unit, switch power off at service panel and tag service panel to prevent power from being switched on accidentally.
• Installation and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
• Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) of fuel­burning equipment to prevent back­drafting. Follow the heating equipment manufacturer's guidelines, along with safety standards such as those pub­lished by the National Fire Protection Agency (NFPA), the American Society for Heating, Refrigeration & Air Conditioning Engineers (ASHRAE), and your local code authorities.
• CAUTION Check for hidden electrical wiring or utility lines before cutting or drilling into a wall or ceiling.
• CAUTION For general ventilating only. DO NOT use to exhaust hazardous or explosive materials.
• Your GPX fan will operate only on 120 volt AC, 60Hz (cycle) current.
• A permanent, THREE-WIRE (ground-
ed) wiring must be used. DO NOT USE AN EXTENSION CORD.
• To avoid risk of fire, electrical shock and other injuries, switch power off at service panel and tag prior to the installation.
• Do not operate fan in areas where gas or oil-fired equipment is in operation.
• Wear safety goggles when drilling, hammering, or cutting materials.
OPERATING YOUR FAN
IMPORTANT Do not operate your fan without first providing adequate ven­tilation (such as a door or window) to provide the proper inlet airflow.
WARNING BEFORE PROCEEDING WITH THE INSTALLATION, SWITCH POWER OFF AT SERVICE PANEL. The fan requires a 120-volt AC power source with at least 5-amp capacity (10-amp for 24" and 30" GPX). All electrical work must be done in accordance with local building codes, using approved mate­rial. Follow the wiring diagram shown on next page.
ITEMS REQUIRED FOR INSTALLATION
• Screwdriver • Straight edge
• Safety goggles • Pencil
• Measuring tape
• Electric drill
• Power saw or hand saw
3/4
• (12) wood screws 1/4" x
" lg.
GPX FANS ARE EASY TO INSTALL:
1. Simply cut a square opening in the wall. (See chart below).
2. Slide the fan into the opening from outside the structure. Using (12)
3
x
/4" screws, attach flange to your
1
/4"
structure.
3. Connect the motor to a 120-volt, 60-Hz single-phase power source.
Model Wall Hole Size
12 17 3/8" square
3
16 21 20 25 24 29 30 35
/8" square
3
/8" square
3
/8" square
3
/8" square
Page 3
M
otor
GPX
Fan Motor
Green Ground Screw
Green
White White
BlackBlack
120V, 60Hz Single Phase Power Supply
Use wire nuts suitable for wire size. (2) required
Screen Guard
WIRING DIAGRAM
REPAIR PARTS
Housing
Blade Assembly
When ordering repair parts, always give the following information:
1. Model Number
2. Serial Number
3. Part Description
Shutter Assembly
HOUSING DIMENSIONS
A B C D Weight Model
GPX 1210 183⁄4" 171⁄8" 6" 131⁄4" 35
GPX
GPX
GPX
1611 22
2011 26
2413 30
GPX 3013 36
Square Square LBS.
3
⁄4" 211⁄8" 6" 13" 43
3
⁄4" 251⁄8" 6" 13" 55
3
⁄4" 291⁄8" 6" 141⁄4" 66
3
⁄4" 351⁄8" 6" 13" 70
ELECTRICAL SHOCK DO NOT USE THIS FAN WITH
ANY SOLID STATE FAN SPEED CONTROL DEVICE.
WARNING: TO REDUCE THE RISK OF FIRE OR
Page 4
TROUBLESHOOTING
Symptom Possible Cause Corrective Action
Defective Motor Repair or replace motor
Fan does not operate
No power
Inspect power cord for damage. Check fuse or circuit breaker
Insu cient airfl ow
Intake Guard is excessively dirty
Shutter is blocked or not operating
Clean guards.
Check shutter for proper operation
Insu cient airfl ow Open window or door.
Squealing, Slapping or
Defective motor bearings Replace motor
Whining noises while operating
NOTE: Turning fan on and off in rapid succession will cause motor to over heat. If this occurs allow motor to cool
Damaged Blade Replace fan blade
twenty minutes before resuming operation.
MOTOR REPLACEMENT DURING WARRANTY PERIOD.
If the motor on your General Exhaust Fan should fail during the first year of operation, simply remove the LABEL ONLY from the motor and mail to Triangle Engineering, via certified or registered mail. Once the label is received, and if the motor is still under warranty, we will ship a new motor, UPS PREPAID.
DO NOT RETURN MOTOR.
LIMITED ONE YEAR WARRANTY
Triangle Engineering of Arkansas, Inc. (Manufacturer) warrants, from the date of purchase, to the origi­nal purchaser only, that the product manufactured by Manufacturer is free from defects in material and workmanship for a period of ONE (1) YEAR. Motors, capacitors, v-belts and switches are excluded from this warranty, but shall have a limited one year warranty from date of purchase to the original purchaser.
If a failure of the product occurs, contact the Manufacturer at: 1-800-255-9014 and give the model number of the product, the purchase date, and a description of the problem to the customer service agent.
Once the problem is diagnosed, and proof of purchase date is verified, Manufacturer will have the option of shipping the necessary repair part(s) to the Customer, freight prepaid or having the product returned to Manufacturer for repair or replacement. If the product is returned to the Manufacturer, Customer is responsible for prepayment of all inbound freight charges. Upon repair or replacement, which shall be at the discretion of Manufacturer, the Manufacturer will prepay all outbound freight charges for the return of the product to the customer. However, if Manufacturer finds product to be in operating condition and no problems are diagnosed, product will be returned to customer freight collect.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.
Except as provided by this express warranty, the goods are sold “as is” without any implied warran­ties.
This limited warranty does not cover labor to replace warrantied parts or motors, nor does it cover failure of the installer to provide adequate ventilation to meet minimum exhaust requirements, damage resulting from accident, misuse or abuse, lack of proper maintenance, improper installation, affixing of any parts or attachments not authorized by Manufacturer, or loss of parts.
In no event shall Manufacturer be liable for any special, incidental, or consequential damages; which may result from any defect in material or workmanship.
It is expressly understood that Buyer’s sole and exclusive remedy shall be repair or replacement of defec­tive parts, and that Triangle Engineering shall not be liable for injury to persons or property. Should the goods prove so defective, however, as to preclude the remedying of warranted defects by repair or replacement, the Buyer’s sole and exclusive remedy shall then be a refund of the purchase price.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Specifications subject to change without notice
Loading...