Triangle Engineering of Arkansas GPX 3013 User Manual

TM
OWNER’S
MANUAL
Read and save
for future reference
Installation Operation Repair parts
FOR MODELS:
GPX 1210
GPX 1611
GPX 2011
GPX 2413
GPX 3013
OWNER'S RECORD
Model #
_______________________
Date Purchased
______________________________________
_____________________________________
Triangle engineering
of arkansas, inc.
E-mail: mail@trianglefans.com • Website: www.trianglefans.com
1101 North Redmond Road Jacksonville, Arkansas 72076 (501) 982-7558 Fax (501) 982-5691 1-800-255-9014
Please complete for future reference.
Serial #
______________
IMPORTANT: READ INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS FAN.
FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
Proper installation is required to achieve maximum efficiency. It is necessary to pro­vide adequate ventilation to meet minimum intake air requirements. This prevents pres­sure buildup, which will reduce the fan's efficiency. Inadequate intake air can also lead to premature motor failure.
CAUTION - SAFETY RULES
WARNING: TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK OR INJURY,
OBSERVE THE FOLLOWING:
• Use this unit only in the manner intended
by the manufacturer. If you have ques­tions, please contact manufacturer.
• Before servicing or cleaning unit, switch
power off at service panel and tag ser­vice panel to prevent power from being switched on accidentally.
• Installation and electrical wiring must be
done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
• Sufficient air is needed for proper combus­tion and exhausting of gasses through the flue (chimney) of fuel-burning equipment to prevent backdrafting. Follow the heat­ing equipment manufacturer's guidelines, along with safety standards such as those published by the National Fire Protection Agency (NFPA), the American Society for Heating, Refrigeration & Air Conditioning Engineers (ASHRAE), and your local code authorities.
CAUTION Check for hidden electrical wir- ing or utility lines before cutting or drilling into a wall or ceiling.
CAUTION For general ventilating only. DO NOT use to exhaust hazardous or explo­sive materials.
• Your GPX fan will operate only on 120 volt
AC, 60Hz (cycle) current.
• A permanent, THREE-WIRE (grounded)
wiring must be used. DO NOT USE AN EXTENSION CORD.
• To avoid risk of fire, electrical shock and
other injuries, switch power off at service panel and tag prior to the installation.
• Do not operate fan in areas where gas or
oil-fired equipment is in operation.
• Wear safety goggles when drilling, ham­mering, or cutting materials.
OPERATING YOUR FAN
IMPORTANT Do not operate your fan without
first providing adequate ventilation (such as a door or window) to provide the proper inlet airflow.
WARNING BEFORE PROCEEDING WITH THE INSTALLATION, SWITCH POWER OFF AT SERVICE PANEL. The fan requires a 120­volt AC power source with at least 5-amp capacity (10-amp for 24" and 30" GPX). All electrical work must be done in accordance with local building codes, using approved material. Follow the wiring diagram shown on next page.
ITEMS REQUIRED FOR INSTALLATION
• Screwdriver • Straight edge
• Safety goggles • Pencil
• Measuring tape • Electric drill
• Power saw or hand saw
• (12) wood screws
1
/4" x 3/4" lg.
GPX FANS ARE EASY TO INSTALL:
1. Simply cut a square opening in the wall. (See chart below).
2. Slide the fan into the opening from out­side the structure. Using (12)
1
/4" x 3/4"
screws, attach flange to your structure.
3. Connect the motor to a 120-volt, 60-Hz single-phase power source.
Model Wall Hole Size
12 17 3/8" square 16 21 20 25 24 29 30 35
3
/8" square
3
/8" square
3
/8" square
3
/8" square
GPX
Fan Motor
Green Ground Screw
Motor
Screen Guard
Housing
When ordering repair parts, always
give the following information:
1. Model Number
2. Serial Number
3. Part Description
Use wire nuts suitable for wire size. (2) required
White White
Green
Blade Assembly
Shutter Assembly
WIRING DIAGRAM
BlackBlack
120V, 60Hz Single Phase Power Supply
REPAIR PARTS
HOUSING DIMENSIONS
A B C D Weight Model
GPX 1210 183⁄4" 171⁄8" 6" 131⁄4" 35
GPX
GPX
GPX
1611 22
2011 26
2413 30
GPX 3013 36
Square Square LBS.
3
⁄4" 211⁄8" 6" 13" 43
3
⁄4" 251⁄8" 6" 13" 55
3
⁄4" 291⁄8" 6" 141⁄4" 66
3
⁄4" 351⁄8" 6" 13" 70
TROUBLESHOOTING
SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION
Fan does not operate 1. Defective motor 1. Repair or replace motor
2. No power 2. Inspect power cord for damage
Check fuse or circuit breaker
Insufficient air flow 1. Intake guard is excessively dirty 1. Clean Guards
2. Shutter blocked or not operating 2. Check shutter for proper operation
3. Insufficient air flow 3. Open window or door
Squealing, slapping or 1. Defective motor bearings 1. Replace motor whining noises while operating
NOTE: Turning fan on and off in rapid succession will cause motor to over heat.
If this occurs allow motor to cool twenty minutes before resuming operation.
2. Damaged blade
2. Replace fan blade
MOTOR REPLACEMENT DURING WARRANTY PERIOD.
If the motor on your General Exhaust Fan should fail during the first year of operation, simply remove the LABEL ONLY from the motor and mail to Triangle Engineering, via certified or registered mail. Once the label is received, and if the motor is still under warranty, we will ship a new motor, UPS PREPAID.
DO NOT RETURN MOTOR.
LIMITED THREE YEAR WARRANTY
Triangle Engineering of Arkansas, Inc. (Manufacturer) warrants, from the date of purchase, to the original purchaser only, that the product manufactured by Manufacturer is free from defects in material and workmanship for a period of THREE (3) YEARS. Motors, capacitors, v-belts and switches are excluded from this warranty, but shall have a limited one year warranty from date of purchase to the original purchaser.
If a failure of the product occurs, contact the Manufacturer at: 1-800-255-9014 and give the model number of the product, the purchase date, and a description of the problem to the customer service agent.
Once the problem is diagnosed, and proof of purchase date is verified, Manufacturer will have the option of shipping the necessary repair part(s) to the Customer, freight prepaid or having the product returned to Manufacturer for repair or replacement. If the product is returned to the Manufacturer, Customer is responsible for prepayment of all inbound freight charges. Upon repair or replacement, which shall be at the discretion of Manufacturer, the Manufacturer will prepay all outbound freight charges for the return of the product to the customer. However, if Manufacturer finds product to be in operating condition and no problems are diagnosed, product will be returned to customer freight collect.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.
Except as provided by this express warranty, the goods are sold “as is” without any implied warranties.
This limited warranty does not cover labor to replace warrantied parts or motors, nor does it cover failure of the installer to provide adequate ventilation to meet minimum exhaust require­ments, damage resulting from accident, misuse or abuse, lack of proper maintenance, improper installation, affixing of any parts or attachments not authorized by Manufacturer, or loss of parts.
In no event shall Manufacturer be liable for any special, incidental, or consequential damages; which may result from any defect in material or workmanship.
It is expressly understood that Buyer’s sole and exclusive remedy shall be repair or replacement of defective parts, and that Triangle Engineering shall not be liable for injury to persons or property. Should the goods prove so defective, however, as to preclude the remedying of warranted defects by repair or replacement, the Buyer’s sole and exclusive remedy shall then be a refund of the purchase price.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Specifications subject to change without notice. FEB 2014