2. USERS INSTRUCTIONS
The Trianco Aztec boiler has been designed and
constructed to give years of trouble free service and
these instructions are provided to assist you in obtaining
the best performance with the least trouble and cost.
The boiler is fully automatic in operation and requires
little attention other than the setting of the thermostat
and any external system controls such as a room
thermostat and time switch.
IMPORTANT
DO NOT COVER OR BOX IN YOUR BOILER, ALLOW AIR
TO CIRCULATE FREELY AROUND THE APPLIANCE
WARNING: DO NOT ATTEMPT TO SWITCH ON THE
BOILER IF THERE IS ANY POSSIBILTY THAT THE WATER
HEAT EXCHANGER IS FROZEN
Before firing the boiler, ensure the system is full of
water and any valves fitted to system are open.
Check that the time switch/programmer (if fitted) is
ON and the room thermostat is calling for heat.
Switch on the electrical supply to the boiler and
after a few seconds the boiler’s green and amber
light should illuminate.
Set the boiler thermostat to the required
temperature using the control buttons.
Set the time switch/programmer (if fitted) to the
times and programmers required.
The boiler will now operate automatically, cutting
in and out according to heat demand.
TO TURN OFF THE BOILER
Switch off the boiler at the time
switch/programmer (if fitted).
If the boiler is to be switched off for any length of
time it is recommended that the mains supply to
the boiler is switched OFF.
BOILER CONTROL THERMOSTAT
The boiler control thermostat enables you to select the
temperature of the water leaving the boiler. It is
calibrated between 35°C and 75°C.
Using a small screwdriver set the temperature by
turning the knob to the required setting or when the
case is fitted use the buttons to switch between low and
high (35°C and 75°C in 5 degree increments).
BOILER INDICATOR LIGHT
There are three LED indicator lights on the boiler fascia
panel these are:
LED 1 – GREEN – Power on to the boiler
LED 2 – AMBER – Illuminated- in run mode
Flashing – Temperature satisfied
LED 3 – RED – Boiler fault
LED 4-12 – RED – Temperature lights
If the red LED light flashes, this means a fault has
occurred. This would result in the boiler continuing to
operate at a reduced output.
If the red LED is permanently on, this indicates a fault
has occurred. (See simple fault finding chart on page 8).
ROOM THERMOSTAT
The room thermostat should not be positioned near a
source of heat such as a radiator or exposed to the sun
as this will cause the central heating to switch off before
the room is up to temperature. Follow the
manufacturer’s instructions for best siting position for
the thermostat.
FROST PROTECTION
If the boiler and central heating is shut down for many
hours during very cold weather, the water may be in
danger of freezing. The boiler incorporates a frost
thermostat.
If the system is shut down for a long period during very
cold weather, it is advisable to completely drain the
system. However, frequent draining should be avoided,
especially in hard water areas, as this could lead to
scaling of the boiler waterways.
WARNING: DO NOT SWITCH ON THIS APPLIANCE IF
THERE IS ANY POSSIBILITY THAT THE WATER HEAT
EXCHANGER IS FROZEN.
BOILER PUMP OVERRUN
The pump will overrun for a short period of time after
boiler turns off.
TIME SWITCH/PROGRAMMER
When choosing the operating times for your boiler, it is
useful to remember that central heating usually takes
between half an hour to an hour before it becomes
effective.
It is suggested that the time switch/programmer is set to
bring on the heating about an hour after boiler
shutdown. The timer can therefore be switched off
earlier as an economy measure.
Cleaning Casings
Use hot soapy water applied with a damp dry cloth for
the enamel, then dry with a soft dry cloth.
Simple Maintenance
Ensure that the natural ventilation around the boiler is
not obstructed. If fitted in a compartment ensure all
ventilation grilles are clear.