SERVICING
To ensure reliable operation of your Aztec electric system
boiler, it is recommended that you have your boiler
serviced once a year.
The person(s) who services or carries out any remedial
work, i.e. electrical fault finding must have suitable
engineering qualifications.
Isolate mains supply before out any service work.
Check all electrical connections on PCB and electric
elements to ensure they are secure and clean.
Check electrical insulation on wiring.
Ensure all air grilles are clean and free from obstructions.
Inspect seals around elements and also, the heat
exchanger’s top and bottom flanges.
PARTS REPLACEMENT
Casing Removal
Isolate electrical supply to the boiler.
Remove 4 fixing screws securing front case in position.
Disconnect temperature button cables from the pcb.
This will allow the front casing to be removed.
IMPORTANT: All electrical connections should be
checked. Loose connections can cause problems.
The boiler is fitted with a manual reset high limit
thermostat. Before replacing any part, ensure that
thermostat does not require resetting.
PCB ASSEMBLY REPLACEMENT
Note: The PCB is supplied with the element jumper fitted
suitable for 11kW and 12kW boilers. When fitted to a 6kW
or 9kW boiler, the element jumper must be removed.
Ensure electrical supply to the boiler is isolated.
Remove the 4 fixing screws and washers (2 at top and 2 at
bottom) securing the front casing. Disconnect the
temperature button cables from the pcb and remove the
front casing.
Disconnect the pump and call plug, the thermistor
plug, the fan (where fitted) and high limit thermostat plug.
Disconnect all element cables apart from the rear
element. N.B. Take note of wiring arrangement before
disconnecting.
Now remove the grey pipe insulation, it is now possible to
disconnect the remaining element.
With all elements disconnected, again taking note of
wiring arrangement, carefully disconnect and remove the
element cables from the PCB. Important: Care must be
taken.
Disconnect the remaining red and black power cables from
the PCB.
For ease of access disconnect from the main terminal
block both the red and black cables and also the power
input cables, leaving the earth cable connected.
Free both the pump and call terminal blocks by removing
the terminal block fixing screws.
Finally remove the 4 fixing screws holding the pcb
mounting bracket in position and remove the PCB from the
unit.
Re-fit in reverse order on reassembly always refer to
wiring diagram.
HIGH LIMIT THERMOSTAT REPLACEMENT
Ensure electrical supply is isolated to boiler
The high limit thermostat can be found fixed to top side
face of boiler.
Remove 2 terminal connectors from high limit thermostat.
Remove 4 clamping nuts and clamp plate and remove high
limit thermostat.
Important when replacing thermostat ensures a heat sink
compound is used between back of thermostat and face of
boiler. (See diagram for positioning).
Inspect retaining straps and replace where necessary.
19