Bathroom layout
Recommended room size 2400 x 3000 mm, or larger.
Plumbing rough - in
Pipe, hoses and ttings, to and from bath connections
including backow preventors (check valves), shut- off valves
and lters, to be supplied and installed by others and to
comply with local building and plumbing regulations.
To eliminate pipe debris it is essential that supply pipes are
thoroughly ushed before connection of the bathtub.
The bathtub drainage shall be connected to oor or wall
drainage. To level the legs adjust the feet.
The TR installation set art no. 05193010 and 05193020
includes: check valves, valves with strainers and exible
hoses of 50 cm. Avoid any kinks on the hose curve when
bending.
Bathtub with autoll: Set the shower ow rate by adjusting
the ball-valve inside the panel located on the shower piping.
Installation Instructions
Weight lled 500 kg/1102 Ibs
Weight empty 250 kg/551 Ibs
Water volume 250 liters
Water pressure
2 - 6 bar. Inlet dynamic pressures
nominally balanced to within 10 % of each
other during ow
Flow rate 6 - 120 l/min
Hot water
temperature
65 C. Differential of approx. 50 degrees
between hot and cold water inlet
temperatures.
Drainage 100 l/min
Electrical rough - in
Standard electrical requirements: 230 V, 50 Hz, 10 Amps.
Permanent connection installed by others.
Note: All electrical conduit, tting and wire to bath supplied
and installed by your professional electrician in accordance
with local or applicable electric code as a minimum
requirement. Main switch with signal lamp, main fuse and
earth circuit breaker are not included and must be supplied by
others.
The SKF actuators are specied for 230/120 V AC +- 10 %.
If end user is using a power source which generates peeks
outside those norms, then they should use a line lter
(capacitor + choke) to regulate it.
Warning: Polarity and grounding must be correct.
Improper connection may result in injury.