TR 900
Height Adjustable Bathtub
Hygiene Equipment Designed for People
TR reserves the right to make design changes and/or improvements without notice.
Registered at Medical Products Agency, Sweden, as a MD Class 1 product, MDD 93/42EEC.
Operating Manual
Always study this manual carefully before you attempt to operate your bathing system.
This bath system is intended for professional use only where the patient will be under supervision of trained personnel.
Operating instructions and recommended maintenance procedures are explained in the following pages.
If you have any questions regarding the operation or
maintenance of your bathing system and cannot nd the
answer in this manual, please contact us.
The system is designed for years of trouble free operation, with proper use and maintenance.
Bathtub and shower water must be run at least every three days.
Serial Number:
2017-2
Head Ofce
TR Equipment AB, Sweden Phone: +46 140 38 50 60 info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900 TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386 TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment Designed for People
2
Introduction 3
Product Description, Intended Use and Technical Specications 4
Safety Instructions 6
Features and Controls for TR 900 ,-C, -CW 8
Installation Instructions 9
User Instructions 15
Basic Operating Procedures for the TR 900 Bathtub 15
Cleaning System Operation 17
Whirlpool System Operation 19
Whirlpool System Cleaning 20
LED Color Light System 22
Autoll Controls 23
Patient Handling for the TR 900 Bathtubs 24
Preparing Tub for use 24
Ambulatory Patient Transfer 25
Patient Transfer into tub with TR 9650 Chair Lift 26
Recumbent Patient Transfer, TR 9650 Stretcher Lift 27
System Components 28
Routine Maintenance 29
Labels 30
Maintenance Record 31
Training Record 31
Table of Contents
Head Ofce
TR Equipment AB, Sweden Phone: +46 140 38 50 60 info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900 TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386 TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment Designed for People
3
Introduction
Dear Customer,
Thank you for choosing one of our quality products. We hope you enjoy the TR 900 height adjustable bathtub.
This manual shall, in conjunction with staff training, ensure that the operator/user is always using and/or operating the TR 900 correctly.
TR requires that each user has read and understands the entire operating manual and that they can apply the instructions
as specied. This applies to anyone who was not present at the in-service.
This instruction manual should generally be kept easily accessible for every user. Copying the whole of the manual is encouraged since its sole purpose is to improve the standard of training and safety.
Please order another copy from us if the instruction manual is lost or unusable or if it has become illegible over time.
If you require further information or have any questions please do not hesitate to contact TR or ask one of our
qualied partners.
Please make sure you have read, understood, and applied the information on the following pages.
Head Ofce
TR Equipment AB, Sweden Phone: +46 140 38 50 60 info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900 TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386 TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment Designed for People
4
Product Description Version Art no
TR 900 TR 900 Hi Lo bathtub 05192150
UK-TMV3 05192151
Germany 05192152
TR 900C TR 900 Hi Lo bathtub with a built-in Cleaning system with safety
valve, yellow hose and cleaning shower handle.
05192160
UK-TMV3 05192161
Germany 05192162
TR 900CW TR 900 Hi Lo bathtub with a built-in Cleaning system with safety
valve, yellow hose and cleaning shower handle and a Whirlpool system with air control.
05192170
UK-TMV3 05192171
Germany 05192173
Product Description Version Art no
TR 900A TR 900 Hi Lo bathtub 05192155
Germany 05192156
TR 900CA TR 900 Autoll bathtub with a built-in Cleaning system with safety
valve, yellow hose and cleaning shower handle.
05192165
Germany 05192166
TR 900CWA TR 900 Autoll bathtub with a built-in Cleaning system with safety
valve, yellow hose and cleaning shower handle and a Whirlpool system with air control.
05192175
Germany 05192176
Intended Use
Device Models: TR 900 TR 900C TR 900CW TR 900A TR 900CA TR 900CWA
The device “TR 900” is intended for bathing and showering of patients.
The patient is typically a person who is unable to take care of their own
personal hygiene.
The device is not intended to be used with patients that exceeds
a weight of 150 kg/330 Ibs.
The device is not intended to come in contact with for example wound or injured skin.
The user is any adult person who is capable of reading and understanding the
operating manual and is qualied to care for dependent persons/patients.
Before using the device, the user must read and understand the operating manual.
The device is intended to be used indoors in all types of care facilities and private homes,
including hygiene areas.
This manual includes instructions for the operation of the following equipment:
Product Descriptions, Intended Use and Technical Specications
Head Ofce
TR Equipment AB, Sweden Phone: +46 140 38 50 60 info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900 TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386 TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment Designed for People
5
Outside length 2 325 mm/92”
Outside width 830 mm/33”
Inside width (head end) 700 mm/28”
Inside width (foot end) 630 mm/25”
Inside width (tub body) 472 mm/19”
Access height 610 mm/24”
Clearance between the
oor and the botton of
the tub
175 mm/7”
Max. total load
Individuals weighing no more than 150 kg/330 Ibs with max
Height settings 610 - 940 mm/24” - 37”
Power supply 230 V, 50 Hz/110 V, 60 Hz
Bathtub body material GRP
Lift stroke 330 mm
Lift speed 13 mm/s
Lifting power actuator 7000 N
Power supply 110 V/60 Hz alt. 230 V/50 Hz
Control voltage 24 V
Overall weight (empty) 265 kg/584 Ibs
Bathtub faucet
See thermostat mixer operating manual
Technical Specications
“TR900” is a height adjustable bathtub. The bathtub can be raised and lowered within the operating height range. The height adjustable bathtub TR 900 is designed for bathrooms in nursing homes, clinics and hospitals and consists of:
1. The tub and panel are made of glass ber. The bre panel
covering actuator, control units and all internal sanitary installations.
2. The three-step adjustable foot support is pushed into the slots to accommodate the different lengths of patients and to avoid them from sliding and provide secure support for their feet. The foot support can be removed, for example when using a stretcher.
3. Overow protection and pop-up drain which opens and closes the drainage system by rotating the overow valve.
4. The thermostat mixer is designed to regulate the water
temperature to the bathtub lling spout and to the
handheld shower. See separate thermostat mixer operation manual for further information.
5. The shower handle with shower hose is to be used to shower the patient and to rinse equipment after cleaning.
6. One linear actuator for height adjustment within the operating height range.
7. Control buttons and thermometer are located on the panel.
8. Two legs including adjustable feet if the oor should be
uneven.
Head Ofce
TR Equipment AB, Sweden Phone: +46 140 38 50 60 info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900 TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386 TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment Designed for People
6
Safety Instructions
This HiLo bathtub may only be operated by qualied and
trained staff.
Please make sure that:
All safety and operating instructions are read and
understood and that they are adhered to and applied when using the bath.
New colleagues must be trained by qualied and
experienced staff.
The bathtub may only be installed and connected
according to our assembly and installation instructions by
specialists such as a certied electrical installation
company. Local guidelines and regulations as well as installation rules for water and power connections must be adhered to.
Even if you have chosen our company to install the
bathtub, the cold and hot water supply and the electrical wiring is the buyer’s responsibility.
Electrical wiring must be carried out on site by a qualied
electrician.
The bathtub may only be connected to the power supply
via a cord that is connected to a GFCI (ground fault circuit interrupter) including an easily accessible switch near the bathtub.
Maintenance work must be carried out by specialist rms
or trained staff.
Repairs can only be carried out after consulting the
supplier.
Repairs shall only be carried out by specialist rms using
original spare parts.
Every time, before the bathtub is used, please make sure that there are no visible damages/defects such as:
Cracks in the tub body/side covers
Damages to the main cord
Ensure that the bathtub is lowered/raised evenly
Make sure the tub stands stable
There are no defects and the thermostat and option
buttons are all working properly
Important: The manufacturer’s warranty and liability
expire automatically if modications or repairs are carried
out or if components are exchanged or opened without the manufacturers consent.
Head Ofce
TR Equipment AB, Sweden Phone: +46 140 38 50 60 info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900 TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386 TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment Designed for People
7
Safety Instructions
If you have a question regarding the operation or maintenance
of your TR 900 Bathing System and cannot nd the answer in
this manual, please contact us.
When using the TR 9650 the patient must be seated
comfortably on the chair and/or stretcher, with safety belts securely attached. Safety belts must be maintained in good condition.
Raise Stretcher/Chair to ensure clearance of all body
parts over the tub. This is to avoid the patient from being pinched between the tub rim and the Chair/Stretcher frame during transfer.
Before raising or lowering the tub, make sure that the
patients hands rmly grasp the stabilizing bar or that the
patients arms are crossed over his/her body. This is to
avoid pinched arms or ngers between the
Stretcher/Chair frame and the tub rim.
Warning: Always disconnect electric power before attempting any service or repair.
Wipe beneath Stretcher/Chair to prevent water dripping
on the oor.
Always physically check water temperature before and
during bathing/ showering to ensure that the thermoscopic mixer is functioning. The thermostatic mixing valves are fully performance tested individually and the maximum temperature is factory preset at approximately 43°C under ideal installation conditions at the factory.
Make sure that all parts that come in contact with the
patient are intact and without sharp edges.
Check that hoses, tub controls, connections, mixer and
thermometer are free from damage.
Warning: Never leave a patient unattended.
Head Ofce
TR Equipment AB, Sweden Phone: +46 140 38 50 60 info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900 TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386 TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment Designed for People
8
Features and Controls for TR 900 ,-C, -CW
Bathtub height adjustment and lling
1 Bathtub up/down control buttons
2 Thermostatic mixer
3 Thermometer
4 On-off valve for bathtub lling
5 Bathtub lling spout
6
Bathtub overow drain
Drain-close/open
8 Adjustable footrest, two positions
Patient shower
2 Thermostatic mixer
3 Thermometer
9 On-off valve for patient shower
10 Patient shower hose
11 Patient shower handle
12 Handle bracket
Whirlpool system (W)
20 Motor control on/off for whirlpool
21 Adjustable whirlpool jet
22 Air control valve
23 Whirlpool inlet safety screen
8
Cleaning system (C)
13 Shut-off safety valve
14 Spray equipment hose
15 Spray handle
16 Spray handle bracket
17
Mixing setting screw (inside the panel)
18 Detergent lling lid
19
Yellow cleaning adapter, for Whirlpool
Head Ofce
TR Equipment AB, Sweden Phone: +46 140 38 50 60 info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900 TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386 TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment Designed for People
9
Bathroom layout
Recommended room size 2400 x 3000 mm, or larger.
Plumbing rough - in
Pipe, hoses and ttings, to and from bath connections including backow preventors (check valves), shut- off valves and lters, to be supplied and installed by others and to
comply with local building and plumbing regulations. To eliminate pipe debris it is essential that supply pipes are
thoroughly ushed before connection of the bathtub. The bathtub drainage shall be connected to oor or wall
drainage. To level the legs adjust the feet.
The TR installation set art no. 05193010 and 05193020
includes: check valves, valves with strainers and exible
hoses of 50 cm. Avoid any kinks on the hose curve when bending.
Bathtub with autoll: Set the shower ow rate by adjusting
the ball-valve inside the panel located on the shower piping.
Installation Instructions
Weight lled 500 kg/1102 Ibs
Weight empty 250 kg/551 Ibs
Water volume 250 liters
Water pressure
2 - 6 bar. Inlet dynamic pressures nominally balanced to within 10 % of each
other during ow
Flow rate 6 - 120 l/min
Hot water temperature
65 C. Differential of approx. 50 degrees between hot and cold water inlet temperatures.
Drainage 100 l/min
Electrical rough - in
Standard electrical requirements: 230 V, 50 Hz, 10 Amps. Permanent connection installed by others.
Note: All electrical conduit, tting and wire to bath supplied
and installed by your professional electrician in accordance with local or applicable electric code as a minimum requirement. Main switch with signal lamp, main fuse and earth circuit breaker are not included and must be supplied by others.
The SKF actuators are specied for 230/120 V AC +- 10 %.
If end user is using a power source which generates peeks
outside those norms, then they should use a line lter (capacitor + choke) to regulate it.
Warning: Polarity and grounding must be correct. Improper connection may result in injury.
Head Ofce
TR Equipment AB, Sweden Phone: +46 140 38 50 60 info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900 TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386 TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment Designed for People
10
Floor Drainage
Mount the bracket for the drainage pipe to the front of the panel. Adjust by cutting the length of the pipe.
Wall Drainage
Mount the bracket for the drainage pipe to the back of the panel.
Installation Instructions