Trend Micro TippingPoint series, TPS 8400TX, TPS 2200T, TPS 8200TX, TPS 440T Hardware Specification And Installation Manual

Page 1
Threat Protection System Hardware Specification and Installation Guide
Version 5.0.0
5900-4108 October 2017
Page 2
Legal and notice information
© Copyright 2017 Trend Micro Incorporated. All rights reserved. TippingPoint, the TippingPoint logo, and Digital Vaccine are trademarks or registered trademarks of Trend Micro Incorporated. TippingPoint Reg. U.S. Pat. & Tm. Off. All other company and/or product names may be trademarks of their respective owners.
Trend Micro Incorporated makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Trend Micro Incorporated shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced in any form or by any means, or translated into another language without the prior written consent of Trend Micro Incorporated. The information is provided “as is” without warranty of any kind and is subject to change without notice. The only warranties for Trend Micro Incorporated products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Trend Micro Incorporated shall not be liable for technical or editorial errors or omissions contained herein.
TippingPoint Threat Protection System Hardware Specification and Installation Guide
Page 3

Contents

About this guide......................................................................................................................................1
Target audience...................................................................................................................................... 1
Related documentation...........................................................................................................................1
Conventions............................................................................................................................................ 1
Product support...................................................................................................................................... 2
Overview...................................................................................................................................................3
TPS TX Series devices.......................................................................................................................... 3
TPS 2200T device..................................................................................................................................5
TPS 440T device....................................................................................................................................6
TPS TX Series product overview.......................................................................................................... 8
Device overview......................................................................................................................................8
Chassis – front panel...........................................................................................................................8
Chassis – rear panel........................................................................................................................... 9
Chassis – features............................................................................................................................. 10
Power button................................................................................................................................... 10
Fans and power supplies................................................................................................................11
External SSD................................................................................................................................... 11
Ports.................................................................................................................................................11
Chassis LEDs.................................................................................................................................. 12
Model requirements.............................................................................................................................. 13
Power requirements........................................................................................................................... 13
Cabling requirements......................................................................................................................... 13
I/O module installation..........................................................................................................................13
Before you begin................................................................................................................................14
Threat Protection System Hardware Specification and Installation Guide i
Page 4
ESD requirements..............................................................................................................................14
I/O module options.............................................................................................................................14
Module LEDs......................................................................................................................................16
I/O module replacement.................................................................................................................... 17
Supported transceivers and cables for TippingPoint I/O modules.................................................... 18
Technical specifications........................................................................................................................ 18
TPS 2200T product overview...............................................................................................................20
Device overview....................................................................................................................................20
Chassis – front panel.........................................................................................................................20
Chassis – rear panel......................................................................................................................... 21
Chassis – features............................................................................................................................. 22
Power button................................................................................................................................... 22
System status indicator................................................................................................................... 23
Alert indicator...................................................................................................................................23
Fans and power supplies................................................................................................................23
External storage card......................................................................................................................23
Ports.................................................................................................................................................23
Model requirements.............................................................................................................................. 25
Power requirements........................................................................................................................... 25
Cabling requirements......................................................................................................................... 25
Pluggable transceivers......................................................................................................................... 25
Technical specifications........................................................................................................................ 26
TPS 440T product overview.................................................................................................................28
Device overview....................................................................................................................................28
Chassis – front panel.........................................................................................................................28
Chassis – rear panel......................................................................................................................... 29
Chassis – features............................................................................................................................. 29
Power switch and power indicator.................................................................................................. 29
ii Threat Protection System Hardware Specification and Installation Guide
Page 5
System status indicator................................................................................................................... 30
Alert indicator...................................................................................................................................30
Fans and power supplies................................................................................................................30
External storage card......................................................................................................................30
Ports.................................................................................................................................................30
Model requirements.............................................................................................................................. 32
Power requirements........................................................................................................................... 32
Cabling requirements......................................................................................................................... 32
Technical specifications........................................................................................................................ 32
Install your TPS device........................................................................................................................ 34
Install the chassis................................................................................................................................. 34
Determine total rack space................................................................................................................34
Attach the device to the rack............................................................................................................ 35
Install the external storage card........................................................................................................ 35
Connect the power supply.................................................................................................................35
Add the I/O modules – TPS TX Series................................................................................................36
Attach the cables..................................................................................................................................36
Connect the console port.................................................................................................................. 37
Connect the management port.......................................................................................................... 37
Turn on the device............................................................................................................................... 37
Check the LEDs................................................................................................................................... 37
Run the setup wizard........................................................................................................................... 38
Install your license package.................................................................................................................38
Attach network connections................................................................................................................. 39
Where to go next..................................................................................................................................39
Connector and cable pinout specifications....................................................................................... 41
Threat Protection System Hardware Specification and Installation Guide iii
Page 6
RJ-45 (COM) console...........................................................................................................................41
RJ-45 Ethernet connectors...................................................................................................................42
Power supplies...................................................................................................................................... 43
AC power supply – TPS 2200T and TX Series................................................................................... 43
Connect the AC power supply...........................................................................................................44
DC power supply – TPS TX Series..................................................................................................... 44
Connect the DC power supply.......................................................................................................... 44
Fans........................................................................................................................................................ 46
Replace the fan – TPS TX Series....................................................................................................... 46
Power cord retention bracket.............................................................................................................. 48
Overview............................................................................................................................................... 48
Install the retention bracket..................................................................................................................48
Use the power cord retention bracket..................................................................................................49
Remove the bracket............................................................................................................................. 49
External user disk................................................................................................................................. 50
External SSD........................................................................................................................................ 50
External CFast storage card................................................................................................................ 50
External user disk commands..............................................................................................................51
iv Threat Protection System Hardware Specification and Installation Guide
Page 7

About this guide

Welcome to the installation and specification guidelines for your Threat Protection System (TPS) device.
This section covers the following topics:
Target audience on page 1
Related documentation on page 1
Conventions on page 1
Product support on page 2

Target audience

The intended audience includes technicians and maintenance personnel responsible for installing, configuring, and maintaining TippingPoint security systems and associated devices. Users should be familiar with the following concepts or environments:
Basic networking
Network security
Routing

Related documentation

A complete set of documentation for your product is available on the TippingPoint Threat Management Center (TMC) at https://tmc.tippingpoint.com. The documentation generally includes installation and user guides, command line interface (CLI) references, safety and compliance information, and release notes.

Conventions

This information uses the following conventions.
Typefaces
The following typographic conventions for structuring information are used.
Convention Element
Bold font
Key names
Text typed into a GUI element, such as into a box
Threat Protection System Hardware Specification and Installation Guide 1
Page 8
Convention Element
GUI elements that are clicked or selected, such as menu and list items, buttons, and check boxes. Example: Click OK to accept.
Italics font Text emphasis, important terms, variables, and publication titles
Monospace font
Monospace, italic font
Monospace, bold font
Messages
Messages are special text that is emphasized by font, format, and icons.
Warning!
Alerts you to potential danger of bodily harm or other potential harmful consequences.
File and directory names
System output
Code
Text typed at the command-line
Code variables
Command-line variables
Emphasis of file and directory names, system output, code, and text typed at the command line
Caution:
Note: Provides additional information to explain a concept or complete a task.
Important: Provides significant information or specific instructions.
Tip: Provides helpful hints and shortcuts, such as suggestions about how to perform a task more easily or
more efficiently.
Provides information to help minimize risk, for example, when a failure to follow directions could result in damage to equipment or loss of data.

Product support

Information for you to contact product support is available on the TMC at https://tmc.tippingpoint.com.
2 Threat Protection System Hardware Specification and Installation Guide
Page 9

Overview

The TippingPoint Threat Protection System (TPS) is a high-performance, enterprise-class solution that protects your network by scanning, detecting, and responding to network traffic according to the filters, action sets, and global settings maintained on each device by a client.
The TPS offers higher throughput and improved technology that is optimized for high resiliency, high availability, and network segment protection from both external and internal attacks.
You can install as many TPS security devices as you need to strategically protect your network enterprise zones. A local client on the device monitors and manages activity. Alternatively, you can manage devices by using the Security Management System (SMS) console.
Information about each TPS product is covered in the following sections:
TPS TX Series devices on page 3
TPS 2200T device on page 5
TPS 440T device on page 6
For information about the Virtual Threat Protection System (vTPS) security device, see the product documentation on the TMC at https://tmc.tippingpoint.com.

TPS TX Series devices

Figure 1. TPS 8200TX and 8400TX devices – front panel
The TPS 8200TX and 8400TX security devices provide the following hardware features.
Threat Protection System Hardware Specification and Installation Guide 3
Page 10
Table 1. TPS 8200TX and 8400TX – hardware features
Feature TX Series devices
Ports Two fixed QSFP+ special purpose (SP) ports
One RJ-45 console port
One 1 GbE copper management port
Slots
Model 8200TX – two I/O slots
Model 8400TX – four I/O slots
Power supply Two hot-swappable 750W AC power supplies
System memory 128 GB DDR4-2133 DRAM (four 16 GB DDR4-2133
SDRAM per CPU)
External storage One 32 GB SSD
Replaceable fans 7 hot-swappable fans
High Availability (HA) Yes
In addition, the device includes:
IPS inspection throughput: Up to 40 Gbps aggregate across all slots
IPS + SSL inspection throughput: Up to 2 Gbps SSL inspection across all slots
Mac-in-Mac support
Device management through the LSM or centralized management through the SMS
4 Threat Protection System Hardware Specification and Installation Guide
Page 11

TPS 2200T device

Figure 2. TPS 2200T device – front panel
The TPS 2200T device provides the following hardware features.
Table 2. TPS 2200T – hardware features
Feature 2200T device
Ports One RJ-45 console port
One 1 GbE copper management port
Copper ports 8
1 GbE SFP ports 8
10 GbE SFP+ ports 4
Power supply 2 hot-swappable 750W AC power supplies
System memory 64 GB
Threat Protection System Hardware Specification and Installation Guide 5
Page 12
Feature 2200T device
External storage One 8 GB CFast
System fans 3 fans (not replaceable)
High Availability (HA) Yes
Zero Power High Availability (ZPHA)* Built-in ZPHA for copper segments
External ZPHA port for SFP and SFP+ segments
*For information on installing and operating a ZPHA module, refer to TippingPoint ZPHA Installation Guide – Modular and Non-Modular available on the TMC at https://tmc.tippingpoint.com/.
In addition, the device includes:
Built-in intrinsic high-availability features for copper segments, guaranteeing continuity in the event of system failure
IPS inspection throughput: 1 Gbps (Base) upgradeable to 2 Gbps aggregate across all 10 segments
IPS + SSL Throughput: 500 Mbps + 500 Mbps (1 Gbps License) or 1.5 Gbps + 500 Mbps ( 2 Gbps License)
Encryption for VPN service
Device management through the LSM or centralized management through the SMS

TPS 440T device

Figure 3. TPS 440T device
The TPS 440T device provides the following hardware features.
6 Threat Protection System Hardware Specification and Installation Guide
Page 13
Table 3. TPS 440T – hardware features
Feature 440T device
Ports One RJ-45 console port
One 1 GbE copper management port
Copper ports 8
1 GbE SFP ports None
10 GbE SFP+ ports None
Power supply One 350W (built-in) power supply
System memory 16 GB
External storage One 8 GB CFast
System fans 3 external fans and 2 internal fans (not replaceable)
High Availability (HA) Yes
Zero Power High Availability (ZPHA) Built-in ZPHA on the 8 copper ports
In addition, the device includes:
Built-in intrinsic high-availability features, guaranteeing continuity in the event of system failure
IPS inspection throughput: 500 Mbps (base) upgradeable to 1 Gbps aggregate across all four segments
Encryption for VPN service
Device management through the LSM or centralized management through the SMS
Threat Protection System Hardware Specification and Installation Guide 7
Page 14

TPS TX Series product overview

This information describes the components, chassis, requirements, and installation specifics of the TPS 8200TX and 8400TX devices. The following topics are discussed:
Device overview on page 8
Model requirements on page 25
I/O module installation on page 13
Technical specifications on page 26
For information about installing the device, see Install your TPS device on page 34. Prior to installation, have the TPS CLI Reference available for configuration information.

Device overview

The 8200TX and 8400TX devices are high-range systems that are designed for network environments requiring up to 40 Gbps of inspection throughput with up to 2 Gbps available for Secure Socket Layer (SSL) inspection.

Chassis – front panel

The TPS TX Series devices include a 1U (8200TX) and a 2U (8400TX) form-factor device that are rack­mountable in a 19-inch rack (or 23-inch rack, with appropriate conversion parts available from rack accessory vendors). These appliances support throughput across multiple copper and fiber ports.
The 8200TX and 8400TX security devices provide up to 40 Gbps of inspection throughput.
The following illustration shows a front panel view of the TX Series devices:
8 Threat Protection System Hardware Specification and Installation Guide
Page 15
Figure 4. TPS 8200TX and 8400TX devices – front panel
1. I/O modules
2. SP ports
3. External storage 1.8-inch SSD (32 GB)
4. Stack Master LED
5. Stack LED
6. Bypass LED
7. System status LED
8. GbE management port
9. Power button
10. RJ-45 console port

Chassis – rear panel

The following illustration shows the rear-panel view of the TPS 8200TX and 8400TX devices.
Threat Protection System Hardware Specification and Installation Guide 9
Page 16
Figure 5. TPS TX Series devices – rear panel
1. Fan modules - fans are numbered from left to right (Fan 1 is on the left; Fan 7 is on the right)
2. Power supply modules (Power supply 1 is on the left; Power supply 2 is on the right)
3. DC grounding lug screw holes

Chassis – features

The TPS TX Series chassis features include the following elements:
Power button on page 10
Chassis LEDs on page 12
Fans and power supplies on page 11
External storage card on page 23
Ports on page 23
Power button
The power button is located on the right side of the console/management ports on the front panel. The power button light indicates the current status of the appliance.
No light — Appliance is powered off.
Green — Appliance is powered on.
10 Threat Protection System Hardware Specification and Installation Guide
Page 17
Fans and power supplies
The TPS TX Series devices include two power supplies and seven cooling fans. These components are hot­swappable. For more information about these components, see Power supplies on page 43 and Fans on page 46.
External SSD
The TPS TX Series device includes an external SSD module that is installed with your product. The SSD stores traffic logs, snapshots, and other system data. The card can be removed and inserted while the device is running; however, to do so, you must issue the appropriate unmounting, mounting, and preparation commands in the device CLI.
For more information about the procedure, refer to External user disk on page 50.
Ports
The TPS TX Series devices are equipped with network slots for standard or bypass I/O modules.
In addition, the device provides a console and management port as shown in the following figure:
Figure 6. TPS TX Series devices – management and console ports
1. 1 RJ-45 serial console port
2. 1 GbE copper management port
3. Activity LED
Threat Protection System Hardware Specification and Installation Guide 11
Page 18
4. Link LED
The management port LEDs indicate link and activity state, as described in the following table.
Table 4. TPS 8200TX and 8400TX – port LED states
LED Type Color Description
Green Link is active at 1000 Mbps.Link
Off Link is inactive, or is active at 10 Mbps or 100 Mbps.
Blinking amber Data traffic is passing.Activity
Off No traffic is passing.
Chassis LEDs
When you turn on the device, the system completes a series of component checks and then displays LED indicators to show the status of each component:
Stack Master status
Solid green: Indicates that the device is the stack master.
Off: Indicates that the device is not the stack master.
Stack status
Solid green: Indicates that the device is RTI and is inspecting network traffic.
Off: Indicates that stacking is not enabled on the device.
Bypass status
Solid red: Indicates that the device is in Intrinsic High Availability (Intrinsic HA) Layer-2 Fallback
(L2FB) mode.
Off: Indicates that the device is not in L2FB mode.
System health status
Flashing green: Indicates that the system is booting up, and is not yet ready to inspect traffic.
Solid green: Indicates that the system is healthy.
12 Threat Protection System Hardware Specification and Installation Guide
Page 19
Red: Indicates that the system is experiencing a health alert, such as a fan failure. This state resets to
solid green when you view the system log.
Management port status
Link LED: Solid green indicates that the port is linked and ready for data.
Activity LED: Flashing amber indicates that the port is passing data.
Power button status
Off: Indicates that the system is off.
Solid green: Indicates that the system is on.

Model requirements

The following topics describe specific requirements for the TPS TX Series devices.
Power requirements on page 13
Cabling requirements on page 25

Power requirements

The 8200TX and 8400TX devices require Alternating Current (AC) or Direct Current (DC) that meets the following requirements:
AC: Voltage 100V to 240V; 12 to 6A; 47 to 63 Hz
DC: Voltage -40V to -60V; 24 to 16A
The TX Series devices ship with two AC power supplies. DC power supplies are also available for the device. Consult your TippingPoint account contact for more information if you require a DC power supply.

Cabling requirements

The TPS 8200TX and 8400TX devices ship with the following cables:
Two AC power cables, one for each hot-swappable power supply
Null modem cable (USB to RJ-45) for the serial console management port shown in Figure 6 on page 11

I/O module installation

Use these instructions to set up the I/O modules supported in TippingPoint security devices.
This section includes the following topics:
Threat Protection System Hardware Specification and Installation Guide 13
Page 20
Before you begin on page 14
ESD requirements on page 14
I/O module options on page 14
Module LEDs on page 16
I/O module replacement on page 17
Supported transceivers and cables for TippingPoint I/O modules on page 18

Before you begin

Review the release notes for your product on the TippingPoint online Threat Management Center (TMC) at https://tmc.tippingpoint.com for any late-breaking changes to the installation instructions.
Read and follow all safety information listed in the TippingPoint Hardware Safety and Compliance Guide that shipped with your product.
Complete the installation of your TippingPoint security device.

ESD requirements

Damage from Electrostatic Discharge (ESD) can occur when electronic components are improperly handled. Improper handling can result in complete or intermittent system failures. Proper ESD protection is required whenever you handle equipment. The following general grounding guidelines apply:
Always use an ESD wrist strap when adding or removing components from the chassis.
Avoid touching the circuit boards or connectors on all cards and modules.
Avoid contact between the printed circuit boards and clothing. The wrist strap only protects components from ESD voltages on the body. ESD voltages on clothing can still cause damage.
Place a removed component board-side-up on an antistatic surface or in a static-shielding container that is also grounded to the same point as the IPS. If you plan to return the component to the factory, immediately place it in a static-shielding container.

I/O module options

TippingPoint devices with module slots support both standard I/O modules and bypass I/O modules. Refer to the following table for fiber and copper components.
Important: Only optical transceiver modules (including SFP, SFP+, and QSFP+) available from
TippingPoint have been validated to achieve optimal performance with TippingPoint products. Other vendor devices are not supported. Using other vendor devices could be detrimental to proper operation of the TippingPoint system.
14 Threat Protection System Hardware Specification and Installation Guide
Page 21
Bypass I/O modules are zero-power high-availability (ZPHA) modules that permit network traffic and services while bypassing the device entirely when the device loses power.
All four standard I/O modules and all five bypass I/O modules are hot-swappable on devices running TippingPoint Operating System (TOS) v3.6.0 or higher.
For more information on the I/O modules, refer to the product hardware documentation for your TippingPoint device.
Table 5. Supported I/O modules and bypass I/O modules
Standard I/O Modules Bypass I/O Modules
6-Segment Gig-T
Ports: 12 Fixed RJ-45 copper ports
Port speed: 10/100/1000 Mbps
Part number: TPNN0059
6-Segment GbE SFP
Ports: 12 SFP ports
Port speed: 1 Gbps
Part number: TPNN0068
4-Segment Gig-T Bypass Module
Ports: 8 copper ports
Port speed: 10/100/1000 Mbps
Part number: TPNN0070
2-Segment 1G Fiber SR/LR Bypass Module
Ports: 4 Multi-Mode (SR)/Single-Mode (LR) Fiber (LC type)
Port speed: 1 Gbps
Part number: TPNN0071/TPNN0072
4-Segment 10GbE SFP+ 2-Segment 10G Fiber SR/LR Bypass Module
Threat Protection System Hardware Specification and Installation Guide 15
Page 22
Standard I/O Modules Bypass I/O Modules
Ports: 4 Multi-Mode (SR)/Single-Mode (LR) Fiber (LC type)
Ports: 8 Fiber SFP+ ports
Port speed: 1/10 Gbps
Port speed: 10 Gbps
Part number: TPNN0073/TPNN0074
Part number: TPNN0060
1-Segment 40 GbE QSFP+
Ports: 2 Fiber QSFP+ ports
Port speed: 40 Gbps
Part number: TPNN0069
Important: Handle all I/O modules with care. The bypass modules contain mechanical switches that are
very sensitive to handling when not installed in the system. Network disruption can occur if handled improperly. For more information about deploying bypass modules, refer to the product hardware documentation for your TippingPoint security device.

Module LEDs

The following table describes the states of each LED on the I/O module.
Table 6. I/O module and bypass I/O module LED states
Feature LED Color Description
Fixed RJ45 copper port Link Green Link is active.
16 Threat Protection System Hardware Specification and Installation Guide
Page 23
Feature LED Color Description
Activity Blinking Amber Data traffic passing.
Optical transceiver port Link
Activity
Module health Status Green
Green
Amber
Blinking Amber
Link is active.
Data traffic passing.
The module is configured, in service, and in good health.
The module has been inserted and powered up, but is not yet
Solid Amber
Bypass Status Off
Green
recognized by the software.
The module is experiencing a fault.
Module in bypass.
Module in normal mode (not in bypass).

I/O module replacement

On a TPS TX Series device, hot swapping allows you to add, remove, or replace an I/O module without shutting down the device. When the device is turned on, you can hot swap an I/O module without interruption to the TPS device.
Note: Hot-swapping I/O modules during system initialization is not supported.
When you hot swap an I/O module, keep the following points in mind:
The module port configuration is always reset.
The module segment configuration, including link-down synchronization, Intrinsic HA, and inspection bypass, is always preserved.
When the device is turned off, cold swapping allows you to add, remove, or replace an I/O module as you would when you hot swap. However, when you cold swap an I/O module, if the replacement module type is the same, the module port configuration is preserved.
Threat Protection System Hardware Specification and Installation Guide 17
Page 24
When the device is managed by the SMS, a delay of up to 1 minute can occur before the SMS recognizes the changed I/O module.
Note: When you insert a bypass I/O module, the bypass I/O module always starts up in bypass mode. A
bypass I/O module remains in bypass mode until you remove it from bypass mode through the CLI, LSM, or SMS. Rebooting the TPS does not change the bypass mode of the bypass I/O module.

Supported transceivers and cables for TippingPoint I/O modules

Table 7. Supported transceivers for I/O modules
I/O module & part number Transceiver
part number
6-Segment GbE SFP (TPNN0068) TPNN0054
TPNN0055
TPNN0056
4-Segment 10 GbE SFP+ (TPNN0060)
TPNN0057
TPNN0058
TPNN0054
Transceiver name
TippingPoint X126 1G SFP RJ45 Transceiver
TippingPoint X126 1G SR Fiber SFP Transceiver
TippingPoint X126 1G LR Fiber SFP Transceiver
TippingPoint S136 10G SFP+ LC SR Transceiver
TippingPoint S136 10G SFP+ LC LR Transceiver
TippingPoint X126 1G SFP RJ45 Transceiver
1-Segment 40 GbE QSFP+ (TPNN0069)
TPNN0067 TippingPoint S146 40G QSFP+ SR4
850nm Transceiver

Technical specifications

The TPS TX Series devices have the following specifications.
18 Threat Protection System Hardware Specification and Installation Guide
Page 25
Table 8. TPS 8200TX and 8400TX – technical specifications
Specification Description
Dimensions (unpackaged)
Weight
Power Requirements
Service Provider operating requirements
8200TX (1U form factor) – 1.73 in x 18.54 in x 24.84 in (44 mm x 428 mm x 631mm)
8400TX (2U form factor) – 3.46in x 18.54 in x 24.84 in (88mm x 428 mm x 631 mm
8200TX – 32 lbs (14.5 kg)
8400TX – 50 lbs (22.7kg)
AC: Voltage 100 to 240; Current 12 to 6A; Frequency 47to 63 Hz
DC: Voltage -40 to -60, Current 24 to 16A, SELV
The device’s maximum power consumption is 750W.
Temperature: 32 to 104° F (0 to 40° C) — Operating
Temperature: -4 to 158° F (-20 to 70° C) — Storage
External interfaces
Altitude: No degradation up to 10,000 feet (3048m)
Humidity: 5% to 95% (non-condensing)
One 1 GbE copper management port
One RJ-45 console port
Two fixed QSFP+ special purpose (SP) ports
Network slots:
8200TX – 2 slots
8400TX – 4 slots
1 SSD slot
Threat Protection System Hardware Specification and Installation Guide 19
Page 26

TPS 2200T product overview

This information describes the components, chassis, requirements, and installation specifics of the TippingPoint 2200T device. The following topics are discussed:
Device overview on page 20
Model requirements on page 25
Pluggable transceivers on page 25
Technical specifications on page 26
For information about installing the device, see Install your TPS device on page 34. Prior to installation, have the TPS CLI Reference available for configuration information.

Device overview

The TPS 2200T device is a mid-range system that has a larger form factor than the TPS 440T device and is designed for network environments requiring up to 2 Gbps of inspection throughput with up to 500 Mbps available for Secure Socket Layer (SSL) inspection. This model provides the same high-level of security protection as the higher-capacity models.

Chassis – front panel

The TPS 2200T device is a 2U form-factor device that is rack-mountable in a 19-inch rack (or 23-inch rack, with appropriate conversion parts available from rack accessory vendors). This device supports throughput across multiple copper and fiber ports.
The following illustration shows a front panel view of the TPS 2200T device:
20 Threat Protection System Hardware Specification and Installation Guide
Page 27
Figure 7. TPS 2200T device – front panel
1. 10GbE SFP+ ports
2. 1GbE SFP ports
3. 1GbE copper ports
4. External CFast card
5. Dedicated HA port
6. ZPHA port
7. Console/Management port
8. Power button
9. Alert indicator
10. System status indicator

Chassis – rear panel

The following illustration shows the rear-panel view of the TPS 2200T device.
Threat Protection System Hardware Specification and Installation Guide 21
Page 28
Figure 8. TPS 2200T – device rear panel
1. Fans (3)
2. Power supplies (2)

Chassis – features

The TPS 2200T chassis features include the following elements:
Power button on page 22
System status indicator on page 23
Alert indicator on page 23
Fans and power supplies on page 23
External storage card on page 23
Ports on page 23
Power button
The power button is located on the right side of the console/management ports on the front panel. The power button light indicates the current status of the appliance.
No light — Appliance is powered off.
Green — Appliance is powered on.
22 Threat Protection System Hardware Specification and Installation Guide
Page 29
System status indicator
The System Status indicator is located on the right side of the front panel and indicates the current operating status of the appliance.
Flashing Green — Appliance is booting and is not yet ready to inspect traffic.
Flashing Green/Yellow — Appliance is booting and BIOS or software is updating.
Solid Green — Appliance is running in a healthy state.
Solid Yellow — Appliance is running but has a health rating below the acceptable threshold.
Alert indicator
The Alert indicator is located on the right side of the front panel and indicates the current status of the software processes and the hardware.
Solid Green — Both the hardware and the software processes are running normally.
Solid Yellow — System is booting. If the solid yellow indicator remains after startup, a software problem has been detected. Hardware status is undefined.
Flashing Yellow — Hardware problem detected. Software running normally.
Off — Appliance power is off.
Fans and power supplies
The 2200T device includes two hot-swappable power supplies. For more information, see Power supplies on page 43.
Note: The 2200T device includes three cooling fans. The fans for the 2200T device are redundant but not
hot-swappable. If a failure to a fan module occurs, you must replace the entire device.
External storage card
The TPS 2200T device includes a CFast card slot. The external storage card stores traffic logs, snapshots, and other system data. The card can be removed and inserted while the device is running; however, to do so, you must issue the appropriate unmounting, mounting, and preparation commands in the device CLI.
For more information, see External user disk on page 50 or the TPS CLI Reference for command syntax.
Ports
The 2200T device is equipped with eight RJ-45 ports that include integrated bypass support. In addition, the device provides a console and management port as shown in the following figure:
Threat Protection System Hardware Specification and Installation Guide 23
Page 30
Figure 9. TPS 2200T device – management and console ports
1. 1 RJ-45 serial console port
2. 1 GbE copper management port
3. Activity LED
4. Link LED
The management port LEDs indicate link and activity state, as described in the following table.
Table 9. TPS 2200T – port LED states
LED Type Color Description
Green Link is active at 1000 Mbps.Link
Off Link is inactive, or is active at 10 Mbps or 100 Mbps.
Blinking amber Data traffic is passing.Activity
Off No traffic is passing.
24 Threat Protection System Hardware Specification and Installation Guide
Page 31
In addition, the 2200T is equipped with eight 1G SFP ports and 4 10G SFP+ ports. ZPHA bypass support for SFP/SFP+ is provided through an external ZPHA device.

Model requirements

The following topics describe specific requirements for the 2200T device.
Power requirements on page 25
Cabling requirements on page 25

Power requirements

The TPS 2200T device requires Alternating Current (AC) that meets the following requirements:
AC: Voltage 100V to 240V; 12 to 6A; 47 to 63 Hz
The TPS 2200T device ships with two AC power supplies.

Cabling requirements

The TPS 2200T device ships with the following cables:
Two AC power cables, one for each hot-swappable power supply
Null modem cable (USB to RJ-45) for the serial console management port shown in Figure 9 on page 24

Pluggable transceivers

The 2200T device supports the following SFP and SFP+ pluggable transceivers:
1G SFP RJ45 T (Copper SFP)
1G SFP LC LX 10km 1310nm XCVR
1G SFP LC SX 550m 850nm XCVR
10G SFP+ LC SR
10G SFP+ LC LR
Note: Only optical transceiver modules (including SFP and SFP+) available from TippingPoint have been
validated to achieve optimal performance with TippingPoint products. Other vendor devices are not supported. Using other vendor devices could be detrimental to proper operation of the TippingPoint system.
The following table details the information for SFP and SFP+ transceivers.
Threat Protection System Hardware Specification and Installation Guide 25
Page 32
Table 10. Fiber input details
Fiber Input Signal
Left side Transmit
Right side Receive

Technical specifications

The TPS 2200T device has the following specifications.
Table 11. TPS 2200T – technical specifications
Specification Description
Dimensions (unpackaged)
Weight 26.26 lbs (11.91 kg)
Power Requirements AC: Voltage 100 to 240; Current 12 to 6A; Frequency 47to 63 Hz
Service Provider operating requirements
External interfaces
2U form factor – 3.46 in (H) x 16.77 in (W) x 18.80 in (D) (8.80 cm x 42.60 cm x
47.80 cm)
The appliance’s maximum power consumption is 493W.
Temperature: 32 to 104° F (0 to 40° C) — Operating
Temperature: -4 to 158° F (-20 to 70° C) — Storage
Altitude: No degradation up to 10,000 feet (3048m)
Humidity: 5% to 95% (non-condensing)
One 1 GbE copper management port
One RJ-45 console port
26 Threat Protection System Hardware Specification and Installation Guide
Page 33
Specification Description
Eight 1 GbE copper ports
Eight 1 GbE SFP fiber ports
Four 10 GbE SFP+ fiber ports
One HA port
One ZPHA port
One CFast slot
Threat Protection System Hardware Specification and Installation Guide 27
Page 34

TPS 440T product overview

This information describes the components, chassis, requirements, and installation specifics of the TPS 440T device. The following topics are discussed:
Device overview on page 28
Model requirements on page 32
Technical specifications on page 32
For information about installing the device, see Install your TPS device on page 34. Prior to installation, have the TPS CLI Reference available for configuration information.

Device overview

The 440T device is a small form-factor device designed for smaller network environments requiring up to 1 Gbps of inspection throughput. This model provides the same high-level security protection as the higher­capacity models.

Chassis – front panel

The TPS 440T device is a 1U form-factor device that is rack-mountable in a 19-inch rack (or 23-inch rack, with appropriate conversion parts available from rack accessory vendors).
The following image is a front panel view of a TPS 440T device:
Figure 10. TPS 440T device – front panel
1. CFast card
2. 1GB copper ports
3. Dedicated HA port
4. Serial console port/Management port
28 Threat Protection System Hardware Specification and Installation Guide
Page 35
5. Alert indicator
6. System status indicator
7. Power indicator

Chassis – rear panel

The following illustration shows a rear-panel view of a 440T device.
Figure 11. TPS 440T device – rear back panel
1. Fans (3)
2. AC power supply
3. AC power connector
4. Power switch

Chassis – features

The TPS 440T chassis features include the following elements:
Power switch and power indicator on page 29
System status indicator on page 30
Alert indicator on page 30
Fans and power supplies on page 30
External storage card on page 30
Ports on page 30
Power switch and power indicator
The power switch is located on the right side of the back panel. The power indicator on the front panel indicates the current power status of the device.
Threat Protection System Hardware Specification and Installation Guide 29
Page 36
No light — Device is powered off.
Green — Device is powered on.
System status indicator
The System Status indicator is located on the right side of the front panel and indicates the current operating status of the device.
Flashing Green — Device is booting and is not yet ready to inspect traffic.
Flashing Green/Yellow — Device is booting and BIOS or software is updating.
Solid Green — Device is running in a healthy state.
Solid Yellow — Device is running but has a health rating below the acceptable threshold.
Alert indicator
The Alert indicator is located on the right side of the front panel and indicates the current status of the software processes and the hardware.
Solid Green — Both the hardware and the software processes are running normally.
Solid Yellow — System is booting. If the solid yellow indicator remains after startup, a software problem has been detected. Hardware status is undefined.
Flashing Yellow — Hardware problem detected. Software running normally.
Off — Device power is off.
Fans and power supplies
The 440T device includes one power supply and five cooling fans (two of them are internal). These components are not customer-replaceable. For more information about these components, see Power supplies on page 43.
External storage card
The TPS 440T device includes a CFast card slot. The external storage card stores traffic logs, snapshots, and other system data. The card can be removed and inserted while the device is running; however, to do so, you must issue the appropriate unmounting, mounting, and preparation commands in the device CLI.
For more information about the procedure, refer to External user disk on page 50.
Ports
The TPS 440T device is equipped with eight copper ports. In addition, the device includes the console and management ports shown in the following figure:
30 Threat Protection System Hardware Specification and Installation Guide
Page 37
Figure 12. TPS 440T device – management and console ports
1. 1 RJ-45 serial console port
2. 1 GbE copper management port
3. Activity LED
4. Link LED
The management port LEDs indicate link and activity state, as described in the following table.
Table 12. TPS 440T – port LED states
LED Type Color Description
Green Link is active at 1000 Mbps.Link
Off Link is inactive, or is active at 10 Mbps or 100 Mbps.
Blinking amber Data traffic is passing.Activity
Off No traffic is passing.
Threat Protection System Hardware Specification and Installation Guide 31
Page 38

Model requirements

The following topics describe the power and cabling requirements for the TPS 440T device.
Power requirements on page 32
Cabling requirements on page 32

Power requirements

The TPS 440T device requires Alternating Current (AC) that meets the following requirements:
AC: Voltage 100V to 240V; 4 to 2A; 47 to 63 Hz
The TPS 440T device ships with one AC power supply.

Cabling requirements

The TPS 440T device ships with the following cables:
One AC power cable
Null modem cable (USB to RJ-45) for the serial console management port shown in Figure 12 on page 31

Technical specifications

The TPS 440T device has the following specifications.
Table 13. TPS 440T – technical specifications
Specification Description
Dimensions (unpackaged)
Weight 15.28 lbs (6.93 kg)
Power Requirements AC: Voltage 100 to 240; Current 4 to 2A; Frequency 50to 60 Hz
1U form factor – 1.73 in (H) x 16.78 in (W) x 17.72 in (D) (4.40 cm x 42.62 cm x
45.00 cm)
The device’s maximum power consumption is 250W.
32 Threat Protection System Hardware Specification and Installation Guide
Page 39
Specification Description
Service Provider operating requirements
External interfaces
Temperature: 32 to 104° F (0 to 40° C) — Operating
Temperature: -4 to 158° F (-20 to 70° C) — Storage
Altitude: No degradation up to 10,000 feet (3048 m)
Humidity: 5% to 95% (non-condensing)
One 1 GbE copper management port
One RJ-45 console port
Eight 1 GbE copper ports
One CFast slot
Threat Protection System Hardware Specification and Installation Guide 33
Page 40

Install your TPS device

After you have completed preparation procedures and unpacked the TPS device, you are ready to install and configure the components. Have the TPS CLI Reference available for configuration information reference. After installation of the hardware components, complete the initial setup wizard as part of the installation and configuration procedures.
Note: Before installing your device, review and adhere to all safety guidelines described the TPS Hardware
Safety and Compliance Guide, which also contains detailed regulatory compliance information and is
included with your product shipment.
This information includes the following procedures:
Install the chassis on page 34
Connect the power supply on page 35
Attach the cables on page 36
Check the LEDs on page 37
Run the setup wizard on page 38

Install the chassis

This information provides general guideline information for all TippingPoint devices. For installation guidelines specific to your TPS device, refer to the appropriate Install your security device quick start for your model available on the TMC at https://tmc.tippingpoint.com.
Before installing your new security device, gather any necessary materials and prepare the network and hardware site. To carefully and correctly install the device, read through all preparation instructions and requirements. This information provides general guideline information for all TippingPoint devices.
To install the device you must do the following:
Determine total rack space on page 34
Attach the device to the rack on page 35
Connect the power supply on page 35

Determine total rack space

Before you install the chassis, determine the total rack space that is required to install your system. The total required rack space increases if you plan to install multiple systems.
34 Threat Protection System Hardware Specification and Installation Guide
Page 41
The device fits in a 19-inch-wide rack (or a 23-inch-wide rack, with appropriate conversion parts available from rack accessory vendors). For more information about the dimensions of the device, refer to the technical specifications and requirements for your model.

Attach the device to the rack

Unpack the accessory kit and the slide rail assemby kit that shipped with your security appliance and review the installation documentation.
If the rack is partially filled, load the rack from the bottom to the top with the heaviest component at the bottom. During initial installation, make sure to evenly distribute the weight so that the rack is stable.
Important: Always use a four-post mount for four-post racks.
If you plan to expand your system to include additional TippingPoint systems in the future, allow space in the rack for additions. During the initial installation, keep in mind the weight distribution and stability of the rack.

Install the external storage card

For TPS 440T and 2200T security devices, install the CFast card that was packaged with your product into the empty slot on the front panel of the device. This pre-formatted, hot-swappable user disk can store system logs, snapshots, and other system data.
For TPS 8200TX and 8400TX security devices, the external SSD module is installed with the product. If you have a TPS TX Series device, you can skip this step.

Connect the power supply

After you have bolted the device to the rack, attach the power supply AC connections. Do not turn on the device until you have completed all of the remaining installation steps.
The TPS 2200T, 8200TX, and 8400TX security devices require the use of one power cord to turn on the device. Use a second power cord for redundancy. For maximum protection, use different power circuit feeds for each power cord.
Note: The TPS 440T provides a single power supply.
When you install DC power, always install the safety ground cable before connecting the power supply. For DC power connection details, refer to the product hardware documentation.
To connect the power supply
1. Locate the power inlets on the back of the chassis.
2. Plug the female end of a standard power cord into the power inlet and plug the other end of the power cord into an AC outlet, power strip, or UPS.
Threat Protection System Hardware Specification and Installation Guide 35
Page 42

Add the I/O modules – TPS TX Series

TPS TX Series devices come with blank modules inserted into I/O module slots. The TPS 8200TX provides two I/O slots and the TPS 8400TX provides four I/O slots.
Warning!
For detailed information about I/O module installation, see I/O module installation on page 13.
Figure 13. Blank modules
1. To remove the blank module, slide the slide latch (1) to the right and pull on the handle (2 on left module) or grab point (2 on right module).
Do not leave slots empty for an extended period of time. Insertion of a blank module or I/O module ensures that the device is correctly cooled.
Caution: Never lift your device using the module handles.
2. To insert an I/O module, slide the module into the empty module slot.
When the module is in the correct position, the slide latch automatically slides into position.
Important: When you insert a bypass I/O module, the bypass I/O module always starts up in bypass
mode. A bypass I/O module remains in bypass mode until you remove it from bypass mode through the CLI, LSM, or SMS. Rebooting the TPS does not change the bypass mode of the bypass I/O module. For information about how to disable bypass mode, see your product documentation on the TMC.

Attach the cables

During initial setup, use the management processor connection or the console port to access the setup wizard.
36 Threat Protection System Hardware Specification and Installation Guide
Page 43

Connect the console port

Describes how to connect the console port.
1. Connect the RJ-45 null modem cable to the console port on the front of the unit.
2. Connect the other end of your cable (standard USB connector) to your computer.
Use the following terminal settings for the console port:
Baud rate: 115.2 Kbps
Character size: 8 bits
Parity: None
Stop Bits: One
Flow Control: None

Connect the management port

Describes how to connect the management port.
1. Connect one end of the Category 5 Ethernet cable to the port labeled MGMT located on the front panel.
2. Connect the other end of the Ethernet cable to your network. This enables remote management.

Turn on the device

After you have reviewed all requirements for operating your product, turn on the device:
To turn on a TPS 440T device, flip the power switch on the back panel of the device.
To turn on a TPS 2200T, 8200TX, or 8400TX security device, use the power button located on the front panel of the device.

Check the LEDs

When you connect power to the device, the system completes a series of component checks. It then displays LEDs to show the status of each component. For more information, see the LED status for your product:
TPS TX Series device: Chassis – features on page 10
TPS 2200T device: Chassis – features on page 22
TPS 440T device: Chassis – features on page 29
Threat Protection System Hardware Specification and Installation Guide 37
Page 44

Run the setup wizard

From the console terminal, complete the initial configuration by using the setup wizard. The wizard performs system checks and then prompts you to complete the initial setup.
After you run the setup, you can further configure your system using subsequent setup commands through the device CLI. See the TPS CLI Reference for detailed command descriptions.
1. Specify a security level (None, Low, Medium, or High). The security level you select determines your password complexity requirements.
2. Create an administrative account with the SuperUser role. The SuperUser role gives the account full access to the device. For more information about user accounts, review the documentation for your product on the TMC.
The wizard prompts you to log in with your administrative account so that you can continue initial setup.
3. From the console port terminal, log in with your administrative account.
The wizard prompts you to configure IP address, default gateway, DNS server, and timekeeping options.

Install your license package

Install your license package on the device to provide the following product capabilities:
Inspection throughput
Digital Vaccine
ThreatDV
SSL inspection
Update your license package to assign a product capability that you have purchased, such as an inspection throughput license, to a particular security device. To review and manage the capabilities in your license package, go to the TippingPoint License Manager on the TMC at https://tmc.tippingpoint.com.
Important: Verify your product license provides sufficient inspection throughput. By default, a TPS
security device is unlicensed and provides reduced inspection throughput for testing and evaluation purposes only.
Table 14. TPS devices – unlicensed inspection throughput
Security device Unlicensed inspection throughput
8400TX 1 Gbps
38 Threat Protection System Hardware Specification and Installation Guide
Page 45
Security device Unlicensed inspection throughput
8200TX 1 Gpbs
2200T 200 Mbps
440T 100 Mbps

Attach network connections

Describes how to make network connections.
All ports on the TPS device are dynamic and do not require fixed cable assignments. When making your network cable connections, keep track of which ports you select for which purpose.
1. Attach one or more network cables for the internal network. Make note of which front panel ports you use.
2. Attach a network cable for the external (WAN) network. Make note of which front panel port you use.
3. Using the LSM or the command line interface, configure network interface types appropriate to the surrounding network using the ports you selected.
For more information about device network configuration and connections, refer to the TPS Local Security Manager User Guide and the TPS CLI Reference.

Where to go next

After you attach network connections, network traffic passes through the device using the default filter configuration. The default configuration automatically recognizes and blocks traffic that is known to be malicious at all times, under all conditions, in all network environments.
On a TX Series device, any bypass I/O modules remain in bypass mode until you remove them from bypass mode through the CLI, LSM, or SMS. Rebooting the TPS does not change the bypass mode of the bypass I/O module. For information about how to disable bypass mode, see your product documentation on the TMC.
Note: To complete your installation, see the Release Notes for your product on the TMC at https://
tmc.tippingpoint.com. The Release Notes provide the latest post-installation information for your product.
You can perform additional configuration, administrative, and management tasks, by using:
The LSM or the device command line interface (CLI). The LSM and CLI enable straightforward management of a particular device.
Threat Protection System Hardware Specification and Installation Guide 39
Page 46
Note: From the CLI, you can repeat the setup wizard by using the setup command. When you use the CLI, configure the terminal emulation package to transmit a Ctrl-H character when the Backspace key is pressed.
The SMS. The TippingPoint SMS provides a scalable, policy-based operational model, and enables straightforward management of large-scale IPS and TPS deployments.
40 Threat Protection System Hardware Specification and Installation Guide
Page 47

Connector and cable pinout specifications

This information provides connector and pinout information for TPS devices and contains the following topics:
RJ-45 (COM) console on page 41
RJ-45 Ethernet connectors on page 42

RJ-45 (COM) console

Describes the RJ-45 (COM) console specifications.
The following figure displays the RJ-45 connector and the following table shows the RJ-45 console connector pinouts.
Figure 14. RJ-45 connector
Table 15. RJ-45 console connector pinouts
Pin number Signal name
1 Request to Send (RTS)
2 Data Terminal Ready (DTR)
3 Transmit Data (TxD)
4 Ground (GND)
5 Ground (GND)
6 Receive Data (RxD)
7 Data Set Ready (DSR)
Threat Protection System Hardware Specification and Installation Guide 41
Page 48
Pin number Signal name
8 Clear to Send (CTS)

RJ-45 Ethernet connectors

Provides pinout information for when your RJ-45 device is operating in 10Mbps/100Mbps mode.
Table 16. RJ-45 pinout information
Pin number Signal name
1 Transmit positive (Tx+)
2 Transmit negative (Tx-)
3 Receive positive (Rx+)
4 Ground (GND)
5 Ground (GND)
6 Receive negative (Rx-)
7 Ground (GND)
8 Ground (GND)
42 Threat Protection System Hardware Specification and Installation Guide
Page 49

Power supplies

This topic provides information for using the power supply modules. The following subjects are discussed.
AC power supply – TPS 2200T and TX Series on page 43
DC power supply – TPS TX Series on page 44
Warning!
Note: The TPS 2200T device has hot-swappable power supplies; there are no other serviceable parts inside.
There are no hot-swappable or serviceable parts inside the TPS 440T device.
This product might have more than one power supply source. All power sources must be removed to de-energize the unit.

AC power supply – TPS 2200T and TX Series

The TPS 2200T and TX Series devices include two power supply modules. The modules are hot-swappable, redundant, and current-sharing, and the appliance can run with one active module.
Figure 15. 2200T AC power supply
1. Removal Latch
2. Handle
3. Status LED
4. AC male power input
Threat Protection System Hardware Specification and Installation Guide 43
Page 50
The Status LED is green when the module is powered and running normally.

Connect the AC power supply

Describes how to connect the power supply to your device.
When the AC power supply has been securely placed in the device, use the following procedure to connect power to the AC power supply:
1. Locate the male power input on the back of the chassis.
2. Plug one end of a standard female power plug into the power input.
3. Plug the other end into an AC outlet, power strip, or UPS. For information about the power requirements for your product, see the following sections:
TX Series devices – Technical specifications on page 18
2200T device – Technical specifications on page 26.
440T device – Technical specifications on page 32
The TPS device returns to its previous power-on state in the event of a power interruption. If power was on when the interruption occurred, the device automatically powers back on when the power is reconnected; if power was off, the device stays off when the power is reconnected. If necessary, power on the device with the button on the front of the chassis.

DC power supply – TPS TX Series

The TPS TX Series devices are NEBS compliant and can accept a combination of AC and DC power supply units. Consult your TippingPoint account contact for more information on obtaining DC power supplies.
Warning!

Connect the DC power supply

Warning!
Caution:
The power supply LED is green when the module is powered and running normally.
Do not attempt to install a DC power supply into a 440T device. The 440T device does not contain the grounding capability for safe installation of a DC power supply. Bodily harm and damage to the system could result.
When installing the product, always make the ground connection before applying power to the unit. This equipment needs to be grounded to an external ground connection. Use a green and yellow 12 AWG ground wire to connect the host to earth ground during normal use. Disconnect the ground connection only when the unit is completely powered down.
Do not attach a ground wire to the ground screw on the DC power supply module. Attach the ground wire to the 2200T chassis DC grounding screw holes (0.63-inch hole spacing) with #10 screws. The DC grounding screw holes are located in the rear of the chassis.
44 Threat Protection System Hardware Specification and Installation Guide
Page 51
When the DC power supply has been securely placed in the device, use the following procedure to connect power to the DC power supply.
1. Locate the ground screw on the back of the chassis.
Refer to the following figure for the location.
Figure 16. TPS TX Series devices - DC grounding screw holes
2. Attach a 12 AWG ground wire to the chassis ground strap mounting.
The wire should be crimped with a ring lug.
3. Locate the power input terminal block on the back of the module.
4. Attach the 12 AWG DC power wires to the power input terminal block labeled -48V and RTN.
The power wires should be crimped with lug spades to ensure a secure connection.
5. Connect the other side of the power cable to the SELV power source.
The power source should meet the following requirements:
Voltage: -40 to -60 V
24 to 16 Amps
SELV
6. Depending on the BIOS settings and the state the device was in when the power was unplugged, the device might or might not turn on automatically when power is reapplied. If necessary, power on the device with the button on the front of the chassis.
Threat Protection System Hardware Specification and Installation Guide 45
Page 52

Fans

The 440T device includes five cooling fans (two of them are internal). The fans are not redundant or hot­swappable. If a failure to a fan module occurs, you must replace the entire device.
The 2200T device includes three cooling fans. The fans for the 2200T device are redundant but not hot­swappable. If a failure to a fan module occurs, you must replace the entire device.
The TPS TX Series devices include seven cooling fans. The fans for the 8200TX and 8400TX devices are redundant and hot-swappable. An individual fan can be replaced without powering down the device.
The TPS TX Series Spare Fan (TPNN0266) is a replacement unit and can only be used with TPS TX Series devices.
Figure 17. TPS TX Series – fan module
When a fan module fails or its RPM rate falls below a certain threshold, the system generates a warning or critical alarm message in its logs.
You can check fan performance by using:
The LSM: System Health > Monitor > Fan Speed
The device CLI: show health fan

Replace the fan – TPS TX Series

Describes how to replace the fan on the TPS 8200TX and 8400TX security devices.
46 Threat Protection System Hardware Specification and Installation Guide
Page 53
The fan modules are hot-swappable and can be replaced when the device is operating. After you have identified the faulty fan assembly, follow this procedure to replace the fan:
1. Press the release tab on the right side of the fan module and pull the module from its slot.
2. Set the faulty fan module aside.
3. Remove the new fan module from the packaging.
4. Align the new fan module with its open slot, and then slide the unit in until it is seated in the connector.
After you insert the fan module, the system verifies the fan speed.
Threat Protection System Hardware Specification and Installation Guide 47
Page 54

Power cord retention bracket

The power cord retention bracket lets you manage the placement of power cords for minimal obtrusiveness.
The following subjects are discussed:
Overview on page 48
Install the retention bracket on page 48
Use the power cord retention bracket on page 49
Remove the bracket on page 49

Overview

The power cord retention bracket helps reduce strain on the power cord and power supply outlets.
Figure 18. Power Cord retention bracket

Install the retention bracket

The following figure shows a TPS 2200T device with the power cord retention bracket installed:
48 Threat Protection System Hardware Specification and Installation Guide
Page 55
Figure 19. TPS 2200T device – back panel with retention bracket
To install the retention bracket:
1. Orient the bracket against the back surface of the chassis.
2. Slide the bracket over the two shoulder rivets on the back of the chassis.
The spring-loaded plunger in the center of the bracket slides into place.

Use the power cord retention bracket

Follow this procedure to attach the power cord to the retention bracket:
1. Fold the power cable and slide it into the slot.
2. Push the folded cable into the slot until the cable loop goes past the sheet metal tabs.
3. Secure the folded cable loop under the sheet metal tabs and attach the power cable to the power supply.

Remove the bracket

If you need to remove one of the brackets, pull the spring-loaded plunger in the middle of the bracket and slide the bracket up and off the shoulder rivets.
Threat Protection System Hardware Specification and Installation Guide 49
Page 56

External user disk

This information describes the external user disk (CFast or SSD) and provides the following topics:
External SSD on page 50
External CFast storage card on page 50
External user disk commands on page 51

External SSD

The TPS TX Series devices come with a pre-formatted external SSD.
Note: Only SSDs available from TippingPoint have been validated to achieve optimal performance with
TippingPoint products. Other vendor drives are not supported. Using other vendor drives could be detrimental to proper operation of the TippingPoint system.
The external SSD is a 32 GB drive that stores traffic logs, snapshots, and other system data.
Caution:
You can replace the SSD when the system is operating. Before you remove the SSD, use the device CLI to first unmount the drive. For more information, External user disk commands on page 51.
Important: After you insert a new SSD module into the SSD slot, be sure to mount the user disk. Failure
Failure to properly remove the TippingPoint SSD can result in disk corruption and a system error.
to mount the user disk prevents the device from automatically mounting the disk when the device is rebooted.

External CFast storage card

The TPS 440T and 2200T devices come with a pre-formatted external CFast storage card.
Note: Only CFast cards available from TippingPoint have been validated to achieve optimal performance
with TippingPoint products. Other vendor cards are not supported. Using other vendor cards could be detrimental to proper operation of the TippingPoint system.
The external CFast card is an 8 GB card that stores traffic logs, snapshots, and other system data.
Caution:
Failure to properly remove the TippingPoint CFast card can result in disk corruption and a system error.
You can replace the CFast card when the system is operating. Before you remove the card, use the device CLI to first unmount the user disk. For more information, see External user disk commands on page 51.
50 Threat Protection System Hardware Specification and Installation Guide
Page 57
Important: After you insert a new card into the CFast slot, be sure to mount the user disk. Failure to
mount the user disk prevents the device from automatically mounting the disk when the device is rebooted.

External user disk commands

Lists the commands used to manage the external user disk (CFast or SSD) in the CLI.
Refer to the TPS CLI Reference for detailed documentation of these commands.
Table 17. External user disk CLI commands
Command Description
user-disk format Formats the external user disk. Any existing data on the external
user disk will be erased.
user-disk mount Manually mounts the external user disk.
Important: If you replace the external user disk while the device
is turned off, be sure to also restore power to the device so that you can mount the replacement disk. Failure to mount the replacement disk prevents the device from automatically mounting the disk when the device is rebooted.
user-disk unmount Unmounts the external user disk so that the user can remove it.
user-disk encryption enable
Encrypts the external user disk if the system master key has been set. Changing the encryption status reformats the external user disk and erases all data on the drive.
Note: Master key and encryption controls can also be configured
using System > Settings > Data Security in the LSM. For more information, refer to the Local Security Manager User Guide.
Threat Protection System Hardware Specification and Installation Guide 51
Page 58
Command Description
user-disk encryption disable
Disables encryption of the external user disk if the system master key has been set. Changing the encryption status reformats the card and erases all data on the drive.
Note: Master key and encryption controls can also be configured
using System > Settings > Data Security in the LSM. For more information, refer to the Local Security Manager User Guide.
show user-disk Shows properties of the external user disk, including operation
status and capacity.
master-key set Encrypts the external user disk and the system keystore by using
the system master key. You are prompted to enter a master key that is between 9 and 32 characters in length, contains a combination of numbers and uppercase and lowercase letters, and that has at least one special character (for example, !@#).
Note: Master key and encryption controls can also be configured
using System > Settings > Data Security in the LSM. For more information, refer to the Local Security Manager User Guide.
52 Threat Protection System Hardware Specification and Installation Guide