Trend Micro Incorporated makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of
merchantability and fitness for a particular purpose. Trend Micro Incorporated shall not be liable for errors contained herein or for incidental or
consequential damages in connection with the furnishing, performance, or use of this material.
This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or
translated into another language without the prior written consent of Trend Micro Incorporated. The information is provided “as is” without warranty
of any kind and is subject to change without notice. The only warranties for Trend Micro Incorporated products and services are set forth in the
express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty.
Trend Micro Incorporated shall not be liable for technical or editorial errors or omissions contained herein.
TippingPoint, the TippingPoint logo, and Digital Vaccine are trademarks or registered trademarks of Trend Micro Incorporated. All other company
and/or product names may be trademarks or registered trademarks of their respective owners. This document contains confidential information, trade
secrets or both, which are the property of Trend Micro Incorporated. No part of this documentation may be reproduced in any form or by any means
or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from Trend Micro Incorporated or
one of its subsidiaries.
All other company and product names may be trademarks of their respective holders.
TippingPoint Threat Protection System Hardware Specification and Installation Guide
Publication Part Number: 5900-4108
Page 3
Contents
About this guide......................................................................................................................................1
Hardware installation and configuration............................................................................................... 20
Installing the TPS device..................................................................................................................... 21
Install the chassis................................................................................................................................. 21
Determine total rack space................................................................................................................21
Attach the device to the rack............................................................................................................ 22
Rack-mounting the TPS 440T device.............................................................................................22
ivThreat Protection System Hardware Specification and Installation Guide
Page 7
About this guide
Welcome to the installation and specification guidelines for your Threat Protection System (TPS) device.
This section covers the following topics:
•Target audience on page 1
•Related documentation on page 1
•Conventions on page 1
•Product support on page 2
Target audience
The intended audience includes technicians and maintenance personnel responsible for installing,
configuring, and maintaining TippingPoint security systems and associated devices.
•Basic networking
•Network security
•Routing
Related documentation
A complete set of documentation for your product is available on the TippingPoint Threat Management
Center (TMC) at: https://tmc.tippingpoint.com. The documentation generally includes installation and user
guides, command-line interface (CLI) references, safety and compliance information, and release notes.
Conventions
This information uses the following conventions.
Typefaces
TippingPoint uses the following typographic conventions for structuring information.
ConventionElement
Bold font
•Key names
•Text typed into a GUI element, such as into a box
Threat Protection System Hardware Specification and Installation Guide1
Page 8
ConventionElement
•GUI elements that are clicked or selected, such as menu and list items,
buttons, and check boxes. Example: Click OK to accept.
Italics fontText emphasis, important terms, variables, and publication titles
Monospace font
•File and directory names
•System output
•Code
•Text typed at the command-line
Monospace, italic
•Code variables
font
•Command-line variables
Monospace, bold
font
Messages
Emphasis of file and directory names, system output, code, and text typed
at the command line
Messages are special text that is emphasized by font, format, and icons.
Warning!
Alerts you to potential danger of bodily harm or other potential harmful consequences.
Caution:
Provides information to help minimize risk, for example, when a failure to follow directions
could result in damage to equipment or loss of data.
Note: Provides additional information to explain a concept or complete a task.
Important: Provides significant information or specific instructions.
Tip: Provides helpful hints and shortcuts, such as suggestions about how to perform a task more easily or
more efficiently.
Product support
Get support for your product by using any of the following options:
Email support
2Threat Protection System Hardware Specification and Installation Guide
Page 9
tippingpoint.support@trendmicro.com
Phone support
North America: +1 866 681 8324
International: See https://tmc.tippingpoint.com
Threat Protection System Hardware Specification and Installation Guide3
Page 10
Overview
The TippingPoint Threat Protection System (TPS) is a high-performance, enterprise-class solution that
protects your network by scanning, detecting, and responding to network traffic according to the filters,
action sets, and global settings maintained on each device by a client.
The TPS offers higher throughput and improved technology that is optimized for high resiliency, high
availability, and network segment protection from both external and internal attacks.
The following topics are covered:
•TPS devices on page 4
•Core hardware features on page 4
TPS devices
The TPS device delivers world-class defense against network intrusion and provides application control.
•The Threat Suppression Engine (TSE) scans, detects, and responds to network traffic according to the
filters, action sets, and global settings maintained on each device by a client.
•Built-in intrinsic high-availability features guarantee that the network keeps running in the event of a
system failure.
You can install as many TippingPoint security devices as you need to strategically protect your network
enterprise zones. A local client on the device monitors and manages activity. Alternatively, you can manage
devices by using the Security Management System (SMS) console.
Core hardware features
The TPS family includes the 440T device and the 2200T device.
These robust, high-performance security devices offer a scalable solution to support all types of
organizations and network environments.
440T device
Figure 1. 440T device
4Threat Protection System Hardware Specification and Installation Guide
Page 11
The 440T device has the following hardware features:
Feature440T device
Copper ports8
1GbE SFP portsNone
10GbE SFP+ portsNone
Power supplyOne 350W (built-in)
System memory16GB
External CFast card1 (8GB)
Replaceable fansNo
High Availability (HA)Yes
Zero Power High Availability (ZPHA)Built-in ZPHA on the 8 copper ports
In addition, the device includes:
•Built-in intrinsic high-availability features, guaranteeing continuity in the event of system failure
•Up to 500 Mbps aggregate across all four segments
•Encryption for VPN service
Threat Protection System Hardware Specification and Installation Guide5
Page 12
•Device management through the Local Security Manager (LSM) or centralized management through the
Security Management System (SMS).
2200T device
Figure 2. 2200T device
The 2200T device has the following hardware features:
Feature2200T device
Copper ports8
1GbE SFP ports8
10GbE SFP+ ports4
Power supplyTwo 750W (removeable)
System memory64GB
External CFast card1 (8GB)
Replaceable fansYes
6Threat Protection System Hardware Specification and Installation Guide
Page 13
Feature2200T device
High Availability (HA)Yes
Zero Power High Availability (ZPHA)*Built-in ZPHA for copper segments
External ZPHA port for SFP and SFP+ segments
*For information on installing and operating a ZPHA module, refer to TippingPoint Modular Fiber/CopperZPHA Installation Guide available on the TMC (http://tmc.tippingpoint.com).
In addition, the device includes:
•Built-in intrinsic high-availability features for copper segments, guaranteeing continuity in the event of
system failure
•Up to 2Gbps aggregate across all 10 segments
•Encryption for VPN service
•Device management through the Local Security Manager (LSM) or centralized management through the
Security Management System (SMS).
Threat Protection System Hardware Specification and Installation Guide7
Page 14
TippingPoint 440T hardware description
This information describes the components, chassis, requirements, and installation specifics of the
TippingPoint 440T device. The following topics are discussed:
•Device overview on page 8
•Model requirements on page 12
•Technical specifications on page 12
•Installing the device on page 13
For information about installing the device, see Installing the TPS device on page 21. Prior to installation,
have the CLI Reference available for configuration information.
Device overview
The 440T device is a small form-factor device designed for smaller network environments in which traffic
throughput requirements are 500Mbps or less. This model provides the same high-level security protection
as the higher-capacity models.
Chassis Front Panel
The 440T device is a 1U form-factor device that is rack-mountable in a 19-inch rack (or 23-inch rack, with
appropriate conversion parts available from rack accessory vendors).
The following image is a front panel view of a 440T device:
Figure 3. 440T device front panel
1. CFast card
2. 1GB copper ports
3. Dedicated HA port
8Threat Protection System Hardware Specification and Installation Guide
Page 15
4. Serial console port/Management port
5. Alert indicator
6. System status indicator
7. Power indicator
Chassis back panel
The following illustration shows a rear-panel view of a 440T device.
Figure 4. 440T device back panel
1. Fans (3)
2. AC power supply
3. AC power connector
4. Power switch
Chassis features
The chassis features include the following elements:
•Power switch and power indicator on page 10
•System status indicator on page 10
•Alert indicator on page 10
•Fans and power supplies on page 10
•External storage card on page 10
•Ports on page 11
Threat Protection System Hardware Specification and Installation Guide9
Page 16
Power switch and power indicator
The power switch is located on the right side of the back panel. The power indicator on the front panel
indicates the current power status of the device.
•No light — Device is powered off.
•Green — Device is powered on.
System status indicator
The System Status indicator is located on the right side of the front panel and indicates the current operating
status of the device.
•Flashing Green — Device is booting and is not yet ready to inspect traffic.
•Flashing Green/Yellow — Device is booting and BIOS or software is updating.
•Solid Green — Device is running in a healthy state.
•Solid Yellow — Device is running but has a health rating below the acceptable threshold.
Alert indicator
The Alert indicator is located on the right side of the front panel and indicates the current status of the
software processes and the hardware.
•Solid Green — Both the hardware and the software processes are running normally.
•Solid Yellow — System is booting. If the solid yellow indicator remains after startup, a software
problem has been detected. Hardware status is undefined.
•Flashing Yellow — Hardware problem detected. Software running normally.
•Off — Device power is off.
Fans and power supplies
The 440T device includes one power supply and five cooling fans (two of them are internal). These
components are not customer-replaceable. For more information about these components, see Power supply
and fan modules on page 33.
External storage card
The 440T device includes a CFast card slot. The external storage card stores traffic logs, snapshots, and
other system data. The card can be removed and inserted while the device is running; however, to do so,
you must issue the appropriate unmounting, mounting, and preparation commands in the command line
interface (CLI).
For more information about the procedure, refer to Using the external CFast storage card on page 40.
10Threat Protection System Hardware Specification and Installation Guide
Page 17
Ports
The device is equipped with eight copper ports. In addition, the device includes the console and
management ports shown in the following figure:
Figure 5. Management and Console ports
1. 1 RJ-45 serial console port
2. 1GbE copper management port
3. Activity LED
4. Link LED
The management port LEDs indicate link and activity state, as described in the following table.
LED TypeColorDescription
GreenLink is active at 1000Mbps.Link
OffLink is inactive, or is active at 10Mbps or 100Mbps.
ActivityBlinking amberData traffic is passing.
Threat Protection System Hardware Specification and Installation Guide11
Page 18
LED TypeColorDescription
OffNo traffic is passing.
Model requirements
The following topics describe the power and cabling requirements for the 440T device.
•Power requirements on page 12
•Cabling requirements on page 12
Power requirements
The 440T device requires one input of Alternating Current (AC) that must meet the following requirements:
•AC: Voltage 100V – 240V; 4 – 2 amp; 50 – 60 Hz
Cabling requirements
The 440T device ships with the following cables:
•One AC power cable
•Null modem cable for the serial console management port (DB-9 to RJ-45) shown in Figure 5 on page
11
Technical specifications
The 440T device has the following specifications.
SpecificationDescription
Dimensions
(unpackaged)
Weight15.28 lbs (6.93 kg)
Power RequirementsAC: Voltage 100 – 240; Current 4 – 2 A; Frequency 50– 60 Hz
1.73 in (H) x 16.78 in (W) x 17.72 in (D) (4.40 cm x 42.62 cm x 45.00 cm)
The device’s maximum power consumption is 142 W.
12Threat Protection System Hardware Specification and Installation Guide
Page 19
SpecificationDescription
Service Provider
operating
Temperature: 32 – 104° F (0 – 40° C) — Operating
Temperature: -4 – 158° F (-20 – 70° C) — Storage
requirements
External interfaces
Altitude: No degradation up to 10,000 feet (3048 m)
Humidity: 5% to 95% (non-condensing)
•1 – 1GbE copper management port
•1 – RJ-45 console port
•8 – 1GbE copper ports
•1 external storage card drive
Installing the device
To install and complete installation setup of the device, see Installing the TPS device on page 21.
Threat Protection System Hardware Specification and Installation Guide13
Page 20
TippingPoint 2200T hardware description
This information describes the components, chassis, requirements, and installation specifics of the
TippingPoint 2200T device. The following topics are discussed:
•2200T device overview on page 14
•Model requirements on page 19
•Technical specifications on page 19
•Hardware installation and configuration on page 20
For information about installing the device, see Installing the TPS device on page 21. Prior to installation,
have the CLI Reference available for configuration information.
2200T device overview
The 2200T device is a mid-range system that has a larger form factor than the 440T device and is designed
for network environments requiring inspection of inbound Secure Socket Layer (SSL) traffic throughput
rates between 1Gbps and 2Gbps. These models provide the same high-level of security protection as the
highest-capacity models.
Chassis front panel
The 2200T device is a 2U form-factor devices that are rack-mountable in a 19-inch rack (or 23-inch rack,
with appropriate conversion parts available from rack accessory vendors). These appliances support
throughput across multiple copper and fiber ports.
The following illustration shows a front panel view of the 2200T device:
Figure 6. 2200T device front panel
14Threat Protection System Hardware Specification and Installation Guide
Page 21
1. 10GbE SFP+ ports
2. 1GbE SFP ports
3. 1GbE copper ports
4. External CFast card
5. Dedicated HA port
6. ZPHA port
7. Console/Management port
8. Power button
9. Alert indicator
10. System status indicator
2200T chassis back panel
The following illustration shows the rear-panel view of a 2200T device.
Figure 7. 2200T device back panel
Threat Protection System Hardware Specification and Installation Guide15
Page 22
1. Fans (3)
2. Power supplies (2)
2200T chassis features
The chassis features include the following elements:
•Power button on page 16
•System status indicator on page 17
•Alert indicator on page 17
•Fans and power supplies on page 17
•External storage card on page 17
•Ports on page 17
Power button
The power button is located on the right side of the console/management ports on the front panel. The
power button light indicates the current status of the appliance.
•No light — Appliance is powered off.
•Green — Appliance is powered on.
16Threat Protection System Hardware Specification and Installation Guide
Page 23
System status indicator
The System Status indicator is located on the right side of the front panel and indicates the current operating
status of the appliance.
•Flashing Green — Appliance is booting and is not yet ready to inspect traffic.
•Flashing Green/Yellow — Appliance is booting and BIOS or software is updating.
•Solid Green — Appliance is running in a healthy state.
•Solid Yellow — Appliance is running but has a health rating below the acceptable threshold.
Alert indicator
The Alert indicator is located on the right side of the front panel and indicates the current status of the
software processes and the hardware.
•Solid Green — Both the hardware and the software processes are running normally.
•Solid Yellow — System is booting. If the solid yellow indicator remains after startup, a software
problem has been detected. Hardware status is undefined.
•Flashing Yellow — Hardware problem detected. Software running normally.
•Off — Appliance power is off.
Fans and power supplies
The 2200T device includes two power supplies and three cooling fans. These components are hot-pluggable.
For more information about these components, see Power supply and fan modules on page 33.
External storage card
The 2200T device includes a CFast card slot. The external storage card stores traffic logs, snapshots, and
other system data. The card can be removed and inserted while the appliance is running; however, to do so,
you must issue the appropriate unmounting, mounting, and preparation commands in the command line
interface (CLI). Refer to Using the external CFast storage card on page 40 or the CLI Reference for command
syntax.
For more information about configuring the external CFast card, refer to Using the external CFast storage card
on page 40.
Ports
All TPS devices, including the 2200T device, are equipped with eight copper ports in addition to the console
and management ports shown in the following figure:
Figure 8. Management and console ports
Threat Protection System Hardware Specification and Installation Guide17
Page 24
1. 1 RJ-45 serial console port
2. 1GbE copper management port
3. Link LED
4. Activity LED
The management port LEDs indicate link and activity state, as described in the following table.
LED TypeColorDescription
GreenLink is active at 1000Mbps.Link
OffLink is inactive, or is active at 10Mbps or 100Mbps.
Blinking amberData traffic is passing.Activity
OffNo traffic is passing.
18Threat Protection System Hardware Specification and Installation Guide
Page 25
Model requirements
The following topics describe specific requirements for the 2200T device.
•Power requirements on page 19
•Cabling requirements on page 19
Power requirements
The 2200T device requires one input of Alternating Current (AC) or Direct Current (DC) that must meet
the following requirements:
•AC: Voltage 100V – 240V; 12 – 6 amp; 50 – 60 Hz
•DC: Voltage -40V – -60V; 24 – 16 amp; SELV power source
The 2200T device ships with two AC power supplies. DC power supplies are also available for the device.
Consult your TippingPoint account contact for more information if you require a DC power supply.
Cabling requirements
The 2200T device ships with the following cables:
•Two AC power cables, one for each hot-pluggable power supply
•Null modem cable for the serial console management port (DB-9 to RJ-45) shown in Figure 8 on page
17
Technical specifications
The 2200T device has the following specifications.
SpecificationDescription
Dimensions
(unpackaged)
Weight26.26 lbs (11.91 kg)
Power RequirementsAC: Voltage 100 – 240; Current 12 – 6 A; Frequency 47– 63 Hz
2U – 3.46 in (H) x 16.77 in (W) x 18.80 in (D) (8.80 cm x 42.60 cm x 47.80 cm)
DC: Voltage -40V – -60V; 24 – 16 amp; SELV power source
Threat Protection System Hardware Specification and Installation Guide19
Page 26
SpecificationDescription
The appliance’s maximum power consumption is 493 W.
Service Provider
operating
requirements
External interfaces
Temperature: 32 – 104° F (0 – 40° C) — Operating
Temperature: -4 – 158° F (-20 to 70° C) — Storage
Altitude: No degradation up to 10,000 feet (3048 m)
Humidity: 5% to 95% (non-condensing)
•1x1GbE copper management port
•1x1 RJ-45 console port
•8 – 1GbE copper ports
•8 – 1GbE SFP fiber ports
•4 – 10GbE SFP+ fiber ports
•1 HA port
•1 ZPHA port
•1 external storage card drive
Hardware installation and configuration
For general instructions on installing the 2200T device, see Installing the TPS device on page 21.
20Threat Protection System Hardware Specification and Installation Guide
Page 27
Installing the TPS device
After you have completed preparation procedures and unpacked the TPS device, you are ready to install
and configure the components. Have the CLI Reference available for configuration information reference.
After installation of the hardware components, complete the OBE Setup Wizard requirements as part of the
installation and configuration procedures.
Note: Before installing your device, review and adhere to all safety guidelines described the Hardware Safety
and Compliance Guide, which also contains detailed regulatory compliance information and is included
with your product shipment.
This information includes the following procedures:
•Install the chassis on page 21
•Connect the power supply on page 28
•Attach cables on page 28
•Check LEDs on page 29
•Run the setup wizard on page 29
Install the chassis
Before installing your new security device, gather any necessary materials and prepare the network and
hardware site. To carefully and correctly install the device, read through all preparation instructions and
requirements. This information provides general guideline information for all TippingPoint devices.
To install the device you must do the following:
•Determine total rack space on page 21
•Attach the device to the rack on page 22
•Connect the power supply on page 28
Determine total rack space
Before you install the chassis, determine the total rack space that is required to install your system. The total
required rack space increases if you plan to install multiple systems.
The device fits in a 19-inch-wide rack (or a 23-inch-wide rack, with appropriate conversion parts available
from rack accessory vendors). For more information about the dimensions of the device, refer to the
technical specifications and requirements for your model.
Threat Protection System Hardware Specification and Installation Guide21
Page 28
Attach the device to the rack
The TPS 440T device ships with a four-post rack-mount kit to mount the device to a rack. You can use this
kit to install the device in a two-post or four-post rack.
The TPS 2200T device ships with a slide rail kit to mount this device to a four-post rack and mounting ears
for two-post racks. Slide rail kits are also available for order from TippingPoint. Refer to the instructions in
the slide rail kit for information about installing the slide rails.
For two-post racks, use the front mounting ears to install 2200T devices in either front-mount or midmount positions.
Your device shipment includes the following mounting hardware:
•Front-mounting brackets for a 19-inch rack. Adapters (available from rack accessory vendors) are
required for posting in a 23-inch rack.
•Rear-mounting brackets for mounting a 440T device in a 19-inch rack. Adapters (not included) are
required for posting in a 23-inch rack.
•Bracket screws for attaching the brackets to the chassis.
Your device can be stored on a desktop, on a shelf, or in a rack. If you are bolting the device to the rack,
follow these guidelines.
Warning!
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special
precautions to ensure that the system remains stable.
•If the rack comes with stabilizing devices, install the stabilizers before mounting or servicing the unit in
the rack.
•If the rack is partially filled, load the rack from the bottom to the top with the heaviest component at the
bottom of the rack.
•If you plan to expand your system to include additional TippingPoint systems in the future, allow space
in the rack for additions. During the initial installation, keep in mind the weight distribution and stability
of the rack.
Rack-mounting the TPS 440T device
The TPS 440T device is a 1U device that you can install using a front mount or mid-mount in a two-post
rack, or front and rear mount in a four-post rack.
Note: Do not use a two-post mount in a four-post rack. For four-post racks, use a four-post mount.
Two-post rack mount
Describes how to mount a 1U TPS device in a two-post rack.
22Threat Protection System Hardware Specification and Installation Guide
Page 29
1. Align the two front rack-mounting brackets (shown in Figure 9 on page 23) with the 440T chassis
holes according to your front mount or mid-mount requirements.
2. Secure the brackets to the chassis using the flat-head screws (six on each side) that came with the kit.
Figure 9. 440T front-mount bracket and ear
3. Secure the rack-mounting brackets into the holes of the front rack post or mid-rack post with three
screws on each side (rack screws not included in the kit).
Use Figure 10 on page 23 as a guide for how the front rack-mounting brackets are attached to the
device and to the rack in a front-mount. Use Figure 11 on page 23 as a guide for how the front rackmounting brackets are attached to the device and to the rack in a mid-mount.
Figure 10. 440T chassis with front mounting in a two-post rack
Figure 11. 440T chassis with mid-mounting in a two-post rack
Threat Protection System Hardware Specification and Installation Guide23
Page 30
Four-post rack mount
Describes how to mount a 1U TPS device in a four-post rack.
1. After attaching the front rack-mounting brackets to the device as described in Two-post rack mount on
page 22, attach the two slide-bracket screws (provided in the kit) on each side of the chassis.
2. Using three rack screws (not included in the kit) on each side, attach either the short slide-bracket or the
long slide-bracket to the rear post of the rack, depending on which length is needed to secure the chassis
in the rack.
3. Slide the slide brackets mounted to the back posts of the rack onto the chassis.
4. Secure the front rack-mounting brackets into the holes of the front rack post with three rack screws (not
included) on each side.
Figure 12 on page 24 shows the device as it would appear in the rack with front and rear-mount
brackets attached.
Figure 12. 440T chassis in a four-post rack
24Threat Protection System Hardware Specification and Installation Guide
Page 31
Rack-mounting the TPS 2200T device
The TPS 2200T devices are 2U devices that you can install using a front mount or mid-mount in a two-post
rack, or front and rear mount in a four-post rack.
Two-post rack mount for 2U chassis
Describes how to mount a 2U TPS device in a two-post rack.
You can choose to install your chassis into a two-post rack using a front mount or a mid-mount.
1. Align the two front rack-mounting brackets (shown in Figure 13 on page 25) to the chassis holes
according to your front mount or mid-mount requirements.
2. Secure the brackets to the chassis using the flat-head screws (three on each side) that came with the kit.
Figure 13. 2200T model front-mount bracket and ear
Threat Protection System Hardware Specification and Installation Guide25
Page 32
3. Secure the rack-mounting ears into the holes of the front rack post with screws (two on each side, not
included).
Use Figure 14 on page 26 as a guide for how the front rack-mounting brackets are attached to the
appliance and to the rack in a front mount. Use Figure 15 on page 26 as a guide for how the front
rack-mounting brackets are attached to the appliance and to the rack in a mid-mount.
Figure 14. 2200T model with front mounting in a two-post rack
Figure 15. 2200T model with mid-mounting in a two-post rack
26Threat Protection System Hardware Specification and Installation Guide
Page 33
Four-post rack mount for 2U chassis
Describes how to mount a 2U TPS device in a four-post rack.
The 2200T models ship with a slide rail kit to mount the appliance to a four-post rack. Slide rail kits are also
available for order from TippingPoint. Refer to the instructions in the slide rail kit for information about
installing the slide rails.
1. Use Figure 16 on page 27 as a reference for how a 2U chassis is installed in a four-post rack with
slide rails.
Figure 16. 2200T chassis in a four-post rack
Threat Protection System Hardware Specification and Installation Guide27
Page 34
Connect the power supply
Describes how to get power to your device.
1. After you have bolted the device to the rack, attach the power supply AC connections.
2. To turn power on for the 440T device, flip the power switch on the back panel of the device.
3. To turn power on for the 22000T device, use the power button located on the front panel of the device.
Attach cables
During initial setup, use the management processor connection or the console port to access the setup
wizard.
Attach the Console port connection
Describes how to attach the console port connection.
1. Connect the RJ-45 null modem cable to the Console port on the front of the unit.
2. Connect the other end of your cable (standard-sized female DB-9 connector) to your VT100-compatible
terminal or your computer.
Use the following terminal settings for the Console port:
•Baud rate: 115.2 Kbps
•Character size: 8 bits
•Parity: None
•Stop Bits: One
•Flow Control: None
Attach the management processor connection
Describes how to attach the management processor connection.
1. Connect one end of the Category 5 Ethernet cable to the port labeled MGMT located on the front
panel.
2. Connect the other end of the Ethernet cable to your network. This enables remote management.
Attach network connections
Describes how to make network connections.
28Threat Protection System Hardware Specification and Installation Guide
Page 35
All ports on the TPS device are dynamic and do not require fixed cable assignments. When making your
network cable connections, keep track of which ports you select for which purpose.
1. Attach one or more network cables for the internal network. Make note of which front panel ports you
use.
2. Attach a network cable for the external (WAN) network. Make note of which front panel port you use.
3. Using the LSM or the command line interface, configure network interface types appropriate to the
surrounding network using the ports you selected.
For more information about device network configuration and connections, refer to the Local SecurityManager User Guide and the CLI Reference.
Check LEDs
When you connect power to the device, the system completes a series of component checks. It then displays
LEDs to show the status of each component. Refer to Chassis features on page 9 for more information about
the LEDs.
Run the setup wizard
After you have powered on, the setup wizard is displayed on your COM port terminal. The wizard prompts
you to perform basic configuration tasks and periodically input information. After you run the setup, you
can further configure your system using subsequent setup commands through the Command Line Interface
(CLI). See the CLI Reference for detailed command descriptions.
Threat Protection System Hardware Specification and Installation Guide29
Page 36
Connector and cable pinout specifications
This information provides connector and pinout information for the TPS device and contains the following
topics:
•RJ-45 (COM) console on page 30
•RJ-45 Ethernet connectors on page 31
•Pluggable transceivers on page 31
RJ-45 (COM) console
Describes the RJ-45 (COM) console specifications.
The following figure displays the RJ-45 connector and the following table shows the RJ-45 console
connector pinouts.
Figure 17. RJ-45 connector
Pin numberSignal name
1Request to Send (RTS)
2Data Terminal Ready (DTR)
3Transmit Data (TxD)
4Ground (GND)
5Ground (GND)
6Receive Data (RxD)
7Data Set Ready (DSR)
30Threat Protection System Hardware Specification and Installation Guide
Page 37
Pin numberSignal name
8Clear to Send (CTS)
RJ-45 Ethernet connectors
Provides pinout information for when your RJ-45 device is operating in 10Mbps/100Mbps mode.
Pin numberSignal name
1Transmit positive (Tx+)
2Transmit negative (Tx-)
3Receive positive (Rx+)
4Ground (GND)
5Ground (GND)
6Receive negative (Rx-)
7Ground (GND)
8Ground (GND)
Pluggable transceivers
The 2200T device supports the following SFP and SFP+ pluggable transceivers:
•1G SFP RJ45 T (Copper SFP)
•1G SFP LC LX 10km 1310nm XCVR
•1G SFP LC SX 550m 850nm XCVR
•10G SFP+ LC SR
Threat Protection System Hardware Specification and Installation Guide31
Page 38
•10G SFP+ LC LR
Note: Only optical transceiver modules (including SFP and SFP+) available from TippingPoint have been
validated to achieve optimal performance with TippingPoint products. Other vendor devices are not
supported. Using other vendor devices could be detrimental to proper operation of the TippingPoint
system.
The following table details the information for SFP and SFP+ transceivers.
Fiber InputSignal
Left sideTransmit
Right sideReceive
32Threat Protection System Hardware Specification and Installation Guide
Page 39
Power supply and fan modules
This topic provides information for using the power supply modules and fans. The following subjects are
discussed.
•The 2200T AC power supply on page 33
•The 2200T DC power supply on page 34
•TPS fans on page 36
Warning!
Note: The 2200T device has removable fans and power supplies. The power supplies are hot-swappable. It
has no other serviceable parts inside. There are no hot-swappable or serviceable parts inside the 440T
device.
This product might have more than one power supply source. All power sources must be
removed to de-energize the unit.
The 2200T AC power supply
The 2200T device includes two power supply modules. The modules are hot-pluggable, redundant, and
current-sharing, and the appliance can run with one active module.
Figure 18. 2200T AC power supply
1. Removal Latch
2. Handle
Threat Protection System Hardware Specification and Installation Guide33
Page 40
3. Status LED
4. AC male power input
The Status LED is green when the module is powered and running normally.
Connect the AC power supply
Describes how to connect the power supply to your device.
When the AC power supply has been securely placed in the device, use the following procedure to connect
power to the AC power supply:
1. Locate the male power input on the back of the chassis.
2. Plug one end of a standard female power plug into the power input.
3. Plug the other end into an AC outlet, power strip, or UPS.
For the power requirements for the 440T device, see Technical specifications on page 12. For the power
requirements for the 2200T device, see Technical specifications on page 19.
The TPS device returns to its previous power-on state in the event of a power interruption. If power
was on when the interruption occurred, the device automatically powers back on when the power is
reconnected; if power was off, the device stays off when the power is reconnected. If necessary, power
on the device with the button on the front of the chassis.
The 2200T DC power supply
The 2200T device is NEBS compliant and can accept a combination of AC and DC power supply units.
Consult your TippingPoint account contact for more information on obtaining DC power supplies.
Warning!
Connect the DC power supply
Warning!
Caution:
The power supply LED is green when the module is powered and running normally.
Do not attempt to install a DC power supply into a 440T device. The 440T device does not
contain the grounding capability for safe installation of a DC power supply. Bodily harm and
damage to the system could result.
When installing the product, always make the ground connection before applying power to
the unit. This equipment needs to be grounded to an external ground connection. Use a green
and yellow 12 AWG ground wire to connect the host to earth ground during normal use.
Disconnect the ground connection only when the unit is completely powered down.
Do not attach a ground wire to the ground screw on the DC power supply module. Attach
the ground wire to the 2200T chassis DC grounding screw holes (0.63-inch hole spacing) with
#10 screws. The DC grounding screw holes are located in the rear of the chassis.
34Threat Protection System Hardware Specification and Installation Guide
Page 41
When the DC power supply has been securely placed in the device, use the following procedure to connect
power to the DC power supply.
1. Locate the ground screw on the back of the chassis.
Refer to the following figure for the location.
Figure 19. DC grounding screw holes
2. Attach a 12 AWG ground wire to the chassis ground strap mounting.
The wire should be crimped with a ring lug.
3. Locate the power input terminal block on the back of the module.
4. Attach the 12 AWG DC power wires to the power input terminal block labeled -48V and RTN.
The power wires should be crimped with lug spades to ensure a secure connection.
5. Connect the other side of the power cable to the SELV power source.
The power source should meet the following requirements:
•Voltage: -40 to -60 V
•24 - 16 Amps
•SELV
6. Depending on the BIOS settings and the state the device was in when the power was unplugged, the
device might or might not turn on automatically when power is reapplied. If necessary, power on the
device with the button on the front of the chassis.
Threat Protection System Hardware Specification and Installation Guide35
Page 42
TPS fans
The 440T device includes five cooling fans (two of them are internal). The fans are not redundant or hotpluggable. If a failure to a fan module occurs, you must replace the entire device.
The 2200T device includes three cooling fans. The fans for the 2200T device are redundant but not hotpluggable. An individual fan can be replaced but not without first powering down the device.
The TPS Spare Fan (5066-3329) is a replacement unit and can only be used with TPS 2200T devices or
NGFW S3000/S8000 Series appliances.
Figure 20. 2200T fan unit
1. Attachment Screws
2. Fan Assembly
When a fan module fails or its RPM rate falls below a certain threshold, the system generates a warning or
critical alarm message in its logs.
You can check a fan’s performance using:
•The Local Security Manager (LSM) graphical user interface: System Health > Monitor > Fan Speed
•The command line interface (CLI): show health fan
Replace the fan
Describes how to replace the fan.
36Threat Protection System Hardware Specification and Installation Guide
Page 43
After you have identified the faulty fan assembly, follow this procedure to replace the fan:
1. Power down the system.
2. Remove the top two attachment screws and lift the fan unit up slightly and partially pull it from its slot.
3. Reach in the slot and disconnect the fan's cable connector from the main board.
4. Remove the entire fan assembly from its slot.
5. Set the faulty fan aside.
6. Remove the new fan assembly from the packaging.
7. Plug the new fan's cable into the main board.
8. Align the new fan assembly slightly higher than its open slot.
9. Slide the unit down until it is seated.
10. Tighten the two attachment screws securely.
Threat Protection System Hardware Specification and Installation Guide37
Page 44
Installing the power cord retention bracket
The power cord retention bracket lets you manage the placement of power cords for minimal obtrusiveness.
The following subjects are discussed:
•Power cord retention bracket on page 38
•Installing and using the bracket on page 38
•Removing the bracket on page 39
Power cord retention bracket
Provides a description and image of the power cord retention bracket.
The power cord retention bracket helps reduce strain on the power cord and power supply outlets.
Figure 21. Power Cord retention bracket
Installing and using the bracket
The following figure shows a 2200T device with the power cord retention bracket installed:
Figure 22. 2200T TPS device- back panel
38Threat Protection System Hardware Specification and Installation Guide
Page 45
Follow the procedures in this section to install and use the power cord retention bracket and the cable
management bracket.
Installing the bracket
Use the following procedure to install the power cord retention bracket:
1. Orient the bracket against the back surface of the chassis.
2. Slide the bracket over the two shoulder rivets on the back of the chassis.
The spring-loaded plunger in the center of the bracket slides into place.
Using the power cord retention bracket
Follow this procedure to attach the power cord to the retention bracket:
1. Fold the power cable and slide it into the slot.
2. Push the folded cable into the slot until the cable loop goes past the sheet metal tabs.
3. Secure the folded cable loop under the sheet metal tabs and attach the power cable to the power supply.
Removing the bracket
If you need to remove one of the brackets, pull the spring-loaded plunger in the middle of the bracket and
slide the bracket up and off the shoulder rivets.
Threat Protection System Hardware Specification and Installation Guide39
Page 46
Using the external CFast storage card
This information describes the external storage card and provides the following topics:
•About the external CFast storage card on page 40
•CFast card commands on page 40
About the external CFast storage card
The TPS device comes with a pre-formatted external CFast storage card.
Note: Only CFast cards available from TippingPoint have been validated to achieve optimal performance
with TippingPoint products. Other vendor cards are not supported. Using other vendor cards could
be detrimental to proper operation of the TippingPoint system.
The external CFast card is an 8GB storage card used to store traffic logs, snapshots, and other system data.
Caution:
You can replace the CFast card when the system is operating. Before you remove the card, use the command
line interface (CLI) to first unmount the card. For the appropriate unmount command, consult CFast card
commands on page 40.
After you successfully unmount the previous storage card, you can insert a new card into the CFast slot.
Referencing CFast card commands on page 40, issue the appropriate mounting and preparation commands
in the CLI.
When you manually mount and format a CFast card, the card will mount automatically when the device
boots.
Failure to properly remove the TippingPoint CFast card can result in disk corruption and a
system error.
CFast card commands
Lists the commands used to manage the external storage card in the CLI.
Refer to the CLI Reference for detailed documentation of these commands.
CommandDescription
user-disk formatFormats a card. Any existing data on the card will be erased.
40Threat Protection System Hardware Specification and Installation Guide
Page 47
CommandDescription
Note: Only cards that are mounted and formatted manually by
the user will be mounted automatically by the device when
it boots. However, after the initial install, any card still
present in the device during subsequent installs will also be
mounted automatically.
user-disk mountManually mounts the inserted card.
Note: Only cards that are mounted and formatted manually by
the user will be mounted automatically by the device when
it boots. However, after the initial install, any card still
present in the device during subsequent installs will also be
mounted automatically.
user-disk unmountUnmounts the card so that the user can remove it.
user-disk encryption
enable
Encrypts the card if the system master-key has been set. Changing
the encryption status reformats the card and erases all data on the
card.
Note: Master-key and encryption controls can also be configured
using System > Settings > Data Security in the LSM.
For more information, refer to the Local Security ManagerUser Guide.
user-disk encryption
disable
Disables encryption of the card if the system master-key has been
set. Changing the encryption status reformats the card and erases
all data on the card.
Note: Master-key and encryption controls can also be configured
using System > Settings > Data Security in the LSM.
For more information, refer to the Local Security ManagerUser Guide.
show user-diskShows properties of the card, including operation status and
capacity.
Threat Protection System Hardware Specification and Installation Guide41
Page 48
CommandDescription
master-key setEncrypts the external CFast card and the system keystore using
the system master-key. You are prompted to enter a masterkey that is between 9 and 32 characters in length, contains a
combination of numbers and uppercase and lowercase letters, and
that has at least one special character (for example, !@#).
Note: Master-key and encryption controls can also be configured
using System > Settings > Data Security in the LSM.
For more information, refer to the Local Security ManagerUser Guide.
42Threat Protection System Hardware Specification and Installation Guide