Trek Model 615 Series
High-Voltage AC/DC Generators
The Trek Model 615A-1 and the Model 615-3 are precision high-
voltage AC/DC generators that can be used in constant voltage,
constant current or external amplifier mode. They are specifically
designed to simultaneously provide the AC and DC operating
potentials required to operate/control an electrostatic charger
roller and offer features such as four-quadrant output, high
rejection of load current noise and three wave output shapes.
The Model 615-10 has the same features with a 20 kV peak-topeak capability. Please refer to the separate 615-10 data sheet
for more information.
Key Specifications
! Output Voltage Range:
! Output Current Range: peak current capability for 50 µs
! Slew Rate: Greater than 1000 V/
!
Large Signal Bandwidth (1% distortion): DC to greater than 15 kHz
!
DC Voltage Gain: Fixed at 1000 V/V
0 to ±7.5 kV DC or peak AC
0 to ±50 mA DC with a 0 to ±160 mA
µs
Typical Applications Include
! Dielectric charge material characterization
Polymer and ceramic corona charging
!
Piezoelectric driving and control
!
Features and Benefits
Monitor and control photoreceptor charging current with very high accuracy
!
! Four-quadrant output for driving capacitive loads
! Short-circuit protected for equipment protection
Operator-selectable sine, square or triangle wave output shape
!
NIST-traceable Certificate of Calibration provided with each unit
!
compliant
!
TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK
716-438-7555 • 716-201-1804 (fax) • www.trekinc.com • sales@trekinc.com
Graduated 1-turn panel potentiometer is used
to optimize the AC response for various load
parameters
Switch selectable for either limit or trip.
Graduated 1-turn panel potentiometer is used
to adjust limit or trip level from 0 to ±50 mA
Illuminates and a TTL low is provided when unit
fails to produce required HV output such as
during current limit or short circuit conditions
Illuminates and a TTL low is provided when the
high-voltage output is disabled due to the
output current exceeding the current trip level,
the detection of a high-voltage supply fault or
the removal of the top cover
A BNC provides a TTL low when the PD05034
is out of regulation for greater than 100 ms
279 mm H x 482 mm W 654 mm D
(11” H x 19” W x 25.75” D)
Alden High Voltage Connector
Amplifier Input, Voltage Monitor, Current Monitor,
Remote High Voltage ON/OFF, Out of Regulation
Status, Fault/Trip Status
0°C to 40°C (32°F to 104°F)
To 2000 meters (6561.68 ft.)
Factory Set for one of two ranges:
104 to 127 V AC or 180 to 250 V AC,
either at 48 to 63 Hz
Standard 3-prong AC line connector
PN: N5011; s
destination
elected per geographic
Model 608RA (with EIA hole spacing)
Model 608RAJ (with JIS hole spacing)
615 Series Abridged Specifications
0 to ±7.5 kV DC or peak AC
0 to ±50 mA DC with a peak current capability
of ±160 for 60 µs
0 to ±7.5 V DC or peak AC
Better than 0.1% of full scale
DC Offset Voltage
Slew Rate
(10% to 90%, typical)
Large Signal
Bandwidth
(1% distortion)
DC to greater than 15 kHz
Small Signal
Bandwidth (-3dB)
DC to greater than 75 kHz
Settling Time (to 1%)
Less than 50 µs for a 0 to 7.5 kV step
Less than 50 ppm/hr, noncumulative
1/1000th of the high-voltage output
Better than 0.1% of full scale
Better than 1% of full scale
Individual push-button switch
Remote (TTL
compatible input)
TTL high (or open) turns off high-voltage output.
TTL low turns on high-voltage output.
*Measured using the true rms feature of the HP Model 34401A digital multimeter
Copyright ã 2012 TREK, INC. All specifications are subject to change. 1235DEC
Measurement and Power Solutions
TM
www.trekinc.com