Trek 609E-6 User Manual

Trek Model 609E-6
High-Voltage Power Amplifier
The Model 609E-6 is a DC-stable, high-voltage power amplifier used in industrial and research applications. It features an all-
solid-state design for high slew rate, wide bandwidth and low­noise operation. The four-quadrant, active output stage sinks or sources current into reactive or resistive loads throughout the
output voltage range. This type of output is essential to achieve
an accurate output response and high slew rate demanded by a variety of loads such as highly capacitive or reactive loads. It is configured as a non-inverting amplifier, an inverting amplifier or as a differential amplifier. Different input configurations can be wired into the unit.
Key Specifications
Output Voltage Range:
! 0 to ±4 kV DC or peak AC
Output Current Range:
!
Slew Rate: Greater than V/
! !
Large Signal Bandwidth (1% distortion): DC to greater than 10 kHz
!
DC Voltage Gain: 1000 V/V
0 to ±20 mA DC or peak AC
150 µs
Typical Applications Include
! AC or DC biasing !
Atmospheric plasma
!
Dielectric barrier discharge
!
Electroactive polymers (EAP)
!
Electrophoresis, electrophotography
!
Electrorheological fluids
!
Electrostatic deflection
! Electro-optic modulation ! Ferroelectric material characterization ! Ion beam steering ! Mass spectrometers ! Material poling and particle accelerators
Features and Benefits
!
Four-quadrant output for driving capacitive loads
!
Closed loop system for high accuracy
!
Short-circuit protected for equipment protection
!
DC-stable for programmable supply applications
!
Low output noise for ultra-accurate outputs
!
NIST-traceable Certificate of Calibration provided with each unit compliant
!
TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK
716-438-7555 • 716-201-1804 (fax) • www.trekinc.com • sales@trekinc.com
Features
High Voltage On/Off
Local
Individual push-button switches
Remote
TTL high turns OFF the high voltage; TTL low turns on the high voltage
Dynamics Adjustments
Graduated 1-turn potentiometer used to optimize the AC response for various load parameters
Current Limit/Trip
Switch selectable for limit or trip. Graduated 1­turn potentiometer adjusts from 0 to 20 mA
Out of Regulation
LED illuminates and BNC provides a TTL low when Model 609E-6 fails to produce HV output such as during a current limit
Trip Status
LED illuminates and BNC provides a TTL low when HV is disabled due to the output current exceeding the current trip level, a high voltage fault is detected or the top cover is removed
Mechanical
Dimensions
140 mm H x 432 mm W x 439 mm D (5.5” H x 17” W x 17.25” D)
Weight
13.2 kg (29 lb)
HV Connector
Alden High Voltage Connector
BNC Connectors
Voltage monitor, current monitor, remote HV ON/OFF, out of regulation, fault/trip status
Amplifier Input
Amphenol panel mount
Operating Conditions
Temperature
0°C to 40°C (32°F to 104°F)
Relative Humidity
To 85%, noncondensing
Altitude
To 2000 meters (6561.68 ft.)
Electrical
Line Voltage
Factory Set for one of two ranges: 90 to 127 V AC or 180 to 250 V AC, either at 48 to 63 Hz
Power Consumption
220 VA, maximum
Supplied Accessories
Operator’s Manual
PN: 23163 HV Output Cable
PN: 43406
Input Cable Connector Assembly
PN: 43418
Line Cord (90 V to 127 V operation)
PN: N5011 Line Cord 230 V AC
Contact factory
Optional Accessories
HV Output Cable
PN: 43406
19” Rack Mount Kit
Model 607RA (with EIA hole spacing) Model 607RAJ (with JIS hole spacing)
Model 609E-6 Specifications
Performance
Output Voltage
0 to ±4 kV DC or peak AC
Output Current
0 to ±20 mA DC or peak AC
Input Voltage Range
0 to ±4 V DC or peak AC
Input Impedance
Noninverting
25 kW, nominal
Inverting
50 kW, nominal
Differential
50 kW, nominal
DC Voltage Gain
1000 V/V
Noninverting (V )
A
Configuration
1000 V/V
Inverting (V )
B
Configuration
-1000 V/V
Differential
Configuration
Function of the difference between two input signals. Represented by the equation: V = 1000 (V - V )
OUT A B
DC Voltage Gain Accuracy
Better than 0.1% of full scale DC Offset Voltage
Less than ±2 V
Output Noise
Less than 50 mV rms*
Slew Rate (10% to 90%, typical)
Greater than 30 V/µs Settling Time (to 1%)
Less than 150 µs for a 0-4 kV step
Large Signal Bandwidth (1% distortion)
DC to greater 6 kHz Small Signal Bandwidth (-3dB)
DC to greater than 35 kHz Stability
Drift with Time
Less than 100 ppm/hr, noncumulative
Drift with Temp
Less than 200 ppm/°C
Voltage Monitor
Ratio
1/1000th of the high-voltage output signal
DC Accuracy
Better than 0.1% of full scale
DC Offset Voltage
Less than ±2.5 mV
Output Noise
Less than 2 mV rms*
Output Impedance
47 W
Current Monitor
Ratio
0.5 V/mA
DC Accuracy
Better than 0.5% of full scale
Offset Voltage
Less than ±5 mV
Output Noise
Less than 10 mV*
Output Impedance
47 W
*Measured using the true rms feature of the HP Model 34401A digital multimeter
Copyright ã 2013 TREK, INC. All specifications are subject to change. 1343/JRB
Measurement and Power Solutions
www.tre kinc.com
TM
Loading...