Trek 603 User Manual

Trek Model 603
Piezo Driver/Power Amplifier
The Trek Model 603 is a high-voltage DC power amplifier/piezo driver designed to provide precise control of output voltages in bipolar or unipolar ranges that are customer specified within a range of available settings. The instrument achieves the accurate output responses and high slew rates demanded by reactive loads by utilizing a four-quadrant active output stage that sinks or sources current into reactive or resistive loads.
The Model 603 is configured as a non-inverting amplifier. An inver tin g con figur atio n is o ptio nally availab le. Both configurations are available in single or dual channel packaging. They are operable on a bench top or in a 19-in rack.
Key Specifications
! Available Voltage Ranges:
! Output Current Range: peak AC for less than 1 ms
! Slew Rate: Greater than 100 V/ !
Large Signal Bandwidth (5% distortion): DC to greater than 150 kHz DC Voltage Gain: 50 V/V or 25 V/V
!
0 to ±125 V DC or peak AC or 0 to -250 V DC or peak AC or 0 to +250 V DC or peak AC 0 to ±40 mA DC or ±80 mA
µs
Typical Applications Include
! Driving piezoelectric actuators ! Modulating electrooptics ! Electrostatically controlling ion beams ! Providing remote ON/OFF capabilities for
automated or computer controlled systems
Features and Benefits
Four-quadrant output for driving capacitive loads
!
Up to two independent amplifier channels in one enclosure
!
Short-circuit protected for equipment protection
! ! Reprogrammable factory-set output configurations ! All solid-state design for maintenance free operation
Low output noise for ultra-accurate outputs
!
NIST-traceable Certificate of Calibration provided with each unit
!
compliant
!
TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK
716-438-7555 • 716-201-1804 (fax) • www.trekinc.com • sales@trekinc.com
Features (cont.)
Digital Enable
An input providing a connection for a TTL compatible signal to turn on/off the HV output
Load Range Switch
Slide switch to select high or low capacitive loads (more than 150 pF or less than 150 pF)
Dynamic Adjustment
Graduated 1-turn panel potentiometer is used to optimize the AC response for various load parameters.
Mechanical
Dimensions Single Channel
Instrument
Double Channel
Instrument
222.3 mm H x 108 mm W 381 mm D (8.75” H x 4.25” W x 15” D)
433.8 mm H x 108 mm W 381 mm D (17” H x 4.25” W x 15” D)
Weight Single Channel
Instrument
Double Channel
Instrument
4.3 kg (9.4 lb)
8.6 (18.8 lb) HV Connector
SHV High Voltage Connector
BNC Connectors
Power Switch, Amplifier Input, Voltage Monitor, Current Monitor, High Voltage ON/OFF, Digital Enable
Operating Conditions
Temperature
0°C to 40°C (32°F to 104°F)
Relative Humidity
To 85%, noncondensing
Altitude
To 2000 meters (6561.68 ft.)
Electrical
Line Voltage
Factory Set for one of two ranges: 90 to 127 V AC or 180 to 250 V AC, either at 48 to 63 Hz
AC Line Receptacle
Standard 3-prong with integral fuse holder
Power Consumption
125 VA, maximum
HV Cable
2 m, 66 pF per foot
Supplied Accessories
Operators’ Manual
PN: 23166
HV Output Cable
PN: 43874
Line Cord Spare Fuses
N5002 Selected per geographic destination
Optional Accessories
19” Rack Mount Kit Half-Rack Mount Kit Dual Instrument Rack Mount Kit
Model 603RA Model 604RA (3 ½” Buckeye) Model 603RA-2
Model 603 Specifications
Performance
Available Output Voltage Ranges
0 to ±125 V DC or peak AC 0 to -250 V DC or peak AC 0 to +250 V DC or peak AC
Output Current
±40 mA DC ±80 mA peak AC, for less than 1 ms
DC Voltage Gain
50 V/V (a gain of 25 V/V is available)
DC Voltage Gain Accuracy
Better than 0.1% of full scale DC Offset Voltage
Less than ±500 mV
Output Noise*
Less than 20 mV rms
Slew Rate (10% to 90%, typical)
Greater than 100 V/µs
Large Signal Bandwidth (5% distortion)
DC to greater than 150 kHz
Settling Time to 1%
Less than 5 µs for a 100 V step
Stability
Drift with Time
Less than 100 ppm/hr, noncumulative
Drift with
Temperature
Less than 25 ppm/°C
Amplifier Input
Input Voltage Range
0 to ±10 V DC or peak AC, noninverting Input Impedance
10 W, nominal
Voltage Monitor
Ratio
1/25th of the high voltage output
DC Accuracy
Better than 0.1% of full scale
AC Accuracy
Calibrated using a Ross Model VD30-4.1-BD­KC-ALU high voltage divider
DC Offset Voltage
Less than 5 mV
Output Noise
Less than 5 mV rms*
Output Impedance
0.1 W
Current Monitor
Ratio
0.1 V/mA
DC Accuracy
Greater than 1% of full scale
Offset Voltage
Less than 10 mV
Output Noise
Less than 10 mV rms*
Output Impedance
0.1 W
Features
Output Voltage Configuration
Factory set for 0 to ±125 VDC or peak AC. Other ranges available.
*Measured using the true rms feature of the Hewlett Packard 34401A digital multimeter
Measurement and Power Solutions
Copyright ã 2012 TREK, INC. All specifications are subject to change. 1230/DEC
TM