The Model 5/80 is a DC-stable, high-voltage power amplifier used in industrial and research applications. It features an all-
solid-state design for high slew rate, wide bandwidth and low­noise operation. The four-quadrant, active output stage sinks or sources current into reactive or resistive loads throughout the
output voltage range. This type of output is essential to achieve
an accurate output response and high slew rate demanded by a variety of loads such as highly capacitive or reactive loads. It is configured as a non-inverting amplifier.
Key Specifications
Output Voltage Range:
!
Output Current Range:
!
Slew Rate: Greater than V/
!
Large Signal Bandwidth (-3 dB): DC to greater than 60 kHz
!
DC Voltage Gain: Fixed at 1000 V/V
!
0 to ±5 kV DC or peak AC 0 to ±80 mA DC or peak AC
1000 µs
Typical Applications Include
! AC or DC biasing !
Atmospheric plasma
!
Dielectric barrier discharge
!
Electroactive polymers (EAP)
!
Electrophoresis, electrophotography
!
Electrorheological fluids
!
Electrostatic deflection
! Electro-optic modulation ! Ferroelectric material characterization ! Ion beam steering ! Mass spectrometers ! Material poling and particle accelerators
Features and Benefits
Four-quadrant output for driving capacitive loads
!
Closed loop system for high accuracy
!
Short-circuit protected for equipment protection
!
All solid-state design for maintenance free operation
!
DC-stable for programmable supply applications
!
Low output noise for ultra-accurate outputs
!
NIST-traceable Certificate of Calibration provided with each unit
!
compliant
!
TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK
(fax) • www.trekinc.com • sales@trekinc.com 716-438-7555 • 716-201-1804
Features (cont.)
Remote
TTL compatible input. TTL high (or open) turns off high-voltage output. TTL low turns on high­voltage output
Dynamic Adjustment
Graduated 1-turn panel potentiometer is used to optimize the AC response for various load parameters.
Current Limit/Trip
Switch selectable for either limit or trip. A graduated 1-turn panel potentiometer is used to adjust limit or trip level from 0 to ±80 mA
Out of Regulation
Indicator illuminates and BNC provides TTL low when the high-voltage output fails to produce required HV output (e.g. during a current limit)
Trip Status
Illuminates and a TTL low is provided when the high-voltage output is disabled due to the output current exceeding the trip level, the detection of a high-voltage supply fault for the removal of the top cover
Fault Status
TTL low is provided when out of regulation for greater than 500 ms.
Mechanical
Dimensions
279 mm H x 482 mm W x 654 mm D (11” H x 19” W x 25.75” D)
Weight
24 kg (55 lb)
HV Connector
Alden High Voltage Connector
BNC Connectors
Amplifier Input, Voltage Monitor, Current Monitor, Remote High Voltage ON/OFF, Out of Regulation Status, Fault/Trip Status
Operating Conditions
Temperature
0°C to 40°C (32°F to 104°F)
Relative Humidity
To 85%, noncondensing
Altitude
To 2000 meters (6561.68 ft.)
Electrical
Line Voltage
Factory Set for one of two ranges: 104 to 127 V AC or 180 to 250 V AC, either at 48 to 63 Hz
AC Line Receptacle
Standard three-prong AC line connector
Power Consumption
1000 VA, maximum
Supplied Accessories
Operators’ Manual
PN: 23189
HV Output Cable
PN: 43406
Line Cord, Spare Fuses
PN: N5011. destination
Selected per geographic
Optional Accessories
HV Output Cable
PN: 43421 (5m); 43422 (10 m); 43423 (20 m)
19” Rack Mount Kit
Model: 608RA (with EIA hole spacing) Model: 608RAJ (with JIS hole spacing)
Model 5/80 Specifications
Performance
Output Voltage Range
0 to ±5 kV DC or peak AC
Output Current Range
0 to ±80 mA DC or peak AC Input Voltage Range
0 to ±5 V DC or peak AC
Input Impedance
10 kW, nominal
DC Voltage Gain
1000 V/V
DC Voltage Gain Accuracy
Better than 0.1% of full scale DC Offset Voltage
Less than ±2 V
Output Noise
Less than 1.0 V rms*
Slew Rate (10% to 90%, typical)
Greater than 1000 V/µs
Large Signal Bandwidth (-3 dB)
DC to greater than 60 kHz
Large Signal Bandwidth (3% distortion)
DC to greater 50 kHz Small Signal Bandwidth (-3dB)
DC to greater than 75 kHz Settling Time
Less than 50 µs for a 0 to 5 kV step
Stability
Drift with Time
Less than 50 ppm/hr, noncumulative
Drift with Temp
Less than 200 ppm/°C
Voltage Monitor
Ratio
1/1000th of the high-voltage output signal
DC Accuracy
Better than 0.1% of full scale
DC Offset Voltage
Less than ±2 mV
Output Noise
Less than 10 mV rms*
Output Impedance
47 W
Current Monitor
Ratio
0.1 V/mA
DC Accuracy
Better than 1% of full scale
Offset Voltage
Less than ±10 mV
Output Noise
Less than 30 mV rms*
Bandwidth (-3dB)
DC to greater than 10 kHz
Output Impedance
47 W