Trek Model 2220
Piezo Driver/Power Amplifier
Trek’s Model 2220 is one of several models within our 2200series of high-voltage 40 W amplifiers. Provided at an
attractive price and offering high performance, the unit
incorporates DC stability, wide bandwidth and well
regulated/controlled AC output signals. It also features full
four-quadrant class AB all-solid-state output stages, DC
offset adjustment with front panel metering, and autorecovery shutdown to protect the output from being
overpowered. The instrument stage sinks or sources current
into reactive or resistive loads throughout the output voltage
range making it ideal to achieve the accurate output
response and high slew rates demanded by reactive loads.
Key Specifications
!
Output Voltage Range:
!
Output Current Range: peak AC for 5 ms minimum
Slew Rate: 100 V/
!
Large Signal Bandwidth (-3 dB): DC to greater than 7.5 kHz (minimum trip off frequency)
!
Small Signal Bandwidth(-3 dB): DC to greater than 50 kHz
!
DC Voltage Gain: 200 V/V
!
0 to ±2 kV DC or peak AC
0 to ±10 mA DC or ±20 mA
µs, typical
Typical Applications Include
! Piezoelectric driving/control
Electro-optic
!
MEMS
!
Many areas of research
!
Features and Benefits
!
Four-quadrant output for driving capacitive loads
!
2-year warranty
DC offset adjustment with front panel metering
!
Auto-recovery shutdown protects the output from being overpowered
!
Low output noise for ultra-accurate outputs
!
All solid-state output stages
!
! RoHS compliant
! HALT Tested
! NIST-traceable Certificate of Calibration provided with each unit
! compliant
TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK
(fax) • www.trekinc.com • sales@trekinc.com 716-438-7555 • 716-201-1804
A BNC connection for a TTL compatible signal
to turn ON/OFF the high voltage output is
provided. TTL high (or open) turns off the HV
output; TTL low turns on the HV output.
A graduated 1-turn panel potentiometer is used
to optimize the AC response for various load
parameters.
Front panel red LED illuminates when the high
voltage is on.
85 mm H x 205 mm W 325 mm D
(3.3” H x 8.1” W x 12.8” D)
Amplifier Input, Voltage Monitor, Current Monitor,
Digital Enable
0°C to 40°C (32°F to 104°F)
To 2000 meters (6561.68 ft.)
90 to 265 V AC, at 50/60 Hz
24 V DC, regulated at 1.75A maximum
HV Output Connector
(SHV Mating
Connector)
The output cable supplied with this instrument uses a coaxial cable that
has 30.8 pF/ft of capacitance at 1 kHz nominal. This cable capacitance
must be factored in as a portion of the load and will reduce slew rates
and large signal bandwidth. In applications that require maximum
performance it is suggested that the supplied high voltage coaxial cable
be kept as short as possible to reduce capacitance. Another option is
to cut the coaxial cable short and add two break out leads (1 for shield
[ground] and 1 for the center conductor) for the connection to load.
Model 2220 Specifications
0 to ±10 mA DC or ±20 mA peak (for 5 ms
minimum)
Better than 0.5% of full scale
Offset Voltage
Slew Rate
(10% to 90%, typical)
Large Signal
Bandwidth (-3 dB)
DC to greater than 7.5 kHz
Small Signal
Bandwidth (-3dB)
DC to greater than 50 kHz
Settling Time to 1%
Less than 50 µs for 0 to 2 kV step
Internal Capacitance
(HV Output)
Limits internal power dissipation for protection
from overheating
Less than 300 ppm/hr, noncumulative
1/200th of the high voltage output
Better than 2% of full scale
*Measured using the true rms feature of the Hewlett Packard Model 34401A digital multimeter
Measurement and Power Solutions
Copyright © 2013 TREK, INC. All specifications are subject to change. 1317/JRB