Trek Model 2100HF
High-Frequency, High-Speed Amplifier
The Trek Model 2100 HF is a high-frequency, high-speed, wide
bandwidth amplifier for high power applications. It incorporates an
all-solid-state design for highly reliable low-noise operation, thus
achieving accurate output response and high slew rates, even in
highly capacitive loads. Full power frequency response of the
amplifier is essentially flat up to 2 MHz. No overshoot or instability
of the waveform occurs due to the amplifier’s unique dual
feedback feature.
Key Specifications
!
Output Voltage Range:
!
Output Current Range:
!
Slew Rate: 2 kV/
!
Large Signal Bandwidth (-3 dB): DC to greater than 2.6 MHz
!
Small Signal Bandwidth(-3 dB): DC to greater than 3 MHz
!
DC Voltage Gain: 50 V/V
0 to ±150 V DC or peak AC
0 to ±300 mA DC
µs, typical
Typical Applications Include
! Dielectric material characterization
!
Electro-optic modulation
!
Ion beam control
MEMS
!
Piezoelectric driving and control
!
Ultrasonics
!
Features and Benefits
Incorporates all-solid state design for highly reliable low-
!
noise operation
Achieves accurate output rates and high slew rates even in
!
highly capacitive loads
Full power frequency response is essentially flat up to 2 MHz
!
Dual feed-back feature ensures “no overshoot” or instability
!
of waveform
RoHS compliant
!
NIST-traceable Certificate of Compliance provided with
!
each unit shipped
! compliant
TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK
(fax) • www.trekinc.com • sales@trekinc.com 716-438-7555 • 716-201-1804
141 mm H x 213 mm W 336 mm D
(5.57” H x 8.38” W x 13.22” D)
90 to 127 V AC, at 48 to 63 Hz
180 to 250 V AC, at 48 to 63 Hz
Line Cord (104 to 127
V AC operation)
Fuse, 2 A, 250 V
Slow, 5 mm x 20 mm
Line Cord (207 to 250
V AC operation)
Line cord type determined by the geographical
destination of the unit
Fuse, 2 A, 250 V
Slow, 5 mm x 20 mm
Model 2100HF Specifications
0 to ±150 V DC or peak AC
0 to ±300 mA DC
Input Voltage Range
Large Signal
Bandwidth (-3 dB)
DC to greater than 2.6 MHz
Small Signal
Bandwidth (-3dB)
DC to greater than 3 MHz
Stability
Less than 6 mV/ minute, noncumulative
Less than 150 ns (input to output)
Copyright © 2012 TREK, INC. All specifications are subject to change. 1244/JRB