Key Specifications
! Output Voltage Range:
! Output Current Range: peak AC
! Slew Rate: Greater than 450 V/
!
Large Signal Bandwidth (-3 dB): DC to greater than 7.5 kHz
!
DC Voltage Gain: Fixed at 2000 V/V
0 to ±20 kV DC or peak AC
0 to ±20 mA DC or
µs
Typical Applications Include
! Electrostatic deflection
! Electrophoresis
! Electrorheological fluids
! Electro-optic modulation
! Material poling
! AC or DC biasing
! Ion beam steering
! Particle accelerators
! Mass spectrometers
! Material characterization
! Ferroelectrics
! Atmospheric plasma
! Dielectric barrier discharge
Features and Benefits
!
Four-quadrant output for driving capacitive loads
!
Closed loop system for high accuracy
!
Short-circuit protected for equipment protection
CE compliant for assured reliability
!
All solid-state design for maintenance free operation
!
DC-stable for programmable supply applications
!
Low output noise for ultra-accurate outputs
!
TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK
(fax) • www.trekinc.com • sales@trekinc.com 716-438-7555 • 716-201-1804
Graduated 1-turn panel potentiometer is used
to optimize the AC response for various load
parameters
Switch selectable for either limit or trip.
Graduated 1-turn panel potentiometer is used
to adjust limit or trip level from 0 to ±20 mA
Illuminates and a TTL low is provided when unit
fails to produce required HV output such as
during current limit or short circuit load
conditions
Illuminates and a TTL low is provided when the
high-voltage output is disabled due to the
output current exceeding the current trip level,
the detection of a high-voltage supply fault or
the removal of the top cover
A BNC provides a TTL low when the Model
20/20C is out of regulation for greater than
500 ms
279 mm H x 482 mm W 654 mm D
(11” H x 19” W x 25.75” D)
Caton High Voltage Connector
Amplifier Input, Voltage Monitor, Current Monitor,
Remote High Voltage ON/OFF, Out of Regulation
Status, Fault/Trip Status
0°C to 40°C (32°F to 104°F)
To 2000 meters (6561.68 ft.)
Factory Set for one of two ranges:
104 to 127 V AC or 180 to 250 V AC,
either at 48 to 63 Hz
Standard IEC 320 three-prong AC line
connector
PN: N5011; s
destination
elected per geographic
Model: 608RA (with EIA hole spacing)
Model: 608RAJ (with JIS hole spacing)
Model 20/20C Specifications
0 to ±20 kV DC or peak AC
0 to ±20 mA DC or peak AC
Input Voltage Range
Better than 0.1% of full scale
Slew Rate
(10% to 90%, typical)
Large Signal Bandwidth
(-3 dB)
DC to greater than 7.5 kHz
Large Signal Bandwidth
(1% distortion)
DC to greater than 3.75 kHz
Small Signal Bandwidth
(-3dB)
DC to greater than 20 kHz
Stability
Less than 50 ppm/hr, noncumulative
1/2000th of the high-voltage output
Better than 0.1% of full scale
Better than 1% of full scale
DC to greater than 10 kHz
Individual push-button switch
Remote (TTL
compatible input)
TTL high (or open) turns off high-voltage
output. TTL low turns on high-voltage
output.
*Measured using the true rms feature of the HP Model 34401A digital multimeter
Copyright ã 2013 TREK, INC. All specifications are subject to change. 1322/JRB