Trek 158A User Manual

The Model 158A may be ordered as a kit which includes all items listed below.
- Model 158A Charged Plate Monitor
- 150 mm x 150 mm (6” x 6”) Charged Plate
- 25 mm x 25 mm (1” x 1”) Charged Plate
- Walking Test Adaptor Assembly
- AC Adaptor, 24v / 1.7a / 2.1mm Plug
- USB Type A Male To USB Type B Male Cable 6ft
- Power Cord For AC Adaptor
- Custom Patch Cord, ST-BAN-PL9’,ST-BAN-PL
- Charged Plate Handle
- Mini-Tripod For Charged Plates
- Model 158A Custom Carry Case
Trek Model 158A
Charged Plate Monitor
The Trek Model 158A Charged Plate Monitor is the premier instrument to evaluate the performance of air ionization systems. It features a user-friendly large 7 inch screen that is active through either touch­screen control or corresponding function keys. The compact design supports superior data collection and data storage capability. The data is displayed in color and may be stored internally or can be easily transferred to a USB flash drive or other USB device. A charged-plate assembly is required and is sold separately (6 inch charged-plate shown).
Key Specifications
! Monitored Voltage Range: 0 to ±1100 V DC or peak AC ! Bandwidth (-3 dB): DC to 80 Hz ! Decay Mode Thresholds: Programmable from 1 to ±1000 V in 1 V increments
Typical Applications Include
! Performance evaluation of air ionization systems ! ESD Test Equipment ! ESD Audit Equipment ! Material Dissipation Testing ! Site Specific Contacting Voltage Measurement ! Static Charge Monitoring ! Voltage measurement of floor materials and footwear in combination
Features and Benefits
Touch screen or function key control
!
Long battery life
!
User-friendly compact design with superior data collection and storage capability
!
Unique color graphics chart display
!
PC memory card port for ample data storage and easy data transfer
!
Programmable start and stop voltage for (+) and (-) decay time ionizer tests
!
0.1 V plate voltage resolution
!
Compliance to IEC 61340-5-1 and ANSI/ESD STM3.1
!
NIST-traceable Certificate of Calibration provided with each unit
!
TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK
716-438-7555 • 716-201-1804 (fax) • www.trekinc.com • sales@trekinc.com
Model 158A Specifications
Performance
Monitored Voltage Range
0 to ±1100 V DC or peak AC
Bandwidth (-3 dB)
DC to 80 Hz
Zero Stability (referred to plate voltage)
Drift with Time (no incident
ion flow)
Less than 6 V/minute Drift with Temperature
Less than 10 mV/°C, noncumulative
Decay Mode Thresholds
Start Voltage
Programmable from 1 to ±1000 V in 1 V increments
Start Accuracy
Within ±1 V of programmed start voltage
Stop Voltage
Programmable from 0 to ±999 V in 1 V increments
Stop Accuracy
Within ±1 V of programmed start voltage or ±0.2 V if set less than or equal to 90 V
Decay Timer
Resolution
0.1 sec., from 0.1 sec. to 999.9 sec., resolution 0.1 sec
Voltage Monitor Output
Voltage Monitor Output
A BNC proving and low voltage replica of the plate voltage
Scale Factor
1/200th of the plate voltage
DC Accuracy
Better than 0.1% of full scale
DC Offset
Less than ±10 mV
Output Noise
Less than 10 mV rms*
Output Impedance
Less than 0.1 W
Features
LCD Color Display (with contrast adjustment). Navigate via touch-screen or function keys
7 inch LCD touch-screen displays graphical readouts, numeric data, informational data, programming parameters and retrieved data
Analysis Resolution
14 bits
Mode Select/Programming
Allows multiple operational and programming options. Can be preset to perform a number of automated tests and is available to store or retrieve previously defined test parameters. Test locations and results can be saved and retrieved for future reference.
Ion Collecting Plate (standard option)
Meets ANSI/ESD-STM3.1 requirements Power ON-OFF
A momentary push-button
Float Mode, (+) Decay Mode, or (-) Decay Mode
Performs float voltage and decay time EOS/ESD measurements utilizing parameters, guidelines, and standards set by the EOS/ESD Association
Features (cont.)
For (+) Decay and (-) Decay Modes
The charged-plate is charged to a voltage level above the programmed (+) or (-) start voltage value. The plate is allowed to decay toward zero due to the ion impingement on the plate. The time required for the plate to decay from the programed start voltage to the programed stop voltage is displayed on the timer.
For Float Mode
The charged-plate monitor is reset to 0 V ±0.5 V. The plate is allowed to “float” to a voltage level dictated by ion impingement on the plate.
USB Flash Drive USB Host
USB host port allows information to be saved, retrieved and exchanged.
Barcode Scanner (Optional)
A barcode scanner can be used to input ionizer serial numbers directly from the Model 158A
Electrical
Power Requirements
Internal NiMH battery or External
1.75 A, 2.1mm jack charger / eliminator
24V DC,
Battery Operating Time
Greater than six hours of continuous operation
Mechanical
Dimensions
53 mm H x 226 mm W x 187 mm D (2.1” H x 8.9” W x 7.4” D)
Weight
2.2 kg (4.9 lb)
Voltage Monitor Connector
BNC connector (3 meter length maximum) Ground Receptacle
Binding ground post
Cable from Instrument to Floating Plate
Coaxial type; diameter is 4.95 mm (0.195”); length is 3 meters (10 ft)
Operating Conditions
Temperature
5°C to 35°C (41°F to 95°F)
Relative Humidity
To 80%, non-condensing
Supplied Accessories
Operator’s Manual
AC Adapter (100 to 265 V AC)
PN: 24021
PN: F5058R
Ion Collecting Plates (order separately)
150 mm x 150 mm (6” x 6”) plate
17397
25 mm x 25 mm (1” x 1”) plate
17375
Optional Accessories
Charged Plate Tripod
PN: DK142
Walking Test Adapter
CN: 1K062
Barcode Scanner
PN: M1041R
INTRODUCTORY SPECIFICATIONS
*Measured using the true rms feature of the HP Model 34401A digital multimeter
Measurement and Power Solutions
Copyright ã 2013 TREK, INC. All specifications are subject to change. 1332/JRB