Trek 10-40A User Manual

Trek Model 10/40A
High-Voltage Power Amplifier
The Model 10/40A is a DC-stable, high-voltage power amplifier used in industrial and research applications. It
features an all-solid-state design for high slew rate, wide bandwidth and low-noise operation. The four-quadrant, active output stage sinks or sources current into reactive or resistive
loads throughout the output voltage range. This type of output is
essential to achieve an accurate output response and high slew rate demanded by a variety of loads such as highly capacitive or reactive loads. It is configured as a non-inverting amplifier.
Key Specifications
Output Voltage Range:
!
Output Current Range: peak AC
!
Slew Rate: Greater than 750 V/
!
Large Signal Bandwidth (-3 dB): DC to greater than 23 kHz, typical
!
DC Voltage Gain: 1000 V/V
!
0 to ±10 kV DC or peak AC 0 to ±40 mA DC or
µs
Typical Applications Include
! Electrostatic deflection ! Electrophoresis ! Electrorheological fluids ! Electro-optic modulation ! Material poling ! AC or DC biasing ! Ion beam steering ! Particle accelerators ! Mass spectrometers ! Material characterization ! Ferroelectrics ! Atmospheric plasma ! Dielectric barrier discharge
Features and Benefits
Four-quadrant output for driving capacitive loads
!
Closed loop system for high accuracy
!
Short-circuit protected for equipment protection
!
All solid-state design for maintenance free operation
!
DC-stable for programmable supply applications
!
Low output noise for ultra-accurate outputs
!
NIST-traceable Certificate of Calibration provided with each unit
!
compliant
!
TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK
(fax) • www.trekinc.com • sales@trekinc.com 716-438-7555 • 716-201-1804
Features (cont.)
Dynamic Adjustment
Graduated one-turn panel potentiometer is used to optimize the AC response for various load parameters
Current Limit/Trip
Switch selectable for either limit or trip. Graduated 1-turn panel potentiometer is used ti adjust the limit or trip level from 0 to ±40 mA
Out of Regulation Status
Illuminates and a TTL low is provided when unit fails to produce required HV output such as during a current limit
Trip Status
An amber indicator will illuminate and a BNC will provide a TTL low when the high-voltage output is disabled due to the activation of the current trip or the removal of the top cover
Fault Status
A BNC will provide a TTL low when the Model 10/40A is out of regulation for greater than 500 ms
Mechanical
Dimensions
279 mm H x 482 mm W 654 mm D (11” H x 19” W x 25.75” D)
Weight
24.9 kg (55 lb)
HV Connector
Alden High Voltage Connector
BNC Connectors
Amplifier Input, Voltage Monitor, Current Monitor, Remote High Voltage ON/OFF, Out of Regulation Status, Limit/Trip Status
Operating Conditions
Temperature
0°C to 40°C (32°F to 104°F)
Relative Humidity
To 85%, noncondensing
Altitude
To 2000 meters (6561.68 ft.)
Electrical
Line Voltage
Factory Set for one of two ranges: 104 to 127 V AC or 180 to 250 V AC, either at 48 to 63 Hz
AC Line Receptacle
Standard IEC 320 three-prong AC line connector
Power Consumption
1000 VA, maximum
Supplied Accessories
Operators’ Manual
PN: 23228
HV Output Cable
PN: 43463
Line Cord, Spare Fuses
PN: N5011. destination
Selected per geographic
Optional Accessories
HV Output Cable
PN: 43463
19” Rack Mount Kit
Model: 608RA (with EIA hole spacing) Model: 608RAJ (with JIS hole spacing)
Model 10/40A Specifications
Performance
Output Voltage Range
0 to ±10 kV DC or peak AC
Output Current Range
0 to ±40 mA DC or peak AC (must not exceed 40 mA rms, max)
Input Voltage Range
0 to ±10 V DC or peak AC
Input Impedance
25 kW, nominal
DC Voltage Gain
1000 V/V
DC Voltage Gain Accuracy
Better than 0.1% of full scale DC Offset Voltage
Less than ±2 V
Output Noise
Less than 5 V rms*
Slew Rate (10% to 90%, typical)
Greater than 750 V/µs
Small Signal Bandwidth (-3dB)
DC to greater than 25 kHz
Large Signal andwidth (-3 dB)
DC to greater than 23 kHz, typical
Large Signal Bandwidth (1% distortion)
DC to greater than 7.5 kHz, typical
Stability
Drift with Time
Less than 50 ppm/hr, noncumulative
Drift with Temp
Less than 100 ppm/°C
Voltage Monitor
Ratio
1/1000th of the high-voltage output signal
DC Accuracy
Better than 0.1% of full scale
DC Offset Voltage
Less than ±2 mV
Output Noise
Less than 10 mV rms*
Output Impedance
47 W
Current Monitor
Ratio
0.1 V/mA
DC Accuracy
Greater than 1% of full scale
Offset Voltage
Less than ±10 mV
Output Noise
Less than 30 mV rms*
Bandwidth (-3dB)
DC to greater than 5 kHz
Output Impedance
47 W
Features
High-Voltage On/Off
Local
Individual push-button switch
Remote (TTL
compatible input)
TTL high (or open) turns off high-voltage output. TTL low turns on high-voltage output
*Measured using the true rms feature of the HP Model 34401A digital multimeter