Traxon Allegro Linear AC Series, Allegro Linear AC RGB, Allegro Linear AC RGBW, Allegro Linear AC SW, Allegro Linear AC DW Installation Manual

Allegro Linear AC
INSTALLATION GUIDE
V1.0
Cover:
Allegro Linear AC RGB
Allegro Linear AC RGBW
Allegro Linear AC DW
Allegro Linear AC SW (DMX)
CONTENT
SAFETY AND OPERATION 3
1. INTRODUCTION 4
2. INSTALLATION 8
3. SYSTEM CONFIGURATION 13
4. CARE AND MAINTENANCE 15
5. TECHNICAL SPECIFICATION 16
6. TROUBLESHOOTING 18
7. WARRANTY STATEMENT 18
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 12/19 V1.0 P. 2 of 19
SAFETY AND OPERATION
Please read through Safety and Operation before start of the installation.
1. CAUTION - Unplug the power supply from the mains power before connecting any cables as this can damage the products.
2. CAUTION - Avoid looking directly into the LED light source at close range for your own safety.
3. Persons installing this product should make sure:
a. The installation complies with all applicable codes, state and local laws, ordinances,
standards and safety regulations.
b. The installation environment is carefully studied and suitable surge protection
measure(s) is taken.
c. He or she is qualified for the handling of electrical equipment.
4. Do not attempt to install or use the product until installation instructions and safety labels are fully understood. This product is designed for indoor and outdoor use.
5. Ensure product operates within the specified temperature range. (Refer to 5. TECHNICAL SPECIFICATION for more details.)
6. Do not attempt to open the product. Not user serviceable.
7. Do not use the product if any part of it, or the power cables are damaged.
8. Only use product for specified voltage, do not exceed. (Refer to 5. TECHNICAL SPECIFICATION for more details.)
9. Always maintain connection to ensure waterproofing.
10. If the product has been subjected to drastic temperature variances, for example, following transportation, do not connect the fixture until it has reached room temperature, as moisture condensation may cause electric shock and product damages.
11. When installing the products and system power supplies, please ensure they will not be exposed to moisture and extreme heat (and direct sunlight for outdoor products). Besides, keep a clean operating environment for the fixtures and system power supplies.
12. Please study this Installation Guide thoroughly and check the latest Technical Specification Sheets available from the Traxon website www.traxontechnologies.com before setup.
13. Any non-compliance of the Installation Guide will void the Traxon warranty.
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 12/19 V1.0 P. 3 of 19
1. INTRODUCTION
1.1 General
The Allegro Linear AC series is a slim profile, AC line powered high brightness luminaire. The series is controllable via DMX512, and is available in four lengths. The luminaire can be simply daisy-chained to form long runs.
Model Power Consumption (W) Length (mm)
Allegro Linear AC 300 15 320
Allegro Linear AC 600 28 615
Allegro Linear AC 900 41 915
Allegro Linear AC 1200 55 1215
Features:
Outdoor applications
Protection Class IP66
Suitable for coastal environments
Impact rating IK07
Windforce compliant to IEC 60598-2-3
Vibration compliant to 3G ANSI C136.31
Input voltage: 220-240V AC, 120V/277V AC 50/60Hz
Integrated mounting feet with ±90° adjustment on beam aiming
DMX512
Remote Device Management (RDM)
CE, cETLus
DynaMood
®
: BinOne · BoostOne · AddressOne
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 12/19 V1.0 P. 4 of 19
1.2 Dimensions
320mm/12.6”
350mm/13.8”
300mm/11.8”
50mm/1.97”
86mm/3.4”
350mm/13.8”
FIG.1: Allegro Linear AC 300
FIG.2: Allegro Linear AC 600
50mm/1.97”
350mm/13.8”
615mm/24.2”
350mm/13.8”
86mm/3.4”
610mm/24”
590mm/23.2”
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 12/19 V1.0 P. 5 of 19
FIG.3: Allegro Linear AC 900
86mm/3.4”
50mm/1.97”
10mm/0.4”
86mm/3.4”
FIG.4: Allegro Linear AC 1200
10mm/0.4”
50mm/1.97”
915mm/36.0”
649mm/25.6”
625mm/24.6”
1215mm/47.8”
1039mm/40.9”
10mm/0.4”
10mm/0.4”
1015mm/40.0”