Traxon Allegro Dot L, Allegro Dot M Installation Manual

Allegro Dot M/L
INSTALLATION GUIDE
V1.1
Cover:
Allegro Dot M/L Direct View
Allegro Dot M/L Diffused View
CONTENT
1. INTRODUCTION
1. INTRODUCTION 3
2. INSTALLATION 8
3. SAFETY AND OPERATION 15
4. SYSTEM CONFIGURATION 16
5. CARE AND MAINTENANCE 18
6. TECHNICAL SPECIFICATION 19
7. TROUBLESHOOTING 20
8. WARRANTY STATEMENT 20
1.1 General
Allegro Dot is the next generation of intelligent media Allegro Dot family. The Allegro Dots are constructed on a flexible cable with customizable pitch. The Allegro Dots can provide advanced features and flexibility for lighting design and project execution.
The dots are single dot controllable by DMX, RDM, e:pix or Ethernet making this durable, scalable solution equally ideal for vivid accent, text, graphics, and video replay in installations of any size and complexity. Each string is connected via the Allegro Dot Pixel Distributor which can be easily configurable by RDM to form large installations.
The IP66 and IP67-rated, UV-resistant cover and aluminium casing make the Allegro Dot M/L suitable for a variety of outdoor applications.
Features:
DMX512, RDM, e:pix and Ethernet Control
Daisy Chain System
Auto-Addressing
Smart Junction Technology
Outdoor Applications (Allegro Dot M/L IP66 & IP67; Pixel Distributor IP66; LED Engine
IP67)
Suitable for irregular surfaces, planes, and configurations
Optional Diffuser Dome available
For your own safety and that of the product, please read this installation guide
carefully before beginning setup and installation.
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 2 of 21
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 3 of 21
1.2 Dimensions
FIG.1: Allegro Dot M/L Direct View
FIG.3: Allegro Dot M/L String
Ø31.3mm/1.2”
33mm/1.3”
51mm/2”
Ø3.9mm/0.15” x 2
Ø60mm/2.4”
44mm/1.7”
52mm/2”
Detail A scale 2:1
15.1mm/0.6”
17mm/0.7”
Ø60mm/2.4”
FIG.2: Allegro Dot M/L Diffused View
Ø3.9mm/0.15” x 2
Ø60mm/2.4”
44mm/1.7”
52mm/2”
Ø4mm/0.2”
1mm/0.03”
Ø4mm/0.2”
7.7mm/0.3”
7.7mm/0.3”
68mm/2.8”
68mm/2.8”
240mm/9.4”
Ø31.3mm/1.2”
68mm/2.8”
160mm/6.3” to first dot
25mm/0.98”
150mm/5.9”
97mm/3.8”
68mm/2.8”
1mm/0.03”
Detail A scale 2:1
39mm/1.5”
Ø60mm/2.4”
15.1mm/0.6”
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 4 of 21
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 5 of 21
1.3 Pixel Distributor
FIG.4: Allegro Dot M/L Pixel Distributor
1.5 Packing Contents
FIG.6: Allegro Dot M/L Packing Contents
Cable length: 300mm/11.8”
68mm/2.7”
50mm/2”
70mm/2.8”
Ø6.3mm/0.25” x 4
Cable length:
300mm/11.8”
M4 x 4
1.4 Smart Junction
FIG.5: Allegro Dot M/L Smart Junction
33mm/1.3”
204mm/8”
224mm/8.8”
244.2mm/9.6”
51mm/2”
20mm/0.79”
9mm/0.35”
FIG.7: Allegro Dot M/L Distributor Packing Contents
Ø31.3mm/1.2”
97mm/3.8”
240mm/9.4”
160mm/6.3” to first dot
25mm/0.98”
2 x 4.2 x 8 slots
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 6 of 21
Allegro Dot M/L Pixel Distributor
4 x Screws PSU Mounting
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 7 of 21
Allow slack on cable to
reduce stress
2. INSTALLATION
Connector should be properly connected with cable connectors and the DATA OUT of the last Pixel Distributor should be covered by its Waterproof End Cap to ensure IP66/67 rating.
2.1 Points To Consider
Plan your installation before mounting any luminaires. The following should be considered for a successful installation.
Weather conditions and ambient temperature of installation site.
Appropriate cable lengths
Adequate space for better heat dissipation (150mm apart) of LED Engines (see “2.3 On-
Site Installation” on page 12).
Appropriate anchor bolts where necessary to secure the Allegro Dot M/L.
The number of Allegro Dot M/L and appropriate Pixel Distributors with LED Engines.
Controller to be used to control the Allegro Dot M/L.
2.2 Pre-Installation Checks
2.2.1 Installation Checklist
1. Prepare cables and all necessary accessories.
2. Perform functional check of Allegro Dot M/L.
3. Ensure the DATA OUT connector on all Pixel Distributors are covered by the Waterproof End Cap after testing (see FIG.8 on page 9). Keep Waterproof End Caps safe for reuse.
4. Ensure all pre-installation checks laid out below have been followed.
5. Mount the Allegro Dot M/L on-site. If the installation is to be left uncompleted overnight, place all non-connected LED Engines, Pixel Distributors and Allegro Dot M/L in an indoor environment.
FIG.8: Seal last Pixel Distributor with Waterproof End Cap
Tightening Torque
0.49~0.69Nm (5~7kgfcm)
Waterproof End Cap
2.2.2 Handling The Allegro Dot M/L String
When transporting or preparing the Allegro Dot M/L string, please handle with care. To reduce stress on cables, carry by the Allegro Dots and not the cable during transit.
FIG.9: Correct way of handling Allegro Dot M/L String
Ensure all the Connection Cables, Allegro Dot M/L with LED Engines and Pixel Distributors are initially stored in a dry area to guarantee the complete sealing of the system from water before installation.
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 8 of 21
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 9 of 21
2.2.3 Requirements Of Cable Bending And Twisting
D
Ø9.5mm/0.37”
(Non-Bendable Length)
240mm/9.4”
4D
(Minimum Bending Radius)
38mm/1.50”
20mm/0.79”
D
Ø9.5mm/0.37”
50mm/1.97”
(Minimum Bending Radius)
38mm/1.50”
4D
2.2.4 Installation Sequence
Please take EXTRA precautions before bending or twisting Allegro Dot M/L cable.X-lock Lead Cable must NOT be bent below the Minimum Bending Radius (4x Cable Diameter) and the Non-Bendable Length of 50mm near the connector end or near the cable overmold MUST be adhered to.
FIG.10: Minimum Cable Bending and Non-Bendable Length Requirement
The flat Allegro Dot M/L Cable must NOT be bent/twisted below 20mm (0.79”) from edge of Allegro Dot housing (Non-Bendable/Non-Twistable Length).
Twisting the flat cable is NOT recommended. If twisting is necessary for installation, please adhere to the above Non-Twistable Length and ensure the mounting pitch is greater than or equal to 75% of the normal Allegro Dot to Allegro Dot pitch. The middle part of the cable must be secured to the mounting fixture with a cable tie (see “2.3 On-Site Installation” on page 12 and FIG.15 on page 14). Ensure no damage is generated on the cable.
FIG.11: Minimum Clearance
1. Plan for any possible bending of cables (refer to “2.2.3 Requirements Of Cable Bending And Twisting” on page 10).
2. Always keep the Waterproof End Cap on the Pixel Distributors or keep them safe in a container for reuse.
3. Connect Allegro Dot M/L with LED Engines and Pixel Distributors in the daisy-chain manner outlined in the System Diagram to form large installations.
4. Perform functional check on all Allegro Dot M/L and inspect cables for any damage. Check for any abnormalities with the signal.
5. Report any functional defect found to your nearest Traxon Technologies office. DO NOT attempt to install Allegro Dot M/L with functional defects on-site.
Minimum clearance from dot 20mm/0.79”
Non-Bendable/ Non-Twistable Length
NOTE: Water ingress incurred due to excess cable bending/twisting will not be under warranty by Traxon Technologies.
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 10 of 21
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 11 of 21
(M3 Screws not included)
if M3 screws are not viable
2.3 On-Site Installation
DO NOT attempt installation in wet or severe weather conditions.
DO NOT leave and expose any Allegro Dot M/L, Pixel Distributor or LED
Engine unconnected under wet/raining or snowing environment.
Ensure all the cable connectors of Allegro Dot M/L are removed from the
Pixel Distributors before installing.
DO NOT pull on cable of Allegro Dot M/L. IP failure induced by stressed/
damaged cables during or after installation will not be under warranty by Traxon Technologies.
ALWAYS keep the cables protected from sharp objects and ensure no
damage is generated on the cable.
Failure to keep Allegro Dot M/L within the operating temperature range of
-30°C to +60°C (+50°C for North America), -22°F to +140°F (+122°F for North America), and storage temperature range of –40°C to 70°C (–40°F to 158°F) will void the product’s warranty.
2.3.1 Mounting LED Engine
1. Fix LED Engine on top of Pixel Distributor with included M4 screws. NOTE: Keep adjacent LED Engines and Pixel Distributors a minimum 150mm (5.91”) apart for better heat dissipation.
FIG.12: Mounting LED Engine on top of Pixel Distributor
2.3.2 Mounting Allegro Dot M/L
1. Allegro Dot M/L must be mounted without any stress induced at the boundary area of the cable and Allegro Dot.
2. Allegro Dots MUST be mounted to the installation surface via the mounting holes, either by screw or cable tie.
FIG.13: Mounting the Allegro Dot M/L
(Cable ties not included)
(M3 Screws not included)
Suggested alternative method
3. Cable segment must not be bent below 20mm from the housing of the Allegro Dot M/L and cable overmold (Minimum Bending Length).
4. Secure the cables between Allegro Dot M/L (every 500mm, using cable tie) and create a small clearance beneath the cable (see below diagram). Ensure no damage is generated on the cable.
FIG.14: Securing the cable
LED Engine mounts on top of the Pixel Distributor (LED Engine is ordered separately) Mount Pixel Distributor with connectors facing down
M4 × 8mm × 4 (Included)
M5 anchor bolts (Not included)
150mm/5.91”
clearance
150mm/5.91”
clearance
150mm/5.91”
clearance
150mm/5.91”
clearance
2. Mount the Pixel Distributor with 4 × M5 Anchor Bolts (not included). Recommended orientation is with connectors facing DOWN (see above diagram).
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 12 of 21
150mm/5.91”
clearance
150mm/5.91”
clearance
Observe clearance
Cable tie
Mounting surface
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 13 of 21
5. If the cable between Allegro Dot M/L requires twisting due to a change in mounting direction, ensure the mounting pitch after-twisting is more than or equal to 75% of the normal Dot to Dot pitch.
FIG.15: Twisting requirements
Non-Twistable Length
20mm/0.79”
Secure center of cable with cable tie
L = Length of cable
≥75% L
Non-Twistable Length
20mm/0.79”
Secure center of cable with cable tie
L = Length of cable
≥75% L
Non-Twistable Length
3. SAFETY AND OPERATION
1. CAUTION - Unplug the power supply from the mains power before connecting any cables as this can damage the products.
2. CAUTION - Avoid looking directly into the LED light source at close range for your own safety.
3. Persons installing this product should make sure:
a. The installation complies with all applicable codes, state and local laws,
ordinances, standards and safety regulations.
b. The installation environment is carefully studied and suitable surge protection
measure(s) is taken.
c. He or she is qualified for the handling of electrical equipment.
4. Do not attempt to install or use the product until installation instructions and safety labels are fully understood. This product is designed for indoor and outdoor use.
5. Ensure product operates within the specified temperature range. (Refer to 6. TECHNICAL SPECIFICATION for more details.)
6. Do not attempt to open the product. Not user serviceable.
7. Do not use the product if any part of it, or the power cables are damaged.
8. Only use product for specified voltage, do not exceed. (Refer to 6. TECHNICAL SPECIFICATION for more details.)
9. Always maintain connection to ensure waterproofing.
10. If the product has been subjected to drastic temperature variances, for example, following transportation, do not connect the fixture until it has reached room temperature, as moisture condensation may cause electric shock and product damages.
11. When installing the products and system power supplies, please ensure they will not be exposed to moisture and extreme heat (and direct sunlight for outdoor products). Besides, keep a clean operating environment for the fixtures and system power supplies.
12. Please study this Installation Guide thoroughly and check the latest Technical Specification Sheets available from the Traxon website www.traxontechnologies.com before setup.
13. Any non-compliance of the Installation Guide will void the Traxon warranty.
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 14 of 21
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 15 of 21
4. SYSTEM CONFIGURATION
FIG.16: System Diagram – e:net connection
FIG.17: System Diagram – SYMPL DMX/e:pix node
End cap
End cap
DMX/e:pix connection
Max. number of Pixel Distributors in the daisy
chain for standard model from ordering list.
DMX/RDM: 60 units max.
Maximum number of Pixel Distributors
e: pix: 15 units max.
in the daisy chain depends on
available DMX and e:pix channels from
1st pixel distributior.
(Please refer the table below):
Cable C
LED Engine 240W/185W/100W 30V Outdoor
Installation engineer should use
appropriate plugs for outdoor
Mains AC ~
Outdoor
e:net connection
connection.
Allegro Dot Pixel Distributor
Cable A
DMX
e: pix
M 3 2
L 4 3
M 13 10
L 15 12
Dot RGB RGBW
Cable B
Smart
Junction
RJ45 Male Connector Housing IP67
Outdoor cable specification:
To construct a longer data cable,
use outdoor data cable with RJ45
housing.
Cable A
1PXL dots,
CAT-5e UTP/FTP
Cable B
TX Connect Data Bridge
Indoor/Outdoor Cable (5m)
Maximum: 50m
RGBW: 4 channels per dot
RGB: 3 channels per dot
Dot pitch:
150mm minimum,
4000mm maximum
The maximum number of
PVC jacket; UV resistant
Outer diameter 6mm/0.24”
Filled type
(The warranty will void if in use
cable is not follow the
specification of outdoor cable)
Cable C
TX Connect Data Outdoor Cable
X-lock Lead Cable (5m/10m)
Pixel
0.6m/2ft or 3m/10ft available
(standard model with dot
pitch 150mm)
RGB: 60
RGBW: 60
CAUTION:
Last dot of string
The length of the cable between the pixel distributor and the first lamp or lamp holder shall
not be less than 1.5m.
DMX/e:pix connection
Maximum number of Pixel Distributors
in the daisy chain depends on
available DMX and e:pix channels
from DMX/e:pix node.
DMX/RDM: 60 units max.
e: pix: 15 units max.
Max. number of Pixel Distributors in the daisy
Cable C
LED Engine 240W/185W/100W 30V Outdoor
Allegro Dot Pixel Distributor
Installation engineer should use
appropriate plugs for outdoor
connection.
Mains AC ~
Outdoor
RJ45 Plug
Pin 2: DMX+
Pin 3: GND
Pin 1: DMX–
DMX/e:pix connection
Cable A
DMX
e: pix
Cable A
Dot RGB RGBW
M 3 2
L 4 3
chain for standard model from ordering list.
(Please refer the table below):
M 13 10
Cable B
RJ45 Male Connector Housing IP67
To construct a longer data cable,
use outdoor data cable with RJ45
TX Connect Data Bridge
L 15 1 2
Smart
Junction
1PXL dots,
housing.
Outdoor cable specification:
CAT-5e UTP/FTP
PVC jacket; UV resistant
Outer diameter 6mm/0.24”
Filled type
Cable B
X-lock Lead Cable (5m/10m)
Indoor/Outdoor Cable (5m)
Maximum: 50m
RGBW: 4 channels per dot
RGB: 3 channels per dot
Dot pitch:
150mm minimum,
4000mm maximum
The maximum number of
Pixel
(standard model with dot
pitch 150mm)
(The warranty will void if in use
cable is not follow the
specification of outdoor cable)
Cable C
TX Connect Data Outdoor Cable
0.6m/2ft or 3m/10ft available
CAUTION:
Last dot of string
RGB: 60
RGBW: 60
The length of the cable between the pixel distributor and the first lamp or lamp holder shall
not be less than 1.5m.
Indoor
Ethernet Switch
SYMPL Core S
To other distributor chain
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 16 of 21
Indoor
SYMPL DMX Node
SYMPL Core S
e:net
connection
Ethernet Switch
To other DMX Nodes
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 17 of 21
5. CARE AND MAINTENANCE
6. TECHNICAL SPECIFICATION
Traxon™ products are of superior design and quality and should be treated with care. The recommendations below will help fulfill any warranty obligations and gain good use and longevity from the products.
Do not attempt or use the product(s) until you read and understand the installation
instructions. Failure to adhere to these instructions could result in serious injury or property damage.
Do not use product(s) if cables are damaged.
Do not connect cables and connectors when wet or in wet area. Moisture on bare
connectors can cause electric shock and damage to product(s).
Do not use product(s) in extreme heat environment. Ensure there is sufficient airflow and
use cool air circulation if required.
Do not drop, knock, or shake product(s). Rough handling can damage the electronics and
void the warranty.
Do not use harsh chemicals, cleaning solvents, or strong detergents to clean products.
Wipe with a damp cloth on housings and a dry cloth on electronics to remove dirt or dust.
Do not attempt to service or repair the product(s) unless done by an authorized service
personnel. Contact your local Traxon office or distributor for details.
If the product is not working as specified, please contact your nearest authorized service
center or Traxon Technologies office for assistance.
Model Allegro Dot M
Direct View
Allegro Dot M Diffused View
Allegro Dot L Direct View
Allegro Dot L Diffused View
Color Range: 16.7 Million additive RGB colors, white CCT 6500K
Light Source: RGB: 6 RGB LEDs
RGBW: 6 RGB LEDs + 3 White
RGB: 9 RGB LEDs RGBW: 9 RGB LEDs + 3 White
Beam Angle: 110° 150° 110° 150°
Power Input: 30V DC
Power Consumption1:
Weight (Dot): 80g
Weight (Pixel
RGB: 2W RGBW: 2W
670g
90g
RGB: 2.5W RGBW: 3W
80g
90g
Distributor):
Operating Temperature:
Storage
-30°C to +60°C/-22°F to +140°F
-30°C to +50°C/-22°F to +122°F (for North America)
-40°C to +70°C/-40°F to +158°F
Temperature:
1. Measurement per dot.
As with all electronic devices, LED output degrades over time - a term called lumen depreciation. This also explains why it is nearly impossible to expect photometric performances of two LED products with different service life spans to be the same. The rate of LED degradation is a complex function of many factors such as operating efficiency, duration of continuous operation, and operating conditions (e.g. ambient temperature).
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 18 of 21
Because LEDs are semiconductor devices, their performances are subject to inherent variability commonly found in semiconductor industry. To improve consistency in performance across the same product, LED manufacturers “sort” LEDs into bins according to different preset parameters, such as forward driving voltage, illumination, etc. Whereas binning is a sorting function, it is not a correction process. Inherent variability in the manufacturing process always results in different binning distributions according to different production lots. Traxon uses automatically binned LEDs on its products, thereby minimizing output variations within the model range.
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 19 of 21
7. TROUBLESHOOTING
CAUTION: Ensure power supply is OFF when disconnecting / connecting cables.
Problem Cause Possible Solutions
Product does NOT light up after installation
Shadowing Light source covered Adjust pitch between Allegro Dot M/L
Modules are dim
Flickering Incorrect power input/
If problems persist or the product is not working as specified, please contact your nearest authorized service center or Traxon Technologies office for assistance.
Incorrect power connection
Excess products connected
Excess products connected
Check Mains Power
Check power supply leads and wire
connections
Ensure output wires are connected with
proper polarity
strings
Check for cables, wires or unwanted
debris covering LED light source
Ensure the power supplies are not
overloaded due to an excess of products connected
Ensure the input voltage is correct
Ensure the power supplies are not
overloaded due to an excess of products connected
8. WARRANTY STATEMENT
Traxon Technologies warrants its Products against material or workmanship defects for a period of five (5) years from date of purchase, provided that the purchased items are used under the conditions stated in this user manual.
Please refer www.traxontechnologies.com for all warranty terms and conditions.
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide 06/19 V1.1 20 of 21
Please check for the latest updates and changes on the Traxon website. © 2019 TRAXON TECHNOLOGIES ALL RIGHT RESERVED. Information is subject to change without prior notice. www.traxontechnologies.com
Loading...