If this appliance is not properly installed, a house fire may
result. For your safety, follow the installation directions.
Contact local building or fire officials about restrictions and
installation inspection requirements in your area.
Copyright 2007, T.I.
$10.00 100-01164
4050922
Listed
Tested to: U.L. 1482
Page 2
2Introduction
Introduction
We welcome you as a new owner of a Lopi Liberty wood-burning stove. In purchasing a Lopi Liberty you
have joined the growing ranks of concerned individuals whose selection of an energy system reflects both
a concern for the environment and aesthetics. The Lopi Liberty is one of the finest appliances the world
over. This manual will explain the installation, operation, and maintenance of this appliance. Please
familiarize yourself with the Owner's Manual before operating your appliance and save the manual for
future reference. Included are helpful hints and suggestions which will make the installation and
operation of your new appliance an easier and more enjoyable experience. We offer our continual
support and guidance to help you achieve the maximum benefit and enjoyment from your appliance.
Important Information
No other Lopi Liberty appliance has the same serial
number as yours. The serial number is stamped onto
the label on the back of the appliance.
Mail your Warranty Card Today, and Save Your Bill
of Sale.
This serial number will be needed in case you require
service of any type.
Model: Lopi Liberty
Serial Number:
Purchase Date:
Purchased From:
To receive full warranty coverage, you will need to
show evidence of the date you purchased your
appliance. Do not mail your Bill of Sale to us.
We suggest that you attach your Bill of Sale to this
page so that you will have all the information you need
in one place should the need for service or information
occur.
The viewing door must be
closed and latched during
operation.
Never block free airflow through
the air vents on this appliance.
This appliance is designed and
approved for the burning of cord
wood only. Do not attempt to
burn any other type of fuel other
than cord wood in this
appliance, it will void all
warranties and safety listings.
Do not touch the appliance while
it is hot and educate all children
of the danger of a hightemperature appliance. Young
children should be supervised
when they are in the same room
as the appliance.
36"
Gas
ASHES
Gasoline or other flammable
liquids must never be used to
start the fire or "Freshen Up" the
fire. Do not store or use
gasoline or other flammable
liquids in the vicinity of this
appliance.
Ashes must be disposed in a
metal container with a tight lid
and placed on a noncombustible surface well away
from the home or structure.
Keep furniture, drapes, curtains,
wood, paper, and other
combustibles a minimum of 36"
away from the front of the
appliance.
This appliance must be properly
installed to prevent the
possibility of a house fire. The
instructions must be strictly
adhered to. Do not use
makeshift methods or
compromise in the installation.
Inspect the chimney connector
and chimney at least twice
monthly and clean if necessary.
Creosote may build up and
cause a house fire.
Do not connect this appliance to
any chimney serving another
appliance.
Type
HT
Ok
Clay
Liner
Contact your local building
officials to obtain a permit and
information on any installation
restrictions or inspection
requirements in your area.
Notify your insurance company
of this appliance as well.
This appliance must be
connected to a listed high
temperature (UL 103 HT)
residential type chimney or an
approved masonry chimney with
a standard clay tile, or stainless
steel liner.
When installed in a mobile
home, this appliance must be
bolted to the floor, have outside
air, and not be installed in the
bedroom (Per H.U.D.
requirements). Check with local
building officials.
Do not place clothing or other
flammable items on or near this
appliance.
Never try to repair or replace
any part of this appliance unless
instructions are given in this
manual. All other work must be
done by a trained technician.
Allow the appliance to cool
before carrying out any
maintenance or cleaning.
Maintain the door and glass seal
and keep them in good
condition.
Avoid placing wood against the
glass when loading. Do not
slam the door or strike the glass.
Do not make any changes or
modifications to an existing
masonry fireplace or chimney to
install this appliance.
Do not make any changes to the
appliance to increase
combustion air.
Overfiring the appliance may
cause a house fire. If a unit or
chimney connector glows, you
are overfiring.
Do not use a grate or other
device to elevate the fire off of
the firebox floor. Burn the fire
directly on the bricks.
Do not throw this manual away.
This
Manual
This manual has important
operating and maintenance
instructions that you will need at
a later time. Always follow the
instructions in this manual.
Travis Industries, Inc. grants
no warranty, implied or
stated, for the installation or
maintenance of your
appliance, and assumes no
responsibility of any
consequential damage(s).
Page 6
6Features & Specifications
Installation Options
• Freestanding
• Freestanding in an Alcove
• Freestanding in a Mobile Home
• Freestanding Hearth Stove
Features
• EPA Phase II Approved
• 3.1 Cubic Foot Firebox Volume
• Single Operating Control
• Accepts Logs Up to 24" Long
• Steel Plate Construction (5/16" & 3/16")
• Heavy Duty Refractory Firebrick
• Optional High-Tech Blower
Heating Specifications
Approximate Maximum Heating Capacity (in square feet)*1,500 to 2,500
Maximum BTU's per Hour (Cord Wood Calculation)74,300
Overall Efficiency (Oregon Method)70 %
Maximum Burn TimeUp to 12 Hours
* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature.
It is also affected by the quality and moisture level of the fuel.
Dimensions
30”
Weight: 470 Lbs.
21”
6-1/4”
The 6” diameter flue collar protrudes
1-1/4" above the stove top
Note:
Measure side, corner, and back
clearances from the stove top.
Measure front clearances from
the stove face.
Height:
Sculptured or Cast Legs....32-1/4"
Pedestal.............................36-1/4"
Emissions
2.6 Grams Per Hour (EPA Phase II Approved) – Tests conducted by E.E.S.P.C.
Please read this entire manual before you install and use your new room heater. Failure
to follow instructions may result in property damage, bodily injury, or even death.
Contact local building or fire officials about restrictions and installation inspection
requirements in your area.
Planning The Installation
We suggest that you have an authorized Travis Industries dealer install your stove. If you install the
stove yourself, your authorized dealer should review your installation plans.
Check with local building officials for any permits required for installation of this stove and notify your
insurance company before proceeding with installation.
Preparation for Installation
•Check for damage to the exterior of the stove (dents should be reported, scratches can be fixed by
applying touch up paint).
•Check the interior of the firebox (replace cracked firebrick and make sure baffle is in place).
The stove can be lightened by removing the firebricks and baffle (pg 28) - replace before operation.
Additional Accessories Needed for Installation
• Door Shell (Black 99300165 Brass 99300166 - see pg 32)
• Legs or Pedestal
Stove Installation Considerations
The table below details the six most common types of installations and the considerations for each type.
Alternative methods of installation are available if they comply with local building codes.
Installation TypeConsiderations
Standard Ceiling with a Factory Built Chimney
(Page 14)
Cathedral Ceiling with a Factory Built Chimney
(Page 14)
Exterior Factory Built Chimney
(Page 15)
Hearth Stove Positive Connection
(Page 15)
Hearth Stove Direct Connection
(Page 16)
Interior Masonry Chimney
(Page 16)
• Requires ceiling and roof penetration
• Provides best draft
• Cathedral style chimney support required
• Provides best draft
• Uses two elbows to route chimney outside
• Exterior chimney is hidden from the room
• Elbows reduce draft
• Optional exterior chase reduces cold air blockage
• Utilizes existing masonry or zero clearance (metal) chimney
• Provides good draft due to full reline
• Easier to clean than direct or horizontal hearth stove
• Utilizes existing masonry or zero clearance (metal) chimney
• Requires construction of a "block-off plate"
• Draft reduced due to elbows & chimney cross section
• Utilizes existing masonry chimney (not approved for zero
• Stove must be placed on the Travis Industries legs or Pedestal.
• Floor protection must extend 6" to the sides and rear of the stove and 16" to the front of the stove
(42" wide by 43" deep - see Figure 2 and Figure 3).
•Floor protection must be non-combustible and at least .018" thick (26 guage).
Stove Placement Requirements
Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or
other means approved by local building or fire officials.
•Stove must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors), 36"
of the front of the stove
•If the stove is placed in a location where the ceiling height is less than 7', it must follow the
requirements in the section "Alcove Installation Requirements"
•Must maintain the clearances to combustibles listed below (drywall, furniture, etc.):
Clearances
• The following clearances must be met (see Figure 2 and Figure 3)
Minimum ClearanceSinglewall
Connector
ASidewall to stove16"16"
BBackwall to stove15”10"
CCornerwall to stove9-1/2"7-1/2"
DConnector to sidewall28"27-1/2"
EConnector to backwall18-1/4"12-3/4"
FConnector to cornerwall21"18-1/2"
*Reduced clearance installations require one of the chimneys and connectors listed below:
AMERI-TEC model DCC with model HS chimney
DURAVENT model DVL with DURATEC or DURA-PLUS chimney
I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
METALFAB model DW connector with TG chimney
SECURITY model DP connector with SECURITY model ASHT or S2100 chimney
Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.
NOTE: Standard residential installations with reduced clearance connector may use the clearance
determined by the manufacturer of the connector for the connector to wall clearance or the clearance
listed in this manual. Offsets must be used to maintain the stove to wall clearance.
Minimum Air Space to Combustibles
(See Chimney Manufacturer's
Instructions - usually 2")
Minimum System 15'
Maximum System 33'
}
Standard residential installations with reduced
clearance connector may use the clearance determined by
Reduced Clearance Chimney
Connector Sections
}
Floor
Protection
Drafting
Performance
Standard residential installations may use single-wall connector (Mobile-Homes may not)
•Standard residential installations with reduced clearance connector may use the clearance
determined by the manufacturer of the connector for the connector to wall clearance or the clearance
listed in this manual. Offsets must be used to maintain the stove to wall clearance. Mobile homes
must use the clearances listed in this manual under "Additional Requirements for Mobile Home
Installations".
This appliance relies upon natural draft to operate. External forces, such as wind,
barometric pressure, topography, or factors of the home (negative pressure from exhaust
fans, chimneys, air infiltration, etc.), may adversely affect draft. Travis Industries can not be
responsible for external forces leading to less than optimal performance.
the manufacturer of the connector for the connector to wall
clearance or the clearance listed in this manual.
Mobilehome installations must use the the reduced
clearance connector clearances listed in this manual under
“Additional Requirements for Mobile Home Installations”.
• Must have an approved cap (to prevent water from entering)
• Must not be located where it will become plugged by snow or other material
• Must terminate at least 3' above the roof and at least 2' above any portion of the roof within 10' (see
Figure 5)
Slanted Roofs
Chimney must
extend 3'
above the roof
lat Roofs
Chimney must
extend 3'
above the roof
Chimney must extend 2'
above any portion of the roof
within 10' of the chimney
Outside Air Requirements
• Required for mobile homes & in certain localities (check with building officials)
• Must not be drawn from an enclosed space (garage, unventilated crawl space)
• Requires the optional outside air boot (for legs) or pedestal.
Chimney must extend 2'
above any portion of the roof
within 10' of the chimney
Figure 5
When using outside air, find a location where the chimney and
outside air hole do not interfere with structural members of the home.
Pedestal (with insulation)
directs air to the stove.
Air may be drawn from a ventilated
crawl space or use an air duct.
A hole must be cut
through the floor
protection and floor
and the rodent
screen nailed in
place here (see the
optional equipment
instructions for
exact sizes)
Optional Air Duct (must not be
longer than 15' and at least 16
square inches in cross section)
Outside air entrance must be placed so
it does not become blocked by snow.
Whenever the stove is placed in a location where the ceiling height is less than 7' tall, it is considered an
alcove installation. Because of the reduced height, the special installation requirements listed below must
be met.
•Chimney connector and chimney must be one of the following types:
AMERI-TEC model DCC with model HS chimney
DURAVENT model DVL with DURATEC or DURA-PLUS chimney
I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
METALFAB model DW connector with TG chimney
SECURITY model DP connector with SECURITY model ASHT or S2100 chimney
Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.
•Alcoves are classified as combustible or non-combustible. Non-combustible alcoves must have walls
and a ceiling that are 3 1/2" thick of a non-combustible material (brick, stone, or concrete - see Figure
7). This non-combustible material must be spaced and ventilated at least 1" off of all combustible
materials (walls, ceiling, etc.) to allow air to move around the non-combustible walls and ceiling. All
other alcoves are considered combustible. The clearances below must be met:
Minimum Clearance
(See the Figure 7 below)
Combustible
Alcove
Non-Combustible
Alcove
ASidewall to stove16"6"
BBackwall to stove10"2"
DConnector to sidewall27-1/2"17-1/2"
EConnector to backwall12-3/4"4-3/4"
GMaximum depth of alcove48"48"
HMinimum width of alcove62"42"
JMinimum height of alcove84"6" above stove top
Non-combustible alcove
construction (on walls
and ceiling) - see the
explanation above.
• Outside air must be installed - see "Outside Air Requirements" on page 11
• Chimney connector and chimney must be one of the following types:
AMERI-TEC model DCC with model HS chimney
DURAVENT model DVL with DURATEC or DURA-PLUS chimney
I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
METALFAB model DW connector with TG chimney
SECURITY model DP connector with SECURITY model ASHT or S2100 chimney
Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.
•Stove placement must maintain the following clearances to combustibles (drywall, furniture, etc.)
Rear heat
b
e
a
d
shield
f
c
c
Measure all clearances from the
nearest edge of the stove top.
Minimum Clearance
(See the illustration above)
Reduced Clearance
Connector
ASidewall to stove16"
BBackwall to stove10"
CCornerwall to stove7-1/2"
DConnector to sidewall27-1/2"
EConnector to backwall12-3/4"
FConnector to cornerwall18-1/2"
•If using offsets, use the connector clearance listed in Figure 9,
not the connector manufacturer's clearance.
•The appliance must be secured to the floor (consult your
building official). Secure the outside air boot to the floor and
stove to insure the stove does not dislocate.
•Mobile home installations require a spark arrester at the
chimney termination.
•The appliance must be grounded to the chassis of the mobile
home (consult your building official).
• WARNING:DO NOT INSTALL IN SLEEPING ROOM.
• CAUTION:THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALL, AND CEILING/ROOF MUST BE
MAINTAINED.
Chimney Cap
(See the section "Chimney
Termination Requirements"
for more details)
Chimney Sections
Insulation
Follow the chimney
manufacturer's instructions
and clearances for floor
penetrations. A ceiling
support is required, an attic
insulation shield is required
where insulation is present.
Chimney Connector Sections
Floor Protection
(See the section "Floor
Protection Requirements"
for more details)
}
}
Follow the chimney
manufacturer's instructions
and clearances for roof
penetrations. A storm collar
and flashing are required
(some require a radiation
shield).
Minimum Air Space to
Combustibles (See
Chimney Manufacturer's
Instructions - usually 2")
Minimum 15'
Maximum 33'
Stove Clearances
(See the section "Stove
Placement Requirements"
for more details)
Cathedral Ceiling
with a Factory
Built Chimney
Chimney Cap
(See the section "Chimney
Termination Requirements"
for more details)
Chimney Sections
Minimum Air Space to
Combustibles (See Chimney
Manufacturer's Instructions usually 2")
Chimney
Connector
Sections
Floor Protection
(See the section "Floor
Protection Requirements"
for more details)
}
Figure 10
Follow the chimney
manufacturer's instructions
and clearances for roof
penetrations. A storm
collar, flashing, and
cathedral-style chimney
support are required
(some require a radiation
shield).
Minimum 15'
Maximum 33'
Stove Clearances
(See the section "Stove
Placement Requirements"
for more details)
Exterior chimneys are
subject to greater
moisture and creosote
accumulation due to the
lower temperatures. An
insulated chase will
reduce these
accumulations (the
proper clearances to the
chimney must be
maintained).
himney Cap
See the section "Chimney
ermination Requirements"
or more details)
Chimney Sections
inimum Air Space to
ombustibles (See
himney Manufacturer's
nstructions - usually 2")
Min. 18"
clearance to
ceiling
Chimney Connector
Sections
Floor Protection
(See "Floor
Protection
Requirements"
for details)
Wall Bands
and
Supports
}
Minimum 15'
Maximum 33'
}
Stove Clearances
(See the section "Stove
Placement Requirements"
for more details)
Follow the chimney
manufacturer's
instructions and
clearances for roof
penetrations. A storm
collar and flashing are
required (some
require a radiation
shield).
Insulated Tee
(with cleanout )
Follow the chimney
manufacturer's
instructions and
clearances for wall
penetrations. A
wall radiation shield
(thimble) is
required.
Optional
insulated
chase
Figure 12
Hearth Stove
Positive
Connection
NOTE:
Most factory-built
chimney manufacturers
make stainless steel
chimney liners, either
flexible or rigid. This
provides a wide variety
of installation options.
Make sure to follow the
manufacturer's
instructions for
installation and support.
NOTE: The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes
(UBC, etc.). Damage must be
repaired prior to installation. The
chimney must be 15' to 33' tall.
Combustible
Mantle
Min. 18"
Floor Protection
(See the section
"Floor Protection
Requirements"
for more details)
Cap and flashing
prevents water from
entering
The liner must be
stainless steel connector
or flexible vent. Follow
the liner manufacturer's
instructions for installation
and support.
Airtight Insulated
Clean-Out
Remove damper
or wire it open
See the section
"Stove Placement
Requirements" for
minimum clearances
required.
Direct connections require
installation of an airtight,
non-combustible block-off
plate or damper adapter.
NOTE: The chimney must have a clay
tile liner. If it does not, the installation
must use a positive connection (full
reline). The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes (UBC,
etc.). Damage must be repaired prior
to installation. The chimney must be
15' to 33' tall.
Max. 8”
Combustible Mantle
Clay
Liner
Stainless steel
chimney connector
must Extend 1' past
the block-off plate or
to the flue liner
Airtight
Insulated
Clean-Out
Interior or Exterior
Masonry Chimney
NOTE:
This type of installation
requires a UBC approved
masonry connector or a
factory built (U.L. Listed)
wall thimble.
Min. 18"
Floor Protection
(See the section "Floor
Protection Requirements"
for more details)
NOTE: The chimney must have a
clay tile liner. If it does not, the
installation must use a positive
connection (full reline). The
entire fireplace and chimney must
be clean, undamaged, and meet
all local building codes (UBC,
etc.). Damage must be repaired
prior to installation. The chimney
must be 15' to 33' tall.
See the section "Stove
Placement Requirements" for
minimum clearances required.
Chimney connector sections
Remove damper
or wire it open
Block-off plate or
damper adapter
See the section
"Stove Placement
Requirements" for
minimum clearances
required.
Figure 14
Clay Liner
Min. 18"
clearance
to ceiling
This type of
installation requires
a UBC approved
masonry connector
or a factory built
(U.L. Listed) wall
thimble.
If this appliance is not properly installed, a house fire may result. For your safety, follow the installation
directions. Contact local building or fire officials about restrictions and installation inspection
requirements in your area.
Read and follow all of the warnings on pages 4 and 5 of this manual.
Before Your First Fire
Verify the Installation
Before starting the stove, verify that the stove is properly installed and all of the requirements in this
manual have been followed.
Keep all flammable materials 36" away from the front of the stove (drapes, furniture, clothing, etc.).
Curing the Paint
This heater uses a heat-activated paint that will emit some fumes while starting
the first fire. Open doors and windows to the room to vent these fumes. This
typically lasts two to four hours. You may also notice oil burning off of the interior
of the heater. This rust-stopping agent will soon dissipate.
Door Gasket - The door gasket might adhere to the paint on the front of the
heater. Leave the door slightly ajar for the first fire and be careful when opening
the door after the first fire.
2 to 4 hours
Over-Firing the Stove
This stove was designed to operate at a high temperature. But due to differences in vent configuration,
fuel, and draft, this appliance can be operated at an excessive temperature. If the stove top or other area
starts to glow red, you are over-firing the stove. Shut the air control down to low and allow the stove to
cool before proceeding.
Over-firing may lead to damage of plated surfaces. If you are uncertain of over-firing conditions, we
suggest placing a stove thermometer (e.g. Rutland® Model 710) directly over the door on the stove top temperatures exceeding 800° are generally considered over-firing and will void the warranty.
Opening the Door
Rotate
the door
handle.
The door becomes hot during use. Use a glove to open the door if the handle is hot.
To prevent smoke from entering the room, open the bypass before opening the door (see following page
for directions). You can also open the door a small amount and let air enter the firebox.
The bypass controls the flow of smoke inside the heater. When pulled out, smoke goes directly up the
flue, creating more draft. When pushed in, the smoke goes around the baffle, utilizing the secondary
combustion and making the heater more efficient.
• When starting or re-loading, pull the bypass out.
• During normal operation, push the bypass in.
Bypass Pulled Out
Use the included pull tool
to operate the bypass rod
Since the dawn of time man has debated the best way to start a fire. Some use the boy-scout "tee-pee",
some prefer the "tic-tac-toe" stack. Either way, review the hints and warnings below to ensure proper fire
starting.
•Make sure the air control is pushed in and by-pass pulled out. If additional air is needed, open the
doors 1/4" during the first five minutes of start-up.
Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start
or "freshen up" a fire in this stove. Keep all such liquids well away from the stove while it is in use.
If using a firestarter, use only products specifically designed for stoves - follow the manufacturer's
instructions carefully.
If the smoke does not pass up the chimney, ball up one sheet of newspaper, place it in the center of the
firebox and light it. This should start the chimney drafting (this eliminates "cold air blockage").
Use plenty of kindling to ensure the stove reaches a proper temperature. Once the kindling is burning
rapidly, place a few larger pieces of wood onto the fire.
Use the air control slider to control the burn rate of the stove. See the illustration below for details.
Use the air control to
change the burn rate.
Low Burn
(air control closed)
High Burn
(air control open)
Approximate Air Control Settings
Overnight BurnFully out to 9/32" open
Medium Burn9/32" open to 5/16" open
Medium High Burn5/16" open to 7/16" open
High Burn7/16" open to pushed fully in
The air control becomes hot during operation - use gloves or a tool to prevent burns.
The air control may take several minutes to influence the burn rate. When making adjustments, you
may wish to let the stove burn for 10 minutes to gauge performance.
Ash Removal
Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes
should be placed on a noncombustible floor or on the ground, away from all combustible
materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally
dispersed, they should be retained in the closed container until all cinders have thoroughly
cooled.
Page 21
Operating Your Appliance21
Optional Blower Operation
The blower will turn on once the stove is up to temperature. This is typically 15 to 30 minutes after
starting the fire. Follow the directions below to alter the blower speed.
OFF
Turn the dial all the way counterclockwise until it clicks off.
OFF
HI
LO
BLOWER
CONTROL
The high position is all the way counterclockwise,
HIGH
without clicking off.
OFF
HI
LO
BLOWER
CONTROL
LOW
Turn the dial all the
way clockwise.
OFF
LO
BLOWER
CONTROL
The blower may be used to affect heat output (i.e.: to reduce heat output, turn the blower down).
Route the power cord in a location where it will not come in contact with the appliance or become hot.
Re-Loading the Stove
Follow the directions below to minimize smoke spillage while re-loading the stove.
1 Open the air control (push it in). Open the bypass (pull it out).
2 Open the door slightly. Let the airflow inside the firebox to stabilize before opening the doors fully.
3 Load wood onto the fire.
Overnight Burn
HI
This stove is large enough to accommodate burn times up to eight hours. Follow the steps below to
achieve an overnight burn.
1 Move the air control to high burn and let the stove become hot (burn for approximately 15 minutes).
2 Load as much wood as possible. Use large pieces if possible.
3 Let the stove burn on high for 15 minutes to keep the stove hot, then turn the air control to low.
4 In the morning the stove should still be hot, with embers in the coal bed. Stir the coals and load
small pieces of wood to re-ignite the fire, if desired.
Differences if chimney height and draft may lower overall burn times.
Normal Operating Sounds
Creaks and Clicks:
The 3/16" and 5/16" steel may creak or click when
the stove heats up and cools down - this is normal.
Blower Sounds:
The blower will make a slight "humm" as it
pushes air through the stove.
Hint:
Make sure the leveling bolts on legs are extended preventing the hearth from amplifying any vibrations.
• Get the appliance hot before adjusting to low burn
• Use smaller pieces of wood during start-up and high burns to increase temperature
• Use larger pieces of wood for overnight or sustained burns
• Stack the wood tightly together to establish a longer burn
• Leave a bed of ashes (1/2" deep) to allow for longer burns
• Be considerate of neighbors & the environment: burn dry wood only
• Burn small, intense fires instead of large, slow burning fires when possible
• Learn your appliance's operating characteristics to obtain optimum performance
Selecting Wood
• Dry Wood is Key
• Dry wood burns hot, emits less
smoke and creates less creosote.
Wet
Wood
Leads
To
Dry
Wood
• Testing Wood Moisture
• Split wood stored in a dry area will
be fully dry within a year. This
insures dry wood. If purchasing
wood for immediate use, test the
wood with a moisture meter. Some
Less
Heat
More
Heat
Leads
To
experienced wood burners can
measure wood moisture by
knocking pieces together and
listening for a clear "knock" and not
a "thud".
More Smoke
and Creostoe
Less Smoke
and Creostoe
Why Dry Wood is Key
Wet wood, when burned, must release water stored within the wood. This cools the fire, creates
creosote, and hampers a complete burn. Ask any experienced wood burner and he or she will agree: dry
wood is crucial to good performance.
Store the wood off the ground in a
covered area. Allow for airflow
around the wood to dry the wood.
Air Flow
Air Flow
Air Flow
Page 23
Operating Your Appliance23
Troubleshooting
ProblemPossible Cause
Smoke Enters Room During
Start-Up
Kindling Does Not Start - Fire
Smolders
Smoke Enters Room While ReLoading
• Open the bypass (pg. 18).
• Open the air control (pg. 20).
• Cold Air Blockage - burn a piece of newspaper to
establish a draft.
•If the flame is not getting enough air, a small crack in
the door is all that is needed.
• Open the bypass (pg. 18).
• Open the air control (pg. 20).
• Not enough starter paper - use additional newspaper if
necessary.
•If the flame is not getting enough air, a small crack in
the door is all that is needed.
• Open the bypass before opening the door (pg. 18).
• Open the air control before opening the door (pg. 20).
• Let the air stabilize before fully opening the door. Then
open the door approximately 1 inch. Let air go into the
firebox for a few seconds. Once the smoke appears to
be flowing up the chimney consistently, open the door.
•Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases a
small amount of smoke may enter the home. Adding
more pipe or a draft-inducing cap may help.
Stove Does Not Burn Hot Enough
Blower Does Not Run
Stove Does Not Burn Long
Enough
•Wood is Wet - see the section "Selecting Wood" on
page 22 for details on wood.
•Make sure the air control is all the way open. Slide the
control back and forth to insure the control is not stuck.
•Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases
the fire may burn slowly. Adding more pipe or a draftinducing cap may help.
•Stove is Not Up to Temperature - This is normal. The
blower will come on when the stove is hot - usually 15
to 30 minutes.
•Electricity is Cut to the Blower - Check the household
breaker or fuse to make sure it is operable.
•Depending upon wood, draft, and other factors, the
burn time may be shorter then stated. Make sure the
doors are sealing and not allowing air into the firebox See the section "Door and Glass Inspection" on page
25 for details.
•Check the ash bed for coals. Often, coals are still
glowing under a slight bed of flyash. By raking these
into a pile you can re-start your stove quickly.
Failure to properly maintain and inspect your appliance may reduce the performance and life of the
appliance, void your warranty, and create a fire hazard.
Daily Maintenance (while stove is in use)
Remove Ash (if necessary)
•Ash removal is not required once it builds up. 1/2" to 1" of ash may be desirable because it slows the
burn rate. Generally, remove ash once it has built up over 1". Follow the directions below to remove
ash.
1 Let the stove cool completely (at least two hours after the last coal has extinguished).
2 Place a cloth or cardboard protector over the hearth to catch ash and protect against
scratching.
3 Open the doors and scoop the ash into a metal container with a tight fitting lid. The
closed container of ashes should be placed on a noncombustible floor or on the
ground, away from all combustible materials, pending final disposal.
Improperly disposed ashes lead to fires. Hot ashes placed in cardboard boxes, dumped in back yards,
or stored in garages, are recipes for disaster.
Wood-burning stoves are inherently dirty. During cleaning have a vacuum ready to catch spilled ash
(make sure ash is entirely extinguished).
There are vacuum cleaners specifically made to remove ash (even if the ash is warm). Contact your
dealer for details.
ASHES
Clean the Glass (if necessary)
This appliance has an airwash to keep the glass clean. However, burning un-seasoned wood or burning
on lower burn rates leads to dirtier glass (especially on the sides). Clean the glass by following the
directions below.
Allow the stove to fully cool. Apply glass
cleaner or soapy water to the inside of
the glass. Wipe with newspaper or a
paper towel.
For Stubborn Creosote:
Dip newspaper or a paper towel in cool
ashes and wipe it on the glass. The ash
acts as a light abrasive.
The glass will develop a very slight haze over time. This is normal and will not affect viewing of the fire.
Make sure the appliance has fully cooled prior to conducting service.
Door and Glass Inspection
The door must form an air-tight seal to the firebox for the stove to work correctly. Inspect the door gasket
to make sure it forms an air-tight seal to the firebox.
The door can be lifted off the hinges if extensive repairs are conducted.
High-Temperature anti-sieze
may be used on the door
hinges to eliminate squeaks.
If the glass is damaged, replace
it - see “Replacement Parts” for
details.
Use wood stove gasket
cement to re-adhere
loose gasket.
Severely frayed or thread-bare
gasket should be replaced.
The door latch should pull the door against the face of the stove (but not so tight as to not allow full
handle rotation). If the latch requires adjustment, follow the directions below.
Side View of Door Handle
Door Cam
Washers
Door Frame
Door
Handle
Use a 9/16"
socket wrench to
remove this nut.
Exploded View
Door Cam Adjustment:
To tighten, remove
a washer from the
inside of the door
frame. To loosen,
place an additional
washers on the
inside of the door
frame or loosen
the nut 1/2 turn.
Creosote - Formation and Need for Removal
When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled
moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slowburning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote
makes an extremely hot fire. The chimney and chimney connector should be inspected at least once
every two months during the heating season to determine if a creosote buildup has occurred. If creosote
has accumulated, it should be removed to reduce the risk of a chimney fire.
If you are not certain of creosote inspection, contact your dealer or local chimney sweep for a full
inspection. Excess creosote buildup may cause a chimney fire, that may result in property damage,
injury, or death.
Make sure the appliance has fully cooled prior to conducting service.
Touch Up Paint
Included with the owner's pack of this appliance is a can of Stove-Brite®
paint. To touch up nicks or dulled paint, apply the paint while the appliance is
cool. Sand rusted or damaged areas before preparation (use 120 grit
sandpaper). Clean and dry the area to prepare the surface. Wait at least one
hour before starting the appliance. The touched up area will appear darker
than the surrounding paint until it cures from heat. Curing will give off some
fumes while curing – open windows to ventilate.
Cleaning the Air Duct and Blower (if applicable)
Use a vacuum to clean the air ducts (channels). This prevents dust from burning and creating odors.
The optional blower should be vacuumed every year to remove any buildup of dust, lint, etc.
Touch-Up
Pai nt
BOTTOM OF
STOVE
Use a vacuum cleaner to remove any
buildup on the screens of the blower.
Firebrick and Baffle Inspection
Use the illustration on page 28 as a reference for checking the following items. Make sure the appliance
is cool before proceeding.
Baffle Firebricks - check the bricks along the ceiling of the firebox to make sure they are intact and have
no gaps between them. Slide the bricks to eliminate any gaps.
Baffle Supports - make sure the front and back baffle supports in are place and not degraded. Slight
scaling or rusting of the metal is normal.
Secondary Air Tubes - Check the two air tubes and collars to make sure they are intact and not severely
deteriorated. Slight scaling or rusting of the metal is normal. Make sure the push pins hold the air tubes
in place.
Floor and Wall Firebricks - replace any severely damaged firebrick along the side or floor of the firebox.
NOTE: Place the glass gasket around the
perimeter of the door retainer.
NOTE: Glue the door gasket
to the door retainer.
1
2
3
4
5
6
9
10
11
9/16" Wrench
ID #DescriptionQtyPart #ID #DescriptionQtyPart #
1Door Shell - Black
Door Shell - Brass
Door Shell - Pewter
3Glass Gasket1100-011644Door Retainer (w gasket)1224-23029
5Gasket Cement1999004096Door Gasket199900406
7Door Handle Asbly - Black
Door Handle Asbly - Brass
Door Handle Asbly - Pewter
9Washers2100-0350110Cam199900417
11Nut, Brass1101-0000712Glass Clips - Top
13#8-32 3/8" Type F Screw8225-2003914Set Screw2225-20038
1230-00578
230-00579
230-00577
1224-14042
99900410
224-14052
2Glass (19-1/4" x 9-7/8")1173-01001
8Spring - Black
Spring - Brass
Spring - Pewter
Glass Clip - Bottom
1100-14122
2
1
99300100
100-04103
224-230022
224-230021
Replacing the Glass
The glass must not contact the door retainer or glass clips directly. The glass gasket and glass clip
gaskets insulate the glass to prevent cracking. Do not over-tighten the glass clips.
See "Door Shell Installation" (pg. 32) for details on removing the door handle and shell. NOTE: The glass
gasket is placed in the grove along the inside perimeter of the door retainer. Make sure the glass clip
screws are all fully tightened - they must be flush with the door retainer for the door shell to install.
Replacing the Door Gasket
The door gasket inserts into the outer groove of the door retainer. Stove gasket cement holds it in place.
Before installing, remove any residual cement. Lay the gasket in place (start at the lower left corner) and
cut off any excess gasket (do not stretch the gasket. The cement fully cures with heat from the stove.
You may need to open and close the door repeatedly to get the gasket to seat fully.
Replacing the Door Handle
See the illustration above for a component list (see pg. 25 for details on adjusting the door).
To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase
date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this gas appliance (appliance is
defined as the equipment manufactured by Travis Industries, Inc.) to be defect-free in material and workmanship to the original purchaser from the date of
purchase as follows:
Check with your dealer in advance for any costs to you when arranging a warranty call.
Mileage or service charges are not covered by this warranty. This charge can vary from store to store.
Years 1 & 2 - COVERAGE: PARTS & LABOR
Firebox Assembly:
Firebox, Baffle Supports, Air Tubes, Air Channels, Convection Chamber
Door Assembly:
Solid Brass or Cast Door, Latch Assembly, Glass Retainers
1. This new appliance must be installed by a qualified installer. It must be installed, operated, and maintained at all times in accordance with the instructions in the
Owner’s Manual. Any alteration, willful abuse, accident, neglect, or misuse of the product shall nullify this warranty.
2. This warranty is nontransferable, and is made to the ORIGINAL purchaser, provided that the purchase was made through an authorized Travis dealer.
3. Discoloration and some minor expansion, contraction, or movement of certain parts and resulting noise, is normal and not a defect and, therefore, not covered
under warranty. Over-firing (operation where the steel may glow red) of this appliance can cause serious damage and will nullify this warranty.
4. The warranty, as outlined within this document, does not apply to the chimney components or other Non-Travis accessories used in conjunction with the
installation of this product. If in doubt as to the extent of this warranty, contact your authorized Travis retailer before installation.
5. Travis Industries will not be responsible for inadequate performance caused by environmental conditions such as nearby trees, buildings, roof tops, wind, hills or
mountains or negative pressure or other influences from mechanical systems such as furnaces, fans, clothes dryers, etc.
6. This Warranty is void if:
a. The unit has been operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals.
b. The unit is subject to submersion in water or prolonged periods of dampness or condensation.
c. Any damage to the unit, combustion chamber, heat exchanger or other components due to water, or weather damage which is the result of, but not
7. Exclusions to this 7 Year Warranty include: injury, loss of use, damage, failure to function due to accident, negligence, misuse, improper installation, alteration or
8. This 7 Year warranty excludes damage caused by normal wear and tear, such as paint discoloration or chipping, worn or torn gasketing, chipped or cracked
9. Damage to brass or plated surfaces caused by fingerprints, scratches, melted items, or other external sources left on the surfaces from the use of abrasive
10. TRAVIS INDUSTRIES, INC. is free of liability for any damages caused by the appliance, as well as inconvenience expenses and materials. Incidental or
11. This warranty does not cover any loss or damage incurred by the use or removal of any component or apparatus to or from the Travis appliance without the
12. Any statement or representation of Travis products and their performance contained in Travis advertising, packaging literature, or printed material is not part of
13. This warranty is automatically voided if the appliance’s serial number has been removed or altered in any way. If the appliance is used for commercial purposes,
14. No dealer, distributor, or similar person has the authority to represent or warrant Travis products beyond the terms contained within this warranty. TRAVIS
15. Travis Industries will not cover the cost of the removal or re-installation of hearths, facing, mantels, venting or other components.
16. If for any reason any section of this warranty is declared invalid, the balance of the warranty remains in effect and all other clauses shall remain in effect.
17. This 7 year warranty is the only warranty supplied by Travis Industries, Inc., the manufacturer of the appliance. All other warranties, whether express or implied,
limited to, improper chimney/venting installation.
adjustment of the manufacturer's settings of components, lack of proper and regular maintenance, damage incurred while the appliance is in transit, alteration, or
act of God.
firebrick, etc. Also excluded is damage to the unit caused by abuse, improper installation, modification of the unit, or the use of fuel other than that for which the
unit is configured (use cord wood only).
cleaners is not covered in this warranty. Damage to the surfaces from over-firing (operation where the steel may glow red) is not covered in this warranty.
consequential damages are not covered by this warranty. In some states, the exclusion of incidental or consequential damage may not apply.
express written permission of TRAVIS INDUSTRIES, INC. and bearing a TRAVIS INDUSTRIES, INC. label of approval.
this 7 year warranty.
it is excluded from this warranty.
INDUSTRIES, INC. assumes no liability for such warranties or representations.
are hereby expressly disclaimed and purchaser’s recourse is expressly limited to the warranties set forth herein.
IF WARRANTY SERVICE IS NEEDED:
1. If you discover a problem that you believe is covered by this warranty, you MUST REPORT it to your Travis dealer WITHIN 30 DAYS, giving them proof of
purchase, the purchase date, and the model name and serial number.
2. Travis Industries has the option of either repairing or replacing the defective component.
3. If your dealer is unable to repair your appliance’s defect, he may process a warranty claim through TRAVIS INDUSTRIES, INC., including the name of
the dealership where you purchased the appliance, a copy of your receipt showing the date of the appliance’s purchase, and the serial number on your
appliance. At that time, you may be asked to ship your appliance, freight charges prepaid, to TRAVIS INDUSTRIES, INC. TRAVIS INDUSTRIES, INC.,
at its option, will repair or replace, free of charge, your appliance if it is found to be defective in material or workmanship within the time frame stated
within this 7 year warranty. TRAVIS INDUSTRIES, INC. will return your appliance, freight charges (years 1 to 5) prepaid by TRAVIS INDUSTRIES,
INC., to your regional distributor, or dealership.
4. Check with your dealer in advance for any costs to you when arranging a warranty call. Mileage or service charges are not covered by this warranty. This charge
can vary from store to store.
Ceramic Glass
Glass (breakage from thermal shock)
Re-Installation Allowance
Firebrick
Breakage from thermal shock
One-Way Freight Allowance
Accessories
Legs, Pedestal, Panels, Blower
Door Assembly:
Solid Brass or Cast Door, Latch
Assembly, Glass Retainers
Door Assembly:
Solid Brass or Cast Door, Latch Assembly, Glass Retainers
In cases where heater must be removed from home
for repairs, a partial cost of re-installation is covered
(pre-authorization required)
One-way freight allowance on pre-authorized repair
done at factory is covered.
One-Way Freight Allowance
One-way freight allowance on pre-authorized
repair done at factory is covered.
TESTED TO RELEVANT PORTIONS OF
UL 1482, 737 AND 907.
SERIAL
NUMBER
PREVENT HOUSE FIRES - Install and use only in accordance with the Lopi Liberty (520-NT) owner’s manual. Contact your
local building or fire officials about restrictions and installation inspection in your area. Refer to local building codes and
the chimney manufacturer’s instructions for precautions required for passing a chimney through a combustible wall or ceiling. Do not run a chimney connector through a combustible wall or ceiling. Do not connect this unit to a chimney flue serving another appliance. Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or
other means approved by local building or fire officials.
FREESTANDING INSTALLATION
STANDARD RESIDENTIAL FREESTANDING INSTALLATIONS REQUIRE: 6” diameter, minimum 24 MSG black or 25 MSG
blued steel connector, with listed (type HT) factory-built chimney, suitable for use with solid fuels or masonry chimney.
Pedestal or legs are required.
ALCOVE INSTALLATIONS REQUIRE: One of the listed doublewall connectors shown below. Pedestal or legs are required.
Maximum alcove depth 48”, minimum alcove height 84”.
MOBILE HOME AND REDUCED CLEARANCE INSTALLATIONS REQUIRE: One of the listed doublewall connectors shown
below. In addition, mobile home installations require outside air - use the optional pedestal or outside air boot. Pedestal or
legs are required.
• DURAVENT model DVL with DURA-PLUS chimney
• AMERI-TEC model DCC with model HS chimney
• SECURITY model DP with SECURITY model ASHT or S2100 chimney
Replace glass only with LOPI supplied NEOCERAM ceramic
CLEARANCES AND
FLOOR PROTECTION
REQUIREMENTS:
STANDARD RESIDENTIAL
INSTALLATION (SINGLEWALL
A. SIDEWALL TO UNIT
B. BACKWALL T O UNIT
C. CORNER TO UNIT
D. SIDEWALL TO CONNECTOR
E. BA CKWALL T O CONNECTOR
F .CORNERW ALL TO CONNECTOR
For use with solid wood fuels only (cord wood). Operate with
feed door closed - open to feed fire only. Do not use a grate
or elevate fire - build fire directly on the hearth.
Manufactured by:
By:
4800 Harbour Pointe Blvd. SW Mukilteo,
• METALFAB model DW connector with TG chimney
• Standard Masonry Chimney with any one of the above listed connectors
The indent on the door retainer slides into
the clip on the door shell (on both sides).
Page 33
Optional Equipment33
3 Attach the retainer to the shell following the directions below.
Make sure the door retainer is centered on the door shell.
You can gauge the alignment by looking at the gaps here.
1/8” Hex Wrench
Once the door is aligned, tighten
the two set screws on the bottom
of the door shell to secure the
door retainer.
4 Attach the door handle
following the directions to
the right.
5 Replace the door on the
hinges and latch the door.
6 Attach the ashlip trim
following the directions
below.
NOTE: in rare cases the door retainer may not line up with
the door shell, preventing the door handle from lining up
correctly. To adjust the position horizontally, loosen the set
screws (see step 3) and adjust the door retainer position. To
adjust vertically, remove the retainer and adjust the clips on
the door shell (see step 2).
Slide the ashlip trim into place then tighten the three
set screws on the bottom of the ashlip to secure.
Page 34
34Optional Equipment
Stove Leg Installation
Part Numbers: Brass # 99200500, Cast Black # 99200800, Black Steel # 99200100
•Raise the stove 8" (use lumber). Attach each leg following the instructions below.
Attach each leg to the stove by
inserting a bolt and washer through the
hole or slot in the leg and into the
threaded hole on the stove.
These rubber-tipped bolts are for leveling the stove.
Make sure they contact the floor. Do not adjust
with weight on the legs, the rubber tips may tear.
If using outside air with the pedestal, follow the directions below under "Using Outside Air with the
Pedestal" prior to installing the pedestal.
Attachment Bolts and
Washers - use a 9/16"
socket wrench to
attach the pedestal to
the stove.
23 5/8”
Optional Equipment35
Optional Air
Intake Port
If installing in a mobile home,
insert the lag bolts through
these holes and screw them
into the floor with a 1/2" socket
wrench.
22”
When attached, the faceplate of
the stove is 4 3/4” in front of the
front edge of the pedestal.
OUTSIDE AIR EQUIPMENT
Insulation is
used to seal
the side edges
of the pedestal
.
Screen is used
to prevent
rodents from
entering.
Staples are
used to attach
the screen to
the floor.
The cover plate is used
to seal off room air.
Using Outside Air with the Pedestal
Before installing, check the section "Outside Air Requirements" 11 for installation concerns.
1. Determine the location of the outside air hole penetrating the floor (& hearth). The illustration
above details the size of pedestal and its location in relation to the stove. The hole may be cut
anywhere underneath the pedestal, as long as it is not within 2" of the outside perimeter of the
pedestal, is at least 16 square inches in area, and does not interfere with structural members of
the home. Place the rodent screen over the hole (above or below) and secure with staples.
2. Attach the stove to the pedestal with the included bolts. Tuck the included insulation underneath
the side edges of pedestal to seal off any air from entering underneath the pedestal.
The rear blower improves heat transfer by pushing heated air through the convection channel. Operating
instructions are described in the section "Blower Operation".
1 The stove should be in place with the legs installed prior to installing the rear blower.
2 Follow the directions below to install the blower. Use the
Use the wire clip to insure the wires from the thermodisk are held in place away from the firebox (this
prevents damage to the wires).
Thermodisk
Wire Clip
Blower Box
This portion
hooks on the
top edge of the
rear heat shield.
This portion of the wire
clips slides over the
rear heat shield
The wires pass through the eye of the wire clip.
The two yellow wires
attach to the thermodisk.
Three holes for
attaching the
blower box to the
back of the stove
Slide the
thermodisk
assembly into
the space
between the
stove and rear
heat shield.
Run both of the
wires from the
thermodisk down
behind the stove
and through the
eye of the wire clip.
Outside Air Boot Installation (Part number 99200134)
The outside air boot routes outside air to the stove for combustion. Refer to the section "Outside Air
Requirements" for installation concerns. The directions below detail installation.
1 Refer to the illustration below to determine the location and size of the hole penetrating the floor
and hearth. The knock-out (which is pre-removed) is 6-11/16" behind the face of the stove. Cut the
hole prior to locating the stove.
2 Attach gasket to the bottom edge of the lower air boot section (near the screen). Attach gasket
on top of the flanges on the upper air boot section. Slide the two sections together with both
seams facing the rear (do not attach the two sections at this time).
3 Follow the directions below for attaching the upper section of the air boot (with gasket) to the
stove.
4 Slide the lower section down until it contacts the hearth. Attach the two sections together
following the directions below
Use a
Bottom of Stove
Attach the included
gasket to all four top
edges of the air boot.
screwdriver to
pry out the
knock-out (if
applicable).
Attach gasket to the bottom
edge of the air boot.
8-7/8”
Floor (and hearth)
5-1/8”
Attach the air boot with
the two screws included
with the kit.
1/4" Nutdriver
Use the included screws to attach
the two telescoping portions of air
boot together. The included drill bit
should be used to drill the hole.
Make sure the air boot is expanded
to the correct size before drilling.
9/64” Drill Bit
The hole in the floor (and hearth)
must be a minimum 16 square
inches. It should be 1/2” smaller
than the footprint of the air boot in
each dimension to allow for the
gasket to seal.