2 Introduction
Introduction
We welcome you as a new owner of a Lopi Liberty wood-burning stove. In purchasing a Lopi Liberty you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. The Lopi Liberty is one of the finest appliances the world over. This manual will explain the installation, operation, and maintenance of this appliance. Please familiarize yourself with the Owner's Manual before operating your appliance and save the manual for future reference. Included are helpful hints and suggestions which will make the installation and operation of your new appliance an easier and more enjoyable experience. We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your appliance.
Important Information
No other Lopi Liberty appliance has the same serial number as yours. The serial number is stamped onto the label on the back of the appliance.
Mail your Warranty Card Today, and Save Your Bill of Sale.
This serial number will be needed in case you require service of any type.
Model: Lopi Liberty
Serial Number:
Purchase Date:
Purchased From:
To receive full warranty coverage, you will need to show evidence of the date you purchased your appliance. Do not mail your Bill of Sale to us.
We suggest that you attach your Bill of Sale to this page so that you will have all the information you need in one place should the need for service or information occur.
© Travis Industries 100-01164 4041115
Page 3
Table of Contents 3
General Information
Introduction & Important Information...................... 2
Safety Precautions ............................................ 4
Features & Specifications.................................... 6
Stove Installation
Planning The Installation..................................... 7
Floor Protection Requirements ............................. 8
Stove Placement Requirements ........................... 8
Clearances ...................................................... 8
Chimney Requirements ...................................... 10
Chimney Termination Requirements...................... 11
Outside Air Requirements ................................... 11
Alcove Installation Requirements .......................... 12
Mobile Home Requirements ................................ 13
INSTALLATION DIAGRAMS
Standard Ceiling with a Factory Built Chimney......... 14
Cathedral Ceiling with a Factory Built Chimney........ 14
Exterior Factory Built Chimney ............................. 15
Hearth Stove Positive Connection......................... 15
Hearth Stove Direct Connection ........................... 16
Interior Masonry Chimney ................................... 16
Maintaining Your Appliance
Daily Maintenance ............................................. 24
Remove Ash .................................................... 24
Clean The Glass ............................................... 24
Monthly Maintenance ......................................... 25
Door and Glass Inspection .................................. 26
Check For Creosote Buildup ................................ 25
Yearly Maintenance ........................................... 26
Touch Up Paint ................................................. 26
Blower Cleaning................................................ 26
Firebrick and Baffle Inspection ............................. 26
Door Parts ....................................................... 27
Replacing the Glass........................................... 27
Replacing the Door Gasket.................................. 27
Replacing the Door Handle.................................. 27
Firebox Parts.................................................... 28
Floor & Side Firebrick Removal & Replacement....... 28
Baffle Removal and Replacement ......................... 29
Air Tube Removal and Replacement ..................... 29
Warranty
Warranty ......................................................... To
Operating Your Appliance
Safety Notice.................................................... 17
Before Your First Fire ......................................... 17
Opening the Door .............................................. 17
Bypass Operation.............................................. 18
Starting a Fire................................................... 19
Adjusting the Burn Rate ...................................... 20
Ash Removal.................................................... 20
Optional Blower Operation .................................. 21
Re-Loading the Stove......................................... 21
Overnight Burn ................................................. 21
Normal Operating Sounds ................................... 21
Hints for Burning ............................................... 22
Selecting Wood................................................. 22
Troubleshooting ................................................ 23
Listing Information
Listing Information ............................................. 31
Optional Equipment
Door Shell Installation ........................................ 32
Stove Legs....................................................... 34
Pedestal .......................................................... 35
Rear Blower Installation ...................................... 36
Outside Air Boot Installation................................. 37
Index
Index .............................................................. 38
© Travis Industries 100-01164 4041115
Page 4
4 Safety Precautions
The viewing door must be closed and latched during operation.
Never block free airflow through the air vents on this appliance.
This appliance is designed and approved for the burning of cord wood only. Do not attempt to burn any other type of fuel other than cord wood in this appliance, it will void all warranties and safety listings.
Do not touch the appliance while it is hot and educate all children of the danger of a high­temperature appliance. Young children should be supervised when they are in the same room as the appliance.
36"
Gas
ASHES
Gasoline or other flammable liquids must never be used to start the fire or "Freshen Up" the fire. Do not store or use gasoline or other flammable liquids in the vicinity of this appliance.
Ashes must be disposed in a metal container with a tight lid and placed on a non­combustible surface well away from the home or structure.
Keep furniture, drapes, curtains, wood, paper, and other combustibles a minimum of 36" away from the front of the appliance.
This appliance must be properly installed to prevent the possibility of a house fire. The instructions must be strictly adhered to. Do not use makeshift methods or compromise in the installation.
Inspect the chimney connector and chimney at least twice monthly and clean if necessary. Creosote may build up and cause a house fire.
Do not connect this appliance to any chimney serving another appliance.
Type
HT
Ok
Clay
Liner
Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirements in your area. Notify your insurance company of this appliance as well.
This appliance must be connected to a listed high temperature (UL 103 HT) residential type chimney or an approved masonry chimney with a standard clay tile, or stainless steel liner.
© Travis Industries 100-01164 4041115
Page 5
Mobile
Home
Safety Precautions 5
When installed in a mobile home, this appliance must be bolted to the floor, have outside air, and not be installed in the bedroom (Per H.U.D. requirements). Check with local building officials.
Do not place clothing or other flammable items on or near this appliance.
Never try to repair or replace any part of this appliance unless instructions are given in this manual. All other work must be done by a trained technician.
Allow the appliance to cool before carrying out any maintenance or cleaning.
Maintain the door and glass seal and keep them in good condition.
Avoid placing wood against the glass when loading. Do not slam the door or strike the glass.
Do not make any changes or modifications to an existing masonry fireplace or chimney to install this appliance.
Do not make any changes to the appliance to increase combustion air.
Overfiring the appliance may cause a house fire. If a unit or chimney connector glows, you are overfiring.
Do not use a grate or other device to elevate the fire off of the firebox floor. Burn the fire directly on the bricks.
Do not throw this manual away.
This Manual
This manual has important operating and maintenance instructions that you will need at a later time. Always follow the instructions in this manual.
© Travis Industries 100-01164 4041115
Travis Industries, Inc. grants no warranty, implied or stated, for the installation or maintenance of your appliance, and assumes no responsibility of any consequential damage(s).
Page 6
6 Features & Specifications
Installation Options
Freestanding
Freestanding in an Alcove
Freestanding in a Mobile Home
Freestanding Hearth Stove
Features
EPA Phase II Approved
3.1 Cubic Foot Firebox Volume
Single Operating Control
Accepts Logs Up to 24" Long
Steel Plate Construction (5/16" & 3/16")
Heavy Duty Refractory Firebrick
Optional High-Tech Blower
Heating Specifications
Approximate Maximum Heating Capacity (in square feet)* 1,500 to 2,500
Maximum BTU's per Hour (Cord Wood Calculation) 74,300
Overall Efficiency (Oregon Method) 70 %
Maximum Burn Time Up to 12 Hours
* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is also affected by the quality and moisture level of the fuel.
Dimensions
30”
Weight: 470 Lbs.
21”
6-1/4
The 6 diameter flue collar protrudes 1-1/4" above the stove top
Note: Measure side, corner, and back clearances from the stove top. Measure front clearances from the stove face.
Height:
Sculptured or Cast Legs....32-1/4"
Pedestal.............................36-1/4"
Emissions
2.6 Grams Per Hour (EPA Phase II Approved) – Tests conducted by E.E.S.P.C.
© Travis Industries 100-01164 4041115
Figure 1
Page 7
Stove Installation (for qualified installers only) 7
SAFETY NOTICE:
Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death. Contact local building or fire officials about restrictions and installation inspection requirements in your area.
Planning The Installation
We suggest that you have an authorized Travis Industries dealer install your stove. If you install the stove yourself, your authorized dealer should review your installation plans.
Check with local building officials for any permits required for installation of this stove and notify your insurance company before proceeding with installation.
Preparation for Installation
Check for damage to the exterior of the stove (dents should be reported, scratches can be fixed by
applying touch up paint).
Check the interior of the firebox (replace cracked firebrick and make sure baffle is in place).
The stove can be lightened by removing the firebricks and baffle (pg 28) - replace before operation.
Additional Accessories Needed for Installation
Door Shell (Black 99300165 Brass 99300166 - see pg 32)
Legs or Pedestal
Stove Installation Considerations
The table below details the six most common types of installations and the considerations for each type. Alternative methods of installation are available if they comply with local building codes.
Installation Type Considerations
Standard Ceiling with a Factory Built Chimney (Page 14)
Cathedral Ceiling with a Factory Built Chimney (Page 14)
Exterior Factory Built Chimney (Page 15)
Hearth Stove Positive Connection (Page 15)
Hearth Stove Direct Connection (Page 16)
Interior Masonry Chimney (Page 16)
Requires ceiling and roof penetration
Provides best draft
Cathedral style chimney support required
Provides best draft
Uses two elbows to route chimney outside
Exterior chimney is hidden from the room
Elbows reduce draft
Optional exterior chase reduces cold air blockage
Utilizes existing masonry or zero clearance (metal) chimney
Provides good draft due to full reline
Easier to clean than direct or horizontal hearth stove
Utilizes existing masonry or zero clearance (metal) chimney
Requires construction of a "block-off plate"
Draft reduced due to elbows & chimney cross section
Utilizes existing masonry chimney (not approved for zero
clearance (metal) fireplaces)
© Travis Industries 100-01164 4041115
Page 8
8 Stove Installation (for qualified installers only)
Floor Protection Requirements
Stove must be placed on the Travis Industries legs or Pedestal.
Floor protection must extend 6" to the sides and rear of the stove and 16" to the front of the stove
(42" wide by 43" deep - see Figure 2 and Figure 3).
Floor protection must be non-combustible and at least .018" thick (26 guage).
Stove Placement Requirements
Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or other means approved by local building or fire officials.
Stove must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors), 36"
of the front of the stove
If the stove is placed in a location where the ceiling height is less than 7', it must follow the
requirements in the section "Alcove Installation Requirements"
Must maintain the clearances to combustibles listed below (drywall, furniture, etc.):
Clearances
The following clearances must be met (see Figure 2 and Figure 3)
Minimum Clearance Singlewall
Connector
A Sidewall to stove 16" 16"
B Backwall to stove 15” 10"
C Cornerwall to stove 9-1/2" 7-1/2"
D Connector to sidewall 28" 27-1/2"
E Connector to backwall 18-1/4" 12-3/4"
F Connector to cornerwall 21" 18-1/2"
*Reduced clearance installations require one of the chimneys and connectors listed below:
AMERI-TEC model DCC with model HS chimney DURAVENT model DVL with DURATEC or DURA-PLUS chimney I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector METALFAB model DW connector with TG chimney SECURITY model DP connector with SECURITY model ASHT or S2100 chimney Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.
NOTE: Standard residential installations with reduced clearance connector may use the clearance determined by the manufacturer of the connector for the connector to wall clearance or the clearance
listed in this manual. Offsets must be used to maintain the stove to wall clearance.
Reduced Clearance*
© Travis Industries 100-01164 4041115
Page 9
Stove Installation (for qualified installers only) 9
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Top View ­Straight Installation
Back Wall
Clearance B
Clearance E
Top View ­Corner Installation
AAAAAAAAAAA
30”
AAAAAAAAAAA
6-1/4”
AAAAAAAAAAA
6” Min.
6” Min.
AAAAAAAAAAA AAAAAAAAAAA
21”
AAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAAA
16” Min.
AAAAAAAAAAA AAAAAAAAAAA
Floor Protection
Side Wall
Clearance A
Clearance D
Measure rear and side
clearances from the nearest
edge of the stove top.
NOTE: vent diameter may
vary depending on brand
and model.
Measure front clearances
from the face of the stove
(unibody).
Figure 2
© Travis Industries 100-01164 4041115
6” Min.
Corner Wall
Clearance C
6” Min.
Corner Wall
Clearance F
AAAAAAAAAAAAA AAAAAAAAAAAAA
6-1/4”
30”
AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA
21”
AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA
16” Min.
AAAAAAAAAAAAA AAAAAAAAAAAAA
Floor Protection
Measure rear and side
clearances from the nearest
edge of the stove top.
NOTE: vent diameter may
vary depending on brand
and model.
Measure front clearances
from the face of the stove
(unibody).
Figure 3
Page 10
10 Stove Installation (for qualified installers only)
A
Chimney Requirements
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
Chimney connector must be a minimum 24 MSG black or 26 MSG blued steel (6" diameter). Chimney
must be used from the first floor or wall penetration to the chimney cap.
Use 6" diameter type UL 103 HT chimney from one manufacturer (do not mix brands) or code
approved masonry chimney with a flue liner.
Chimney connector and chimney must be fastened to the stove and each adjoining section.
Follow the chimney manufacturer's clearances and requirements.
Use the chimney manufacturer's fire stops, attic guards, roof supports, and flashings when passing
through a ceiling or thimble when passing through a combustible wall.
No more than 180
NOTE: Additional elbows may be allowed if draft is sufficient. Whenever elbows are used the draft is
adversely affected. Additional chimney height may be required to boost draft.
(See the section "Chimney Termination
Requirements" for more details)
Factory Built Chimney Sections
Floor Penetration Equipment
(Attic Radiation Shield with Chimney Support)
o
of elbows (two 90o elbows, or two 45o & one 90o elbow, etc.).
Chimney Cap
Roof Penetration Equipment (Roof Radiation Shield, Flashing, Storm Collar)
}
Minimum Air Space to Combustibles (See Chimney Manufacturer's Instructions - usually 2")
Minimum System 15' Maximum System 33'
}
Standard residential installations with reduced clearance connector may use the clearance determined by
Reduced Clearance Chimney
Connector Sections
}
Floor Protection
Drafting Performance
Standard residential installations may use single-wall connector (Mobile-Homes may not)
Standard residential installations with reduced clearance connector may use the clearance
determined by the manufacturer of the connector for the connector to wall clearance or the clearance listed in this manual. Offsets must be used to maintain the stove to wall clearance. Mobile homes must use the clearances listed in this manual under "Additional Requirements for Mobile Home Installations".
This appliance relies upon natural draft to operate. External forces, such as wind, barometric pressure, topography, or factors of the home (negative pressure from exhaust fans, chimneys, air infiltration, etc.), may adversely affect draft. Travis Industries can not be responsible for external forces leading to less than optimal performance.
the manufacturer of the connector for the connector to wall clearance or the clearance listed in this manual.
Mobile home installations must use the the reduced clearance connector clearances listed in this manual under Additional Requirements for Mobile Home Installations.
Stove Clearance (as outlined in this manual)
Figure 4
© Travis Industries 100-01164 4041115
Page 11
Stove Installation (for qualified installers only) 11
F
Chimney Termination Requirements
Must have an approved cap (to prevent water from entering)
Must not be located where it will become plugged by snow or other material
Must terminate at least 3' above the roof and at least 2' above any portion of the roof within 10' (see
Figure 5)
Slanted Roofs
Chimney must extend 3' above the roof
lat Roofs
Chimney must extend 3' above the roof
Chimney must extend 2' above any portion of the roof within 10' of the chimney
Outside Air Requirements
Required for mobile homes & in certain localities (check with building officials)
Must not be drawn from an enclosed space (garage, unventilated crawl space)
Requires the optional outside air boot (for legs) or pedestal.
Chimney must extend 2' above any portion of the roof within 10' of the chimney
Figure 5
When using outside air, find a location where the chimney and outside air hole do not interfere with structural members of the home.
Pedestal (with insulation) directs air to the stove.
Air may be drawn from a ventilated crawl space or use an air duct.
A hole must be cut through the floor protection and floor and the rodent screen nailed in place here (see the optional equipment instructions for exact sizes)
Optional Air Duct (must not be longer than 15' and at least 16 square inches in cross section)
Outside air entrance must be placed so it does not become blocked by snow.
Outside Air Boot
Figure 6
© Travis Industries 100-01164 4041115
Page 12
12 Stove Installation (for qualified installers only)
Alcove Installation Requirements
Whenever the stove is placed in a location where the ceiling height is less than 7' tall, it is considered an alcove installation. Because of the reduced height, the special installation requirements listed below must be met.
Chimney connector and chimney must be one of the following types:
AMERI-TEC model DCC with model HS chimney DURAVENT model DVL with DURATEC or DURA-PLUS chimney I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector METALFAB model DW connector with TG chimney SECURITY model DP connector with SECURITY model ASHT or S2100 chimney Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.
Alcoves are classified as combustible or non-combustible. Non-combustible alcoves must have walls
and a ceiling that are 3 1/2" thick of a non-combustible material (brick, stone, or concrete - see Figure
7). This non-combustible material must be spaced and ventilated at least 1" off of all combustible materials (walls, ceiling, etc.) to allow air to move around the non-combustible walls and ceiling. All other alcoves are considered combustible. The clearances below must be met:
Minimum Clearance (See the Figure 7 below)
Combustible Alcove
Non-Combustible Alcove
A Sidewall to stove 16" 6" B Backwall to stove 10" 2" D Connector to sidewall 27-1/2" 17-1/2" E Connector to backwall 12-3/4" 4-3/4" G Maximum depth of alcove 48" 48" H Minimum width of alcove 62" 42" J Minimum height of alcove 84" 6" above stove top
Non-combustible alcove construction (on walls and ceiling) - see the explanation above.
Ventilated air space
1" Min.
3 1/2" thick non­combustible material
j
d
e
a
b
Combustible
materials
Non-combustible reinforcer
© Travis Industries 100-01164 4041115
h
g
Figure 7
Page 13
Stove Installation (for qualified installers only) 13
Mobile Home Requirements
Outside air must be installed - see "Outside Air Requirements" on page 11
Chimney connector and chimney must be one of the following types:
AMERI-TEC model DCC with model HS chimney DURAVENT model DVL with DURATEC or DURA-PLUS chimney I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector METALFAB model DW connector with TG chimney SECURITY model DP connector with SECURITY model ASHT or S2100 chimney Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.
Stove placement must maintain the following clearances to combustibles (drywall, furniture, etc.)
Rear heat
b
e
a
d
shield
f
c
c
Measure all clearances from the nearest edge of the stove top.
Minimum Clearance (See the illustration above)
Reduced Clearance Connector
A Sidewall to stove 16" B Backwall to stove 10" C Cornerwall to stove 7-1/2" D Connector to sidewall 27-1/2" E Connector to backwall 12-3/4" F Connector to cornerwall 18-1/2"
If using offsets, use the connector clearance listed in Figure 9,
not the connector manufacturer's clearance.
The appliance must be secured to the floor (consult your
building official). Secure the outside air boot to the floor and stove to insure the stove does not dislocate.
Mobile home installations require a spark arrester at the
chimney termination.
The appliance must be grounded to the chassis of the mobile
home (consult your building official).
WARNING:DO NOT INSTALL IN SLEEPING ROOM.
CAUTION:THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED.
Figure 8
12” Min.
Minimum Connector Clearance (as outlined above)
Minimum Stove Clearance (as outlined above)
Figure 9
© Travis Industries 100-01164 4041115
Page 14
14 Stove Installation (for qualified installers only)
Standard Ceiling with a Factory Built Chimney
Chimney Cap (See the section "Chimney Termination Requirements" for more details)
Chimney Sections
Insulation
Follow the chimney manufacturer's instructions and clearances for floor penetrations. A ceiling support is required, an attic insulation shield is required where insulation is present.
Chimney Connector Sections
Floor Protection (See the section "Floor Protection Requirements" for more details)
}
}
Follow the chimney manufacturer's instructions and clearances for roof penetrations. A storm collar and flashing are required (some require a radiation shield).
Minimum Air Space to Combustibles (See Chimney Manufacturer's Instructions - usually 2")
Minimum 15' Maximum 33'
Stove Clearances (See the section "Stove Placement Requirements" for more details)
Cathedral Ceiling with a Factory Built Chimney
Chimney Cap (See the section "Chimney Termination Requirements" for more details)
Chimney Sections
Minimum Air Space to Combustibles (See Chimney Manufacturer's Instructions ­usually 2")
Chimney Connector Sections
Floor Protection (See the section "Floor Protection Requirements" for more details)
}
Figure 10
Follow the chimney manufacturer's instructions and clearances for roof penetrations. A storm collar, flashing, and cathedral-style chimney support are required (some require a radiation shield).
Minimum 15' Maximum 33'
Stove Clearances (See the section "Stove Placement Requirements" for more details)
© Travis Industries 100-01164 4041115
Figure 11
Page 15
Stove Installation (for qualified installers only) 15
C ( T f
M C C I
Exterior Factory Built Chimney
NOTE:
Exterior chimneys are subject to greater moisture and creosote accumulation due to the lower temperatures. An insulated chase will reduce these accumulations (the proper clearances to the chimney must be maintained).
himney Cap
See the section "Chimney
ermination Requirements"
or more details)
Chimney Sections
inimum Air Space to ombustibles (See himney Manufacturer's
nstructions - usually 2")
Min. 18"
clearance to
ceiling
Chimney Connector Sections
Floor Protection (See "Floor Protection Requirements" for details)
Wall Bands and Supports
}
Minimum 15' Maximum 33'
}
Stove Clearances (See the section "Stove Placement Requirements" for more details)
Follow the chimney manufacturer's instructions and clearances for roof penetrations. A storm collar and flashing are required (some require a radiation shield).
Insulated Tee (with cleanout )
Follow the chimney manufacturer's instructions and clearances for wall penetrations. A wall radiation shield (thimble) is required.
Optional insulated chase
Figure 12
Hearth Stove Positive Connection
NOTE:
Most factory-built chimney manufacturers make stainless steel chimney liners, either flexible or rigid. This provides a wide variety of installation options. Make sure to follow the manufacturer's instructions for installation and support.
NOTE: The entire fireplace and chimney must be clean, undamaged, and meet all local building codes (UBC, etc.). Damage must be repaired prior to installation. The chimney must be 15' to 33' tall.
Combustible Mantle
Min. 18"
Floor Protection (See the section "Floor Protection Requirements" for more details)
Cap and flashing prevents water from entering
The liner must be stainless steel connector or flexible vent. Follow the liner manufacturer's instructions for installation and support.
Airtight Insulated Clean-Out
Remove damper or wire it open
See the section "Stove Placement Requirements" for minimum clearances required.
© Travis Industries 100-01164 4041115
Figure 13
Page 16
16 Stove Installation (for qualified installers only)
Hearth Stove Direct Connection
NOTE:
Direct connections require installation of an airtight, non-combustible block-off plate or damper adapter.
NOTE: The chimney must have a clay
tile liner. If it does not, the installation
must use a positive connection (full
reline). The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes (UBC,
etc.). Damage must be repaired prior
to installation. The chimney must be
15' to 33' tall.
Max. 8
Combustible Mantle
Clay Liner
Stainless steel chimney connector must Extend 1' past the block-off plate or to the flue liner
Airtight Insulated Clean-Out
Interior or Exterior Masonry Chimney
NOTE:
This type of installation requires a UBC approved masonry connector or a factory built (U.L. Listed) wall thimble.
Min. 18"
Floor Protection (See the section "Floor Protection Requirements" for more details)
NOTE: The chimney must have a clay tile liner. If it does not, the installation must use a positive connection (full reline). The entire fireplace and chimney must be clean, undamaged, and meet all local building codes (UBC, etc.). Damage must be repaired prior to installation. The chimney must be 15' to 33' tall.
See the section "Stove Placement Requirements" for minimum clearances required.
Chimney connector sections
Remove damper or wire it open
Block-off plate or damper adapter
See the section "Stove Placement Requirements" for minimum clearances required.
Figure 14
Clay Liner
Min. 18" clearance to ceiling
This type of installation requires a UBC approved masonry connector or a factory built (U.L. Listed) wall thimble.
© Travis Industries 100-01164 4041115
See the section "Floor Protection Requirements"
Make sure the clean-out seals in place.
Figure 15
Page 17
Operating Your Appliance 17
Safety Notice
If this appliance is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.
Read and follow all of the warnings on pages 4 and 5 of this manual.
Before Your First Fire
Verify the Installation Before starting the stove, verify that the stove is properly installed and all of the requirements in this
manual have been followed.
Keep all flammable materials 36" away from the front of the stove (drapes, furniture, clothing, etc.).
Curing the Paint
This heater uses a heat-activated paint that will emit some fumes while starting the first fire. Open doors and windows to the room to vent these fumes. This typically lasts two to four hours. You may also notice oil burning off of the interior of the heater. This rust-stopping agent will soon dissipate.
Door Gasket - The door gasket might adhere to the paint on the front of the heater. Leave the door slightly ajar for the first fire and be careful when opening
the door after the first fire.
2 to 4 hours
Over-Firing the Stove
This stove was designed to operate at a high temperature. But due to differences in vent configuration, fuel, and draft, this appliance can be operated at an excessive temperature. If the stove top or other area starts to glow red, you are over-firing the stove. Shut the air control down to low and allow the stove to cool before proceeding.
Over-firing may lead to damage of plated surfaces. If you are uncertain of over-firing conditions, we suggest placing a stove thermometer (e.g. Rutland® Model 710) directly over the door on the stove top ­temperatures exceeding 800° are generally considered over-firing and will void the warranty.
Opening the Door
Rotate the door handle.
The door becomes hot during use. Use a glove to open the door if the handle is hot.
To prevent smoke from entering the room, open the bypass before opening the door (see following page for directions). You can also open the door a small amount and let air enter the firebox.
© Travis Industries 100-01164 4041115
Swing the door open.
Page 18
18 Operating Your Appliance
Bypass Operation
The bypass controls the flow of smoke inside the heater. When pulled out, smoke goes directly up the flue, creating more draft. When pushed in, the smoke goes around the baffle, utilizing the secondary combustion and making the heater more efficient.
When starting or re-loading, pull the bypass out.
During normal operation, push the bypass in.
Bypass Pulled Out
Use the included pull tool to operate the bypass rod
Used for starting and re-loading
Bypass Pushed In
Used for normal operation
© Travis Industries 100-01164 4041115
Page 19
Operating Your Appliance 19
Starting a Fire
Since the dawn of time man has debated the best way to start a fire. Some use the boy-scout "tee-pee", some prefer the "tic-tac-toe" stack. Either way, review the hints and warnings below to ensure proper fire starting.
Make sure the air control is pushed in and by-pass pulled out. If additional air is needed, open the
doors 1/4" during the first five minutes of start-up.
Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or "freshen up" a fire in this stove. Keep all such liquids well away from the stove while it is in use.
If using a firestarter, use only products specifically designed for stoves - follow the manufacturer's instructions carefully.
If the smoke does not pass up the chimney, ball up one sheet of newspaper, place it in the center of the firebox and light it. This should start the chimney drafting (this eliminates "cold air blockage").
Use plenty of kindling to ensure the stove reaches a proper temperature. Once the kindling is burning rapidly, place a few larger pieces of wood onto the fire.
© Travis Industries 100-01164 4041115
Page 20
20 Operating Your Appliance
Adjusting the Burn Rate
Use the air control slider to control the burn rate of the stove. See the illustration below for details.
Use the air control to change the burn rate.
Low Burn
(air control closed)
High Burn
(air control open)
Approximate Air Control Settings
Overnight Burn Fully out to 9/32" open
Medium Burn 9/32" open to 5/16" open
Medium High Burn 5/16" open to 7/16" open
High Burn 7/16" open to pushed fully in
The air control becomes hot during operation - use gloves or a tool to prevent burns.
The air control may take several minutes to influence the burn rate. When making adjustments, you may wish to let the stove burn for 10 minutes to gauge performance.
Ash Removal
Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, away from all combustible
ASHES
© Travis Industries 100-01164 4041115
materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled.
Page 21
Operating Your Appliance 21
Optional Blower Operation
The blower will turn on once the stove is up to temperature. This is typically 15 to 30 minutes after starting the fire. Follow the directions below to alter the blower speed.
OFF
Turn the dial all the way counter­clockwise until it clicks off.
OFF
HI
LO
BLOWER CONTROL
The high position is all the way counter­clockwise,
HIGH
without clicking off.
OFF
HI
LO
BLOWER CONTROL
LOW
Turn the dial all the way clockwise.
OFF
LO
BLOWER CONTROL
The blower may be used to affect heat output (i.e.: to reduce heat output, turn the blower down).
Route the power cord in a location where it will not come in contact with the appliance or become hot.
Re-Loading the Stove
Follow the directions below to minimize smoke spillage while re-loading the stove.
1 Open the air control (push it in). Open the bypass (pull it out).
2 Open the door slightly. Let the airflow inside the firebox to stabilize before opening the doors fully.
3 Load wood onto the fire.
Overnight Burn
HI
This stove is large enough to accommodate burn times up to eight hours. Follow the steps below to achieve an overnight burn.
1 Move the air control to high burn and let the stove become hot (burn for approximately 15 minutes).
2 Load as much wood as possible. Use large pieces if possible.
3 Let the stove burn on high for 15 minutes to keep the stove hot, then turn the air control to low.
4 In the morning the stove should still be hot, with embers in the coal bed. Stir the coals and load
small pieces of wood to re-ignite the fire, if desired.
Differences if chimney height and draft may lower overall burn times.
Normal Operating Sounds
Creaks and Clicks: The 3/16" and 5/16" steel may creak or click when the stove heats up and cools down - this is normal.
Blower Sounds: The blower will make a slight "humm" as it pushes air through the stove.
Hint:
Make sure the leveling bolts on legs are extended ­preventing the hearth from amplifying any vibrations.
© Travis Industries 100-01164 4041115
Page 22
22 Operating Your Appliance
Hints for Burning
Get the appliance hot before adjusting to low burn
Use smaller pieces of wood during start-up and high burns to increase temperature
Use larger pieces of wood for overnight or sustained burns
Stack the wood tightly together to establish a longer burn
Leave a bed of ashes (1/2" deep) to allow for longer burns
Be considerate of neighbors & the environment: burn dry wood only
Burn small, intense fires instead of large, slow burning fires when possible
Learn your appliance's operating characteristics to obtain optimum performance
Selecting Wood
Dry Wood is Key
Dry wood burns hot, emits less
smoke and creates less creosote.
Wet Wood
Leads To
Dry Wood
Testing Wood Moisture
Split wood stored in a dry area will
be fully dry within a year. This insures dry wood. If purchasing wood for immediate use, test the wood with a moisture meter. Some
Less Heat
More Heat
Leads To
experienced wood burners can measure wood moisture by knocking pieces together and listening for a clear "knock" and not a "thud".
More Smoke and Creostoe
Less Smoke and Creostoe
Why Dry Wood is Key
Wet wood, when burned, must release water stored within the wood. This cools the fire, creates creosote, and hampers a complete burn. Ask any experienced wood burner and he or she will agree: dry wood is crucial to good performance.
Wood Cutting and Storage
Leads To
Leads To
Cut wood to length and chop into quarters.
© Travis Industries 100-01164 4041115
Store the wood off the ground in a covered area. Allow for airflow around the wood to dry the wood.
Air Flow
Air Flow
Air Flow
Page 23
Operating Your Appliance 23
Troubleshooting
Problem Possible Cause
Smoke Enters Room During Start-Up
Kindling Does Not Start - Fire Smolders
Smoke Enters Room While Re­Loading
Open the bypass (pg. 18).
Open the air control (pg. 20).
Cold Air Blockage - burn a piece of newspaper to
establish a draft.
If the flame is not getting enough air, a small crack in
the door is all that is needed.
Open the bypass (pg. 18).
Open the air control (pg. 20).
Not enough starter paper - use additional newspaper if
necessary.
If the flame is not getting enough air, a small crack in
the door is all that is needed.
Open the bypass before opening the door (pg. 18).
Open the air control before opening the door (pg. 20).
Let the air stabilize before fully opening the door. Then
open the door approximately 1 inch. Let air go into the firebox for a few seconds. Once the smoke appears to be flowing up the chimney consistently, open the door.
Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases a small amount of smoke may enter the home. Adding more pipe or a draft-inducing cap may help.
Stove Does Not Burn Hot Enough
Blower Does Not Run
Stove Does Not Burn Long Enough
Wood is Wet - see the section "Selecting Wood" on
page 22 for details on wood.
Make sure the air control is all the way open. Slide the
control back and forth to insure the control is not stuck.
Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases the fire may burn slowly. Adding more pipe or a draft­inducing cap may help.
Stove is Not Up to Temperature - This is normal. The
blower will come on when the stove is hot - usually 15 to 30 minutes.
Electricity is Cut to the Blower - Check the household
breaker or fuse to make sure it is operable.
Depending upon wood, draft, and other factors, the
burn time may be shorter then stated. Make sure the doors are sealing and not allowing air into the firebox ­See the section "Door and Glass Inspection" on page 25 for details.
Check the ash bed for coals. Often, coals are still
glowing under a slight bed of flyash. By raking these into a pile you can re-start your stove quickly.
© Travis Industries 100-01164 4041115
Page 24
24 Maintaining Your Appliance
Failure to properly maintain and inspect your appliance may reduce the performance and life of the appliance, void your warranty, and create a fire hazard.
Daily Maintenance (while stove is in use)
Remove Ash (if necessary)
Ash removal is not required once it builds up. 1/2" to 1" of ash may be desirable because it slows the
burn rate. Generally, remove ash once it has built up over 1". Follow the directions below to remove ash.
1 Let the stove cool completely (at least two hours after the last coal has extinguished).
2 Place a cloth or cardboard protector over the hearth to catch ash and protect against
scratching.
3 Open the doors and scoop the ash into a metal container with a tight fitting lid. The
closed container of ashes should be placed on a noncombustible floor or on the ground, away from all combustible materials, pending final disposal.
Improperly disposed ashes lead to fires. Hot ashes placed in cardboard boxes, dumped in back yards, or stored in garages, are recipes for disaster.
Wood-burning stoves are inherently dirty. During cleaning have a vacuum ready to catch spilled ash (make sure ash is entirely extinguished).
There are vacuum cleaners specifically made to remove ash (even if the ash is warm). Contact your dealer for details.
ASHES
Clean the Glass (if necessary)
This appliance has an airwash to keep the glass clean. However, burning un-seasoned wood or burning on lower burn rates leads to dirtier glass (especially on the sides). Clean the glass by following the directions below.
Allow the stove to fully cool. Apply glass cleaner or soapy water to the inside of the glass. Wipe with newspaper or a paper towel.
For Stubborn Creosote:
Dip newspaper or a paper towel in cool ashes and wipe it on the glass. The ash acts as a light abrasive.
The glass will develop a very slight haze over time. This is normal and will not affect viewing of the fire.
© Travis Industries 100-01164 4041115
Page 25
Maintaining Your Appliance 25
Monthly Maintenance (while appliance is in use)
Make sure the appliance has fully cooled prior to conducting service.
Door and Glass Inspection
The door must form an air-tight seal to the firebox for the stove to work correctly. Inspect the door gasket to make sure it forms an air-tight seal to the firebox.
The door can be lifted off the hinges if extensive repairs are conducted.
High-Temperature anti-sieze may be used on the door hinges to eliminate squeaks.
If the glass is damaged, replace it - see Replacement Parts for details.
Use wood stove gasket cement to re-adhere loose gasket.
Severely frayed or thread-bare gasket should be replaced.
The door latch should pull the door against the face of the stove (but not so tight as to not allow full handle rotation). If the latch requires adjustment, follow the directions below.
Side View of Door Handle
Door Cam
Washers
Door Frame
Door Handle
Use a 9/16" socket wrench to remove this nut.
Exploded View
Door Cam Adjustment:
To tighten, remove a washer from the inside of the door frame. To loosen, place an additional washers on the inside of the door frame or loosen the nut 1/2 turn.
Creosote - Formation and Need for Removal
When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow­burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. The chimney and chimney connector should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred. If creosote has accumulated, it should be removed to reduce the risk of a chimney fire.
If you are not certain of creosote inspection, contact your dealer or local chimney sweep for a full inspection. Excess creosote buildup may cause a chimney fire, that may result in property damage, injury, or death.
© Travis Industries 100-01164 4041115
Page 26
26 Maintaining Your Appliance
Yearly Maintenance
Make sure the appliance has fully cooled prior to conducting service.
Touch Up Paint
Included with the owner's pack of this appliance is a can of Stove-Brite® paint. To touch up nicks or dulled paint, apply the paint while the appliance is cool. Sand rusted or damaged areas before preparation (use 120 grit sandpaper). Clean and dry the area to prepare the surface. Wait at least one hour before starting the appliance. The touched up area will appear darker than the surrounding paint until it cures from heat. Curing will give off some fumes while curing – open windows to ventilate.
Cleaning the Air Duct and Blower (if applicable)
Use a vacuum to clean the air ducts (channels). This prevents dust from burning and creating odors.
The optional blower should be vacuumed every year to remove any buildup of dust, lint, etc.
Touch-Up
Pai nt
BOTTOM OF
STOVE
Use a vacuum cleaner to remove any buildup on the screens of the blower.
Firebrick and Baffle Inspection
Use the illustration on page 28 as a reference for checking the following items. Make sure the appliance is cool before proceeding.
Baffle Firebricks - check the bricks along the ceiling of the firebox to make sure they are intact and have no gaps between them. Slide the bricks to eliminate any gaps.
Baffle Supports - make sure the front and back baffle supports in are place and not degraded. Slight scaling or rusting of the metal is normal.
Secondary Air Tubes - Check the two air tubes and collars to make sure they are intact and not severely deteriorated. Slight scaling or rusting of the metal is normal. Make sure the push pins hold the air tubes
in place.
Floor and Wall Firebricks - replace any severely damaged firebrick along the side or floor of the firebox.
© Travis Industries 100-01164 4041115
Page 27
Door Parts
Maintaining Your Appliance 27
8
14
1/8 Hex Wrench
7
12
13
# 20 Torx Driver
NOTE: Place the glass gasket around the perimeter of the door retainer.
NOTE: Glue the door gasket to the door retainer.
1
2
3
4
5
6
9
10
11
9/16" Wrench
ID # Description Qty Part # ID # Description Qty Part #
1 Door Shell - Black
Door Shell - Brass
Door Shell - Pewter 3Glass Gasket1100-01164 4 Door Retainer (w gasket) 1 224-23029 5 Gasket Cement 1 99900409 6 Door Gasket 1 99900406 7 Door Handle Asbly - Black
Door Handle Asbly - Brass
Door Handle Asbly - Pewter 9 Washers 2 100-03501 10 Cam 1 99900417 11 Nut, Brass 1 101-00007 12 Glass Clips - Top
13 #8-32 3/8" Type F Screw 8 225-20039 14 Set Screw 2 225-20038
1 230-00578
230-00579 230-00577
1 224-14042
99900410 224-14052
2Glass (19-1/4" x 9-7/8")1173-01001
8 Spring - Black
Spring - Brass Spring - Pewter
Glass Clip - Bottom
1 100-14122
2 1
99300100 100-04103
224-230022 224-230021
Replacing the Glass
The glass must not contact the door retainer or glass clips directly. The glass gasket and glass clip gaskets insulate the glass to prevent cracking. Do not over-tighten the glass clips.
See "Door Shell Installation" (pg. 32) for details on removing the door handle and shell. NOTE: The glass gasket is placed in the grove along the inside perimeter of the door retainer. Make sure the glass clip screws are all fully tightened - they must be flush with the door retainer for the door shell to install.
Replacing the Door Gasket
The door gasket inserts into the outer groove of the door retainer. Stove gasket cement holds it in place. Before installing, remove any residual cement. Lay the gasket in place (start at the lower left corner) and cut off any excess gasket (do not stretch the gasket. The cement fully cures with heat from the stove. You may need to open and close the door repeatedly to get the gasket to seat fully.
Replacing the Door Handle
See the illustration above for a component list (see pg. 25 for details on adjusting the door).
© Travis Industries 100-01164 4041115
Page 28
28 Maintaining Your Appliance
Firebox Parts
9
8
1
10
12
2
3
10
11
10
10
10
11
10
12
10
10
7
10
6
10
10
10
10
5
10
4
ID # Description Qty Part # ID # Description Qty Part #
1 Air Tubes & Sleeve 1 98900210 2 Air Tube Roll Pins 6 98900357 3 Air Tube Retainer Sleeve 3 100-11001 4 Baffle Support, Front "Y" 1 99900277 5 Baffle Support, Rear "T" 1 99900278 6 Damper Plate 1 98900320 7 Damper Slider 1 98900340 8 Damper Yoke 1 98900326 9 Damper Extension Rod with
Pull Ring
1 98900333 10 Brick - 9" x 4.5" un-cut 21 175-00001 (1)
98900102 (9)
11 Brick, Cut - 8.25" x 4.5" 2 251-00010 12 Brick, Cut – 6.25” x 4.5” 2 251-00011
Floor and Side Firebrick Removal & Replacement
Do not pry firebrick - they chip and crack easily. Remove the floor firebricks first. The side firebrick
are removed later because they are pinned in place by the floor firebrick. Clean the firebox prior to replacing the firebrick.
© Travis Industries 100-01164 4041115
Page 29
Maintaining Your Appliance 29
Baffle Removal & Replacement
1 Lift up on the front portion of the front three firebricks.
2 Lift the front baffle support “Y” and rotate it forward until it can be removed.
3 Slide the center front firebrick forward and out the door opening. Then slide the side front
firebricks towards the middle then out in the same manner.
4 Slide the center baffle support forward and out of the firebox.
5 Slide the rear firebrick forward and out of the firebox. NOTE: When the center rear firebrick are
slid forward the damper plate will come to rest on the rear secondary air tube and rear air channel.
6 Slide the damper slider all the way forward.
7 Reach into the firebox and push up on the damper yoke until the damper yoke separates from the
damper slider. Remove both the damper slider and damper plate by sliding them between the front two secondary air tubes.
REPLACEMENT INSTRUCTIONS:
8 Place the damper plate above the secondary air tubes in the rear center of the firebox.
9 Position the damper slider so the damper yoke inserts into the two tubes on the damper slider
(make sure to have correct orientation). Then slide the damper slider over the damper plate until both are centered in the firebox.
10 Follow the instructions above in reverse order, starting with step number 5.
Air Tube Removal & Replacement
Air Tube Collar
Air Tube
Remove the left pin on the air tube collar
a
Roll Pin
Slide the air tube to the left, swing it
b
down and remove from the firebox.
© Travis Industries 100-01164 4041115
Page 30
30 Limited 7 Year Warranty
To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase
date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this gas appliance (appliance is defined as the equipment manufactured by Travis Industries, Inc.) to be defect-free in material and workmanship to the original purchaser from the date of purchase as follows:
Check with your dealer in advance for any costs to you when arranging a warranty call.
Mileage or service charges are not covered by this warranty. This charge can vary from store to store.
Years 1 & 2 - COVERAGE: PARTS & LABOR
Firebox Assembly:
Firebox, Baffle Supports, Air Tubes, Air Channels, Convection Chamber
Door Assembly:
Solid Brass or Cast Door, Latch Assembly, Glass Retainers
Plated Finish
Plated Door, Legs, etc… See "Conditions & Exclusions" # 9 below.
Air Control Assembly
Slider Plate, Pressure Plate
Exclusions: Paint, Gasketing
Years 3 Through 5 - COVERAGE: PARTS & LABOR
Firebox Assembly:
Firebox, Baffle Supports, Air Tubes, Air Channels, Convection Chamber
Air Control Assembly
Slider Plate, Pressure Plate
Exclusions: Paint, Gasketing, Plated Finish, Accessories (Legs, Pedestal, Panels, Blower), Glass, Firebrick, Re-Installation Allowance
Years 6 & 7 - COVERAGE: PARTS ONLY
Firebox Assembly:
Firebox, Baffle Supports, Air Tubes, Air Channels, Convection Chamber
Exclusions: Paint, Gasketing, Plated Finish, Accessories (Legs, Pedestal, Panels, Blower), Glass, Firebrick, Re-Installation Allowance, One-
Way Freight Allowance, Labor
CONDITIONS & EXCLUSIONS
1. This new appliance must be installed by a qualified installer. It must be installed, operated, and maintained at all times in accordance with the instructions in the Owner’s Manual. Any alteration, willful abuse, accident, neglect, or misuse of the product shall nullify this warranty.
2. This warranty is nontransferable, and is made to the ORIGINAL purchaser, provided that the purchase was made through an authorized Travis dealer.
3. Discoloration and some minor expansion, contraction, or movement of certain parts and resulting noise, is normal and not a defect and, therefore, not covered under warranty. Over-firing (operation where the steel may glow red) of this appliance can cause serious damage and will nullify this warranty.
4. The warranty, as outlined within this document, does not apply to the chimney components or other Non-Travis accessories used in conjunction with the installation of this product. If in doubt as to the extent of this warranty, contact your authorized Travis retailer before installation.
5. Travis Industries will not be responsible for inadequate performance caused by environmental conditions such as nearby trees, buildings, roof tops, wind, hills or mountains or negative pressure or other influences from mechanical systems such as furnaces, fans, clothes dryers, etc.
6. This Warranty is void if:
a. The unit has been operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals. b. The unit is subject to submersion in water or prolonged periods of dampness or condensation. c. Any damage to the unit, combustion chamber, heat exchanger or other components due to water, or weather damage which is the result of, but not
7. Exclusions to this 7 Year Warranty include: injury, loss of use, damage, failure to function due to accident, negligence, misuse, improper installation, alteration or
8. This 7 Year warranty excludes damage caused by normal wear and tear, such as paint discoloration or chipping, worn or torn gasketing, chipped or cracked
9. Damage to brass or plated surfaces caused by fingerprints, scratches, melted items, or other external sources left on the surfaces from the use of abrasive
10. TRAVIS INDUSTRIES, INC. is free of liability for any damages caused by the appliance, as well as inconvenience expenses and materials. Incidental or
11. This warranty does not cover any loss or damage incurred by the use or removal of any component or apparatus to or from the Travis appliance without the
12. Any statement or representation of Travis products and their performance contained in Travis advertising, packaging literature, or printed material is not part of
13. This warranty is automatically voided if the appliance’s serial number has been removed or altered in any way. If the appliance is used for commercial purposes,
14. No dealer, distributor, or similar person has the authority to represent or warrant Travis products beyond the terms contained within this warranty. TRAVIS
15. Travis Industries will not cover the cost of the removal or re-installation of hearths, facing, mantels, venting or other components.
16. If for any reason any section of this warranty is declared invalid, the balance of the warranty remains in effect and all other clauses shall remain in effect.
17. This 7 year warranty is the only warranty supplied by Travis Industries, Inc., the manufacturer of the appliance. All other warranties, whether express or implied,
limited to, improper chimney/venting installation.
adjustment of the manufacturer's settings of components, lack of proper and regular maintenance, damage incurred while the appliance is in transit, alteration, or act of God.
firebrick, etc. Also excluded is damage to the unit caused by abuse, improper installation, modification of the unit, or the use of fuel other than that for which the unit is configured (use cord wood only).
cleaners is not covered in this warranty. Damage to the surfaces from over-firing (operation where the steel may glow red) is not covered in this warranty.
consequential damages are not covered by this warranty. In some states, the exclusion of incidental or consequential damage may not apply.
express written permission of TRAVIS INDUSTRIES, INC. and bearing a TRAVIS INDUSTRIES, INC. label of approval.
this 7 year warranty.
it is excluded from this warranty.
INDUSTRIES, INC. assumes no liability for such warranties or representations.
are hereby expressly disclaimed and purchaser’s recourse is expressly limited to the warranties set forth herein.
IF WARRANTY SERVICE IS NEEDED:
1. If you discover a problem that you believe is covered by this warranty, you MUST REPORT it to your Travis dealer WITHIN 30 DAYS, giving them proof of purchase, the purchase date, and the model name and serial number.
2. Travis Industries has the option of either repairing or replacing the defective component.
3. If your dealer is unable to repair your appliance’s defect, he may process a warranty claim through TRAVIS INDUSTRIES, INC., including the name of the dealership where you purchased the appliance, a copy of your receipt showing the date of the appliance’s purchase, and the serial number on your appliance. At that time, you may be asked to ship your appliance, freight charges prepaid, to TRAVIS INDUSTRIES, INC. TRAVIS INDUSTRIES, INC., at its option, will repair or replace, free of charge, your appliance if it is found to be defective in material or workmanship within the time frame stated within this 7 year warranty. TRAVIS INDUSTRIES, INC. will return your appliance, freight charges (years 1 to 5) prepaid by TRAVIS INDUSTRIES, INC., to your regional distributor, or dealership.
4. Check with your dealer in advance for any costs to you when arranging a warranty call. Mileage or service charges are not covered by this warranty. This charge
can vary from store to store.
Ceramic Glass
Glass (breakage from thermal shock)
Re-Installation Allowance
Firebrick
Breakage from thermal shock
One-Way Freight Allowance
Accessories
Legs, Pedestal, Panels, Blower
Door Assembly:
Solid Brass or Cast Door, Latch Assembly, Glass Retainers
Door Assembly:
Solid Brass or Cast Door, Latch Assembly, Glass Retainers
In cases where heater must be removed from home for repairs, a partial cost of re-installation is covered (pre-authorization required)
One-way freight allowance on pre-authorized repair done at factory is covered.
One-Way Freight Allowance
One-way freight allowance on pre-authorized repair done at factory is covered.
Air Control Assembly
Slider Plate, Pressure Plate
© Travis Industries 100-01164 4041115
Page 31
Listing Label
W
Listing Information 31
DO NOT REMOVE THIS LABEL
LISTED SOLID FUEL BURNING APPLIANCE
SUITABLE FOR USE IN RESIDENTIAL, ALCOVE
AND MOBILE HOME INSTALLATIONS.
MODEL:
LIBERTY (520-NT)
TESTED TO RELEVANT PORTIONS OF UL 1482, 737 AND 907.
SERIAL
NUMBER
PREVENT HOUSE FIRES - Install and use only in accordance with the Lopi Liberty (520-NT) owner’s manual. Contact your local building or fire officials about restrictions and installation inspection in your area. Refer to local building codes and the chimney manufacturer’s instructions for precautions required for passing a chimney through a combustible wall or ceil­ing. Do not run a chimney connector through a combustible wall or ceiling. Do not connect this unit to a chimney flue serv­ing another appliance. Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or other means approved by local building or fire officials.
FREESTANDING INSTALLATION
STANDARD RESIDENTIAL FREESTANDING INSTALLATIONS REQUIRE: 6” diameter, minimum 24 MSG black or 25 MSG blued steel connector, with listed (type HT) factory-built chimney, suitable for use with solid fuels or masonry chimney. Pedestal or legs are required.
ALCOVE INSTALLATIONS REQUIRE: One of the listed doublewall connectors shown below. Pedestal or legs are required. Maximum alcove depth 48”, minimum alcove height 84”.
MOBILE HOME AND REDUCED CLEARANCE INSTALLATIONS REQUIRE: One of the listed doublewall connectors shown below. In addition, mobile home installations require outside air - use the optional pedestal or outside air boot. Pedestal or legs are required.
• DURAVENT model DVL with DURA-PLUS chimney
• AMERI-TEC model DCC with model HS chimney
• SECURITY model DP with SECURITY model ASHT or S2100 chimney
Replace glass only with LOPI supplied NEOCERAM ceramic
CLEARANCES AND
FLOOR PROTECTION
REQUIREMENTS:
STANDARD RESIDENTIAL
INSTALLATION (SINGLEWALL
A. SIDEWALL TO UNIT B. BACKWALL T O UNIT C. CORNER TO UNIT D. SIDEWALL TO CONNECTOR E. BA CKWALL T O CONNECTOR F . CORNERW ALL TO CONNECTOR
For use with solid wood fuels only (cord wood). Operate with feed door closed - open to feed fire only. Do not use a grate or elevate fire - build fire directly on the hearth.
Manufactured by:
By:
4800 Harbour Pointe Blvd. SW Mukilteo,
• METALFAB model DW connector with TG chimney
• Standard Masonry Chimney with any one of the above listed connectors
MOBILE HOME, ALCOVE AND
REDUCED CLEARANCE INSTALLATIONS
CONNECTOR)
16” 15”
9.5” 28”
18.25” 21”
SIDEWALL
(REQUIRES DOUBLE WALL CONNECTOR)
16” 10”
7.5”
27.5”
12.75”
18.5”
MINIMUM CLEARANCES TO COMBUSTIBLES:
BACKWALL
STOVE
A
EDB
ADJACENT WALL
45û
STOVE
F
C
ADJACENT WALL
FLOOR PROTECTOR
6" MIN.
6"
MIN.
STOVE
16" MIN.
OPTIONAL EQUIPMENT: Rear blower (electrical rating: 115V, 60 Hz., 1.8 Amps)
Certified to comply with July 1990 particulate emission standards.
2004 2005 2006 Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec.
© Travis Industries 100-01164 4041115
glass (5mm).
U.S. ENVIRONMENTAL PROTECTION AGENCY
DATE OF MANUFACTURE
0210IGN
Page 32
32 Optional Equipment
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAAAA
Door Shell Installation
1 Remove the door retainer shipping latch following the directions below.
Standard Screwdriver
Rotate this shaft 1/4 turn clockwise until the door unlatches.
Swing the door retianer open. Remove and discard the shipping latch and nut.
Shipping Latch
Door Retainer
9/16" Wrench
2 Place the door shell face down on a non-scratching surface. Lift the door retainer off the hinges.
Insert the retainer into the door shell following the directions below. Note how the door shell is guided into place
Door Retainer
Door Shell
© Travis Industries 100-01164 4041115
The indent on the door retainer slides into the clip on the door shell (on both sides).
Page 33
Optional Equipment 33
3 Attach the retainer to the shell following the directions below.
Make sure the door retainer is centered on the door shell. You can gauge the alignment by looking at the gaps here.
1/8” Hex Wrench
Once the door is aligned, tighten the two set screws on the bottom of the door shell to secure the door retainer.
4 Attach the door handle
following the directions to the right.
5 Replace the door on the
hinges and latch the door.
6 Attach the ashlip trim
following the directions below.
NOTE: in rare cases the door retainer may not line up with the door shell, preventing the door handle from lining up correctly. To adjust the position horizontally, loosen the set screws (see step 3) and adjust the door retainer position. To adjust vertically, remove the retainer and adjust the clips on the door shell (see step 2).
9/16" Wrench
1/16” Hex Wrench
© Travis Industries 100-01164 4041115
Slide the ashlip trim into place then tighten the three set screws on the bottom of the ashlip to secure.
Page 34
34 Optional Equipment
Stove Leg Installation
Part Numbers: Brass # 99200500, Cast Black # 99200800, Black Steel # 99200100
Raise the stove 8" (use lumber). Attach each leg following the instructions below.
Attach each leg to the stove by inserting a bolt and washer through the hole or slot in the leg and into the threaded hole on the stove.
These rubber-tipped bolts are for leveling the stove. Make sure they contact the floor. Do not adjust with weight on the legs, the rubber tips may tear.
9/16" Socket Wrench
© Travis Industries 100-01164 4041115
Page 35
Pedestal (Part # 99200106)
If using outside air with the pedestal, follow the directions below under "Using Outside Air with the Pedestal" prior to installing the pedestal.
Attachment Bolts and Washers - use a 9/16"
socket wrench to attach the pedestal to
the stove.
23 5/8”
Optional Equipment 35
Optional Air Intake Port
If installing in a mobile home, insert the lag bolts through
these holes and screw them into the floor with a 1/2" socket
wrench.
22
When attached, the faceplate of the stove is 4 3/4” in front of the
front edge of the pedestal.
OUTSIDE AIR EQUIPMENT
Insulation is used to seal
the side edges of the pedestal
.
Screen is used to prevent
rodents from entering.
Staples are used to attach
the screen to the floor.
The cover plate is used to seal off room air.
Using Outside Air with the Pedestal
Before installing, check the section "Outside Air Requirements" 11 for installation concerns.
1. Determine the location of the outside air hole penetrating the floor (& hearth). The illustration above details the size of pedestal and its location in relation to the stove. The hole may be cut anywhere underneath the pedestal, as long as it is not within 2" of the outside perimeter of the pedestal, is at least 16 square inches in area, and does not interfere with structural members of the home. Place the rodent screen over the hole (above or below) and secure with staples.
2. Attach the stove to the pedestal with the included bolts. Tuck the included insulation underneath the side edges of pedestal to seal off any air from entering underneath the pedestal.
© Travis Industries 100-01164 4041115
Page 36
36 Optional Equipment
Rear Blower Installation (Part # 99000138)
The rear blower improves heat transfer by pushing heated air through the convection channel. Operating instructions are described in the section "Blower Operation".
1 The stove should be in place with the legs installed prior to installing the rear blower.
2 Follow the directions below to install the blower. Use the
Use the wire clip to insure the wires from the thermodisk are held in place away from the firebox (this prevents damage to the wires).
Thermodisk
Wire Clip
Blower Box
This portion hooks on the top edge of the rear heat shield.
This portion of the wire clips slides over the rear heat shield
The wires pass through the eye of the wire clip.
The two yellow wires attach to the thermodisk.
Three holes for attaching the blower box to the back of the stove
Slide the thermodisk assembly into the space between the stove and rear heat shield.
Run both of the wires from the thermodisk down behind the stove and through the eye of the wire clip.
Wire Clip
Power Cord (exits from back of blower box)
FRONT
© Travis Industries 100-01164 4041115
Page 37
Optional Equipment 37
Outside Air Boot Installation (Part number 99200134)
The outside air boot routes outside air to the stove for combustion. Refer to the section "Outside Air Requirements" for installation concerns. The directions below detail installation.
1 Refer to the illustration below to determine the location and size of the hole penetrating the floor
and hearth. The knock-out (which is pre-removed) is 6-11/16" behind the face of the stove. Cut the hole prior to locating the stove.
2 Attach gasket to the bottom edge of the lower air boot section (near the screen). Attach gasket
on top of the flanges on the upper air boot section. Slide the two sections together with both seams facing the rear (do not attach the two sections at this time).
3 Follow the directions below for attaching the upper section of the air boot (with gasket) to the
stove.
4 Slide the lower section down until it contacts the hearth. Attach the two sections together
following the directions below
Use a
Bottom of Stove
Attach the included gasket to all four top edges of the air boot.
screwdriver to pry out the knock-out (if applicable).
Attach gasket to the bottom edge of the air boot.
8-7/8”
Floor (and hearth)
5-1/8”
Attach the air boot with the two screws included with the kit.
1/4" Nutdriver
Use the included screws to attach the two telescoping portions of air boot together. The included drill bit should be used to drill the hole. Make sure the air boot is expanded to the correct size before drilling.
9/64” Drill Bit
The hole in the floor (and hearth) must be a minimum 16 square inches. It should be 1/2” smaller than the footprint of the air boot in each dimension to allow for the gasket to seal.
5/16" Nutdriver
© Travis Industries 100-01164 4041115
Page 38
38 Index
Air Control ...................................................20
Air Tube Part Number ....................................28
Air Tube Removal & Replacement ....................29
Alcove.........................................................12
Ash Disposal ................................................24
Baffle Parts ..................................................28
Baffle Removal and Replacement .....................29
Blower Cleaning............................................26
Blower Does Not Run (Troubleshooting) ............23
Blower Installation (rear) .................................36
Blower Operation (optional) .............................21
Burn Rate ....................................................20
Cathedral Ceiling...........................................14
Ceiling Penetration ........................................10
Chimney Cleaning .........................................25
Chimney Inspection (Creosote) ........................25
Chimney Requirements ..................................10
Chimney Termination Requirements..................11
Cleaning the Ash...........................................24
Cleaning the Glass ........................................24
Clearances (stove) ........................................8
Close Clearance Connectors ...........................8
Connector Requirements ................................10
Creosote Check ............................................25
Daily Maintenance .........................................24
Dimensions ..................................................6
Door and Glass Inspection ..............................25
Door Assembly .............................................27
Door Gasket Replacement ..............................27
Door Handle Replacement ..............................27
Door Opening ...............................................17
Door Parts ...................................................27
Draft Performance .........................................10
Elbows (Chimney) .........................................10
Emissions ....................................................6
EPA Approval ...............................................6
Exterior Chimney...........................................11
Features......................................................6
Fire Starting .................................................19
Firebox Assembly..........................................28
Firebox Parts................................................28
Firebrick and Baffle Inspection .........................26
Firebrick Removal & Replacement ....................28
Floor Protection Requirements (stove) ...............8
Glass Cleaning .............................................24
Glass Replacement .......................................27
Hearth (Floor Protection - Stove) ......................8
Hearth Stove ................................................16
Heating Specifications ....................................6
Hints for Burns..............................................22
Installation Options ........................................6
Installation (stove) .........................................7
Leg Installation .............................................34
Listing Label.................................................31
Maintenance ................................................24
Mobile Home Requirements ............................13
Monthly Maintenance .....................................25
Noise (Normal Operating Sounds) ....................21
Non-Combustible Alcove.................................12
Opening the Door ..........................................17
Operation ....................................................17
Outside Air Boot Installation.............................37
Outside Air...................................................11
Over-Firing the Stove .....................................17
Overnight Burn .............................................21
Paint (Touch-Up Paint) ...................................26
Paint Curing .................................................17
Rear Blower Installation ..................................36
Re-Loading the Stove.....................................21
Safety Label .................................................31
Safety Precautions ........................................4
Smell (from paint curing) .................................17
Smoke Enters Room (Troubleshooting)..............23
Sounds (Normal Operating Sounds) ..................21
Starting a Fire...............................................19
Stove Does Not Burn Long Enough...................23
Stove is Not Hot Enough (Troubleshooting) ........23
Table of Contents ..........................................3
Touch-Up Paint.............................................26
Troubleshooting (Operation) ............................23
Warranty Card ..............................................2
Warranty .....................................................30
Wood..........................................................22
Yearly Maintenance .......................................26
© Travis Industries 100-01164 4041115
Loading...