Blower, DVS Gas (Berkshire, Tree of Life, Prairie, Cedar, 2001 Allegiance) Part # 99000153
CHECK CONDITION OF SHIPMENT
Upon receipt of this kit, check the condition of the packaging. Damage to the package should be noted on the carrier's freight
receipt. Any damage claims as a result of shipping must be handled through the shipper. Travis Industries will provide assistance
in resolving shipping claims or replacing items not included in the package. Please report any missing items immediately.
COMPATIBILITY
• Lopi Berkshire • Tree of Life • Avalon Prairie • Avalon Cedar • Lopi Allegiance (2001 model)
ITEMS NEEDED FOR ASSEMBLY
• 11/32” Socket Wrench • 1/4” Nutdriver • 1/2” Open End Wrench
PACKING LIST
• Blower Assembly • Wiring Harness • Thermodisk • Two Rubber Grommets (with spacers)
• Two Nuts and Washers • Stud Plate • Rheostat (with attachment nut & lock washer) • Rheostat Knob
INSTALLATION INSTRUCTIONS
WARNING: Turn the gas control valve to off and make sure the appliance has fully cooled prior to
conducting service.
1 Attach the two black wires on the included wiring harness to the thermodisk (orientation does not matter). Then slide
the thermodisk into the holder underneath the burner pan at the right rear of the stove.
All Models
Except the
Tree of Life and
2007 Berkshire
Tree of Life
and
2007 Berkshire
Back of
Back of Stove
Stove
Remove the snap disk cover plate below
a
the burner on the
the stove from the front).
left side (when facing
Snap Disk Bracket
(attached to stove)
Snap Disk
Snap Disk Wires on Wiring Harness
(Black - orientation does not matter)
Attach the snap disk
b
using the screws
removed in step "a".
Page 1 of 4 4070219
Attach the wires
c
labeled snap disk to
the snap disk.
Snap Disk Wires
(Black - orientation
does not matter)

Blower, DVS Gas (Berkshire, Tree of Life, Prairie, Cedar, 2001 Allegiance) Part # 99000153
2 Place the blower near the rear of the stove. Attach the wiring in grommets following the directions below.
Remove one of the screws holding
a
the mounting bracket in place. Insert
the screw through the eyelet on the
green ground wire and replace.
1/4" Nutdriver
Back of
Stove
Attach the black and white wires
b
labeled “Blower” to the blower
(orientation does not matter).
f
Route the wires labeled “Valve
on/off” and “Solenoid” under
c
the burner pan to a location
near the gas control valve.
Attach the two wires leading
from the control box to the two
block wires labeled “Rheostat”.
e
Slide the rubber grommets (with
d
spacers inserted inside) onto the
fan mounting bracket.
Attach the molex connector.
DO NOT PLUG THE STOVE
IN UNTIL INSTALLATION IS
COMPLETE.
Page 2 of 4 4070219

Blower, DVS Gas (Berkshire, Tree of Life, Prairie, Cedar, 2001 Allegiance) Part # 99000153
3 Slide the left side of the blower mounting bracket over the grommets on the left mounting bracket attached to the
stove (see the illustration below). Then insert the stud plate through the right side grommets and through the right
mounting bracket on the stove. Secure the stud plate with the included washers and nuts
Make sure the bracket
Left Mounting
Bracket (on stove)
Right Mounting
Bracket (on stove)
slides into the groove on
the rubber grommets.
Blower Mounting
Bracket
Rubber
Grommet
Back of
Stud Plate
Stove
Blower Mounting Bracket
Stud Plate
Blower Mounting Bracket
11/32”
Socket
4 Make sure all of the wiring is placed away from the blower impeller and the bottom of the burner. Use lock ties, if
necessary, to ensure no wires are damaged.
Washer
Nut
Page 3 of 4 4070219

Blower, DVS Gas (Berkshire, Tree of Life, Prairie, Cedar, 2001 Allegiance) Part # 99000153
5 Open the control cover following the directions below. Remove the button plug and install the rheostat.
Loosen the two screws holding the control
box in place. This allows access to the
a
back of the control box.
Phillips
Screwdriver
Back of
Stove
Control Box
Attach the rheostat wires to the two
b
quick connects inside the control
box (orientation does not matter).
Rheostat
Attach
the knob.
NOTE: make sure the
fiberglass heat shield is in
place when re-attaching the
control box (all models except
the cedar).
c
Attach the rheostat to
the control panel with
the included nut and
star washer.
1/2"
Wrench
NOTE: this tab fits into the
hole on the mounting bracket.
6 If using the modulating remote thermostat, attach the red and brown wires to the gas control valve.
Attach the red and
brown wires to the top
and bottom terminals
on the gas control
VALVE
“ON/OFF”
7 Plug the blower in. Let the heater achieve operating temperature and test blower operation.
Page 4 of 4 4070219