Travis Industries 4415 HO GSR2, 4415 HO GSR Owner's Manual

Page 1
4415 HO
GSR2
(with screen)
Owner’s Manual
WARNING:
If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested and Listed by
HOT GLASS WILL CAUSE BURNS
DO NOT TOUCH GLASS UNTIL COOLED
NEVER ALLOW CHILDREN TO TOUCH GLASS
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance
Report # 100866536PRT-001
ANSI Z21.88a-2014
CSA 2.33a-2014
Operation Maintenance
and shall be installed for the protection of children and other at-risk individuals.
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. A conversion kit is supplied with the appliance.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
Travis Industries, Inc. 12521 Harbour Reach Dr., Mukilteo, WA 98275 www.travisproducts.com Copyright 2014, T.I. $10.00 4140627 100-01354
Page 2
2 Introduction
Introduction
We welcome you as a new owner of a 4415 HO gas fireplace. This manual details operation and maintenance of this fireplace. Please familiarize yourself with the Owner's Manual before operating your heater and save the manual for future reference.
Important Information
No other 4415 HO gas fireplace has the same serial number as yours. The serial number is on the listing label that is chained to the gas control valve. This serial number may be needed in case you require service.
Model: 4415 HO Fireplace Serial Number: Purchase Date: Purchased From:
Register your warranty online at:
traviswarranty.com
Or, mail your warranty card to:
Travis Industries House of Fire 4800 Harbour Pointe Blvd. SW Mukilteo, WA 98275
Save Your Bill of Sale.
To receive full warranty coverage, you will need to show evidence of the date you purchased your heater. Do not mail your Bill of Sale to us.
We suggest that you attach your Bill of Sale to this page so that you will have all the information you need in one place should the need for service or information occur.
Installation Warnings
Installation requirements are printed in the 4415 HO GSR2 Installation Manual (part #
100-01353). All requirements in the installation manual must be met.
Failure to follow all of the requirements may result in property damage, bodily injury,
or even death.
This heater must be installed by a qualified installer who has gone through a training
program for the installation of direct vent gas appliances.
This appliance must be installed in accordance with all local codes, if any; if not,
follow ANSI Z223.1 and NFPA 54(88).
In Manufactured or Mobile Homes must conform with Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1. This appliance may be installed in Manufactured Housing only after the home is site located.
The fireplace is designed to operate on natural gas, or propane (LP). All exhaust gases must be vented outside the structure of the living-area.
Combustion air is drawn from outside the living-area structure.
Notify your insurance company before hooking up this fireplace.
© Travis Industries 4140627 100-01354
Page 3
Introduction 3
Table of Contents
Introduction ................................................... 2
Important Information ................................... 2
Installation Warnings .................................... 2
Table of Contents .......................................... 3
Features ......................................................... 3
Heating Specifications .................................. 3
Before You Begin .......................................... 6
Remote Control Warnings .................................... 6
Remote Set-Up ............................................... 7
Verify the Switch is on “REMOTE” .................. 7
Synchronize the Transmitter to the IFC ........... 7
Clearing the System Memory ............................ 7
Starting the Heater for the First Time .......... 8
Location of Controls ..................................... 8
Direct Operation ............................................ 8
Continuous/Intermittent Pilot Switch .......... 9
Switching from Intermittent (IPI) to
Continuous Pilot (CPI) ...................................... 9
Remote Operation ....................................... 10
Display Overview ............................................ 10
Listen for the “Beep” ...................................... 10
Manual On-Off / Smart Thermostat / Standard
Thermostat ....................................................... 11
Mode Controls (Flame, Blower, Light) ........... 12
Flame Height ....................................................... 12
Blower Speed ..................................................... 12
Mode Controls (continued) ............................. 13
Accent Light ....................................................... 13
Display Fahrenheit or Celsius ................... 13
Low Battery Indicator ................................. 13
Transmitter Batteries ...................................... 13
IFC Batteries .................................................... 13
Battery Replacement .................................. 14
Battery Installation .......................................... 14
Transmitter Battery Installation ..................... 14
Power Outages ............................................ 14
Child-Proof Feature .................................... 15
Normal Operating Sounds ......................... 15
Normal Operating Odors ............................ 15
Yearly Service Procedure ........................... 16
Accent Light Replacement ......................... 17
Glass Frame Removal and Installation ..... 18
Crushed Glass Installation ......................... 20
Glass Cleaning ............................................ 21
Troubleshooting Table ............................... 22
Location of fuses ............................................... 22
Wiring Diagram ........................................... 23
Replacement Parts List .............................. 23
CONDITIONS & EXCLUSIONS ................... 24
IF WARRANTY SERVICE IS NEEDED: ...... 24
Index ............................................................. 26
Features
Works During Power Outages (battery backup )  GreenSmart™ Thermostat / Remote Control  Contemporary Look  Blower for Effective Heat Distribution  Built-In Accent Light (night light)
Standing or Intermittent (GreenSmart) Pilot  Variable-Rate Heat Output
Low Maintenance
Heating Specifications
Approximate Heating Capacity (in square feet)* Up to 2,100 Up to 2,100 Maximum BTU Input Per Hour 42,000 42,000
* Heating capacity will vary with floor plan, insulation, and outside temperature.
© Travis Industries 4140627 100-01354
Natural Gas Propane
Page 4
4 Safety Precautions
IF YOU SMELL GAS:
* Do not light any appliance * Extinguish any open flame * Do not touch any electrical switch or plug or unplug anything * Open windows and vacate building * Call gas supplier from neighbor's house, if not reached, call fire department
This unit must be installed by a qualified installer to prevent the possibility of an explosion. Your dealer will know the requirements in your area and can inform you of those people considered qualified. The room heater should be inspected and cleaned before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc.
The instructions in this manual must be strictly adhered to. Do not use makeshift methods or compromise in the installation. Improper installation will void the warranty and safety listing.
This heater is either approved for natural gas (NG) or for propane (LP). Burning the incorrect fuel will void the warranty and safety listing and may cause an extreme safety hazard. Direct questions about the type of fuel used to your dealer. Check for a label on the flame adjust knob on the gas control valve (this is the best place to check). You may also check for a label on the gas control valve body.
Ok
Gas
Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirements in your area. Notify your insurance company of this heater as well.
It is imperative that control compartments, screens, or circulating air passageways of the heater be kept clean and free of obstructions. These areas provide the air necessary for safe operation.
Do not store or use gasoline or other flammable liquids in the vicinity of this heater.
?
If the flame becomes sooty, dark orange in color, or extremely tall, do not operate the heater. Call your dealer and arrange for proper servicing.
Do not operate the heater if it is not operating properly in any fashion or if you are uncertain. Call your dealer for a full explanation of your heater and what to expect.
Do not operate if any portion of the heater was submerged in water or if any corrosion occurs. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
© Travis Industries 4140627 100-01354
Page 5
Safety Precautions 5
Do not place clothing or other flammable items on or near the heater. Because this heater can be controlled by a thermostat there is a possibility of the heater turning on and igniting any items placed on or near it.
The viewing glass should be opened only for conducting service. Do not operate with cracked, broken, or removed glass.
Any safety screen or guard removed for servicing must be replaced prior to operating the heater.
Operate the heater according to the instructions included in this manual.
If the main burners do not start correctly turn the gas off at the gas control valve and call your dealer for service.
Light the heater using the built-in igniter. Do not use matches or any other external device to light your heater.
Allow the heater to cool before carrying out any maintenance or cleaning.
Never remove, replace, modify or substitute any part of the heater unless instructions are given in this manual. All other work must be done by a trained technician. Don't modify or replace orifices.
Instruct everyone in the house how to shut gas off to the appliance and at the gas main shutoff valve. The gas main shutoff valve is usually next to the gas meter or propane tank and requires a wrench to shut off.
This unit is not for use with solid fuel
Do not place anything inside the firebox (except the crushed glass).
If any component becomes damaged, replace with Travis Industries components.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be supervised when they are in the same room as the heater.
This Manual
Do not throw this manual away. This manual has important operating and maintenance instructions that you will need at a later time. Always follow the instructions in this manual.
Travis Industries, Inc. grants no warranty, implied or stated, for the installation or maintenance of your heater, and assumes no responsibility of any consequential damage(s).
© Travis Industries 4140627 100-01354
Page 6
6 Operation
Before You Begin
Read this entire manual before you use your new fireplace (especially the section "Safety
Precautions" on pages 4 & 5). Failure to follow the instructions may result in property damage, bodily injury, or even death.
Remote Control Warnings
KEEP BATTERIES AND COVER
INSTALLED AT ALL TIMES
The remote control system requires the batteries and battery cover to remain in place at all times. Once the batteries or cover are removed, the system may re-start in standing pilot mode. If this occurs when the heater is in Remote Mode, you will not be able to turn the heater off manually from the battery box.
If you need to replace dead batteries, make sure to turn the appliance off before removing the batteries.
NOTE: If the batteries go dead, the system will operate normally as long as
household power (120v AC) is present.
The transmitter and IFC are radio frequency devices. Placing the transmitter in or near metal may severely reduce the signal range.
Turn off the main gas supply during appliance installation or maintenance or in case of remote control malfunction.
© Travis Industries 4140627 100-01354
Page 7
Operation 7
Remote Set-Up
Verify the Switch is on “REMOTE”
The battery holder has a switch built into it (see below). This switch must remain in the REMOTE position for the remote to operate.
ON REMOTE OFF
Synchronize the Transmitter to the IFC
The transmitter will need to be synchronized to the IFC (Integrated Fireplace Control) before the remote will work correctly. Synchronizing is done in the following two steps below (see below):
Press the PRG (Program) button on the battery box (IFC will beep 3 times). Press the “ON” button on the transmitter (IFC will beep 3 times).
"Beep" "Beep" "Beep"
°F
"Beep" "Beep" "Beep"
NOTE: If power is cut off to the IFC for an extended period of time, you may need to re-synchronize the remote.
Clearing the System Memory
This appliance uses an Integrated Fireplace Control (IFC) to store the unique code for the remote control. If you wish to clear the system memory, MAKE SURE GAS IS TURNED OFF TO THE APPLIANCE then press the PRG (Program) button for 10 seconds. The pilot will start to spark repeatedly, signifying all system memory has been cleared. The system will return to its original configuration a remote will need to be synchronized; and the system will operate in Continuous Pilot mode.
© Travis Industries 4140627 100-01354
Page 8
8 Operation
Starting the Heater for the First Time
Burn the heater at a low setting with the blower off for an extended period (up to 48 hours). This will
cure the painted surfaces. Fumes from the paint curing and oil burning off the steel will occur. This is normal. We recommend opening a window to vent the room.
Condensation may appear on the glass each time you start the heater - this is normal.  Blue Flames will occur on the heater when it first comes on. After fifteen minutes the flames will turn
a more realistic yellow and orange color.
Verify the batteries are installed (see page 14).
Location of Controls
Most features will be controlled by the included remote.
°F
Direct Operation
The fireplace may be directly operated from the battery holder (accessed by removing the face). The three positions are below (see below):
ON – Burner turns on (regardless of transmitter settings). OFF – Burner turns off (regardless of transmitter settings). REMOTE – Burner is controlled by the transmitter.
ON REMOTE OFF
NOTE: When the battery holder switch is turned to ON or OFF, the mode settings (Flame Height, etc.) will
remain in the same state as before the switch was moved (i.e.: the IFC “remembers” the last setting). If you wish to adjust the mode settings use the transmitter mode button to adjust the settings. The thermostat and burner on/off operating functions will not work on the transmitter.
© Travis Industries 4140627 100-01354
Page 9
Operation 9
Continuous/Intermittent Pilot Switch
This heater may run with the pilot continuously running or in Intermittent mode. For most homeowners, Intermittent mode is preferable (this saves fuel, doesn’t give off un-needed heat). However, in some situations the homeowner may prefer to switch the heater to Continuous Pilot mode. The most typical reasons for switching to Continuous Pilot are:
Very Cold Conditions – In very cold conditions you may notice that the burner does not light quickly,
and the flames lift off the burner. If this is situation, we recommend you switch to continuous pilot. This will create a slight draft in the vent, allowing for the burner to light quickly and draft correctly.
Excessive Condensation on Glass After Startup – Certain installations may encounter excessive
fogging on the window after startup (not just the first time the heater was started). This is an aesthetic condition that may be remedied by switching the heater to continuous pilot.
Cold Glass or Heater Front – In very cold conditions you may notice that the heater front and glass
become very cold. To remedy this, switch the heater to continuous pilot.
Frequent On / Off Operation – If you are frequently turning the heater on and off, you may wish to
leave it in continuous pilot. This allows the burner to turn on more quickly, without pilot ignition delay.
Switching from Intermittent (IPI) to Continuous Pilot (CPI)
The pilot mode on this appliance is adjusted using the remote. With the remote in the off position (thermostat off, manual off), follow the directions below to adjust the pilot mode.
F
Press the "MODE" button when the appliance is off to adjust the IPI/CPI.
NOTE: This icon appears when the appliance is in CPI mode.
Press the "UP" button to activate CPI mode.
Press the "DOWN" button to activate IPI mode.
FF
© Travis Industries 4140627 100-01354
Page 10
10 Operation
Remote Operation
When the switch on the battery holder is set to “REMOTE” the transmitter operates the fireplace. Once you understand how the transmitter works, you will be able to operate your fireplace quickly and easily.
Display Overview
The transmitter display has four main sections (see below).
Thermostat Display
Room Temperature Display
F
ON
Read-Out (Thermostat Setting, Function, etc.)
Mode Display (Flame, Blower, Light)
Listen for the “Beep”
Each time you press a button on the transmitter that controls the fireplace, a “beep” will sound from the IFC. When you change thermostat target settings the IFC will not beep.
NOTE: When the batteries start to get low, the IFC will beep twice whenever a button is pressed. When the batteries are nearly depleted, the IFC will no longer beep. See “IFC Batteries” on page 13).
© Travis Industries 4140627 100-01354
Page 11
Operation 11
Manual On-Off / Smart Thermostat / Standard Thermostat
Use the thermostat button to cycle through the three thermostat settings (see below).
Look here for the thermostat setting.
F
ON
Press the thermostat button to cycle through the thermostat settings.
OFF
ON
SMART
MANUAL ON/OFF – The burner will turn on and off using the remote (see below). Press the
On/Off button to control the burner. When off, the display will only show the current temperature.
When in manual setting, the
OFF
word "OFF" will appear here.
F
SMART THERMOSTAT – While in Smart Thermostat mode, the transmitter will control the
burner to achieve the target temperature (see below). Flame height will be adjusted up or down to allow operation without turning the burner on and off (also called “smart modulation”). To adjust the target temperature, press the UP and DOWN buttons until a suitable temperature is achieved.
F
When in smart thermostat
setting, the word "SMART"
will appear here.
SMART
This is the target temperature on the read­out. Use the up or down buttons to adjust the target temperature.
STANDARD THERMOSTAT - While in Standard Thermostat mode, the transmitter will turn the
burner on and off to achieve the target temperature (see below). To adjust the target temperature, press the up and down buttons until a suitable temperature is achieved.
F
When in standard thermostat
setting, the word "ON" will
appear here.
ON
This is the target temperature on the read-out. Use the up or down buttons to adjust the target temperature.
NOTE: If the transmitter batteries go dead while in thermostat setting (standard or smart), the appliance will shut off after approximately 24 hours.
© Travis Industries 4140627 100-01354
Page 12
12 Operation
Mode Controls (Flame, Blower, Light)
Press the Mode button to cycle through the four mode controls (see below).
Press the mode button to cycle through the mode settings.
F
OFF
Look here for
mode controls.
Flame Height
Flame height may be controlled using the UP and DOWN buttons when in Flame Height Mode (see below). The center display will display the 7 settings, from “OFF” to “HI” for full on.
NOTE: Flame height may not be adjusted if operating in Smart Thermostat mode.
Flame Height
Accent
Light
Optional
Blower
F
When in flame height
mode, this icon will
appear darkened.
OFF
MAX
This is the flame height read-out. Use the up or down buttons to adjust the flame height (7 settings).
Blower Speed
The blower may be controlled using the up and down buttons when in Blower Speed mode (see below). The center display will display the 7 settings, from “OFF” to “HI” for full on.
F
OFF
When in blower
mode, this icon will
appear darkened.
MAX
This is the blower speed read-out. Use the up or down buttons to adjust the blower speed (7 settings).
MANUAL MODE – BLOWER OPERATION
When in Manual mode the blower will remain on, even if the burner is turned off and the heater cools. Either manually turn the blower off, or turn off the heater by pressing the On/Off button.
High
Medium
Off
High
Medium
Off
© Travis Industries 4140627 100-01354
Page 13
Operation 13
Mode Controls (continued)
Accent Light
The Accent Light (night light) inside the heater may be turned on and off using the up and down buttons when in Accent Light mode (see below). The center display will display the 7 settings, from “OFF” to “HI” for full on.
F
This is the accent light read-out. Use the up or down buttons to adjust the accent light brightness (7 settings).
When in accent light
mode, this icon will
appear darkened.
OFF
MAX
HINT: If you wish to leave the accent light on while turning the burner off, adjust the Flame Height setting to “OFF” (see above).
Display Fahrenheit or Celsius
With the system in the “OFF” position, press both the MODE and THERMOSTAT buttons simultaneously to toggle between Fahrenheit (F) and Celsius (C).
F
High
Medium
Off
F
C
Low Battery Indicator
Transmitter Batteries
The transmitter has a battery-level indicator. When it indicates low battery voltage (see below), install three new A A A a lkali n e b a t t e r i es int o t h e t r a n s m i t t er (see “Battery Installation” on page 14).
Low Battery Indicator
F
OFF
MAX
IFC Batteries
The IFC (Integrated Fireplace Control) will “beep” twice when a transmitter button is pressed whe n the batteries are low. Install four new AA alkaline batteries into the battery box when this occurs (see “Battery Installation” on page 14). In applications where the appliance is required to provide heat, we recommend replacing the batteries before each heating season.
© Travis Industries 4140627 100-01354
Page 14
14 Operation
Battery Replacement
Battery Installation
Install four AA batteries into the battery holder (see below). These batteries act as a power backup in case the household (AC) current goes out.
Transmitter Battery Installation
Install the three included AAA batteries into the remote.
AA Battery
AA Battery
AAA Battery
AAA Battery
AAA Battery
°F
AA Battery
AA Battery
Power Outages
The remote will work if household current (AC power) is disconnected. The batteries inside the battery box will continue to power the heater but the accent light and blower will not operate.
© Travis Industries 4140627 100-01354
Page 15
Operation 15
Child-Proof Feature
The child-proof feature disables the control buttons, preventing unwanted use of the remote.
Press both the MODE and UP buttons simultaneously to turn this feature on or off.
HINT: This feature is especially useful while using the thermostat setting.
Child Proof Indicator
F
OFF
MAX
Normal Operating Sounds
The appliance may creak with change of temperature -- THIS IS NORMAL.
Extinction Pops It is not unusual, especially on Propane (LP) appliances, to experience a "pop" when the burner is shut off.
Pilot Assembly
The pilot flame will make a clicking sound when starting up. If left on, it will make a slight whisper sound.
Blower(s)
The blower(s) push heated air into the room. You will hear the sound of air movement that increases as the speed is increased.
Gas Control Valve
As the gas control valve is turned on and off you will hear a dull clicking sound. This is the valve opening up and shutting down.
Normal Operating Odors
This appliance has several areas that reach high temperatures. Dust or other p articles on these areas may burn and create an odor. This is normal during startup. You may notice the smell is more acute if the appliance was left idle for a long period.
© Travis Industries 4140627 100-01354
Page 16
16 Maintenance
Yearly Service Procedure
DANGER HIGH VOLTAGE: Disconnect power before attempting maintenance or repair.
Failure to inspect and maintain the heater may lead to improper combustion and a potentially dangerous situation. We recommend the following procedures be done by a qualified technician.
1. Turn the pilot flame to continuous. It should touch approximately 3/8" of the top of the flame sensor. If it does not, contact your dealer for service.
2. Shut off gas to the heater and let it cool for 15 minutes. Remove the glass (see page 16). Glass may be cleaned with glass cleaner and a soft cloth (do not use abrasive cleaners).
3. Remove the crushed glass. Check the media for sooting. A small amount of soot along the b ottom of the media is normal. If excessive sooting is found, the heater will require adjustment. Contact your dealer for service.
4. Inspect the burner and remove any debris.
Make sure the burner is not warped, cracked, or damaged.  Check the firebox and area around the pilot to make sure there is no warping or damage.  If any problem is found, discontinue use and contact your dealer for service.
5. Re-install the crushed glass. Clean and replace the glass. If the glass is damaged, replace it. Make sure the gasket along the perimeter of the glass contacts the face of the firebox and forms an air-tight seal. If it does not, re-align or replace the gasket to ensure an air-tight seal.
6. Inspect the area behind the access door. Clean if necessary. Check the gas control valv e and t he ga s lines. If damage is found, discontinue use and contact your dealer for service. Clean the air chann els, ducts, and blower (if applicable).
7. Start the main burner. Inspect the main burner and pilot flame. After 15 minutes the flames should be orange/yellow and not touch the top of t he firebox. If t he pilot or main burners do not burn correctly, contact your dealer for service. Monitor b lower o peration.
8. Remove any debris or vegetation near the vent termination. Contact your dealer if any sooting or deterioration is found near t he vent te rmination. The venting system should be examined by a qualified agency.
© Travis Industries 4140627 100-01354
Page 17
Maintenance 17
Accent Light Replacement
The accent lights in your heater provide additional lighting. The bulbs will burn out over time. To replace, follow the directions below:
Shut off gas to the heater and let it cool for 15 minutes.  Remove the glass frame (page 18) and crushed glass (page 20). Remove the glass tray (it is held in
place with 6 screws - 1/4” nutdriver – see photos below).
Replace the halogen bulbs with the following bulbs:
NOTE: Take care to not touch the bulbs with your fingers – use foam packing or a paper towel to
handle the bulbs,
© Travis Industries 4140627 100-01354
35 Watt 120 Volt T4 Halogen Bulb (G6.35 Base)
Page 18
18 Maintenance
Glass Frame Removal and Installation
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.
Do not remove the glass frame with the screen attached – it will not disengage correctly and may damage the screen.
The appliance must be completely cool before removing the glass.
Do not strike or slam the glass.
Warning: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.
GLASS FRAME TOOL
The glass frame tool is shipped inside the fireplace, under the concealment cover. The first time it is used you may need to loosen the screw (1/4” wren ch). The tool i s accesse d after removin g the screen.
NOTE: Replace the tool in this location after use.
Remove the concealment cover and pla ce aside. It has two h oles th at aid in removal.
© Travis Industries 4140627 100-01354
Page 19
Maintenance 19
2. Remove the three screws holding the screen in place (1/4” nutdriver- magnetic driver recommended). Then pivot the screen down slightly until the clips on the bottom disengage from the glass frame.
3. Use the glass tool to unlatch the glass frame. Remove the glass frame. The glass frame is held in place with four tabs inserted into four slots at the bottom of the firebox opening.
© Travis Industries 4140627 100-01354
Page 20
20 Maintenance
Crushed Glass Installation
Do not allow the crushed glass to block the air slots or to become too thick (maximum 1 layer deep on the burner). Failure to properly install glass may lead to sooting and improper burning.
If converting to LP (propane), convert the appliance prior to placing the crushed glass.
Install the crushed glass on the glass tray following the directions below.
Quantity of Crushed Glass
7 lbs. (3.1 Kg) 4 lbs. (1.8 Kg)
Before installing the crushed glass, make sure the pilot guard is in place (it is zip-tied to the glass tray – remove and discard the zip-tie). After installing the glass, remove the pilot guard. Make sure no glass covers the pilot opening.
Pilot Guard
Disperse the crushed glass evenly along the glass tray. Make sure the two air channels are free of crushed glass. Use the glass frame tool (o r screwdriver) to
clear this area. Make sure the glass is only 1 layer deep on the burner.
No Logs (stock) Driftwood Log Set
© Travis Industries 4140627 100-01354
Page 21
Maintenance 21
Glass Cleaning
The glass may be cleaned with a non­abrasive cleaner. To clean the inside of the glass, simply remove the glass
on a non-scratching surface, and clean the surface.
WARNING: do not operate the fireplace without the glass frame in place.
frame, place it
© Travis Industries 4140627 100-01354
Page 22
22 Maintenance
Troubleshooting Table
Problem:
Burner Will Not Start
Appliance Beeps
Thermostat Does Not
Work
Blower Does Not
Work
Fireplace Will Not
Distribute Heat
Flames Are Too Blue
Flames Are Too
Short (Under 6")
Thin Layer of Soot
Covers the Glass
Accent Lights
Do Not Work
Possible Cause:
The battery box switch is turned to "OFF" The remote control is not working correctly The thermostat is disconnected or set too low No propane in tank
Heater beeps once: The heater beeps once whenever a button on the remote is pressed
Heater beeps twice: The heater beeps twice whenever a button on the remote is pressed
The battery box switch is turned to "OFF" or “ON” The thermostat is set too low
The fireplace is not getting electricity
The fireplace is not up to temperature ..................
The blower fuse may be blown The fireplace is not getting electricity
The fireplace is not up to temperature
The fireplace has just been started
Improper air shutter adjustment The flame height may be turned too low
Crushed glass or media is placed incorrectly Improper air shutter adjustment
The bulb may be burned out. ................................
The accent light fuse may be blown. ....................
Don't Call for Service Until
You:
Turn the battery box switch to "ON". See the remote control instructions. See "Thermostat Operation". Check Tank Level.
THIS IS NORMAL
The power backup batteries are low. Replace the 4 AA batteries in the battery box (see page 14).
Turn the battery box switch to “REMOTE”. Check thermostat.
Check the breaker switch. Let the fireplace burn for 10 minutes. Replace the fuse. See fuse location below.
Check the breaker switch. Let the fireplace burn for at least 15
minutes. This is normal - see "Starting the Fireplace
for the First Time". Adjust Air Shutter - contact your dealer.
Turn the flame height to "HI" - See "Adjusting the Flame Height".
See "Crushed Glass Installation" page 20. Adjust air shutter - contact your dealer.
See “Accent Light Replacement” page 17. Replace the fuse. See fuse location below.
Location of fuses
The two 3 amp fuses are on the front left of the fireplace, under the concealment cover (see page 18).
© Travis Industries 4140627 100-01354
Fan Fuse
Lights Fuse
Page 23
Maintenance 23
Wiring Diagram
Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
Power
Appliance
Ground
Flame Detect
Appliance
Ground
In
Spark
Rod
Accessory
Power
Black
White
Green
Pilot Sensor
Optional
Blower(s)
3.15A FUSE
System Jumper
IPI/CPI
JUMPER WIRE
Black Black
3 Amp Fuse
Red
Yellow
Black
Yellow / Green
White
Orange
Blue
Green
Blue
Black
Pink
Black
Grey
Yellow
White
Purple
White White
3 Amp Fuse
White
Orange
Accent Light (s)
Integrated Fireplace Control (IFC)
Grey
Orange
Red
Black
TOP
Yellow
(4) AA Batteries
Purple
Battery Box (Manual
On/Off)
Replacement Parts List
Caution: Use only Travis Industries replacement parts. Do not use substitute materials. Warning: Do not operate appliance with the glass front removed, cracked, or broken. Replacement of the
glass should be done by a licensed or qualified service person. Contact your local Travis dealer for a Replacement Parts List.
© Travis Industries 4140627 100-01354
Page 24
24 Limited 7 Year Warranty
Register your TRAVIS INDUSTRIES, INC. Limited 7 Year Warranty online at traviswarranty.com, or complete the enclosed Warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this gas appliance (appliance is defined as the equipment manufactured by Travis Industries, Inc.) to be defect-free in material and w orkmanship to the original purchaser from the date of purchase as follows:
Check with your dealer in advance for any costs to you when arranging a warranty call.
Mileage or service charges are not covered by this warranty. This charge can vary from store to store.
Component
Burner Assembly
Burner Pan Assembly, Air Shutter Assembly, Main Burner Orifice
Electrical Assembly (within heater structure):
Wiring harness, snap discs, rheostat speed control
Gas Control Assembly
Adjustable control valve, fireplace controller, pilot assembly and pilot wiring
Glass
Glass (breakage from thermal shock)
Gold, Nickel & Copper Plating
Face & Door (see “Conditions and Exclusions” # 9)
Accessories
Firebacks, Power Heat Ducts, Andirons, etc…
One-Way Freight Allowance
One-way freight allowance on pre-authorized repair done at factory is covered.
Convection Heat Exchanger
Convection heat exchanger assembly
Firebox Assembly
Adjustable Air Restrictor, Pressure Relief Mechanisms, Glass Attachment Mechanism
Years 1 & 2
Parts & Labor
Years 3 Through 5
Parts & Labor
Years 6 & 7
Parts Only
EXCLUDED COMPONENTS:
Paint, Gasketing, and Accent Light Bulbs
CONDITIONS & EXCLUSIONS
1. This new gas appliance must be installed by a qualified gas appliance technician. It must be installed, operated, and maintained at all times in accordance with the instructions in the Owner’s Manual. Any alteration, willful abuse, accident, neglect, or misuse of the product shall nullify this warranty.
2. This warranty is nontransferable, and is made to the ORIGINAL purchaser, provided that the purchase was made through an authorized TRAVIS dealer.
3. Discoloration and some minor expansion, contraction, or movement of certain parts and resulting noise, is normal and not a defect and, therefore, not covered under warranty. The installer must ensure the appliance is burning as per the rating tag at the time of installation. Over-firing (operation above the listed BTU rate) of this appliance can cause serious damage and will nullify this warranty.
4. The warranty, as outlined within this document, does not apply to the chimney components or other Non-Travis accessories used in conjunction with the installation of this product. If in doubt as to the extent of this warranty, contact your authorized TRAVIS retailer before installation.
5. Travis Industries will not be responsible for inadequate performance caused by environmental conditions such as nearby trees, buildings, roof tops, wind, hills or mountains or negative pressure or other influences from mechanical systems such as furnaces, fans, clothes dryer s, etc.
6. Th is Warranty is void if:
a. The unit has been operated in atmospheres contaminated by chlorine, f luorine or other damaging chemicals. b. The unit is subject to submersion in water or prolonged periods of dampness or condensation. c. Any damage to the unit, combustion chamber, heat exchanger or other components due to water, or weather damage which is the result of, but not limited to, improper chimney/venting installation.
7. Exclusions to this 7 Year Warranty include: injury, loss of use, damage, failure to function due to accident, negligence, misuse, improper installation, alteration or adjustment of the manufacturer's settings of components, lack of proper and regular maintenance, damage incurred while the appliance is in transit, alteration, or act of God.
8. This 7 Year warranty excludes damage caused by normal wear and tear, such as paint discoloration or chipping, worn or torn gasketing, corroded or cracked logs, embers, etc. Also excluded is damage to the unit caused by abuse, improper installation, modification of the unit, drilling of the o rifices, or the use of fuel other than that for which the unit is configured. Units are shipped for natural gas and must be converted to propane using the included conversion kit. Confirm fuel configuration with your installer.
9. Damage to gold or nickel surfaces caused by fingerprints, scratches, melted items , or other external sources left on the gold or nickel from the use of cleaners other than denatured alcohol is not covered in this warranty.
10. TRAVIS INDUSTRIES, INC. is free of liability for any damages caused by the appliance, as well as inconvenience expenses and materials. Incidental or consequential damages are not covered by this warranty. In some states, the exclusion of incidental or consequential damage may not apply.
11. This warranty does not cover any loss or damage incurred by the use or removal of any component or apparatus to or from the gas appliance without the express written permission of TRAVIS INDUSTRIES, INC. and bearing a TRAVIS INDUSTRIES, INC. label of approval.
12. Any statement or representation of TRAVIS products and their performance contained in TRAVIS advertising, packaging literature, or printed material is not part of this 7 year warranty.
13. This warranty is automatically voided if the appliance’s serial number has been removed or altered in any way. If the appliance is used for commercial purposes, it is excluded from this warranty.
14. No dealer, distributor, or similar person has the authority to represent or warrant TRAVIS products beyond the terms contained within this warranty. TRAVIS INDUSTRIES, INC. assumes no liability for such warranties or representations.
15. Travis Industries will not cover the cost of the removal or re-installation of hearths, facing, mantels, venting or other components.
16. If for any reason any section of this warranty is declared invalid, the balance of the warranty remains in effect and all other clauses shall remain in effect.
17. THIS 7 YEAR WARRANTY IS THE ONLY WARRANTY SUPPLIED BY TRAVIS INDUSTRIES, INC., THE MANUFACTURER OF THE APPLIANCE. ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, ARE HEREBY EXPRESSLY DISCLAIMED AND PURCHASER’S RECOURSE IS EXPRESSLY LIMITED TO THE WARRANTIES SET FORTH HEREIN.
IF WARRANTY SERVICE IS NEEDED:
1. If you discover a problem that you believe is covered by this warranty, you MUST REPORT it to your TRAVIS dealer WITHIN 30 DAYS, giving them proof of purchase, the purchase date, and the model name and serial number.
2. Travis Industries has the option of either repairing or replacing the defective component.
3. If your dealer is unable to repair your appliance’s defect, he may process a warranty claim through TRAVIS INDUSTRIES, INC., including the name of the dealership where you purchased the appliance, a copy of your receipt showing the date of the appliance’s purchase, and the serial number on your appliance. At that time, you may be asked to ship your appliance, freight charges prepaid, to TRAVIS INDUSTRIES, INC. TRAVIS INDUSTRIES, INC., at its option, will repair or replace, free of charge, your TRAVIS appliance if it is found to be defective in material or workmanship within the time frame stated within this 7 year warranty. TRAVIS INDUSTRIES, INC. will return your appliance, freight charges (years 1 to 5) prepaid by TRAVIS INDUSTRIES, INC., to your regional distributor, or dealership.
4. Check with your dealer in advance for any costs to you when arranging a warranty call. Mileage or service charges are not covered by this warranty. This charge can vary from store to store.
© Travis Industries 4140627 100-01354
Page 25
Limited 7 Year Warranty 25
© Travis Industries 4140627 100-01354
Page 26
26 Index
Index
Accent Light Replacement ............................... 17
Battery Replacement ........................................ 14
Before You Begin ............................................... 6
Child-Proof Feature .......................................... 15
Continuous/Intermittent Pilot Switch .................. 9
Crushed Glass Installation ............................... 20
Direct Operation ................................................. 8
Display Fahrenheit or Celsius .......................... 13
Features ............................................................. 3
Glass Cleaning ................................................. 21
Glass Frame Removal and Installation ............ 18
Heating Specifications ........................................ 3
Important Information ......................................... 2
Installation Warnings .......................................... 2
Location of Controls ........................................... 8
Low Battery Indicator ....................................... 13
Manual On-Off / Smart Thermostat / Standard
Thermostat .................................................. 11
Mode Controls (Flame, Blower, Light) ......... 12
Normal Operating Odors .................................. 15
Normal Operating Sounds ............................... 15
Power Outages ................................................ 14
Remote Control Warnings ................................. 6
Remote Operation ............................................ 10
Remote Set-Up .................................................. 7
Replacement Parts List .................................... 23
Starting the Heater for the First Time ................ 8
Troubleshooting Table ..................................... 22
Wiring Diagram ................................................ 23
Yearly Service Procedure ................................ 16
© Travis Industries 4140627 100-01354