Traulsen UR30WT, UR48WT, UR30LT, UR48DT, UC27HT User Manual

...
Quality Refrigeration
OWNER’S MANUAL
Instructions for the installation, operation
and maintenance of all Traulsen Spacesaver Models:
Refrigerator Models: UR30HT, UR48HT, UC27HT Freezer Model: UR30LT Refrigerator/Freezer Model: UR48DT Wine Cabinets: UR30WT, UR48WT, UC27WT
This Traulsen unit is built to our highest quality standards. We build our refrigerators, freezers and heated cabinets this way as a matter of pride. This philosophy has made Traulsen the leader in commercial refrig­eration since 1938. We thank you for your choice and confidence in Traulsen equipment and we know you will receive many years of utility from this equipment.
All Traulsen units are placed on a permanent record file with the service department. In the event of any future questions you may have, please refer to the model and serial number found on the name tag affixed to the unit. Should you need service, however, call us on our toll free number, 800-825-8220 between 7:30 am and 4:30 pm CST, Monday thru Friday. It is our pleasure to help and assist you in every possible way.
INSTALLER
COMPLETE THE FOLLOWING INFORMATION PRIOR TO UNIT INSTALLATION
INITIAL START DATE: SERIAL NO.
MODEL TYPE:
COMPANY/INDIVIDUAL NAME:
INSTALLER:
FORM NUMBER TR35749 REV. 5/03 P/N 375-60177-00
TABLE OF CONTENTS
I. The Serial Tag Page 1 II. Receipt Inspection Page 2 III. Installation
a-Location Page 2 b-Packaging Page 2 c-Installing Legs or Casters Page 2 d-Shelf Pins Page 3 e-Installing The Condensate Evaporator Page 3 f-Remote Installation Page 3 g-Cord & Plug Page 3 h-Power Supply Page 3 i-Wiring Diagram Page 3 j-Clearance Page 3 k-Built-In Installation Page 4 l-Electric Outlet Installation Page 5
IV. Miscellaneous Product Features
a-Solar Digital Thermometer Page 5 b-Light Switches Page 5 c-Defogger Control Page 5
V. Operation
a-Adjusting The Temperature Page 6 b-Automatic Defrost Page 6
VI. Care & Maintenance
a-Cleaning The Condenser Page 6 b-Hinge Replacement Page 6 c-Replacing The Gaskets Page 6 d-Cleaning The Exterior Page 7 e-Cleaning The Interior Page 7 f-Changing The Interior Light Page 7
VII. Misc. Operations
a-Adjusting The Shelves Page 7 b-Removing The Drawer Pans Page 7 c-Removing The Drawers Page 7
VIII. Other
a-Service Information Page 7 b-Spare Parts Page 8
c-Warranty Registration Page 8 IX. Trouble Shooting Guide Page 8 X. Warranty Information Page 9 XI. Index Page 10
FORT WORTH, TX.
SERIAL MODEL VOLTS Hz PH
TOTAL CURRENT AMPS MINIMUM CIRCUIT AMPS MAXIMUM OVERCURRENT PROTECTION AMPS LIGHTS WATTS HEATERS AMPS
REFRIGERANT TYPE OZ DESIGN PRESSURE HIGH LOW
REFRIGERANT TYPE OZ DESIGN PRESSURE HIGH LOW
370-60294-00 REV (A)
I. THE SERIAL TAG
The serial tag is a permanently affixed sticker on which is recorded vital electrical and refrigeration data about your Traulsen product, as well as the model and serial number. This tag is located in the upper right interior compartment on all Spacesaver reach­in refrigerator, freezer and undercounter models.
READING THE SERIAL TAG
Serial = The permanent ID# of your Traulsen
Model = The model # of your Traulsen
Volts = Voltage
Hz = Cycle
PH = Phase
Total Current = Maximum amp draw
Minimum Circuit = Minimum circuit ampacity
Lights = Light wattage
Heaters = Not applicable for Spacesaver models
Refrigerant = Refrigerant type used
Design Pressure = High & low side operating
pressures and refrigerant charge
Agency Labels = Designates agency listings
-1-
II. RECEIPT INSPECTION
III. INSTALLATION (continued)
All Traulsen products are factory tested for perfor­mance and are free from defects when shipped. The utmost care has been taken in crating this product to protect against damage in transit. All interior fittings have been carefully secured and the legs or casters and bottom mounted condensate evaporator are boxed and strapped inside to prevent damage. If the unit is equipped with optional locks the door keys will be at­tached to the handle with a nylon strip. The handle is protected by an easily removable nylon netting.
You should carefully inspect your Traulsen unit for damage during delivery. If damage is detected, you should save all the crating materials and make note on the carriers Bill Of Lading describing this. A freight claim should be filed immediately. If damage is sub­sequently noted during or immediately after installa­tion, contact the respective carrier and file a freight claim. Under no condition may a damaged unit be re­turned to Traulsen & Co. without first obtaining writ­ten permission (return authorization).
III. INSTALLATION
III. a -
LOCATION: Select a proper location for your Traulsen Spacesaver unit, away from extreme heat or cold. Allow enough clearance between the unit and the side wall so that
the door (s) may open a minimum of 90°.
III. c - INSTALLING LEGS OR CASTERS: 6 high stainless steel legs are supplied standard for all Traulsen Spacesaver units. Casters in lieu of legs are available as an optional accessory for the same models. These are shipped from the factory packed inside a cardboard box which is strapped to one of the shelves. Remove the nylon strap and open the box, it should contain either four (4) legs or four (4) casters and sixteen (16) bolts.
WARNING: THE CABINET MUST BE BLOCKED AND STABLE BEFORE INSTALLING LEGS OR CASTERS.
To install the legs or casters, first raise and block the unit a minimum of 7from the floor. For installing legs, thread the legs into the threaded holes on the bottom of the cabinet (see figure 1). Be certain that all legs are tightly secured (legs and casters should be tightened to 300 inch/pounds, max). When the unit is set in its final position, it is important for proper op­eration that the unit be level. The legs are adjustable for this purpose, turn the bottom of the leg counter­clockwise to raise it, clockwise to lower it. Level the unit from front to back as well as side to side in this manner, using a level placed in the bottom of the cabi­net.
III. b - PACKAGING: All Traulsen Spacesaver units are shipped from the factory bolted to a sturdy wooden pallet and packaged in a durable cardboard container. The carton is at­tached to the wooden skid with the use of large staples. These should first be removed to avoid scratching the unit when lifting off the crate.
To remove the wooden pallet, first if at all possible, we suggest that the cabinet remain bolted to the pallet during all transportation to the point of final installa­tion. The bolts can then be removed with a 3/4” socket wrench. Avoid laying the unit on its front, side or back for removal of the pallet.
All exterior metal surfaces are protected from scratch­ing during manufacturing and shipping by a plastic covering. This should be removed prior to installa­tion.
NOTE: Traulsen does not recommend laying the unit down on its front, side or back. However, if you must please be certain to allow the unit to remain in an up­right position afterwards for 24 hours before plugging it in so that the compressor oils and refrigerant may settle.
Fig. 1
Please note that Traulsen Spacesaver units are not de­signed to be moved while on legs. If the unit requires moving, a pallet jack or forklift should be used to pre­vent damage. For installing casters, the casters are plate type, and require the use of four (4) bolts each to secure them firmly to the cabinet bottom at each corner (see figure 2). The caster bolts are tightened using a 1/2 socket wrench.
Figure 2
-2-
III. INSTALLATION (continued)
III. d - SHELF PINS: The unit is supplied with shelves and shelf pins in­stalled. Check all shelf pins to assure they are tight­ened down as they may have come loose during ship­ping. Rotate the pins clockwise until they are secured against the side of the cabinet.
III. e - INSTALLING THE CONDENSATE EVAPORATOR: A bottom-mounted electric condensate evaporator is normally supplied on all self-contained models. This is shipped in a cardboard carton secured to the cabi­net interior, and must be installed prior to use.
To install a bottom-mounted electric condensate evaporator (see figure 3).
After the cabinet has been uncrated and the legs/cast­ers attached, locate the four (4) holes on the exterior bottom towards the rear of the cabinet. Then, using the four (4) screws provided, attach the mounting rails to the cabinet bottom (the end flange is to be up and be facing towards the cabinet rear). Next, place the heater into the heater bracket (note the enclosed springs are only to be used when the heater is placed on the floor). Slide heater and bracket into the mount­ing rails. Plug the supplied cord into both the heater on one end, and the electrical outlet, provided on the cabinet exterior bottom towards the front, on the other. Screw the “U-Trap” (UR30LT only) or 90 degree elbow joint (all other Spacesaver models) into the drain line located on the rear of the cabinet and then screw the drain extension into the U-Trap or elbow joint.
Drain Line
U-Trap
Electric Heater
Drain Extension
10-32 x 3/8 Screw (4)
Mounting Rails
Figure 3
Heater Bracket
BMCE Receptacle
A remote model is normally configured for conden­sate to be run to a floor drain unless purchased with a condensate evaporator. The installer is responsible for making the required extension to the floor drain in accordance with good practice and local regulations.
III. f - REMOTE INSTALLATION: Remote models are supplied without compressors, solenoid valves, etc. The correct voltage, amp listing, refrigerant and BTU’s are listed on the unit’s serial tag. It is the responsibility of the installer to specify and supply the correct size compressor(s) based upon this information and on-site requirements. Refrigerant line installation must be done in adhering to good prac­tice and local regulations. See section III. efor in­formation concerning condensate removal for remote models.
III. g - CORD & PLUG: Most self-contained models are supplied with a cord & plug attached. It is shipped coiled at the top of the cabinet, secured by a nylon strip. For your safety and protection, all units supplied with a cord and plug in­clude a special three-prong grounding plug on the ser­vice cord. Select only a dedicated electrical outlet with grounding plug for power source. NOTE: Do not un­der any circumstances, cut or remove the round grounding prong from the plug, or use an extension cord.
III. h -
POWER SUPPLY: It is recommended that the supply voltage be checked prior to connection to be certain that proper voltage for the cabinet wiring is available (refer to the serial tag to determine correct unit voltage). Make connec­tions in accordance with local electrical codes. Use qualified electricians.
Use of a separate, dedicated circuit is recommended. Size wiring to handle indicated load and provide nec­essary overcurrent protector in circuit.
III. i - WIRING DIAGRAM: Refer to the wiring diagram for any service work per­formed on the unit. Should you require one, please contact Traulsen Service at (800) 825-8220, and pro­vide the model and serial number of the unit involved.
III. j - CLEARANCE: In order to assure optimum performance, the condens­ing unit of your Traulsen unit MUST have an adequate supply of air for cooling purposes. Therefore, the operating location must either have a minimum of 12 clearance overhead of the condensing unit or allow for unrestricted air flow at the back of the unit. Clear­ance of at least 12above is required in order to per­form certain maintenance tasks.
The bottom mounted electric condensate evaporator of your Traulsen Spacesaver should be cleaned occa­sionally to keep it clear of dirt and debris.
-3-