Project Quantity Item #
Model Specified: CSI Section 11400
Convertible Reach-In Freezer
Models/Self-Contained
Microprocessor
Equipped!
Model RCV232WUT-FHS
Standard Product Features
R-Series: Stainless Steel Exterior & Interior
A-Series: Stainless Steel Exterior/Anodized Aluminum Interior
Microprocessor Control System
Balanced, Self-Contained Refrigeration System Using R-404A
Scroll Blower Type Evaporator Fan
Biased Return Air Duct
Full or Half Length Stainless Steel Doors With Locks
Self-Closing Doors With Stay Open Feature At 120 Degrees
Guaranteed For Life Cam-Lift Hinges
Guaranteed For Life Horizontal Work Flow Door Handle
Standard Door Hinging: 132W = Right, 232W = Left/Right
Automatically Activated Incandescent Lights
Stainless Steel Breaker Caps
Three Chrome Plated Adjustable Shelves Per Section,
Supported On Shelf Pins (installed at the factory)
Automatic Non-Electric Condensate Evaporator
Magnetic Snap-In Door Gaskets
Gasket Protecting Metal Door Liner
Controllable Anti-Condensate Door Perimeter Heaters
Thermostatic Expansion Valve Metering Device
Stainless Steel One-Piece Louver Assembly
9' Cord & Plug Attached
Set of Four (4) 6" High Adjustable Stainless Steel Legs
One Year Parts And Labor Warranty
Two Year Control Warranty (parts and labor)
Five Year Compressor Warranty
One & Two Section "W-Width" Models, 32" Deep
1-Section Full Length Door Model RCV132WUT-FHS 2-Section Full Length Door Model RCV232WUT-FHS
R
SERIES
SERIES
1-Section Half Length Door Model RCV132WUT-HHS 2-Section Half Length Door Model RCV232WUT-HHS
1-Section Full Length Door Model ACV132WUT-FHS 2-Section Full Length Door Model ACV232WUT-FHS
A
1-Section Half Length Door Model ACV132WUT-HHS 2-Section Half Length Door Model ACV232WUT-HHS
Options & Accessories
Stainless Steel Finished Back With Rear Louvers
Re-Hinging Feature For Door(s)
No. 1 Type Tray Slides To Accommodate either (1) 18" x 26"
or (2) 14" x 18" Sheet Pans, Adjustable To 2" O.C.
No. 2 Type Tray Slides To Accommodate (1) 18" x 26" Sheet Pans, Adjustable To 2" O.C.
No. 3 Type Tray Slides To Accommodate (2) 12" x 20" Steam Table Pans, Adjustable To 2" O.C.
No. 4 Type Tray Slides To Accommodate (1) 18" x 26" Sheet Pans (chrome rod type, equips 1/2 section)
Universal Type Tray Slides To Accommodate Either (1) 18" x 26" or (2) 14" x 18" Sheet Pans, or (2) 12" x 20" Steam Table Pans, Adjustable To 4" O.C.
Additional Chrome Plated Shelves
Locking Hasps (padlocks supplied by others)
Stainless Steel Shelves In Lieu of Standard Chrome Plated
Kool Klad Exterior Laminate Decor
Set of Four (4) 6" High Casters In Lieu of Legs
Set of Four (4) 4-5/8" High Casters In Lieu of Legs
4-1/2" High Stainless Steel Base In Lieu of Legs
6" High Stainless Steel Kickplate (for use with standard legs)
Prison/Correctional Facilities Options
Remote Applications
Two Year Service/Labor Warranty Available
Full load amps and plug style may vary depending on electrical op­tions chosen and condensing unit employed.
R
AW-03118
Listed by Underwriters Laboratories Inc., and classified by Underwriters Laboratories Inc., in accordance with ANSI/NSF7.
TRAULSEN 4401 BLUE MOUND RD. FT. WORTH, TX 76106 PHONE 1 (800) 825-8220 FAX-MKTG. 1 (817) 624-4302 Website: www.traulsen.com
Approval: __________________________________
SECTION
7-8
Project Quantity Item #
Model Specified: CSI Section 11400
Construction, Hardware and Insulation
Specifications
Cabinet exterior, including front, one piece sides, louver assembly and doors are constructed of heavy gauge stainless steel. Cabinet interior and door liners are constructed of stainless steel (anodized aluminum in the A-Series). Exterior cabinet top, back and bottom are constructed of heavy gauge aluminized steel. Adjustable 6" high stainless steel legs are included.
Doors are equipped with removable plug cylinder locks and guaranteed for life cam-lift, gravity action, self-closing metal, glide hinges with stay open feature at 120 degrees. Hinges include a switch to automatically activate the interior incandescent lighting. Guaranteed for life, work flow door handle is mounted horizontally over recess in door which limits protrusion from door face into aisleways.
Easily removable for cleaning, vinyl magnetic door gasket assures tight door seal. Anti condensate heaters are located behind each door opening.
Cabinet and door contains high density, non-CFC, foamed in place polyurethane insulation.
DIMENSIONAL DATA R/ACV132WUT R/ACV232WUT
Net capacity cu. ft. 24.2 (686 cu l) 51.6 (1462 cu l) Length - overall in. 297⁄8 (75.9 cm) 58 (147.3 cm) Depth - overall in. 35 (88.8 cm) 35 (88.8 cm) Depth - over body in. 32 (81.3 cm) 32 (81.3 cm) Depth - with door open 5711⁄16 (146.5 cm) 5711⁄16(146.5 cm)
90 degrees in. Clear door width in. 211⁄8 (53.6 cm) 211⁄8 (53.6 cm) Clear half-door height in. 271⁄2 (69.9 cm) 271⁄2 (69.9 cm) Clear full-door height in. 575⁄8 (146.3 cm) 575⁄8 (146.3 cm) Height - overall on 6" legs 831⁄4 (211.5 cm) 831⁄4 (211.5 cm) Shelf area sq. ft. 18.8 (1.75 sq m) 37.6 (3.49 sq m) RCV Net Wt. lbs. 415 (188 kg) 705 (320 kg) ACV Net Wt. lbs. 365 (166 kg) 625 (283 kg)
ELECTRICAL DATA
Voltage 115/60/1 115/60/1 Feed wires with Ground 3 3 Full load amperes 11.5 14.9
1
Wattage
REFRIGERATION DATA
Refrigerant R-404A R-404A BTU/HR H.P.
NOTE: Figures in parentheses reflect metric equivalents. 1=Wattage is determined by listed amps X listed volts X an average run time of 70% for refrigerators and 80% for freezers. 2=Based on a 90 degree F ambient and -10 degree F evaporator. 3=For approximate remote weights deduct 40 lbs. from respective net or gross weight.
For other information on remote models, please refer to spec sheet 12-2.
2
1058 1371
2160 (1⁄2 HP) 3790 (3⁄4 HP)
NOTES
Refrigeration System
A top mounted, self-contained, balanced refrigeration system using R-404A refriger­ant is conveniently located behind the one piece louver assembly. It features a ple­num effect blower coil, large, high humidity evaporator coil located outside the food zone, top mounted non-electric condensate evaporator, and an automatic preset time activated electric defrost. A face mounted key switch is provided to convert operation from freezer to refrigerator mode. Standard operating tempera­ture in freezer mode is 0 to -5°F. Operating temperature in refrigerator mode is 34 to 38°F. Operating temperatures are not adjustable.
Controller
The water resistant digital microprocessor control is provided. It includes an 3-digit LED temperature display in addition to features such as a defrost lock-outs and indicator light.
Interior
Standard interior arrangements include three (3) chrome plated wire shelves per section, mounted on shelf pins. Shelves are full-width, and do not have any large gaps between them requiring the use of "bridge" or "junior shelves." Recommended load limit per shelf should not exceed 225 lbs. Optional tray slides may be purchased in combination with, or in lieu of these. Both standard and optional interior arrangements are completely installed at the factory.
Warranties
Both a one year parts and labor warranty and a five year compressor warranty (self­contained models only) are provided standard. An optional 2 and labor warranty is also available. In addition the microprocessor control is warranted by a two year parts and labor warranty.
Elevation -
R/ACV132WUT
Plan - R/ACV132WUT
R/ACV232WUT
Plan - R/ACV232WUT
nd
year extended parts
Elevation -
Equipped With One NEMA 5-15P Plug (1 Section Models Only)
Equipped With One NEMA 5-20P Plug (2 Section Models Only)
NOTE: When ordering please specify: Voltage, Hinging, Door Size, Options and any additional warranties. For fast order entry: Fax 1 (800) 765-8728.
Continued product development may necessitate specification changes without notice. Part No. TR35815 (created 1/07)
TRAULSEN
SECTION
7-8
4401 BLUE MOUND RD. FT. WORTH, TX 76106 PHONE 1 (800) 825-8220 FAX-MKTG. 1 (817) 624-4302 Website: www.traulsen.com
Section - All Models
In order to assure optimum performance, the condensing unit MUST have an adequate supply of air for cooling purposes. Therefore, the operating location must either have a minimum of 12 clearance overhead of the condensing unit or allow for unrestricted air flow at the back of the unit. Clearance of at least 12 above is required in order to perform certain maintenance tasks.
REQUIRED CLEARANCES