Project Quantity Item #
Model Specified: CSI Section 11400
Convertible Reach-In Freezer
Models/Self-Contained
Microprocessor
Equipped!
Model RCV232WUT-FHS
Standard Product Features
• R-Series: Stainless Steel Exterior & Interior
• A-Series: Stainless Steel Exterior/Anodized Aluminum Interior
• Microprocessor Control System
• Balanced, Self-Contained Refrigeration System Using R-404A
• Scroll Blower Type Evaporator Fan
• Biased Return Air Duct
• Full or Half Length Stainless Steel Doors With Locks
• Self-Closing Doors With Stay Open Feature At 120 Degrees
• Guaranteed For Life Cam-Lift Hinges
• Guaranteed For Life Horizontal Work Flow Door Handle
• Standard Door Hinging: 132W = Right, 232W = Left/Right
• Automatically Activated Incandescent Lights
• Stainless Steel Breaker Caps
• Three Chrome Plated Adjustable Shelves Per Section,
Supported On Shelf Pins (installed at the factory)
• Automatic Non-Electric Condensate Evaporator
• Magnetic Snap-In Door Gaskets
• Gasket Protecting Metal Door Liner
• Controllable Anti-Condensate Door Perimeter Heaters
• Thermostatic Expansion Valve Metering Device
• Stainless Steel One-Piece Louver Assembly
• 9' Cord & Plug Attached
• Set of Four (4) 6" High Adjustable Stainless Steel Legs
• One Year Parts And Labor Warranty
• Two Year Control Warranty (parts and labor)
• Five Year Compressor Warranty
One & Two Section "W-Width" Models, 32" Deep
1-Section Full Length Door Model RCV132WUT-FHS
2-Section Full Length Door Model RCV232WUT-FHS
R
SERIES
SERIES
What is a “CONVERTIBLE CABINET?” A convertible cabinet is a reach-
in freezer which, with the use of a key switch, can change itself into a
refrigerator. This two temperature ability allows the operator to
maximize either their refrigerated or frozen storage space as needed,
providing them with additional flexibility in order to manage changing
menus and product types. They are supplied standard with all the Traulsen
top of the line features, such as balanced refrigeration systems, next
generation microprocessor controls and stainless steel exteriors.
1-Section Half Length Door Model RCV132WUT-HHS
2-Section Half Length Door Model RCV232WUT-HHS
1-Section Full Length Door Model ACV132WUT-FHS
2-Section Full Length Door Model ACV232WUT-FHS
A
1-Section Half Length Door Model ACV132WUT-HHS
2-Section Half Length Door Model ACV232WUT-HHS
Options & Accessories
• Stainless Steel Finished Back With Rear Louvers
• Re-Hinging Feature For Door(s)
• No. 1 Type Tray Slides To Accommodate either (1) 18" x 26"
or (2) 14" x 18" Sheet Pans, Adjustable To 2" O.C.
• No. 2 Type Tray Slides To Accommodate (1) 18" x 26" Sheet
Pans, Adjustable To 2" O.C.
• No. 3 Type Tray Slides To Accommodate (2) 12" x 20" Steam
Table Pans, Adjustable To 2" O.C.
• No. 4 Type Tray Slides To Accommodate (1) 18" x 26" Sheet
Pans (chrome rod type, equips 1/2 section)
• Universal Type Tray Slides To Accommodate Either (1)
18" x 26" or (2) 14" x 18" Sheet Pans, or (2) 12" x 20" Steam
Table Pans, Adjustable To 4" O.C.
• Additional Chrome Plated Shelves
• Locking Hasps (padlocks supplied by others)
• Stainless Steel Shelves In Lieu of Standard Chrome Plated
• Kool Klad Exterior Laminate Decor
• Set of Four (4) 6" High Casters In Lieu of Legs
• Set of Four (4) 4-5/8" High Casters In Lieu of Legs
• 4-1/2" High Stainless Steel Base In Lieu of Legs
• 6" High Stainless Steel Kickplate (for use with standard legs)
• Prison/Correctional Facilities Options
• Remote Applications
• Two Year Service/Labor Warranty Available
Full load amps and plug style may vary depending on electrical options chosen and condensing unit employed.
R
AW-03118
Listed by Underwriters Laboratories Inc.,
and classified by Underwriters Laboratories
Inc., in accordance with ANSI/NSF7.
TRAULSEN
4401 BLUE MOUND RD. FT. WORTH, TX 76106
PHONE 1 (800) 825-8220 FAX-MKTG. 1 (817) 624-4302
Website: www.traulsen.com
Approval: __________________________________
SECTION
7-8
Project Quantity Item #
Model Specified: CSI Section 11400
Construction, Hardware and Insulation
Specifications
Cabinet exterior, including front, one piece sides, louver assembly and doors are
constructed of heavy gauge stainless steel. Cabinet interior and door liners are
constructed of stainless steel (anodized aluminum in the A-Series). Exterior cabinet
top, back and bottom are constructed of heavy gauge aluminized steel. Adjustable
6" high stainless steel legs are included.
Doors are equipped with removable plug cylinder locks and guaranteed for life
cam-lift, gravity action, self-closing metal, glide hinges with stay open feature at 120
degrees. Hinges include a switch to automatically activate the interior incandescent
lighting. Guaranteed for life, work flow door handle is mounted horizontally over
recess in door which limits protrusion from door face into aisleways.
Easily removable for cleaning, vinyl magnetic door gasket assures tight door seal.
Anti condensate heaters are located behind each door opening.
Cabinet and door contains high density, non-CFC, foamed in place polyurethane
insulation.
DIMENSIONAL DATA R/ACV132WUT R/ACV232WUT
Net capacity cu. ft. 24.2 (686 cu l) 51.6 (1462 cu l)
Length - overall in. 297⁄8 (75.9 cm) 58 (147.3 cm)
Depth - overall in. 35 (88.8 cm) 35 (88.8 cm)
Depth - over body in. 32 (81.3 cm) 32 (81.3 cm)
Depth - with door open 5711⁄16 (146.5 cm) 5711⁄16(146.5 cm)
90 degrees in.
Clear door width in. 211⁄8 (53.6 cm) 211⁄8 (53.6 cm)
Clear half-door height in. 271⁄2 (69.9 cm) 271⁄2 (69.9 cm)
Clear full-door height in. 575⁄8 (146.3 cm) 575⁄8 (146.3 cm)
Height - overall on 6" legs 831⁄4 (211.5 cm) 831⁄4 (211.5 cm)
Shelf area sq. ft. 18.8 (1.75 sq m) 37.6 (3.49 sq m)
RCV Net Wt. lbs. 415 (188 kg) 705 (320 kg)
ACV Net Wt. lbs. 365 (166 kg) 625 (283 kg)
ELECTRICAL DATA
Voltage 115/60/1 115/60/1
Feed wires with Ground 3 3
Full load amperes 11.5 14.9
1
Wattage
REFRIGERATION DATA
Refrigerant R-404A R-404A
BTU/HR H.P.
NOTE: Figures in parentheses reflect metric equivalents.
1=Wattage is determined by listed amps X listed volts X an average run time of 70%
for refrigerators and 80% for freezers.
2=Based on a 90 degree F ambient and -10 degree F evaporator.
3=For approximate remote weights deduct 40 lbs. from respective net or gross weight.
For other information on remote models, please refer to spec sheet 12-2.
2
1058 1371
2160 (1⁄2 HP) 3790 (3⁄4 HP)
NOTES
Refrigeration System
A top mounted, self-contained, balanced refrigeration system using R-404A refrigerant is conveniently located behind the one piece louver assembly. It features a plenum effect blower coil, large, high humidity evaporator coil located outside the food
zone, top mounted non-electric condensate evaporator, and an automatic
preset time activated electric defrost. A face mounted key switch is provided to
convert operation from freezer to refrigerator mode. Standard operating temperature in freezer mode is 0 to -5°F. Operating temperature in refrigerator mode is 34 to
38°F. Operating temperatures are not adjustable.
Controller
The water resistant digital microprocessor control is provided. It includes an 3-digit
LED temperature display in addition to features such as a defrost lock-outs and
indicator light.
Interior
Standard interior arrangements include three (3) chrome plated wire shelves per
section, mounted on shelf pins. Shelves are full-width, and do not have any large
gaps between them requiring the use of "bridge" or "junior shelves." Recommended
load limit per shelf should not exceed 225 lbs. Optional tray slides may be
purchased in combination with, or in lieu of these. Both standard and optional
interior arrangements are completely installed at the factory.
Warranties
Both a one year parts and labor warranty and a five year compressor warranty (selfcontained models only) are provided standard. An optional 2
and labor warranty is also available. In addition the microprocessor control is
warranted by a two year parts and labor warranty.
Elevation -
R/ACV132WUT
Plan - R/ACV132WUT
R/ACV232WUT
Plan - R/ACV232WUT
nd
year extended parts
Elevation -
Equipped With One NEMA 5-15P Plug
(1 Section Models Only)
Equipped With One NEMA 5-20P Plug
(2 Section Models Only)
NOTE: When ordering please specify: Voltage, Hinging, Door Size, Options and any
additional warranties. For fast order entry: Fax 1 (800) 765-8728.
Continued product development may necessitate specification changes without notice.
Part No. TR35815 (created 1/07)
TRAULSEN
SECTION
7-8
4401 BLUE MOUND RD. FT. WORTH, TX 76106
PHONE 1 (800) 825-8220 FAX-MKTG. 1 (817) 624-4302
Website: www.traulsen.com
Section - All Models
In order to assure optimum performance, the condensing unit MUST have an adequate supply of
air for cooling purposes. Therefore, the operating location must either have a minimum of 12”
clearance overhead of the condensing unit or allow for unrestricted air flow at the back of the unit.
Clearance of at least 12” above is required in order to perform certain maintenance tasks.
REQUIRED CLEARANCES