separators and other similar plumbing devices receiving kitchen ows from sinks, oor drains,
woks and other food bearing sources may generate odors. There are many factors inuencing
odor evolution and dissemination. These include room ventilation, kitchen menu, ambient tem-
plumbing design and product maintenance/upkeep. Odors are usually prevented by good area
ventilation, frequent uid inputs, good product maintenance practices and proper product installation. Additional steps, including aeration, chlorination, improved area ventilation and additional
maintenance control, may be needed at some sites.
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651
MNL-TSS 3
Section II: Models and Options
1
2
1
2
1
2
3
A THERMACO® Technology
In-Ground Models
TSS-95-ECA
95 gallons of solids retention capacity, capable of handling
ow rates of up to 150 gpm. Equipped with 4” inlet/outlet,
2” vessel vent connection, and 4” Low-Head Flow Control
Accessory to limit ow to 75 gpm.
Comes with: 18” tall Extension Collar Adapter Lid
Assembly with 22” diameter lid.
TSS-70-ECA
70 gallons of solids retention capacity, capable of handling
ow rates of up to 75 gpm. Equipped with 4” inlet/outlet,
2” vessel vent connection, and 4” Low-Head Flow Control
Accessory to limit ow to 75 gpm.
Comes with: 18” tall Extension Collar Adapter Lid
Assembly with 22” diameter lid.
TSS-27-ECA
27 gallons of solids retention capacity, capable of handling
ow rates of up to 35 gpm. Equipped with 3” inlet/outlet,
2” vessel vent connection, and 3” Low-Head Flow Control
Accessory to limit ow to 35 gpm.
Comes with: 22” diameter lid and 29” Telescoping
Extension Collar.
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651
MNL-TSS 4
Section II: Models and Options
1
2
3
4
1
2
3
1
2
A THERMACO® Technology
Above-Ground Models
TSS-95-SSA
95 gallons of solids retention capacity, capable of handling
ow rates of up to 150 gpm. Equipped with 4” inlet/outlet,
2” vessel vent connection, and 4” Low-Head Flow Control
Accessory to limit ow to 75 gpm.
Comes with: Standard Adapter Top Cover with 22”
diameter lid, and SSOP-70/95 for above-ground
installation.
TSS-70-SSA
70 gallons of solids retention capacity, capable of handling
ow rates of up to 75 gpm. Equipped with 4” inlet/outlet,
2” vessel vent connection, and 4” Low-Head Flow Control
Accessory to limit ow to 75 gpm.
Comes with: Standard Adapter Top Cover with 22”
diameter lid, and SSOP-70/95 for above ground
installation.
TSS-27-SSA
27 gallons of solids retention capacity, capable of handling
ow rates of up to 35 gpm. Equipped with 3” inlet/outlet,
2” vessel vent connection, and 3” Low-Head Flow Control
Accessory to limit ow to 35 gpm.
Comes with: 22” diameter lid and Support Stand
SSA-160.
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651
MNL-TSS 5
Section II: Models and Options
1
2
3
1
2
A THERMACO® Technology
Basic Models
TSS-95
95 gallons of solids retention capacity, capable of handling
ow rates of up to 150 gpm. Equipped with 4” inlet/outlet,
2” vessel vent connection, and 4” Low-Head Flow Control
Accessory to limit ow to 75 gpm.
Comes with: Standard Adapter Top Cover with 22”
diameter lid.
TSS-70
70 gallons of solids retention capacity, capable of handling
ow rates of up to 75 gpm. Equipped with 4” inlet/outlet,
2” vessel vent connection, and 4” Low-Head Flow Control
Accessory to limit ow to 75 gpm.
Comes with: Standard Adapter Top Cover with 22”
diameter lid.
TSS-27
27 gallons of solids retention capacity, capable of handling
ow rates of up to 35 gpm. Equipped with 3” inlet/outlet,
2” vessel vent connection, and 3” Low-Head Flow Control
Accessory to limit ow to 35 gpm.
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651
MNL-TSS 7
Section III: TSS Installation
A THERMACO® Technology
Locating the Unit
The system should be visible and easily accessible for maintenance and inspection. Options
are available to install Trapzilla Solids Separators in a basement, suspended from a ceiling
or in-ground in an exterior location. Make sure
adequate room is provided around the unit to
allow easy access for a pump truck operator.
Make sure the height above the Trapzilla access
cover is enough to properly service the system.
Inlet/Outlet Piping
The inlet and outlet piping connections require
exible sleeve pipe couplings. Keep outlet
piping as straight as possible. Thermaco, Inc.
recommends installation of 4” (100 mm) Two-
Way Cleanouts on both the Inlet and Outlet of
Trapzilla Interceptors and Solids Separators in
accordance with all applicable laws, regulations
and codes. Use only “sweep” connections. Do
not reduce the pipe sizing on the outlet piping.
Do not install “P” trap on outlet connection of
system. (Note: The system already has a internal gas trap)
Flow Controls
Trapzilla systems are supplied with a Low-Head
Flow Control module (LHFC-4). This should be
connected to the inlet of the Trapzilla unit in situ-
ations where ow rate needs to be restriced to
75 GPM or when vented ow control is required
by local code.
Plumbing Installation
Venting the Outlet
An outlet vent or approved air admittance valve
of at least 1/2 the diameter of the system’s outlet
connection must be present as close as possible
to the Trapzilla outlet to prevent possible siphonage problems. The Vent on the Outlet piping is
to be installed in accordance with all applicable
laws, regulations and codes. Failure to provide
a vent for the system voids Thermaco’s Limited
Warranty for the system.
For High Head Height Applications
Over Six (6) Feet (1.95 m)
For installations where there is head height of
greater than 6 feet (1.95 meters), Thermaco,
Inc. recommends installation of a code-approved