TransTel Communications Lynx DK Series, Lynx DK7, Lynx DK6-36, Lynx DK6-18, Lynx DK6 Series Master Programming Manual

Telephone System
Master Programming Manual
Rev 2.1c
Notification
Notification is hereby given that TransTel Communications, Inc. reserves the right to modify, change, update or revise this document from time to time as required without the prior obligation to notify any person, company or organization. Further, TransTel Communications, Inc. makes no warranty or representation, either express or implied, with respect to merchantability, or fitness of its products for a particular purpose.
2009-2011 TransTel Communications, Inc.
This document or any parts thereof are not to be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or information storage and retrieval systems for any purpose whatsoever without the express written permission of TransTel Communications, Inc. .
Revision History
Date of Release Revision Description 2009 1.1 First Revision Manual 2010-03-18 2.0a Operation of Voice Mail clarified 2010-04-05 2.0b Change to MSG function and 46-st-02 2011-07-29 2.1b Update to G1-A20L+ 2011-10-19 2.1c Update to G1-A20Q+
Revision Note:
LYNX Plus Programming Manual Rev 2.1c Page
3
Table of Contents
General Description - Introduction ............................................................................................................................15
FCC Rules and Regulation .........................................................................................................................................15
FCC Registration Number .........................................................................................................................................15
Ringer Equivalence Number 0.3B. ...........................................................................................................................15
Notification of the Telephone Company.....................................................................................................................15
Direct Connection to a Party-Line or Coin Operated Telephone Line is Prohibited...................................................15
Incidence of Harm to the Telephone Lines ................................................................................................................15
Compatibility of the Telephone Network and Terminal Equipment............................................................................16
Radio Frequency Interference ...................................................................................................................................16
CTR 21 (98/482/EC) Declaration Network Compatibility..........................................................................................16
Economy and Efficiency ............................................................................................................................................17
Easy Installation.........................................................................................................................................................17
Easy Maintenance .....................................................................................................................................................17
Flexibility of System Applications...............................................................................................................................17
Varied Extension Alternatives....................................................................................................................................18
Liquid Crystal Display ................................................................................................................................................19
Mechanical Specifications (Key Service Unit) ...........................................................................................................20
Mechanical Specifications (Battery Back Up Housing)..............................................................................................20
Environmental Specifications.....................................................................................................................................20
Features .......................................................................................................................................................................21
System Features........................................................................................................................................................21
Station Features ..........................................................................................................................................................22
Parts & Peripherals .....................................................................................................................................................23
System Modules ........................................................................................................................................................23
Type of Phones..........................................................................................................................................................23
Peripheral Devices.....................................................................................................................................................23
Optional Interface Cards............................................................................................................................................23
System Installation - Introduction .............................................................................................................................25
Site Requirements.......................................................................................................................................................25
Site Requirements.......................................................................................................................................................26
Location .....................................................................................................................................................................26
Choosing the Right Environment ...........................................................................................................................26
Installation Checklist ..................................................................................................................................................26
Equipment Requirements...........................................................................................................................................26
Installation ...................................................................................................................................................................26
Installing expansion and optional cards.....................................................................................................................27
Card Introduction ........................................................................................................................................................27
G1K-PWU-Power Supply Interface Card...................................................................................................................27
G1K-MBU2 Main Board Unit......................................................................................................................................28
G1K-TLU 2 Port CO Line and 4 Port SLT .................................................................................................................29
Page 4
G1K-NFC 128 ...........................................................................................................................................................29
Install G1K-TLU 2 CO line 4 port SLT....................................................................................................................... 30
Installing the Equipment ............................................................................................................................................ 31
Backboard .................................................................................................................................................................31
Key Service Unit........................................................................................................................................................ 31
Power Supply ............................................................................................................................................................31
Check Your power adapter....................................................................................................................................31
Mount Power adapter................................................................................................................................................ 31
Preparing The External Battery Backup.................................................................................................................... 31
Charging the Battery .................................................................................................................................................32
Installing or Replacing Batteries................................................................................................................................ 32
Caution ..................................................................................................................................................................32
KSU Connecting (Main) Panel Layout ......................................................................................................................32
Connecting Stations................................................................................................................................................... 32
Digital Key Telephone –DK6 - DK7......................................................................................................................... 33
Access Control Telephone/Door Phone – ACP/DPU................................................................................................ 35
Single Line Telephone (connected to G1K-MBU) ..................................................................................................... 36
Music on Hold Connection ........................................................................................................................................36
Optional Cabling ......................................................................................................................................................... 37
Door Switch (Relay) Connection ............................................................................................................................... 37
Sensor Connection.................................................................................................................................................... 37
RS232 Port Connection.............................................................................................................................................38
VMU Setup................................................................................................................................................................ 38
External Music on Hold Source................................................................................................................................. 38
Power On and Operational Test ................................................................................................................................39
Operational Tests...................................................................................................................................................... 39
Special Immunity Protection for System and terminals .........................................................................................39
Introduction................................................................................................................................................................. 41
New Systems ............................................................................................................................................................41
Basic Programming Commands ...............................................................................................................................42
Enter Programming: ..............................................................................................................................................42
Alphanumeric Entry:.................................................................................................................................................. 43
DK6 Key Telephone – Key Layout (36 Button)..........................................................................................................43
DK6 Key Telephone – Key Layout (18 Button)..........................................................................................................44
DK7 Key Telephone – Key Layout ............................................................................................................................44
LYNX System Setup ...................................................................................................................................................45
Program 01-tk-IP : Day Ringing And Ringing Line Preference Assignment........................................................ 46
Program 02-tk-IP : Night Ringing And Ringing Line Preference Assignment ..................................................... 46
Program 03-01-IP : Door Phone Ringing Assignment............................................................................................ 47
Program 04-gp-IP : Console Assignment................................................................................................................ 47
Program 05-01-IP : System Timing Parameters – 01............................................................................................... 48
LYNX Plus Programming Manual Rev 2.1c Page
5
01. Hold Recall Time .................................................................................................................................................48
02. Exclusive Hold Recall Time .................................................................................................................................48
03. Hold Recall Timeout ............................................................................................................................................48
04. DISA & ECF Access Delay Time - Day ...............................................................................................................49
05. Busy Remind Cycle Time (Off-Hook Ringing) .....................................................................................................49
06. Pause Time..........................................................................................................................................................49
07. DTMF Generation Time .......................................................................................................................................49
08. Call Forward No Answer Transfer Time ..............................................................................................................50
Program 05-02-IP : System Timing Parameters – 02 ..............................................................................................51
01. SLT Dial Tone Timeout........................................................................................................................................51
02. SLT Inter-Digit Timeout .......................................................................................................................................51
03. Auto Redial Access Time – PSTN Lines .............................................................................................................51
04. SLT Release Signal Time ....................................................................................................................................52
05. PSTN Line Flash Time - Key Phone & Analog Phone.........................................................................................52
06. SLT Hold Signal Time..........................................................................................................................................52
07. Ring On Time.......................................................................................................................................................52
08. Ring Off Time ......................................................................................................................................................52
Program 05-03-IP : System Timing Parameters – 03 ..............................................................................................53
01. Make/Break Ratio ................................................................................................................................................53
02. Automatic Trunk Search ......................................................................................................................................53
03. Intercom Call Signalling Method ..........................................................................................................................53
04. PABX (Centrex) Outgoing Code: (Refer to Program 35-TK-01)..........................................................................53
05. Toll Access Code.................................................................................................................................................54
06. Station Numbering Plan.......................................................................................................................................54
07. Internal Dial Tone Pattern....................................................................................................................................54
08. Door Phone Ring Pattern.....................................................................................................................................54
Program 05-04-IP : System Timing Parameters – 04 ..............................................................................................55
01. System Baud Rate Setting...................................................................................................................................55
02. Dial 9 Flag............................................................................................................................................................55
03. Action for Call Duration Limiting ..........................................................................................................................55
04. 12/24 Hours Clock ...............................................................................................................................................56
05. SLT Hook Flash Answer Delay............................................................................................................................56
06. Speed Dialling Distribution...................................................................................................................................56
07. Single Digit Intercom............................................................................................................................................56
08. SLT Message Waiting Method ............................................................................................................................57
Program 05-05-IP : System Timing Parameters – 05 ..............................................................................................58
01. Morning Call.........................................................................................................................................................58
02. Reserved .............................................................................................................................................................58
03, 04. Speed Dial Unrestricted - 1, 2........................................................................................................................58
05. Name Function ....................................................................................................................................................59
06. Reserved .............................................................................................................................................................59
07. Auto Redial Trials ................................................................................................................................................59
08. Auto Redial Pause Time ......................................................................................................................................59
Program 05-06-IP : System Timing Parameters – 06 ..............................................................................................60
01. Transfer Busy Recall Time ..................................................................................................................................60
02. Transfer Idle Recall Time ....................................................................................................................................60
03. ISDN Audio Coding (a-law orµ- law)....................................................................................................................60
04. Polarity Reversal..................................................................................................................................................61
05. Operator Code .....................................................................................................................................................61
06. Unsupervised Conference & ECF Time Setting ..................................................................................................61
Page 6
07. Hold Feature for SLT........................................................................................................................................... 61
08. Station Hunting Group - Ring Method: ................................................................................................................62
Program 05-07-IP : System Timing Parameters – 07.............................................................................................. 63
01. Intercom Searching .............................................................................................................................................63
02. Toll Override Prevention from Quick Dial............................................................................................................ 63
03. Paging Alert Tone................................................................................................................................................63
04. DISA Recall To Console - No Dialling................................................................................................................. 64
05. Key Phone Toll Override Prevention................................................................................................................... 64
06. SMDR Digit Mask................................................................................................................................................ 64
07. Guard Time for CO Line Re-accessing............................................................................................................... 64
08. Reserved............................................................................................................................................................. 64
Program 05-08-IP : System Timing Parameters – 08.............................................................................................. 65
01. Ring Hunt Time ...................................................................................................................................................65
02. DSS Access to Other Trunk Group..................................................................................................................... 65
03. SLT Camp on Time.............................................................................................................................................65
04. Console of DISA Transfer Group for No Answer ................................................................................................ 66
05. SLT Programming Digit....................................................................................................................................... 66
06. DISA Transfer Time No Answer.......................................................................................................................... 66
07. DISA Transfer Time - No Dialling........................................................................................................................ 66
08. Music Source Selection....................................................................................................................................... 67
Program 05-09-IP : System Timing Parameters – 09.............................................................................................. 68
02. Console Queuing.................................................................................................................................................68
03. Clear Forward Signal (Loop Disconnect) Detection ............................................................................................ 68
04. DISA Busy Tone Detection..................................................................................................................................69
05. Reserved............................................................................................................................................................. 69
06. ACD-1 Enable Time ............................................................................................................................................69
07. ACD-1 Segment 2 Recall Time ........................................................................................................................... 69
08. ACD-1 Release Time ..........................................................................................................................................70
Program 05-10-IP : System Timing Parameters – 10.............................................................................................. 71
Program 05-11-IP : System Timing Parameters – 11.............................................................................................. 73
0.1 DTMF Caller ID Leading Digit .............................................................................................................................73
02. Number of DISA Passwords ...............................................................................................................................73
03. Select Music on Hold or Ring Back Tone............................................................................................................ 73
04. DISA & ECF Access Delay Time – Night ............................................................................................................ 74
05: DISA Special Function Access............................................................................................................................ 74
06. DISA Re-check Times To Station/Console .........................................................................................................74
07. Door Phone Ringing Time................................................................................................................................... 74
08. DISA Single Digit Dialling.................................................................................................................................... 75
Program 05-12-IP : System Timing Parameters – 12.............................................................................................. 76
01. Call Transfer Method – Key Telephone ..............................................................................................................76
02. Reserved............................................................................................................................................................. 76
03. Exclusive Hold Capability.................................................................................................................................... 76
04. Door Relay Activation Time................................................................................................................................. 77
05. Voice Mail Call Forward Protocol Selection and Muting Leading Digits.............................................................. 77
06. Linear / Circular Trunk Group Access................................................................................................................. 78
07. LED Indication of Check In / Check Out ............................................................................................................. 78
08. Reserved............................................................................................................................................................. 78
Program 05-13-IP : System Timing Parameters – 13.............................................................................................. 79
LYNX Plus Programming Manual Rev 2.1c Page
7
01. Intercom Hot Key Dialling ....................................................................................................................................79
02. Immediate SMDR Output ....................................................................................................................................79
03 Caller ID Buffer Block Size ...................................................................................................................................80
04. Reserved .............................................................................................................................................................80
05. CLI Record Storing Method for LCD Phones.......................................................................................................80
06. CTI-Trunk Status Report .....................................................................................................................................80
07. Least Cost Routing – Weekly Holiday 1 ..............................................................................................................80
08. Least Cost Routing – Weekly Holiday 2 ..............................................................................................................80
Program 05-14-IP : System Timing Parameters – 14 ..............................................................................................81
01. SLT LCR Switch on Delay for PSTN ...................................................................................................................81
02. Reserved 03. Reserved 04. Reserved.................................................................................................................81
05. DISA DTMF Detect Delay Time...........................................................................................................................81
06. CLI Delay Ring Time............................................................................................................................................81
07. Reserved 08. Reserved .......................................................................................................................................81
Program 05-15-IP : System Timing Parameters – 15 ..............................................................................................82
01. Company Greeting Time......................................................................................................................................82
02. Reserved 03. Reserved .......................................................................................................................................82
Program 05-16-IP : System Timing Parameters – 16 ..............................................................................................83
01. Midnight Reset.....................................................................................................................................................83
02. Reserved .............................................................................................................................................................83
03. DISA Single Digit Dialing Level............................................................................................................................83
04. VMU Language Service.......................................................................................................................................84
05. Reserved .............................................................................................................................................................84
06. Reserved .............................................................................................................................................................84
07. ACP Data Output Format.....................................................................................................................................84
08. Reserved .............................................................................................................................................................84
Program 05-17-IP : System Timing Parameters – 17 ..............................................................................................85
01. Reserved .............................................................................................................................................................85
02. Voice Compression..............................................................................................................................................85
03. Extension Number Announcement for DISA .......................................................................................................85
04. DISA & ECF Access Delay Time – Lunch ...........................................................................................................86
05. DTMF CLI Leading Digits ....................................................................................................................................86
06. DTMF CLI Trailing Digits .....................................................................................................................................86
07. Call Block or Transfer to Voice Mail according to CLI Message..........................................................................87
08. Minimum Mail Box Record Time..........................................................................................................................87
Program 05-18-IP : System Timing Parameters – 18 ..............................................................................................88
01. Reserved .............................................................................................................................................................88
02. Hotel Alarm ..........................................................................................................................................................88
03. Dial Out History Feature ......................................................................................................................................88
04. Caller ID Compatibility (Canada) .........................................................................................................................89
05. Reserved .............................................................................................................................................................89
06. Play Transfer message for ECF ..........................................................................................................................89
07. High Frequency Level of DTMF Generator..........................................................................................................89
08. Low Frequency Level of DTMF Generator ..........................................................................................................89
Program 05-19-IP : System Timing Parameters – 19 ..............................................................................................90
01. Reserved .............................................................................................................................................................90
02. Reserved .............................................................................................................................................................90
03. Reserved .............................................................................................................................................................90
04. Silence Detection For VMU .................................................................................................................................90
Page 8
05. Reserved............................................................................................................................................................. 90
06. Reserved............................................................................................................................................................. 90
07. Reserved............................................................................................................................................................. 90
08. Reserved............................................................................................................................................................. 90
Program 05-20-IP : System Timing Parameters – 20.............................................................................................. 91
01. VMU Mailbox Delete All Messages ..................................................................................................................... 91
02. DISA No Digits Dialed (End of Message) Destination......................................................................................... 91
03. Number of Available Voice Mail Boxes ...............................................................................................................91
04. Reserved............................................................................................................................................................. 92
05. Reserved............................................................................................................................................................. 92
06. Reserved............................................................................................................................................................. 92
07. Reserved............................................................................................................................................................. 92
08. Reserved............................................................................................................................................................. 92
Program 05-23-IP : System Timing Parameters – 23.............................................................................................. 93
01. Reserved:............................................................................................................................................................ 93
02. Reserved:............................................................................................................................................................ 93
03. Reserved:............................................................................................................................................................ 93
04. Reserved............................................................................................................................................................. 93
06. Reserved:............................................................................................................................................................ 93
07. Reserved:............................................................................................................................................................ 93
08. DSP Reset Reserved: .........................................................................................................................................93
Program 05-24-IP : System Timing Parameters – 24.............................................................................................. 94
01. Reserved:............................................................................................................................................................ 94
02.Reserved:............................................................................................................................................................. 94
03. Reserved:............................................................................................................................................................ 94
04. LYNX Monitor System Tracking .......................................................................................................................... 94
05. Reserved:............................................................................................................................................................ 94
06. LYNX Monitor Output: .........................................................................................................................................94
07. LYNX Monitor DSP trace:....................................................................................................................................95
08. LYNX Monitor VMC Trace:.................................................................................................................................. 95
Program 06-IP : Relay Assignment .......................................................................................................................... 96
Program 07-Gp-IP : Flexible Key Group Assignment............................................................................................. 97
Program 09-nnn-DP : System Speed Dial.............................................................................................................. 100
Program 10-GP-IP : Intercom Single Digit Assignment .......................................................................................102
Program 11-IP : Date and Time Setting .................................................................................................................103
Program 12-nn : System Alarm Clock....................................................................................................................104
Program 13-nn : Password .....................................................................................................................................105
Program 14-01-IP : SMDR Specifications .............................................................................................................. 106
01. Call Duration Start Time.................................................................................................................................... 106
02. Record Incoming Calls ...................................................................................................................................... 106
03. Record Local Calls ............................................................................................................................................106
04. Record Incoming Calls No Answer ...................................................................................................................106
05. Print out the Title ...............................................................................................................................................107
06. Number of Records between the Title............................................................................................................... 107
LYNX Plus Programming Manual Rev 2.1c Page
9
07. Reserved ...........................................................................................................................................................107
08. Polarity Reversal................................................................................................................................................107
Program 17-nn : Forced Account Code .................................................................................................................110
Program 18-nn-TK : Assign Toll Plan To Trunk Lines..........................................................................................111
Program 20-nn- : Set Day – Time / Lunch Time Schedule..................................................................................112
Program 25 : Reset Data to System Default ..........................................................................................................113
Program 29-tk-IP : Trunk Specifications – 2 ..........................................................................................................114
0.1 Trunk Receive Gain ...........................................................................................................................................114
02. ACD-1 Function Enable .....................................................................................................................................114
03. Trunk Transmit Gain..........................................................................................................................................115
04. Set Ring Frequency (DK Handsets) ..................................................................................................................115
05. Allow Audible Ring for Incoming Calls ...............................................................................................................115
06. 1A2 Emulation ...................................................................................................................................................115
07. CO Delayed Ring Timer to Hunting Group ........................................................................................................116
08. CO Delayed Ring Overflow Hunting Group .......................................................................................................116
Program 35-tk-IP : Trunk Specifications – 1 ..........................................................................................................117
01. Trunk Type (CO / PABX) ...................................................................................................................................117
02. Trunk Signal (Pulse / DTMF ) ............................................................................................................................117
03. External Call Forward – ECF .............................................................................................................................118
04. DISA / ECF (Direct Inward System Access / External Call Forward) ................................................................118
05. Pick Up ..............................................................................................................................................................118
06. Loud Bell............................................................................................................................................................119
07. Inward Line Ringing Method Assignment (Day) ................................................................................................119
08. Inward Line Ringing Method Assignment (Night) ..............................................................................................120
To set a trunk name - ..............................................................................................................................................120
Program 36-gp-tk : Trunk Group Assignments.....................................................................................................121
Program 37-tk : Busy Out Trunks ...........................................................................................................................122
Program 38-gp-tk : Dial 87 Trunk Group Assignments ........................................................................................123
Program 39-IP : Sensor Assignments ....................................................................................................................124
Program 40-stn-IP : Station Class of Service – 1 ..................................................................................................125
01. Override Level ...................................................................................................................................................125
02. Monitor Level .....................................................................................................................................................125
03: Limit call duration...............................................................................................................................................125
04. Station Loud Bell................................................................................................................................................126
05. Access Paging ...................................................................................................................................................126
06. Receive Paging..................................................................................................................................................126
07. Security Code Status .........................................................................................................................................126
08. Forced Account Code ........................................................................................................................................126
Program 41-stn-IP : Station Specifications ...........................................................................................................127
01. Station group .....................................................................................................................................................127
02. Flexible key group assignments for Key phone .................................................................................................127
03. Shift Key Group for Key phone ..........................................................................................................................127
04. Dial 9 trunk group/ SLT Port as MOH Source ...................................................................................................128
Page 10
05. Toll plan - Day ...................................................................................................................................................128
06. Toll plan - Night .................................................................................................................................................128
07. Port Number...................................................................................................................................................... 128
Program 42-stn-IP : Register Memory Blocks for Individual Speed Dial ...........................................................129
Program 43-cn-IP : Port Specifications .................................................................................................................130
01. Station Number .................................................................................................................................................130
02. Equipment Type ................................................................................................................................................130
03. Flexible DSS Key Group Assignments for DSS Console.................................................................................. 131
04. Reserved........................................................................................................................................................... 131
05. Voice Mail Box Assignment............................................................................................................................... 131
06. Reserved:.......................................................................................................................................................... 132
Name Entry for Extensions .....................................................................................................................................132
Program 44-stn-IP : Station Class of Service – 2.................................................................................................. 133
01. System Alarm.................................................................................................................................................... 133
02. Hold Feature......................................................................................................................................................133
03. Call Split ............................................................................................................................................................133
04. Manual Line....................................................................................................................................................... 134
05. Headset Feature ...............................................................................................................................................134
06. Use Engineering Password............................................................................................................................... 134
07. Reserved........................................................................................................................................................... 134
08. Station Alarm Signal.......................................................................................................................................... 134
Program 45-stn-IP : Station Class of Service – 3.................................................................................................. 135
01. Intercom Call Limitation..................................................................................................................................... 135
02. ACP Hear BGM at idle state..............................................................................................................................135
03. Incremental Increase Ringing Volume ..............................................................................................................135
04. Allow Trunk Access........................................................................................................................................... 136
05. Intercom Calls to Different Station Groups ....................................................................................................... 136
06. Receive Break Alarm ........................................................................................................................................136
07. Allow Unrestricted Speed Dial Access .............................................................................................................. 136
08. Record Station's SMDR Data............................................................................................................................136
Program 46-stn-IP : Station Class of Service – 4.................................................................................................. 137
01. Dial [87] Trunk Group........................................................................................................................................ 137
02. Message Waiting Level .....................................................................................................................................137
03. Automatic Answer Capability (Keyphone) / Internal CLIP (Caller ID) Function................................................. 138
04. DISA/ISDN In Dial Recall Capability..................................................................................................................138
05. Maximum Re-Transferred Times ......................................................................................................................138
06. Door Unlock / DND / CFWD Access .................................................................................................................139
07. ACP Door Phone Hunt Group / Permanent Call Forward Group – No Answer ................................................139
08. SLT Ring Cadence Settings.............................................................................................................................. 139
Program 47-stn-IP : Hot Line Assignment............................................................................................................. 140
Program 48-stn-IP : Station Class of Service – 5.................................................................................................. 141
01. Reserved........................................................................................................................................................... 141
02. Reserved........................................................................................................................................................... 141
03. Group Listen Feature ........................................................................................................................................141
04. Reserved........................................................................................................................................................... 141
05. Reserved........................................................................................................................................................... 141
06. Reserved........................................................................................................................................................... 141
07. Reserved........................................................................................................................................................... 141
LYNX Plus Programming Manual Rev 2.1c Page
11
08. Reserved ...........................................................................................................................................................141
Program 50-stn-IP : Station Class of Service – 6 ..................................................................................................142
01. ACP Warning Signals ........................................................................................................................................142
02. Call Forward Indication: .....................................................................................................................................142
03. Reserved: ..........................................................................................................................................................142
04. CTI-Extension Status Report .............................................................................................................................142
05. VMS Leading Digits For Intercom Calls.............................................................................................................143
06. ACP Door Unlock Relay ....................................................................................................................................143
07. ACP Door Open Control ....................................................................................................................................143
08. ACP Phone Operation / Hotel Alarm Type ........................................................................................................144
Program (51 to 59)-code-IP : Toll Plans – Allowed Digits – Class 1 to 9 ............................................................145
Program (61 to 66)-code-IP : Toll Plans – Restricted Digits – Class 1 to 6 ........................................................146
Program 67-gp-IP : Hunt Group Pilot Number.......................................................................................................148
01. Hunting Group Pilot Number..............................................................................................................................148
02. Hunting Group Ringing Method .........................................................................................................................148
Program 68-gp-IP : Hunt Group Assignment – Day ..............................................................................................150
Program 69-gp-IP : Station Hunt Group Assignment – Night .............................................................................151
Program 75-Num-IP : LCR - Analysis Table...........................................................................................................152
Program 76-Num-Tm : LCR – Routing Table ..........................................................................................................153
Program 77-Num : LCR – Modifying Table ............................................................................................................154
Program 78-stn-IP : Station Class of Service – 6 ..................................................................................................155
01. LCR Routing Level.............................................................................................................................................155
02. LCR – Direct Access a Trunk ............................................................................................................................155
03. 1A2 Emulation (Station Programming) ..............................................................................................................156
04. Call Forward Busy Transfer Group ....................................................................................................................156
05. External Notification – Voicemail .......................................................................................................................156
06. Calling Line Identification Presentation..............................................................................................................156
07. Ring Line Preference .........................................................................................................................................157
08. Reserved ...........................................................................................................................................................157
Program 83-st-IP : Register Memory Block for CLI history buffer ......................................................................158
Program 84-IP : Home Area Code...........................................................................................................................159
Program 85-nn-IP : Overlay Area Code ..................................................................................................................160
Program 86-nnn-IP : Office Code Redial Pattern ..................................................................................................161
Program 87-CN-IP : ASSIGN DOOR PHONE FOR KEY CARD..............................................................................162
Program 88-DP : REGISTER KEY CARD ................................................................................................................163
Program 89-CN-IP : DELETE KEY CARD ...............................................................................................................164
Program 91-TM : ACP TIME LOCK – Assign Time ................................................................................................165
Page 12
Program 92-CN : ACP TIME LOCK – Assign Card................................................................................................ 166
Program 93 : MINI CALL ACCOUNTING AOC ADDITIONAL NUMBER CHARGING........................................... 167
Program 94-tk-IP : Lunchtime Ringing And Ringing Line Preference Assignment .......................................... 169
Program 95-tk-IP : Trunk Specifications – 3 .........................................................................................................170
01. Detect Fax signal ..............................................................................................................................................170
02. Reserved........................................................................................................................................................... 171
03. Reserved........................................................................................................................................................... 171
04. DISA & ECF Lunch Time Enable ......................................................................................................................171
05. Reserved........................................................................................................................................................... 171
06. DUET (Faxibility) Setting................................................................................................................................... 171
07. Reserved........................................................................................................................................................... 171
08. Reserved........................................................................................................................................................... 171
Programming Cross Reference............................................................................................................................... 172
Incoming Calls......................................................................................................................................................... 172
Ringing Assignment............................................................................................................................................. 172
Outgoing Calls......................................................................................................................................................... 172
Dial ‘9' .................................................................................................................................................................. 172
PABX Outgoing Code..........................................................................................................................................172
Trunk Specifications ............................................................................................................................................172
Speed Dial ...........................................................................................................................................................173
Auto-Redial..........................................................................................................................................................173
Intercom Calls .........................................................................................................................................................173
Intercom Call Signalling....................................................................................................................................... 173
Step Call ..............................................................................................................................................................173
Dial Tone Pattern................................................................................................................................................. 173
Single Digit Intercom ..........................................................................................................................................173
Direct Station Select ............................................................................................................................................173
Dial 0 (Call Operator).......................................................................................................................................... 173
Intercom Dialling Restriction................................................................................................................................ 173
Busy/During Conversation.......................................................................................................................................174
Hold and Hold Recall...........................................................................................................................................174
Busy Remind / Camp-On..................................................................................................................................... 174
Call Split...............................................................................................................................................................174
Transfer ...............................................................................................................................................................174
Message Waiting Level ....................................................................................................................................... 174
Override...............................................................................................................................................................174
DISA........................................................................................................................................................................ 174
Night Service........................................................................................................................................................... 175
Group Assignments................................................................................................................................................. 175
Console Assignment............................................................................................................................................ 175
Flexible Key Group Assignments ........................................................................................................................175
Dial ‘9/0' Trunk Groups ........................................................................................................................................ 175
Dial ‘87' Trunk Groups ......................................................................................................................................... 175
Group Assignment for stations (Page Zone, Pick up, Single digit)...................................................................... 175
Call Control..............................................................................................................................................................175
Toll Restriction.....................................................................................................................................................175
Forced Account Codes ........................................................................................................................................176
Call Limit..............................................................................................................................................................176
Passwords ...........................................................................................................................................................176
Station Lock/Unlock.............................................................................................................................................176
Busy out a trunk................................................................................................................................................... 176
LYNX Plus Programming Manual Rev 2.1c Page
13
Intercom Dialling restrictions ................................................................................................................................176
System Clock...........................................................................................................................................................176
Date and Time Setup ...........................................................................................................................................176
System Alarm.......................................................................................................................................................176
Wake Up calls......................................................................................................................................................176
Station Numbering ...................................................................................................................................................176
Single Line Telephone .............................................................................................................................................177
Miscellaneous ..........................................................................................................................................................177
Monitor .................................................................................................................................................................177
Paging ..................................................................................................................................................................177
Call Forward No Answer Transfer Time...............................................................................................................177
Hot Line................................................................................................................................................................177
Optional Services.....................................................................................................................................................177
Door phone & Door switch ...................................................................................................................................177
Voice Mail Integration...........................................................................................................................................177
ACD-1 operation ......................................................................................................................................................178
Clear down of unanswered calls. .........................................................................................................................178
Auto Attendant and DISA operation.........................................................................................................................179
Enabling Auto Attendant/DISA Answer of Incoming Calls .......................................................................................179
DISA Answer Delay Time.....................................................................................................................................179
Clear down of unanswered calls. .........................................................................................................................180
Recording the DISA Messages................................................................................................................................180
Programming Single Digit DISA ...........................................................................................................................182
Installing ACP’s........................................................................................................................................................182
About security ......................................................................................................................................................182
ACP Applications .................................................................................................................................................183
How to set up as a door phone. ...........................................................................................................................184
How to unlock the door from the ACP using Forced Account Codes ..................................................................184
Setting Up DUET Ring Detect .................................................................................................................................184
Page 14
General Description - Introduction
The General Description section contains an easy to understand overview of the TransTel® Lynx Hybrid Telephone System. It is the intent of this document to provide both technical and non-technical readers with information pertaining to the system building blocks, capabilities, key highlights, electrical, physical and environmental characteristics of the TransTel Lynx Hybrid Telephone System.
FCC Rules and Regulation
In compliance with the requirements of Part 68 of the Federal Communications Commission Rules and Regulations for connection of terminal system equipment to the telephone network and for your convenience, the following information is presented.
FCC Registration Number
The TransTel G1-KT/Lynx is registered with the FCC in a dual registration capacity enabling the system to operate as a key system only or as a hybrid system. The FCC Registration Numbers are 3A7TAI-35152-KF-E for key systems registration and 3A7TAI-36015-MF-E for hybrid operation.
Ringer Equivalence Number 0.3B.
Notification of the Telephone Company
Customers connecting terminal equipment to the telephone network shall, upon request of the Telephone Company, inform the Telephone Company of the particular line(s) to which such connection is made, the FCC registration number and ringer equivalence number (REN) of the registered terminal equipment.
The REN is useful to determine the quantity of devices you may connect to your telephone line and still have all of those devices ring when your telephone number is called. In most, but not all areas, the sum of the REN's of all devices connected to one line should not exceed five (5.0). To be certain of the number of devices you may connect to your line, as determined by the REN, you should contact your local telephone company to determine the maximum REN for your calling area.
This equipment is capable of providing users access to Interstate providers of operator services through the use of access codes. Modification of this equipment by call aggregators to block access dialling codes is a violation of the Telephone Operator Consumers Act of 1990.
Direct Connection to a Party-Line or Coin Operated Telephone Line is Prohibited.
Incidence of Harm to the Telephone Lines
Should terminal equipment cause harm to the Telephone Network, the Telephone Company shall, where practical, notify the customer that service may be temporarily discontinued. However, where prior notice is not practical, the Telephone Company may temporarily discontinue service, if such action is reasonable in the circumstances. In case of such un-notified temporary discontinuance of service, the Telephone Company shall:
(a) Promptly notify the customer of such temporary discontinuance of service. (b) Afford the customer the opportunity to correct the situation which gave rise to the temporary
discontinuance.
(c) Inform the customer of the right to bring a complaint to the FCC pursuant to the procedures set
out in Subpart E of Part 68 of FCC Telephone Equipment Rules.
LYNX Plus Programming Manual Rev 2.1c Page
15
Compatibility of the Telephone Network and Terminal Equipment.
(a) Availability of telephone interface information.
Technical information concerning interface parameters and specifications not specified in FCC Rules, including the number of Ringers which may be connected to a particular line, which is needed to permit Terminal Equipment to operate in a manner compatible with Telephone Company communications facilities, shall be provided by the Telephone Company upon customer's request.
(b) Changes in Telephone Company Communications Facilities, Equipment, Operations and
Procedures. The Telephone Company may make changes in its communications facilities, equipment, operations or procedures where such action is reasonably required in the operation of its business and is not inconsistent with the rules and regulations in FCC Part 68 of the FCC Rules and Regulations. If such changes can be reasonably expected to render any customer Terminal Equipment incompatible with Telephone Company Communications Facilities, or require modification or alteration of such Terminal Equipment, or otherwise materially affect its use or performance, the customer shall be given adequate notice in writing to allow the customer an opportunity to maintain uninterrupted service.
Radio Frequency Interference
This equipment generates and uses radio frequency energy and if not installed and used properly and in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type-tested and found to comply with the limits for a Class A computing device in accordance with the specification in Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, this is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Re-orient the receiving antenna. Relocate the equipment with respect to the receiver.
Move the equipment away from the receiver. Plug the equipment into a different outlet so that equipment and receiver are on different branch circuits.
CTR 21 (98/482/EC) Declaration Network Compatibility
CTR 21 (98/482/EC) Declaration Network Compatibility,‘The equipment has been approved in accordance with Council Decision 98/482/EC for pan-European single terminal connection to the public switched telephone network (PSTN). However, due to differences between the individual PSTN networks provided in different countries, the approval does not, of itself, give an unconditional assurance of successful operation on every PSTN network termination point. In the event of problem, you should contact your equipment supplier in the first instance.’
Page 16
Description
The Lynx is a Hybrid Telephone System employing a microprocessor stored program and digitally controlled solid state Time-division switching. The Lynx system is specifically designed for small business as well as residential applications. At the forefront of the system design is a universal concept to adapting and connecting with a variety of communications devices. Productive TransTel Digital Key Telephones offer thoughtfully designed productive feature access to keep you connected with one another and customers. TransTel Communications, Inc. technology leads the industry in providing for compatibility with devices such as fax machines, answering machines, cordless phones, computer modems and other office/home equipment.
Key highlights of the Lynx include:
Economy and Efficiency
The base system is equipped to support three (3) CO lines four (4) digital stations and four (4) analog stations.. The system may be expanded to a maximum of five (5) CO lines / four (4) digital stations and eight (8) analog stations, digit station ports may be selected to allow practically any combination ranging from all TransTel DK Digital Sets to 4 Digital sets plus 8 industry standard Single Line Telephone sets, with multiple combinations of the two types. In addition to being cost effective at the initial phase and for expanding to its maximum capacity, the Lynx also is economical to operate as it consumes about the same amount of electricity as a 60 watt light bulb at full configuration. A maximum of 5 CO lines and 12 Extensions can be accommodated. This allows a wide variety of applications for the system to work effectively.
Easy Installation
“Factory Ready” - All Lynx systems are "ready to go" right out of the box. A well thought out default database is factory installed on each system which meets the needs for most installations. This alleviates hours of on site time, minimizing installation costs for both dealer and customer.
“Small & Compact” - The Key Service Unit's small size takes little space for installation.
Easy Maintenance
Solid-state design minimizes trouble and eliminates periodic maintenance.
Easy Expansion. Various Interface Cards for simple, modular expansion.
Versatile programming and options for ease of selection.
Database Flash Memory Back Up - Customer data is backed up when the power is turned off and there is no
battery to replace.
Battery Back Up (System Operation) - Lynx can be equipped with an optional battery back up which keeps the
system operational for up to 1 hour in the case of a commercial power failure.
Customer Care Programming - Customers and service personnel can easily communicate and perform
programming right over the telephone. TransTel telephone systems allow programming and voice conversations to be performed at the same time.
Advanced software upgrades – Through the RS232 connection, system software can be upgraded easily without
replacing any firmware.
Flexibility of System Applications
Unlike other conventional systems in the Lynx size range, the installer will find an unprecedented range of customer database programmability. In "system parameters" there are extensive options for various timing settings related to features. An array of parameters are programmable for signalling options on outside lines and internal single line telephone sets. The installer may Enable/Disable many system wide features. And in class of service, there are over 20 options for each station providing maximum flexibility for nearly any application.
LYNX Plus Programming Manual Rev 2.1c Page
17
Varied Extension Alternatives
You can connect proprietary TransTel DK series Keyphone, Door Phones and conventional industry standard single line sets – Modem, Answering Machine, Cordless phone, etc. directly to the KSU. This feature provides you with the choice to select different extension equipment to suit individual applications.
Page 18
Liquid Crystal Display
The DK Series Telephone Model DK6 and DK7 phones are equipped with a large, easy to read LCD display. The LCD is 32 characters total, comprised of 2 rows by 16 characters each. This LCD provides an invaluable tool for simplifying the use of the telephone by identifying the calling extension by name, outside lines by name and self prompting displays for feature access. Station feature usage is made simple with the help of the LCD display. Continuous prompting information is displayed during calls so that users know what to do and when to do it.
32/64-character LCD Display shows:
Time Last number dialled
Dialed telephone number The status of operation/function
Voice Mail Messages Absent messages
CO Line Names Speed Dial Directory
Last Number Redial Calling Party Number and Name
Speed dial number Input data during system data entry
TransTel Telephone Model DK7
DK-7
DK6-36 DK6-18
LYNX Plus Programming Manual Rev 2.1c Page
19
Specifications
MAXIMUM LOOP RESISTANCE/IMPEDANCE Key Telephone Less than 40 ohms 26 AWG / 200 m Single Line telephone Less than 800 ohms 26 AWG / 800 m DoorPhone Less than 40 ohms
INTERNAL RELAY CONTACTS Type SPST Rating 1 AMP, 24VDC Function Door Switch, Music on Hold, etc CABLE REQUIREMENTS CO/PABX Line Twisted 1 Pair (2 wires) ISDN BRI Twisted 2 Pair (4 wires) DK1 Digital Key Telephone Twisted 1 Pair (2 wires) Doorphone Twisted 1 Pair (2 wires) Door Switch Twisted 1 Pair (2 wires) External Sensor Twisted 1 Pair (2 wires) Single Line Telephone Twisted 1 Pair (2 wires)
Mechanical Specifications (Key Service Unit)
CABINET DIMENSIONS 425mm W 85mm D 315mm H
16.7” 3.3" 12.4" WEIGHT 3.9 Kg (Configuration: 4 x 8)
8.59 lbs
Mechanical Specifications (Battery Back Up Housing)
CABINET DIMENSIONS 36 cm W 13 cm D 44 cm H WEIGHT With Batteries -16 lbs Without Batteries- 4 lbs.
Mounting Screws 12.25” centre to centre
Environmental Specifications
OPERATING CONDITIONS STORAGE
Temperature 0º to 30º C -40º to 66º C (32º to 86º F) (-40º to 150º F) Humidity 10 to 95% relative 10 to 95% relative Non-condensing non-condensing
CONDITIONS
Page 20
Features
System Features
Account Code Capability Attendant Console Assignment Attendant Overflow Automatic Line Access Automatic Line Search Automatic Ringdown Automatic Wake-up Battery Charger Behind PABX Operation Centrex Operation Class Of Service CO Line Groups CO Line Hunting CO Line Name Programming CO Line Ring Types Linear Common Audible Circular Hunt Console Assignment Day/Night Service Manual/Automatic Switch Dial 9 Group Direct In Line Dial By Name Dial Mode Selection(DP/DTMF) Dial Pulse to DTMF Conversion Distinctive Ringing DTMF Signalling Dual Port Capability End to End Signalling Easy Installation and Operation Flash (Programmable) Flash Memory Backup Memory Flexible Expansion
Host PABX Access Hot line Line Group Assignment Loud Bell Assignment Multiple Attendant Consoles Multiple Trunk Groups Night Transfer On Call Programming Paging
Internal Zone
Meet Me Password Assignment DISA System programming Toll Override Pause Pick Up Groups Power Fail Transfer Security Code Single Digit Dialling Station Group Assignment Station Hunting Station Lock System Speed Dial and Personal Speed Dial System Date & Time Setting System Time-Reminder Service Telephone Directory Toll Control Day / Night Tone to pulse dialling Trunk Queuing Trunk to trunk connections Uniform Call Distribution Voice Mail Compatibility
Flexible Ringing Assignment Flexible Key Group Assignment Flexible Number Plan 2,3 or 4 Digit Flexible Time Format 12/24 Hour Forced Account Code Assignment Intercom Intercom Single Digit Assignment Intercom Ring / Voice Select Intercom Dialling Restriction
LYNX Plus Programming Manual Rev 2.1c Page
21
Station Features
Advisory Messages Access to System Programming Account Code Capability Auto Hold Auto Hold Recall Automatic Call Back Automatic Answer-Intercom Automatic Line Access Automatic Redial Automatic Volume Increase Brokers Call Call Duration Timer (LCD Phones) Call Waiting Call Forwarding All Calls Busy No Answer Busy / No Answer External Call Pickup Call Split Call Transfer Calling Name Display (LCD Phones) Calling Number Display (LCD Phones) Camp On
Chain Dialling Conference Dial By Name (LCD Phones) Dial Access to Attendant Direct Station Selection DoorPhone Access Do Not Disturb (DND) Dual Color LED Duration Time Display (LCD Phones) Executive Override (Barge-In) External Call Forwarding Flash (Open Loop Timed Flash) Hands-free Answer Back Hearing Aid Compatibility Headset Compatibility Hold (Exclusive / System) Hold Recall I Hold Indication I Use Indication Intercom Intercom ring / voice interchange Intercom Step Call Intercom Voice Announce Last Number Redial Message Waiting Multi-Language Display On Hook Dialling
Page 22
Parts & Peripherals
System Modules
Model Description
G1-KT-308P KSU with 3 CO lines, 4 Digital ports and 4 Slt ports with CLIP (Caller ID) function
RS232/Relay/Sensor
G1K-TLU Trunk/Single Line Card : 2 CO lines and 4 SLT ports / with CLIP (Caller ID) function
Type of Phones
Model Description
DK7-21 Multifunction Key Telephone. Includes 32 character LCD display, speakerphone,
Handsfree, headset jack, 10 dual color keys and 14 function keys for feature access, DSS, CO Lines and speed dial.
DK6-36 Multifunction Key Telephone with 2 line LCD display, speakerphone, Handsfree,
headset jack, 36 dual color keys and 7 function keys for feature access, DSS, CO Lines and speed dial.
DK6-12 Multifunction Key Telephone with 2 line LCD display, speakerphone, Handsfree,
headset jack, 12 dual color keys and 7 function keys for feature access, DSS, CO
Lines and speed dial. DPU1 Digital Door phone – weather resistant ACP/RF Access Control Phone with RF Proximity Card function PX-Card RF Proximity Card for ACP/RF WMU-x Wall Mount Kits for DK Series Telephones
Peripheral Devices
Model Description
BBOX0 Battery Box without Batteries BBOX1 Battery Box with Batteries
Optional Interface Cards
Model Description
G1K-NFC­128M
2 Channel Voice mail card
LYNX Plus Programming Manual Rev 2.1c Page
23
Page 24
System Installation - Introduction
This section provides directions for installing the system and optional equipment. The installation must be performed by qualified service personnel.
Main components of the system are:
Key Service Unit, which includes:
Power Supply Unit (G1K-PWU)
Main Board Unit (G1K-MBU2 / Common Control,
4 digital port circuits and 4 SLT ports) On board messaging and Auto Attendant.
NOTE: Please follow the directions step by step. The Lynx system should be installed in strict accordance with this manual.
Optional Expansion Cards:
TLU Card (2 CO + 4 single line port circuits)
LYNX Plus Programming Manual Rev 2.1c Page
25
Site Requirements
Location
Choosing the Right Environment
System should be installed in a clean, dry, secure location. This location must have adequate ventilation, and a temperature from 0 to 30 (32 to 86), with 10% to 95% non-condensing relative humidity. DO NOT install the equipment near sources of static electricity, excessive vibration, or water. Avoid direct sunlight.
Installation Checklist
INSTALLATION REQUIREMENTS VERIFICATION
MOUNTING SURFACE Flat surface with adequate space for main cabinet,
power supply, wiring and optional Battery Backup
cabinet. AC LINE AC line should be dedicated exclusively to the system. POWER OUTLET Power Outlet must be a 3-wire grounded outlet plug.
The socket outlet shall be installed near the system and
be easily accessible.
Input power Line capacity requirements - 10 amperes.
CAUTION DOUBLE POLE/NEUTRAL FUSING ON
EUROPEAN PLUGS
SURGE PROTECTION A Surge Protector is recommended on the dedicated AC
line. VENTILATION AND TEMPERATURE Humidity: 10% to 95% relative non-condensing
Temperature:32 to 113 (0 to 45 ). EARTH GROUND A proper ground connection. (14 AWG) SERVICEABILITY Lighting conditions and working space adequate for
future service.
Equipment Requirements
Unpack, Check and Verify Equipment - Unpack the telephone equipment boxes and verify the contents in accordance with the packing list provided. If any discrepancies are noticed, please contact TransTel Communications, Inc. or Authorized Dealers.
Damaged Boxes - If you notice any damage to the packages, please notify both the shipper and TransTel communications, Inc. or Authorized Dealers at once.
List of parts included in basic KSU box:
KSU Main Cabinet
Mounting Template
Mounting Screws
Station Quick Connectors
Spare Fuses
Cable Cover
Installation
Caution
1. This system should be installed by qualified service personnel.
2. Do not install the Power Supply unless you have read the following instructions and
completed all the installation and wiring.
Page
26
3. STATIC SENSITIVE DEVICES! Please handle with care.
Installing expansion and optional cards
In this step you will be installing printed circuit cards on to header pins of the main board in the basic cabinet. Take your time and extra care to assure the printed circuit cards are properly aligned. After installing each option and expansion card, perform a visual inspection to assure the printed circuit card is installed properly.
1. Position the cabinet on a flat surface like a table or countertop. Avoid doing this on carpet.
2. Remove the 4 screws located at the corners of the cabinet and lift the front cover off.
3. Locate the expansion and option cards and unpack them at this time.
Card Introduction
G1K-PWU-Power Supply Interface Card
1. CN1: AC 24VAC Input
2. CN50: Battery Connection +24V to +27V DC
3. CN3: Cable connection from G1K-PWU to G1K-MBU CN1
4. LED1: G1K-PWU DC +24V indication
5. F1/F2: 4A/250V
LYNX Plus Programming Manual Rev 2.1c Page
27
G1K-MBU2 Main Board Unit
1. CN1: Power connection to G1K-PWU CN3
2. LED2: DSP operation indication when slow flashing is normal
3. CN11: To G1K-NFC 128 CN1
4. EC1: Gold capacitor which provided for Real Time Clock
5. CN2: To G1K-TLU CN1
6. CN6: CO 1~CO 3 input from Central Office
7. CN8: External Music
8. CN7: Relay/Sensor/Ex-Page
9. CN10: RS232 connection
10. JP1: Clear Flash Memory / Normal Operation
11. LED1: System operation indication when slow flashing is normal
12. CN12: Connections for Digital Ports 11~14 (ST1~ST4) and SLT Ports 15~18 (ST5~ST8)
Page
28
G1K-TLU 2 Port CO Line and 4 Port SLT
CN1: To G1K MBU CN2 CN3: CO 4 and CO 5 input from Central Office CN5: Connections for SLT port 19, 20 (ST9~ST10) CN4: Connections for SLT port 21, 22 (ST11~ST12)
G1K-NFC 128
CF Card G1K-NFC (32kbps) G1K-NFC (16kbps)
128M
Total 1 Unit Duration Duration Total 1 Unit Duration Duration
Unit Duration (mins) (hours) Unit Duration (mins) (hours)
(secs) (secs)
For a description of the VMU and Auto Attendant setup and configuration including how to record messages see the section at the end of the Installation Manual
LYNX Plus Programming Manual Rev 2.1c Page
29
Install G1K-TLU 2 CO line 4 port SLT
Power off the system before installing card Install 2 spacers to the MBU by removing screws from the MBU and replacing with spacers Align CN1 of the G1K-TLU card with CN2 of the G1K-MBU. Align the hole on right side of G1K-SLU with the standoff.
Page
30
Loading...
+ 155 hidden pages