INTRODUCTION INTRODUCTION
Safety Information
The signs below might be in the user manual, labeling or other component.
They are the requirement of standard and using.
Symbol for “THE OPERATION
GUIDE MUST BE READ”
Symbol for “MANUFACTURER”
Symbol for “SERIAL NUMBER”
Symbol for “TYPE BF APPLIED
PARTS”
Symbol for “DIRECT CURRENT”
Symbol for “ENVIRONMENT
PROTECTION - Electrical waste
products should not be disposed of
with household waste. Please recycle
where facilities exist. Check with your
local authority or retailer for recycling
advice”
Symbol for “MANUFACTURE
DATE”
Thank you for selecting TRANSTEK arm type blood pressure Monitor
(TMB-1491-BT). The monitor features blood pressure measurement, pulse
rate measurement and the result storage. The design provides you with
two years of reliable service.
Readings taken by the TMB-1491-BT are equivalent to those obtained by
a trained observer using the cuff and stethoscope auscultation method.
This manual contains important safety and care information, and
provides step by step instructions for using the product.
Read the manual thoroughly before using the product.
Features: Maximum 60 records
General Description
For indoor use only
F1
7$9ĭ&&& Symbol for “Class II Equipment”
3rd technonoly: Measuring during inflation
(The updated technology in the world)
60mm×40.5 mm Digital LCD display
The Bluetooth Combination Mark
Symbol for “Including RF
transmitter”
This device is intended for adult use only.
This device is intended for no-invasive measuring and monitoring of arterial blood pressure. It is not
intended for use on extremities other than the arm or for functions other than obtaining a blood pressure
measurement.
Do not confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood pressure.Do
not begin or end medical treatment without asking a physician for treatment advice.
If you are taking medication,consult your physician to determine the most appropriate time to measure your
blood pressure. Never change a prescribed medication without consulting your Physician.
When the device was used to measure patients who have common arrhythmias such as atrial or
ventricular premature beats or atrial fibrillation, the best result may occur with deviation. Please consult
your physician about the result.
If the cuff pressure exceeds 40 kPa (300 mmHg), the unit will automatically deflate. Should the cuff not
deflate when pressures exceeds 40 kPa (300 mmHg), detach the cuff from the arm and press the
START/STOP button to stop inflation.
The equipment is not AP/APG equipment and not suitable for use in the presence of a flammable
anesthetic mixture with air of with oxygen or nitrous oxide.
The operator shall not touch output of batteries/AC adaptor and the patient simultaneously.
To avoid measurement errors, please avoid the condition of strong electromagnetic field radiated
interference signal or electrical fast transient/burst signal.
The user must check that the equipment functions safely and see that it is in proper working
condition before being used.
This device is contraindicated for any female who may be suspected of, or is pregnant. Besides providing
inaccurate readings, the effects of this device on the fetus are unknown.
Manufacturer will make available on request circuit diagrams, component parts list etc.
This unit is not suitable for continuous monitoring during medical emergencies or operations. Otherwise,
the patient’s arm and fingers will become anaesthetic, swollen and even purple due to a lack of blood.
Please use the device under the environment which was provided in the user manual. Otherwise, the
performance and lifetime of the device will be impacted and reduced.
During use, the patient will be in contact with the cuff. The materials of the cuff have been tested and
found to comply with requirements of ISO 10993-5:2009 and ISO 10993-10:2010. It will not cause any
potential sensization or irritation reaction.
The device has been evaluated clinically using manual cuff/stethoscope auscultation as the reference.
Blood pressure measurements determined with this device are equivalent to those obtained by a trained
observer using the cuff/stethoscope auscultatory method, within the limits prescribed by the American
National Standard, Manual, electronic, or automated sphygmomanometers.”
The patient is an intended operator. The patient can measure under normal circumstances and maintain
the device and its accessories according to the user manual.
The blood pressure monitor, and the cuff are suitable for use within the patient environment. If you are
allergic to dacron or plastic, please don’t use this device.
Please keep the unit out of reach of infants, children or pets, since inhalation or swallowing of small parts is
dangerous or even fata.
If Luer lock connectors are used in the construction of tubing, there is a possibility that they might be
inadvertently connected to intravascular fluid systems, allowing air to be pumped into a blood vessel.
The device is not suitable for public use.
The device is not intended for PATIENT transport outside a healthcare facility.
This device cannot be used with HF surgical equipment at the same time.
Be careful to strangulation due to cables and hoses, particularly due to excessive length.
CAUTION
Indications for Use
The Transtek Blood Pressure Monitor is digital monitors intended for use in
measuring blood pressure and heartbeat rate with arm circumference ranging
IURPFPWRFPDERXWôÝòÝRUFPWRFPDERXWôÝòÝ
It is intended for adult indoor use only.
SN