23,Jin'an Road, Minzhong, Zhongshan, 528441, Guangdong, China
TEL:86-760-88282982 www.transtek.cn
Thank you very much for selecting the Transtek Body Fat Analyzer
LS208-B8.
Please do read the user manual carefully and thoroughly so as to ensure
the safe usage of this product, and keep the manual well for further
reference in case you have problems.
The warning signs and symbols are essential to ensure your correct and safe use of
this product and protect you and others from injury. Please kindly find the meanings of the
warning signs and symbols, which you may encounter in the label and user manual, as
follows:
Symbol for “THE OPERATION
GUIDE MUST BE READ”
The Bluetooth Combination Mark
Symbol for “TYPE BF APPLIED
PARTS”
Symbol for “SERIAL NUMBER”
Symbol for “MANUFACTURE
DATE”
Symbol for “MANUFACTURER”
Symbol for “DIRECT CURRENT”
Symbol for “ENVIRONMENT
PROTECTION – Waste electrical
products should not be disposed of with
household waste. Please recycle where
facilities exist. Check with your local
authority or retailer for recycling advice”
INDICATIONS FOR USE
The Transtek Body Fat Analyzer measures weight and estimate BMI and calories, and uses
bio-electrical impedance analysis (BIA) technology to estimate body fat, total body water
percentage, bone mass, and muscle mass in generally healthy children 10-17 years old and
healthy adults.
It is intended for use in the domestic setting only.
CONTRAINDICATIONS
1. This device is contraindicated for any female subject who may be suspected of, or is pregnant.
Besides provided inaccurate readings, the affects of this device on the fetus are unknown.
2. This device is contraindicated for any person who is connected to a wearable or implantable
electronic device or instrument such as a pacemaker or defibrillator.
Your Scale and Its Environment
To ensure your safety as well as the service life of your scale, please avoid using
the scale under the following circumstances:
Slippery floor such as tile floor
CAUTION
The Body Fat Analyzer LS208-B8 offers you a seamless way to manage your health. Please
be aware that this device is designed for adults’ self-measuring and self-monitoring body fat
level. Any information provided by this device is in no way meant to treat, cure or prevent any
disease or illness from happening. This device should not be used by anyone who is acutely or
chronically ill, suffering from a disease or taking medications that affect your water levels. The
accuracy of readings for these patients has not been verified. Specific medical advice should be
obtained from a physician.
Before diet and exercise, you must first find a professional medical guide.
The body fat analyzer is equipped with data transmission function. It may emit electromagnetic
energy so as to perform its intended function. Nearby portable and mobile RF communications
equipment can affect the performance of the device .
Portable and mobile RF communications equipment can affect the measuring accuracy of the
body fat analyzer.
Kindly note that the use of accessories, transducers or cables other than those specified, with
the exception of transducers and cables sold by the manufacturer as replacement parts for
internal components, may result in increased EMISSIONS or decreased IMMUNITY of the
device.
Be aware that misuse of electrical equipments can cause electric shock, burns, fire and other
hazards.
Please do not use the device in flammable gas environment.
Warning that the body fat analyzer should not be used adjacent to or stacked with other
equipment.
Manufacturer will make available on request circuit diagrams, component parts list,etc.
WARNING:No modifications of this equipment is allowed.
During using the analyzer, the patient will contact with the surface and the electrode of the
Analyzer. The surface and the electrode of the analyzer is type BF Applied part.
The device doesn’t need to be calibrated in five years lifetime.
Do not touch the output of batteries when using the analyzer.
The patient is an intended operator. The patient can perform all the operations in the manual,
such as measurement, data transmitting, changing batteries.
Jumping onto the platform immediately after bath or with wet feet
Near a cell phone or microwave oven
Avoid storage in the following locations:
Where there is water
Where the device may be exposed to extreme temperatures, humidity, moisture, direct
sunlight, dust, or salt air
Where there is risk of shock or drop
Where you store chemicals or full of corrosive gases
Where in reach of the infants or children
Efficient Use of Your Scale
To ensure the accuracy of measurement, please follow below instructions when
you start measurement.
Place the scale on a flat, hard surface. Soft surface such as carpet will affect the
performance of the scale.
Step onto the platform with bare feet. Stand still and keep full contact with the scale until
the measurement is complete.
Start measurement at least two hours after Getting up or Dinning.
Avoid measurement immediately after strenuous exercise, sauna or bath, drinking, and
dinning.
Always start measurement in the same time slot and on the same scale located on the
same flat, hard surface.
23
OverviewOverview
Device Components
Up Key
LED Display
Down Key
Set Key
UNIT and activation Button
Battery Compartment
Sensor
LED Display
Body Fat Analysis Result
Total Body Water Analysis Result
Muscle Mass Analysis Result
Bone Mass Analysis Result
Calorie Analysis Result
Body Mass Index
Male
Male Athlete
Female
Female Athlete
Kilogram
Stone
List
1. Body Fat Analyzer LS208-B8
2. Four AAA-size Batteries (1.5V per each)
3. User Manual
Age
Foot
Centimeter
Body Fat Level: Underfat
Body Fat Level: Healthy
Body Fat Level: Overfat
Body Fat Level: Obese
Pound
Percentage
User ID (Rangr form P1 to P8)
Successful Bluetooth Connection
Data transmitting / pending to
transmit to wireless wellness system
Low Battery
45
Initial Start-UpInitial Start-Up
General Instructions
Transtek Body Fat Analyzer LS208-B8 applies BIA (Bio-impedance Analysis) technology.
A small amount of weak current flows through the human body so as to detect the
bio-impedance and estimate calorie, BMI, body fat, body water, muscle mass and bone
mass. The electrical current is small and may not be felt.
This BIA technology is cheap, safe, non-invasive, toxic-free and harmless. It also
possesses the characteristics of simple operation and abundant information.
The current mentioned above is less than 0.5mA. However, please be aware that anyone
with an wearable or implantable medical electronic instrument, such as a pacemaker, must
avoid using this device.
The intended use of this device is for healthy children 10-17 years old and healthy adults.
Insert the Batteries
Open the battery door in the back of the scale.
Insert the batteries (4 x 1.5V AAA) into the battery
compartment according to the polarity indications
marked inside the compartment.
* The digits “ 8888 ” will be shown on the LED.
Close the battery door and wait until the digits “ ”
are shown on the LED.
Install APP and Pair-Up
With the advanced Bluetooth 4.0 technology applied, the mobile or portable equipments,
which are equipped with Bluetooth function in line with BLE Technical Specifications as
well as BLP Protocol established by global organization Bluetooth SIG, are capable to
receive your personal health data.
Just simply install the specially-designed app and pair up your scale with your mobile or
portable equipments. Then you may enjoy the comprehensive health solution provided by
Transtek.
Note: It is only available for the device which supports Bluetooth 4.0 technology.
Turn on Bluetooth and the App. Make sure both are ON when pair-up is proceeding.
Press and hold “UNIT” button in the back of the scale to start pair-up.
Symbol and symbol will be shown on the LED alternatively, indicating pair-up
is proceeding.
If SUCCEED, symbol “PASS” will be shown on the LED.
CAUTION
When the symbol and “ Lo” appear, the device will power off. Then you shall replace with a new set
of batteries. Please replace all four batteries at the same time. Do NOT mix the old batteries with the new
one.
Worn batteries are hazardous waste. Do NOT dispose of them together with the household garbage.
Please refer to the local ordinances and recycling instructions regarding disposal of the worn batteries
and scrapped device.
If you do not intend to use this unit for a prolonged period of time, it is advisable to remove the batteries
before storing.
6
If FAIL, symbol “FAIL” will be shown on the LED.
7
Loading...
+ 10 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.