TRANSTEK TMB-1583-BT User Manual

MEM
SET
START STOP
version:1.0
User Manual
Blood Pressure Monitor
TMB-1583-BT
Thank you very much for selecting TRANSTEK Blood Pressure Monitor TMB-1583-BT.
Please do read the user manual carefully and thoroughtly so as to ensure the safe usage of this product, and keep the manual well for further reference in case you have problems.
Guangdong Transtek Medical Electronics Co., Ltd.
Zone A, No.105 ,Dongli Road, Torch Development District, Zhongshan,528437,Guangdong,China
Table of Contents
INTRODUCTION...................................................................................................................2
General Description Indications for Use Safety Information LCD Display Signal Monitor Components
BEFORE YOU START...........................................................................................................8
The Choice of Power Supply Installing and Replacing the Batteries Measurement Principle
Setting Date, Time, Measurement Unit and Clock Mode
Select the User Pair-up the Blood Pressure Monitor with Your Device
MEASUREMENT...................................................................................................................14
Tie the Cuff Start the Measurement
DATA MANAGEMENT...........................................................................................................17
Recall the Records Delete the Records
SPECIAL FUNCTION............................................................................................................19
About the Clock Mode About the Lock Button
INFORMATION FOR USER..................................................................................................20
Tips for measurement Maintenances
ABOUT BLOOD PRESSURE................................................................................................22
What are systolic pressure and diastolic pressure? What is the standard blood pressure classification? Why does my blood pressure fluctuate throughout the day? Why do I get a different blood pressure at home compared to the hospital? Is the result the same if measuring on the right arm?
TROUBLESHOOTING..........................................................................................................24
SPECIFICATIONS................................................................................................................25
AUTHORIZED COMPONENT .............................................................................................26
CONTACT INFORMATION...................................................................................................26
COMPLIED STANDARDS LIST............................................................................................27
FCC STATEMENT.................................................................................................................28
EMC GUIDANCE..................................................................................................................29
CATALOGUE CATALOGUE
1
Safety Information
The signs below might be in the user manual, labeling or other component.
They are the requirement of standard and using.
Symbol for “THE OPERATION GUIDE MUST BE READ”
Symbol for “MANUFACTURER”
Symbol for “SERIAL NUMBER”
Symbol for “TYPE BF APPLIED PARTS”
Symbol for “DIRECT CURRENT”
Symbol for “ENVIRONMENT PROTECTION - Electrical waste products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice”
Symbol for “MANUFACTURE DATE”
Thank you for selecting TRANSTEK arm type blood pressure Monitor (TMB-1583-BT). The monitor features blood pressure measurement, pulse rate measurement and the result storage. The design provides you with two years of reliable service.
Readings taken by the TMB-1583-BT are equivalent to those obtained by a trained observer using the cuff and stethoscope auscultation method.
This manual contains important safety and care information, and provides step by step instructions for using the product.
Read the manual thoroughly before using the product.
Features:
Maximum 60 records
General Description
For indoor use only
F1
T1A/250V Φ3.6*10CCC
Symbol for “Class II Equipment”
3rd technonoly: Measuring during inflation (The updated technology in the world)
84mm×73 mm Digital LCD display
The Bluetooth Combination Mark
Symbol for “Including RF transmitter”
Indications for Use
The Transtek Blood Pressure Monitor is digital monitors intended for use in measuring blood pressure and heartbeat rate with arm circumference ranging
from 22 cm to 32 cm ( about 8¾˝-12½˝ ) or 22cm to 42cm(about 8¾˝-16½˝).
It is intended for adult indoor use only.
The device is not suitable for measuring the blood pressure of children. Ask your doctor before using it on older children. The device is not suitable for use on pregnant women, patients with implanted, electrocical devices, patients with pre-elcampsia, premature ventricular beats, atrial fibrillation, peripheral, arterial disease and patients undergoing intravascular therapy or arterio-venous shunt or people who received a mastectomy. Please consult your doctor prior to using the unit if you suffer from illnesses Do not take any therapeutic measures on the basis of a self measurement. Never alter the dose of a medicine prescribed by a doctor. Consult your doctor if you have any question about your blood pressure. Please keep the unit out of reach of infants, children or pets, since inhalation or swallowing of small parts is dangerous or even fatal.
CAUTION
Caution: These notes must be observed to prevent any damage to the device.
INTRODUCTION
INTRODUCTION
2
3
LCD display signal
SYMBOL DESCRIPTION
Systolic blood pressure High pressure result
Diastolic blood pressure Low pressure result
EXPLANATION
Pulse per minute Beats per minute, BPM
Memory
The displayed measurement values is from the memory.
mmHg
kPa
Measurement Unit of the blood pressure
Measurement Unit of the blood pressure
Low battery
Batteries are low and need to be replaced
Irregular heartbeat Detection
Grade
The grade of the blood pressure
Current Time
(1kPa=7.5mmHg)
(1mmHg=0.133kPa)
Irregular heartbeat
Average value
The average value of the latest three records
CAUTION
This device is intended only for adult use in homes. This device is intended for non-invasive measuring and monitoring of arterial blood pressure. It is not intended for use on extremities other than arm or for functions other than obtaining a blood pressure measurement. If you experience discomfort during a measurement, such as pain in the arm or other complaints, press the START/STOP button to release the air immediately from the cuff. Loosen the cuff and remove it from your arm. On the rare occasion of a fault causing the cuff to remain fully inflated during measurement, open the cuff immediately. Prolonged high pressure (cuff pressure >300mmHg or constant pressure >15mmHg for more than 3 minutes) applied to the arm may lead to an ecchymosis. Too frequent and consecutive measurements could cause disturbances in blood circulation and injuries. Do not wrap the cuff on the same arm which other monitoring ME EQUIPMENT is applied simultaneously, because this could cause temporary loss of function of those simultaneously-used monitoring ME EQUIPMENT. Don’t kink the connection tube during use, otherwise, the cuff pressure may continuously increase which can prevent blood flow and result in harmful injury to the PATIENT. The maximum temperature that the applied part can be achieved is 42.5 while the environmental temperature is 40.(only for wrist blood pressure monitor) The equipment is not AP/APG equipment and not suitable for use in the presence of a flammable anesthetic mixture with air of with oxygen or nitrous oxide. This unit is not suitable for continuous monitoring during medical emergencies or operations. This device cannot be used with HF surgical equipment at the same time. This device is not intended for patient transports outside a healthcare facility. To avoid measurement errors, please avoid the condition of strong electromagnetic field radiated interference signal or electrical fast transient/burst signal. The operator shall not touch output of batteries/adapter and the patient simultaneously. Manufacturer will make available on request circuit diagrams, component parts list etc. The materials of the cuff have been tested and found to comply with requirements of ISO 10993-5:2009 and ISO 10993-10:2010. It will not cause any potential sensization or irritation reaction.Never apply the cuff over hurt skin. Do not use the unit in case of existing polyester resp. synthetic allergies. Be careful to strangulation due to cables and hoses, particularly due to excessive length. Do not connect the air hose to other medical equipment, as this could cause air to be pumped into intravascular systems or high pressure, what could lead to dangerous injuries. Before use, make sure the device functions safely and is in proper working condition. Please use the device under the environment which was provided in the user manual. Otherwise, the performance and lifetime of the device will been impacted and reduced. Please use ACCESSORIES and detachable partes specified/ authorised by MANUFACTURE. Otherwise, it may cause damage to the unit or danger to the user/patients. Please dispose of ACCESSORIES, detachable parts, and the ME EQUIPMENT according to the local guidelines. Please do not attempt to repair the unit yourself in the event of malfunctions. Only have repairs carried out by authorized service centers. Please report to Manufacturer if any unexpected operation or events occur. The device doesn’t need to be calibrated in two years of reliable service. Please use the soft cloth to clean the whole unit. Don’t use any abrasive or volatile cleaners.
Year/Month/Day(M/D or D/M), Hour/Minute
INTRODUCTION
INTRODUCTION
4
5
MEM
SET
START STOP
Heartbeat
Heartbeat detection during the measurement
User 1
Start measurement,save and transmit the measuring results for User 1
User 2
Start measurement,save and transmit the measuring results for User 2
Bluetooth icon
The bluetooth icon blinks when the bluetooth is working
SYMBOL DESCRIPTION EXPLANATION
ErrorError
Hour The hour in the clock mode
Minute
Second
The minute in the clock mode
The second in the clock mode
MEM
SET
START STOP
Monitor Components
List
1.Blood Pressure Monitor (TMB-1583-BT)
4.User manual
2.Cuff (Type BF applied part) (22cm~32cm or 22cm~42cm)
Component list of pressure measuring system 1 Cuff 2 Air pipe 3 PCBA
4 Pump
5 Valve
5. AC Adaptor (KH0601000UW !)
3. 4×AAA alkaline batteries
BATTERY COMPARTMENT
MEM BUTTON
START/STOP BUTTON
SET BUTTON
CUFF
AIR HOSE
LCD DISPLAY
AIR CONNECTOR PLUG
(Please use TRANSTEK authorized cuff. The size of the actual cuff please refer to the label on the attached cuff.)
LOCK BUTTON
DC POWER SOCKET
INTRODUCTIONINTRODUCTION
7
6
SET
In order to get the best effect and protect your monitor,please use the right
battery and special power adaptor which complies with U.S. safety standard.
• .Open the battery cover.
• .Install the batteries by matching
the correct polarity, as shown.
.Replace the cover.
Installing and Replacing the Batteries
CAUTION
Remove batteries if the device is not likely to be used for some time.
The old batteries are harmful to the environment, do not dispose with other daily trash.
Remove the old batteries from the device and follow your local recycling guidelines.
CAUTION
Replace the batteries whenever the below happen
The shows
The display dims
The display does not light up
Do not dispose of batteries in fire. Batteries may explode or leak.
AC adaptor
The Choice of Power Supply
1.Battery powered mode:
6VDC 4×AAA alkaline batteries
2.AC adaptor powered mode:
6V 1A
(Please only use the recommended AC adaptor model).
Please unplug the adaptor to depart from
the using utility power.
Measurement Principle
It is important to set the clock before using your blood pressure monitor, so that a time stamp can be assigned to each record that is stored in the memory. (The setting range of the year :2014—2054 time format:12H/24H)
1.When the monitor is off, hold pressing “SET” button for 3 seconds to enter the mode for year setting.
2.Press the “MEM” button to change the [YEAR]. Each press will increase the numeral by one in a cycling manner.
This product uses the Oscillometric Measuring method to detect blood pressure. Before every measurement, the unit establishes a “zero pressure” equivalent to the air pressure. Then it starts inflating the arm cuff, meanwhile, the unit detects pressure oscillations generated by beat-to-beat pulsatile, which is used to determine the systolic and diastolic pressure, and also pulse rate. The device also compares the longest and the shortest time intervals of detected pulse waves to mean time interval then calculates standard deviation. The device will display a warning signal with the reading to indicate the detection of irregular heartbeat when the difference of the time intervals is over 25%.
Setting Date, Time, Measurement Unit and Clock Mode
BEFORE YOU START
BEFORE YOU START
9
8
8.After the clock mode is set,the LCD will display “done” and then turn off.
6.Repeat steps 2 and 3 to set the [UNIT].
7.Repeat steps 2 and 3 to set the clock mode.
3.When you get the right
year, press “SET” button to set down and turn to
next step to set the date format between “M/D” or “D/M”.
4.Repeat steps 2 and 3 to set the [DATE FORMAT], then set the [MONTH] and [DAY].
.Repeat steps 2 and 3 to set the [TIME FORMAT] between 12H or 24H, then set the [HOUR] and [MINUTE].
5
BEFORE YOU START
BEFORE YOU START
11
10
Select the User
1.When the monitor is off , press and hold the MEM button to enter user setting
mode. The user ID will blink.
2.Then press MEM button again, select the user ID between user 1 and user 2.
3. After selecting the suitable user ID, press SET button to confirm. Then the LCD
will turn off.
Pair-up the Blood Pressure Monitor
with Your Device
1.Turn on Bluetooth and the app. Make sure both are ON when pair-up is proceeding.
2.When the monitor is OFF, press and hold the START/STOP button to start pair-up.
The bluetooth symbol will blink, indicating pair-up is proceeding.
If SUCCEED, symbol will be shown on the LCD.
If FAIL, only bluetooth symbol
will be shown on the LCD.
4.The monitor will shut off after Pair-up process is complete.
3.Then please select the user ID you want to connect with your smartphone on the app to
continute the pair-up.
Bluetooth Module No.: AW2540MV1 RF Frequency Range: 2402 MHz to 2480 MHz Output Power Range: -1 dBm Supply Voltage: 2V-3.6 V Transmitting Distance: 10 meters
BEFORE YOU START BEFORE YOU START
13
12
Rest for 5 minutes before
measuring.
Wait at least 3 minutes between measurements. This allows your blood circulation to recover.
For a meaningful comparison, try to measure under similar conditions. For example, take daily measurements at approximately the same time, position of upper arm, or as directed by a physician.
Tie the cuff
1.Tie the cuff on your upper arm, then position the tube off-center toward the inner side of arm in line with the little finger.
2.The cuff should be snug but not too tight. You should be able to insert one finger between the cuff and your arm.
3.Sit comfortably with your tested
arm resting on a flat surface.
2~3cm
.Patients with Hypertension:
The middle of the cuff should be at the level of the right atrium of the heart; Before starting measurement, please sit comfortably with legs uncrossed,
feet flat on the floor, back and arm supported.
4
1.When the monitor is off, press the “START/STOP” button to turn
on the monitor, and it will finish the whole measurement. (Take User 1 for example.)
Adjust to zero. LCD display
Inflating and measuring.
Display and save the measurement results.
Start the Measurement
MEASUREMENT MEASUREMENT
15
14
3.Press the “START/STOP” button to power off, otherwise it will turn off within 1 minute.
If the data transmission fails, the LCD will display .
If the data transmission succeeds, the LCD will display .
2.This device will proceed
to data transmission after measurement. The Bluetooth symbol blinks on the LCD indicates data is transmitting.
Tips: Maximum 60 records are both for User 1 and User 2.
Recall the Records
1. When the monitor is off, please press “MEM” button to show the average value of the latest three records. (Take User 1 for example.)
2. Press “MEM” button or “SET” button to get the record you want.
The most recent record (1) is shown first. Each new measurement is assigned to the first (1) record. All other records are pushed back one digit (e.g., 2 becomes 3, and so on), and the last record (60) is dropped from the list.
The current No. is No. 6. The corresponding
time is 9:37 P.M..
The corresponding date is April 19th.
CAUTION
The order, date and time of the record will be shown alternately.
DATA MEASUREMENTMEASUREMENT
17
16
If you did not get the correct measurement, you can delete all
results by following steps below.(Take User 1 for example)
Delete the Records
About the Clock mode
If you set the clock mode on in the setting mode, when you turn off the blood pressure monitor, the backlight of the LCD will turn off, the LCD will display the current time.
When the backlight of the LCD is off, press any buttons to light it up, the following display will show.
Hold pressing the Lock button until the LCD displays “OFF”, this indicates the touch keys (such as MEM, START/STOP, SET) have been locked.
Hold pressing the Lock button until the LCD displays “ON” to unlock the keys.
About the Lock Button
The unnecessary keys’ touch will make the blood pressure monitor turn on and waste electricity. To avoid this, you can press the Lock button to lock the keys if necessary.
1.Hold pressing “MEM” button for 3 seconds when the monitor is in the memory recall mode ,the flash display “ User ID+ dEL ALL” will show.
2.Press “SET” button to confirm deleting and the monitor will display “dEL dOnE” and then turn off.
3. If there is no record. the following display will show.
Note: To exit out of delete mode without deleting any records, press START/STOP button before pressing "SET" to confirm any delete commands.
DATA MANAGEMENT SPECIAL FUNCTION
19
18
Tips for Measurement
Within 1 hour
after dinner or drinking
Within 20 minutes after taking a bath
In a very cold environment
Immediate measurement after tea, coffee, smoking
When talking or moving your fingers
When you want to discharge urine
Measurements may be inaccurate if taken in the following circumstances.
Maintenance
In order to get the best performance, please follow the
instructions below.
Put in a dry place and avoid the sunshine
Avoid intense shaking
and collisions
Using wet cloths to remove dirt
Avoid touching water,
clean it with a dry cloth in case.
Avoid dusty and unstable
temperature environment
Do not attempt to clean the reusable cuff with water and never immerse the cuff in water.
MEM
SET
START STOP
MEM
SET
START
STOP
MEM
SET
START
STOP
MEM
SET
START STOP
MEM
SET
START
STOP
INFORMATION FOR USER
INFORMATION FOR USER
21
20
What are systolic pressure and diastolic pressure?
press
artery
vein
blood discharging
Systolic
relax
blood entering
Diastolic
When ventricles contract and pump blood out of the heart, the blood pressure reaches its maximum value in the cycle, which is called systolic pressure. When the ventricles relax, the blood pressure reaches its minimum value in the cycle, which is called diastolic pressure.
What is the standard blood pressure classification?
Irregular Heartbeat Detector
CAUTION
The appearance of the IHB icon indicates that a pulse irregularity consistent with an irregular heart­beat was detected during measurement. Usually this is NOT a cause for concern. However, if the symbol appears often, we recommend you seek medical advice. Please note that the device does not replace a cardiac examination, but serves to detect pulse irregularities at an early stage.
An irregular heartbeat is detected when a heartbeat rhythm varies while the unit is measuring the systolic and diastolic blood pressure.During each measurement, this equipment records the heartbeat intervals and works out the standard deviation. If the calculated value is larger than or equal to 15,the irregular heartbeat symbol appears on the symbol when the measurement results are displayed.
Why does my blood pressure fluctuate throughout the day?
Is the result the same if measuring on the right arm?
Why do I get a different blood pressure at home compared to the hospital?
1. Individual blood pressure varies multiple times everyday. It is also affected by the way you tie your cuff and your measurement position, so please take the measurement under the same conditions.
2.If the person takes medicine, the
pressure will vary more.
3.Wait at least 3 minutes for another
measurement.
The blood pressure is different even throughout the day due to weather, emotion, exercise etc, Also, there is the “white coat” effect, which means blood pressure usually increases in clinical settings.
What you need to pay attention to when you measure your blood pressure at home:
If the cuff is tied properly. If the cuff is too tight or too loose. If the cuff is tied on the upper arm. If you feel anxious. Taking 2-3 deep breaths before
beginning will be better for measuring.
Advice: Relax yourself for 4-5
minutes until you calm down.
It is ok for both arms, but there will be some different results for different people. We suggest you measure the same arm every time.
The chart on the right is the standard blood pressure classification published by American Heart Association (AHA).
Only a physician can tell your normal BP range. Please contact a physician if your measuring result falls out of the range. Please note that only a physician can tell whether your blood pressure value has reached a dangerous point.
CAUTION
AHA Home Guideline for Upper Limit of Normal BP
SYS 135 mm Hg
DIA 85 mm Hg
Blood Pressure Category
Normal
Prehypertension
High Blood Pressure
(Hypertension) Stage 1
High Blood Pressure
(Hypertension) Stage 2
Hypertensive Crisis
(Emergency care needed)
Systolic mmHg (upper#)
Diastolic mmHg (lower#)
less than 120
120-139
140-159
160 or higher
Higher than 180
and
or
or
or
or
less than 80
80-89
90-99
100 or higher
Higher than 110
This chart reflects blood pressure categories defined by American Heart Association.
ABOUT BLOOD PRESSUREABOUT BLOOD PRESSURE
22
23
This section includes a list of error messages and frequently asked questions for problems you may encounter with your blood pressure monitor. If the products not operating as you think it should, check here before arranging for servicing.
About 22cm~32cm or 22cm~42cm
Type BF applied part
WARNING: No modification of this equipment is allowed.
Temperature:-20-60 Relative Humidity: 10%RH-93%RH Atmospheric Pressure: 50kPa-106 kPa
Temperature:5 to 40
Relative humidity: ≤85%RH
Atmospheric pressure: 86kPa to 106kPa
Power supply
Battery powered mode:
6VDC 4×AAA alkaline batteries
AC adaptor powered mode:
6V 1A (Please only use the recommended AC adaptor model).
Display mode
Measurement mode
Oscillographic testing mode
Measurement range
Measurement perimeter
of the upper arm
Net Weight
Approx.250g(Excluding the dry cells and cuff)
External dimensions
Attachment
Mode of operation
Continuous operation
Degree of protection
Protection against ingress of water
IP21
Accuracy
Normal working condition
Storage & transportation
condition
Software Version V01
Pressure:
5-40within±0.4kPa(3mmHg)
pulse value:±5%
Rated cuff pressure: 0kPa - 40kPa (0mmHg~300mmHg) Measurement pressure: 5.3kPa-30.7kPa (40mmHg-230mmHg) pulse value: (40-199) beat/minute
Digital LCD V.A.84mm×73mm
Approx.107mm×103mm×118mm
4×AAA alkaline batteries,user manual
PROBLEM SYMPTOM CHECK THIS REMEDY
No power
Low batteries
Error massage
Display will not
light up.
Batteries are exhausted.
Replace with new batteries
Insert the batteries
correctly
Replace with new batteries
Batteries are inserted incorrectly.
Display is dim or show
Batteries are low.
Err shows
The cuff is not secure.
Refasten the cuff and then measure again.
E 1 shows
E10 or E11 shows
E20 shows
The measurement process does not detect the pulse signal.
Loosen the clothing on the arm and then measure again.
EExx,shows on the display.
A calibration error occurred.
Retake the measurement. If the problem persists, contact the retailer or our customer service department for further assistance.Refer to the warranty for contact information and return instructions.
E21 shows The treatment of the
measurement failed.
Relax for a moment and then measure again.
AC adaptor is inserted incorrectly.
Insert the AC adaptor
tightly
The monitor detected motion,talking or the pluse is too poor while measuring.
Relax for a moment and then measure again.
Data communication is failed.
Check if the App/Bluetooth is on or not,try data transmission again.
E 3 shows
The pressure of the cuff is excess.
Relax for a moment and then measure again.
E 2 shows The cuff is very tight
Refasten the cuff and then measure again.
TROUBLESHOOTING SPECIFICATIONS
24
25
Contact Information
For more information about our products, please visit www.transtek.cn.you can get customer
service, usual problems and customer download, transtek will serve you anytime.
Manufactured by: Company: Address:
Authorized Component
1.please use the TRANSTEK
authorized adapter.
Guangdong Transtek Medical Electronics Co., Ltd.
Zone A, No.105 ,Dongli Road, Torch Development District, Zhongshan,528437,Guangdong,China
Guangdong Transtek Medical Electronics Co., Ltd.
Complied Standards List
Risk management
Labeling
User manual
General Requirements
for Safety
Electromagnetic
compatibility
Performance requirements and Clinical investigation
Software life-cycle
processes
ISO/EN 14971:2012 Medical devices — Application of risk management to medical devices
ISO/EN 15223-1:2012 Medical devices. Symbols to be used with medical device labels, labelling and information to be supplied. General requirements
EN 1041: 2008 Medical equipment manufacturers to provide information
IEC 60601-1: 2005+A12012 Medical electrical
equipment - Part 1: General requirements for basic safety and essential performance
IEC 60601-1-11 Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
IEC/EN 60601-1-2:2007 Medical electrical equipment ­Part 1-2: General requirements for basic safety and essential performance - Collateral standard:Electromagnetic compatibility - Requirements and tests
IEC 80601-2-30:2009 Medical electrical equipment­Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers
IEC/EN 62304:2006+AC: 2008 Medical device
software - Software life cycle processes
Usability
IEC 62366 Medical devices - Application of usability
engineering to medical devices (IEC 62366:2007)
IEC 60601-1-6 Medical electrical equipment - Part 1
-6 : General requirements for basic safety and essential performance - collateral standard : Usability
ISO81060-2 Non-invasive sphygmomanometers — Part 2: Clinical validation of automated measurement type
Adapter Type:KH0601000UW Input:100~240V~
50/60Hz, 0.4A Max
Output:6V 1000mA
AUTHORIZED COMPONENT COMPLIED STANDARDS LIST
26
27
EMC Guidance
1) This equipment needs to be installed and put into service in accordance with the information provided in the user manual;
2) Wireless communications equipment such as wireless home network devices, mobile phones, cordless telephones and their base stations, walkie-talkies can affect this equipment and should be kept at least a distance d=3,3m away from the equipment.
(Note: As indicated in Table 6 of IEC 60601-1-2:2007 for ME EQUIPMENT, a typical cell phone with a maximum output power of 2 W yields d=3, 3m at an IMMUNITY LEVEL of 3V/m)
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
FCC ID: OU9TMB1583-B
FCC STATEMENT EMC GUIDANCE
28
29
Loading...