Transition Networks TR-CF-01, TR-CF-01(SM) User Manual

Both media converters function at 4Mb/s or 16Mb/s in half-duplex mode or, when connected to devices capable of full-duplex connectivity, in full-duplex mode for up to 32Mb/s total throughput.
MEDIA CONVERTER TECHNICAL SPECIFICATIONS
Standards IEEE 802.5, 802.5j Case dimensions 4.75" x 3.0" x 1.0" (119mm x 76mm x 25mm) Shipping Weight 2 pounds (0.9 kilograms) Delay 50nsec round trip Environment Temperature: 0-40°C (32° to 104° F )
Humidity 10-90%, non condensing Altitude 0-10,000 feet
Warranty Five years
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Compliance Information
UL Listed C-UL Listed (Canada) CISPR/EN55022 Class A
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Copyright Restrictions
© 1998 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners. 33086.B
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
Power Supply Requirements Replace power supply with only the equivalent input
rating (see below) and output rating (regulated 9VDC at 550 mA).
TN PN Requirement Location 3517 240 volts, 50 hertz United Kingdom 3516 230 volts, 50 hertz Europe 3518 120 volts, 60 hertz USA/Canada/Mexico 3514 100 volts, 50-60 hertz Japan 3515 240 volts, 50 hertz Australia
The TRANSITION Networks Token Ring copper-to-fiber media converters connect either unshielded or shielded Token Ring twisted-pair copper cable to multimode fiber-optic cable (TR-CF-01) OR to singlemode fiber-optic cable (TR-CF-01(SM)).
Minneapolis, MN 55344 USA
Token Ring Copper/Fiber Media Converters
TR-CF-01, TR-CF-01(SM)
USER’S GUIDE
TR-CF-01
UTP/STP Copper
Multimode Fiber
S/RO C/RI
9V DC Input
TR-CF-01
UTP/STP
Fiber
Token Ring Twisted Pair to
Fiber Media Converter
RJ-45
Pinning
Config
Switches
1 2 3 4
TR-CF-01(SM)
UTP/STP Copper
Singlemode Fiber
S/RO C/RI
9V DC Input
TR-CF-01(SM)
UTP/STP
Fiber
Token Ring Twisted Pair to
Fiber Media Converter
RJ-45
Pinning
Config
Switches
1 2 3 4
TR-CF-01
Provides a Token Ring RJ-45 twisted-pair connector and an RX (receive) and a TX (transmit) ST connector to multimode fiber-optic cable for fiber network extension distances up to 2 kilometers.
TR-CF-01(SM)
Provides a Token Ring RJ-45 twisted-pair connector and an RX (receive) and a TX (transmit) ST connector to singlemode fiber-optic cable for fiber network extension distances up to 15 kilometers.
P(o)w(e)r Steady green LED indicates connection to external AC power. Ins(erted) Steady green LED indicates twisted-pair and fiber connections negotiated link. S(ignal) D(etect) C(opper) Steady green LED indicates twisted-pair link is up and
ready to insert.
S(ignal) D(etect) F(iber) Steady green LED indicates fiber link is up and ready to
insert.
NOTE: The fiber interface LEDs are NOT illuminated until the twisted-pair side has been initialized and asserts a phantom voltage to the fiber. (See a description of the activity of the Token Ring twisted-pair to fiber signal in “Media Converters in the Network” on page 4.)
Status LEDs:
Norm(al) Used for most network operation. L(oop-back) S(witch) Used ONLY at the direction of
Transition Networks Technical Support. NOTE: For more information, go to www.transition.com/support, select Tech Tips, and then select the Token Ring media converter.
Switch:
10BASE-T
Fiber
RX
TX
Twisted-pair
Fiber
UTP/STP
Pwr
SDC
Ins
SDF
Norm
Pwr
SDC
Ins
SDF
Norm
LS
2
TOKEN RING CABLE SPECIFICATIONS
INSTALLATION NOTES
Twisted-pair Cable
• Category 5 twisted-pair cable is recommended; Category 3 and 4 are supported at reduced cable lengths.
Fiber Extension Cable
• Be certain that the fiber extension cable is correct for distances required at the site installation.
Switches
• Switches on the side of the media converter are used to configure each media converter according to its location in the Token Ring network. SET THE SWITCHES ON THE MEDIA CONVERTER
BEFORE CONNECTING TO POWER.
Using the switch setting references on page 3 and pages 4-5:
• Be certain that the media converter mode is set correctly for the
site installation
• Be certain that the media converter active/passive state is set
correctly for the site installation
• Be certain that the media converter IEEE 802.5j compliance
/non-compliance state is set correctly for the site installation
• Be certain that the twisted-pair cable configuration is set
correctly (straight through/RO or crossover/RI) for the site installation.
Power Connections
• Install the media converter with the power supply provided. (Output 9 VDC regulated, 550 mA).
• Connect the power supply cable to the media converter BEFORE connecting the power supply cable to the AC outlet.
• Do NOT connect more than two media converters in series.
T R
-
C
F
-
0 1
Token Ring Twisted Pair to
Fiber Media Converter
S/RO C/RI
RJ-45 Pinning
Config Switches
1 2 3 4
1234
T
R
-
C
F
-
0
1
Token Ring Twisted Pair to
Fiber Media Converter
S/RO C/RI
RJ-45
Pinning
Config
Switches
1 2 3 4
1234
Twisted-pair
Twisted-pair
Fiber Network Extension
2 kilometers - multimode 15 kilometers - singlemode
The physical characteristics of the media cable must meet or exceed IEEE 802.5 and 802.5j specifications.
7
Fiber Cable and Connector Specifications
Cable Characteristics:
MULTIMODE
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber Fiber Optic Transmitter Power: min: -19.0
dBm max: -14.0 dBm
Fiber Optic Receiver Sensitivity: min: -32.5 dBm
max: -14.0 dBm Wavelength: 850nM Bit error rate: 10
-9
Maximum Cable Distance: 2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended: 9 µm singlemode fiber Fiber Optic Transmitter Power: min: -25.0
dBm max: -22.0 dBm
Fiber Optic Receiver Sensitivity: min: -32.5 dBm
max: -14.0 dBm Wavelength: 1300nM Bit error rate: 10
-9
Maximum Cable Distance: 15 kilometers
Connector Characteristics:
ST type connectors (SMA type available upon request)
Twisted Pair Cable and Connector Specifications
Cable Characteristics:
Category 3 wire or better is required; category 5 wire is recommended. Either shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.
Category 3:
Gauge 24 to 22 AWG Attenuation 28 dB/1000’ @ 10 MHz Differential Characteristic Impedance 100 ±10% @ 10 MHz
Category 5:
Gauge 24 to 22 AWG Attenuation 20 dB/1000’ @ 10 MHz Differential Characteristic Impedance 100 ±10% @ 10 MHz
Maximum Cable Distance: 50 meters (165 feet) Connector Characteristics:
Twisted pair connection requires two active pairs configured as straight through. The two active pairs in a Token Ring network are pins 4 & 5 and pins 3 & 6. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins.
3 4
5 6
Twisted Pair #1
Twisted Pair #2
Straight Through Cable
3 4
5 6
Loading...