Transition Networks NDM-FTX-MT-01(L), NDM-FTX-SC-01(L), NDM-FTX-SB201-01(L), NDM-FTX-SB202-01(L), NDM-FTX-SC20-01(L) User Manual

...
USER’S GUIDE
NDM-FTX-xxxxx-01 (standard) NDM-FTX-xxxxx-01(L) (low profile)
Fast Ethernet Fiber/Dual Media NICs
Fast Ethernet
• Copper and Fiber
• 10/100Base-TX and/or 100Base-FX
Transition Networks NDM-FTX series fast Ethernet dual media NIC (Network Interface Card) provides a 10/100Base­TX copper port and a 100Base-FX fiber port for installation flexibility in a mixed-media environment. The dual
ports can also provide redundancy for critical applications. These NICs come in standard and low profile form factors, and include driver support for a variety of operating systems.
NDM-FTX-ST-01 NDM-FTX-ST-01(L)
RJ-45 100 m (328 ft)*
ST, 1300 nm multimode 2 km (1.2 miles)*
NDM-FTX-SC-01 NDM-FTX-SC-01(L)
RJ-45 100 m (328 ft)*
SC, 1300 nm multimode 2 km (1.2 miles)*
NDM-FTX-MT-01 NDM-FTX-MT-01(L)
RJ-45 100 m (328 ft)*
MT-RJ, 1300 nm multimode 2 km (1.2 miles)*
NDM-FTX-SC5-01 NDM-FTX-SC5-01(L)
RJ-45 100 m (328 ft)*
SC, 1310 nm single mode 5 km (3.1miles)*
RJ-45 100 m (328 ft)*
SC, 1310 nm single mode 20 km (12.4 miles)*
RJ-45 100 m (328 ft)*
NDM-FTX-SB201-01 NDM-FTX-SB201-01(L)
RJ-45 100 m (328 ft)*
SC, 1550 TX/1310 nm RX single mode, single fiber 20 km (12.4 miles)*
SC, 1310 TX/1550nm RX single mode, single fiber 20 km (12.4 miles)*
NDM-FTX-SC20-01 NDM-FTX-SC20-01(L)
NDM-FTX-SB202-01 NDM-FTX-SB202-01(L)
Part Number Port One - Copper
10/100Base-TX
Port Two - Duplex Fiber-Optic 100Base-FX
*Typical maximum cable distance. Actual distance is dependent upon the physical characteristics of the network installation.
Installation . . . . . . . . . . . . . . . . . . .2
Cable Specifications . . . . . . . . . . .4
Technical Specifications . . . . . . . .5
Troubleshooting . . . . . . . . . . . . . . .6
Contact Us . . . . . . . . . . . . . . . . . . .7
NDM-FTX-xxxxx-01
Part Number Description
BTR-NDM-RPL RPL, Bootable ROM Chip BTR-NDM-PXE PXE, Bootable ROM Chip
Optional accessories sold separately
Installation
Checklist
Before installing the NDM-FTX, verify that the package contains the following items:
• NDM-FTX Board
• LAN Driver CD
Please notify your sales representative if any item is missing or damaged.
Description
The NDM-FTX module has a bootable ROM socket (ROM chip sold separately). The two LED indicators, LINK/ACT and FDX located on the bracket, show network/board link, activities, collision, and full-duplex statuses. See Figure 1.
NDM-FTX module installation
CAUTION: Wear a grounding strap and observe electrostatic discharge precautions when installing the NDM-FTX module. Failure to observe this caution could result in damage or failure of the NDM-FTX module.
To install the NDM-FTX module, do the following:
Important: Install the NDM-FTX module in a “master slot” only.
1. Locate a master slot on the PC workstation or file server.
2. Remove the cover from the PC workstation or file server—keep all screws.
3. Remove and keep the screws holding the cover over the installation slot.
4. Carefully slide the NDM-FTX module into the “master slot,” aligning the module with the slot guides.
NDM-FTX Series Fast Ethernet Dual Media NIC
2
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600, 24 hours
Figure 1: LEDs and Boot ROM Socket
Install the NDM-FTX module -- continued
5. Ensure that the module is firmly seated in the slot.
6. Use the screws from step “3” to secure the module to the workstation or file server housing.
NDM-FTX PCI module configuration
For motherboards with automatic PCI configuration:
No specific setup is needed.
You can enter the system BIOS setup menu to view or specify the interrupt (INT) line of the PCI slots.
For motherboards with bus master and interrupt jumpers:
Enable bus master operation in a selected PCI slot and select an INT request line (IRQ) level, using the appropriate motherboard jumper.
Enable I/O on the NDM-FTX, PCI slot.
PCI bus system and configuration
Ensure that the PCI machine supports master slots, INT multiple sharing and timing compatibility.
DO NOT install NDM-FTX in PCI slave slots. Please refer to your PCI system manual and select the appropriate configuration settings.
When installing multiple NDM-FTX boards in a server station, you should correctly configure the IRQ settings of the PCI slot.
Up to four NDM-FTX modules can be installed in a PCI file server running NetWare operating system.
NDM-FTX server modules share the same INT line with the driver supporting multiple INT services at a time. The IRQ of each NDM-FTX module should not conflict with other boards.
Operation in full or half-duplex mode is configured by LAN driver options. The operating mode should match the working status of the remote link device.
Use EMM386 version 4.49 or higher, and install both DOS and EMM386 from the same DOS package to avoid software problems.
techsupport@transition.com -- Click the “Transition Now” link for a live Web Chat.
3
NDM-FTX Series Fast Ethernet Dual Media NIC
4
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600, 24 hours
The physical characteristics must meet or exceed the IEEE 802.3 specification.
Fiber cable
Bit error rate: <10-9 Single mode fiber (recommended): 9 µm Multimode fiber (recommended): 62.5/125 µm Multimode fiber (optional): 100/140, 85/140, 50/125 µm
NDM-FTX-ST-01(x), NDM-FTX-SC-01(x), NDM-FTX-MT-01(x) 1300 nm multimode Fiber optic transmitter power: min: -19.0 dBm max: -14.0 dBm Fiber optic receiver sensitivity: min: -31.0 dBm max: -17.0 dBm Link budget: 12.0 dB
NDM-FTX-SC5-01(x) 1310 nm single mode Fiber optic transmitter power: min: -19.0 dBm max: -14.0 dBm Fiber optic receiver sensitivity: min: -31.0 dBm max: -7.5 dBm Link budget: 12.0 dB
NDM-FTX-SC20-01(x) 1310 nm single mode Fiber optic transmitter power: min: -15.0 dBm max: -8.0 dBm Fiber optic receiver sensitivity: min: -31.0 dBm max: 0.0 dBm Link budget: 16.0 dB
NDM-FTX-SB201-01(x) 1310 TX/1550 RX nm single mode
single stand Fiber optic transmitter power: min: -14.0 dBm max: -8.0 dBm Fiber optic receiver sensitivity: min: -32.0 dBm max: 0.0 dBm Link budget: 18.0 dB
Cable Specifications
Copper cable
10BASE-T UTP Category 3, 4, 5 or higher 100Base-TX UTP Category 5 or higher Gauge: 24 to 22AWG Attenuation: 22.0 dB /100m @ 100 MHz
• Straight-through MDI twisted-pair cable must be used.
• Shielded STP or unshielded UTP twisted-pair cable may be used.
• Pins 1 and 2, 3 and 6 are the two active pairs in an Ethernet network.
• RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins:
(e.g., blue/white and white/blue, orange/white and white/orange, etc.)
• DO NOT use flat or silver satin wire.
1 2
3 6
Straight-Through Cable
Twisted Pair #1
Twisted Pair #2
1 2
3 6
techsupport@transition.com -- Click the “Transition Now” link for live Web chat.
5
Technical Specifications
For models NDM-FTX-xxxxx-01 and NDM-FTX-xxxxx-01(L)
Standards: IEEE 802.3 Expansion bus standard: PCI 2.1, 2.2 Data rate: 10/100Mpbs twisted pair media
100Mbps fiber media
LED: LINK/ACT (on the bracket)
ON = communication link; flashing = activity on link FDX (full duplex link); ON = full duplex link
Drivers: • NetWare Server 4.1x, 5.x
• Netware DOS Client ODI
• Windows 95, 98, 2000, 2003, XP, NT4.0
• Linux Boot server support: Novell RPL Boot ROM; PXE Boot ROM PCB dimensions: 2.5” W x 5.9” D x 0.85” H
(63.5 mm W x 149.9 mm D x 21.6 mm H)
Weight: 3 oz. (91g) approximate Power consumption: 1.0A @ +5VDC MTBF 198,853 hours (Bellcore7 V5.0) Operating temp 0°C to 50°C (32°F to 122°F) Storage temp: -25°C to 85°C (-13°F to 185°F) Humidity: 5% to 90%, non-condensing Altitude: 0 to 10,000 feet Warranty: Lifetime
WARNING: Visible and invisible laser radiation when open: DO NOT stare into the beam or view directly with optical instruments. Failure to observe this warning could result in damage to your vision or blindness.
CAUTION:
Use of controls, adjustments, or the performance of procedures other
than those specified herein may result in hazardous radiation exposure.
The information in this manual is subject to change without further notice.
Fiber cable -- continued
NDM-FTX-SB202-01(x) 1550 TX/1310 RX nm single mode
single stand Fiber optic transmitter power: min: -14.0 dBm max: -8.0 dBm Fiber optic receiver sensitivity: min: -32.0 dBm max: 0.0 dBm Link budget: 18.0 dB
The fiber optic transmitters on the device meet Class I Laser safety requirements per IEC­825/CDRH standard and comply with 21CRF1040.10 and 21CRF1040.11.
NDM-FTX Series Fast Ethernet Dual Media NIC
6
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600, 24 hours
Troubleshooting
Diagnostics LEDs and Boot ROM
LEDS
The LINK/ACT LED lights when a fiber cable or twisted pair cable connection is good. It blinks to indicate activity.
The collision and full-duplex LED report board operating status.
Boot ROM
To add the remote boot feature to a workstation, insert the Boot ROM into the ROM socket. See Figure 1 on page 2.
After power UP, the LINK/ACT LED should light; if not, check the following:
1 Confirm that the NDM-FTX module is properly inserted into the PC
workstation master slot or file-server master slot.
2 Confirm that the PC workstation or the file server is properly connected to
a power source and with the power source turned ON.
3 Check the fiber cable and twisted-pair copper cables for proper connection.
4 Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600 if those
steps fail to produce the desired result.
Note: To connect this device to a router, bridge, or switch, please refer to the
corresponding technical manual for the device.
Declaration of Conformity
Name of Mfg: Transition Networks, 6475 City West Parkway,
Minneapolis, MN 55344 U.S.A.
Model: NDM-FTX-xxxxx-0l and NDM-FTX-xxxxx-0l(L) Network Interface
Cards
Part Number: NDM-FTX-ST-01(x), NDM-FTX-SC-01(x), NDM-FTX-MT-01(x),
NDM-FTX-SC5-01(x), NDM-FTX-SC20-01(x), NDM-FTX-SB201-01(x), NDM-FTX-SB202-01(x)
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the NDM-FTX-xxxxx-01 and NDM-FTX-xxxxx-0l(L), to
which this declaration refers, is in conformity with the following standards:
CISPR 22:1997+A1:2000; EN 55022:1998+A1:2000 Class A; FCC Part 15 Subpart B; 21CFR subpart J
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and
Standard(s).
June 30, 2005
Stephen Anderson, Vice-President of Engineering Date
7
techsupport@transition.com -- Click the “Transition Now” link for live Web chat.
Contact Us
Technical support
Technical support is available at techsupport@transition.com
• US and Canada: 1-800-260-1312 (24 hours)
• International: 00-1-952-941-7600 (24 hours)
Transition now
Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link.
Web-based seminar
Transition networks provides seminars via live, web-based training. Log onto www.transition.com and click the Learning Center link.
Email
Ask a question anytime by sending an email to our technical support staff: techsupport@transition.com
Address
Transition Networks
6475 City West Parkway
Minneapolis, MN 55344, U.S.A.
Telephone: 952-941-7600,
Toll free: 800-526-9267
Fax: 952-941-2322
33332.A
Printed in the US Manual Part Number and Rev.
Compliance Information
CISPR22/EN55022 Class A, CE Mark, CISPR22/EN55022 Class A + EN55024, CE Mark
FCC regulations
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense.
Canadian regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European regulations
Caution: This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures. Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für Gegenmaßnahmen verantwortlich.
Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG­Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
Trademark notice
All registered trademarks and trademarks are the property of their respective owners.
Copyright restrictions
© 2004-2005 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means—graphic, electronic or mechanical—without written permission from Transition Networks
Loading...