Transition Networks CSDTF3011-110, CSDTF3012-110, CSDTF3013-110, CSDTF3014-110, CSDTF3015-110 User Manual

...
COMPLIANCE INFORMATION
UL Listed C-UL Listed (Canada) CISPR22/EN55022 Class A + EN55024 CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques appropriées
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners.
Copyright Restrictions
© 2001 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Printed in the U.S.A. 33219.A
12
TRANSITION Networks CSDTF30xx-110 series media converters, designed to be installed in a TRANSITION Networks
PointSystem™media conversion center
, encode and decode E1 coax copper signals over duplex fiber-optic cable to extend the distance and transmission reliability of high speed E1 data traffic.
*In CSDTF30xx model designation, 30 represents the E1 coax input and output connectors; xx represents the selectable fiber connector installed on the media converter.
E1 Coax Copper to Fiber
Slide-In-Module Media Converters
CSDTF30xx*-110
USER’S GUIDE
CSDTF3011-110
Provides a set of coax copper input and output connectors for E1 signals and a set of RX/TX ST connectors to 850 nm
multimode duplex fiber-optic cable.
CSDTF3012-110
Provides a set of coax copper input and output connectors for E1 signals and an RX/TX ST connector to 1300 nm
singlemode duplex fiber-optic cable.
CSDTF3013-110
Provides a set of coax copper input and output connectors for E1 signals and an RX/TX SC connector to 850 nm
multimode duplex fiber-optic cable.
CSDTF3014-110
Provides a set of coax copper input and output connectors for E1 signals and an RX/TX SC-SM connector to 1300 nm
singlemode duplex fiber-optic cable.
CSDTF3015-110
(long haul)
Provides a set of coax copper input and output connectors for E1 signals and an RX/TX SC-LH connector to 1300 nm
singlemode duplex fiber-optic cable.
CSDTF3022-110
(long haul)
Provides a set of coax copper input and output connectors for E1 signals and an RX/TX ST connector to 1300 nm singlemode duplex fiber-optic cable.
CSDTF30xx in the Network . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . .4
Operation . . . . . . . . . . . . . . . . . . . . .7
Fault Isolation and Correction . . . . .8
Cable Specifications . . . . . . . . . . . . .9
Technical Specifications . . . . . . . . .11
Compliance Information . . . . . . . . .12
CSDTF30xx IN THE NETWORK
NOTE: E1 MEDIA CONVERTERS MUST BE USED IN PAIRS. A TRANSITION Networks CSDTF30xx stand-alone media converter can be used with another CSDTF30xx stand-alone media converter, with a SSDTF30xx chassis media converter, or with a previous model TRANSITION Networks T1/E1 media converter, such as a C/T1E1-CF-01 or a T1E1-CF-01.
Media converter is framing independent (as ESF vs D4) and supports all common line codes, (AMI, B8ZS, HDB3).
All Ones Insertion (AIS) on loss of signal at copper and/or fiber interface.
TECHNICAL SPECIFICATIONS
Standards
Emissions
: CISPR A
E1 Physical Layer
: ITU-T, TBR12 British Technical Publication: PD7024 (NTR4), ANSI, AT&T, ETSI, EN 45001
Dimensions 2.9" x 4.8" x 1.4"
Weight 8 oz (approximate)
Power Consumption 5 watts
Environment Typical Operating Temperature*: 0°
to 50°C (32° to 122°F )
Storage Temperature: -20°
to
85°C (-4° to 185°F)
Humidity 10-90%, non condensing
Altitude 0-10,000 feet
Warranty Lifetime
*Operating temperature range for this Slide-In-Module depends on the physical characteristics and the installation configuration of the TRANSITION Networks chassis in which this Slide-In-Module will be installed. See the User’s Guide
for
the chassis in which this Slide-In-Module will be installed
for a discussion of
temperature-related installation constraints.
CSDTF30xx
112
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA Model: CSDTF30xx Series E1 Coax Copper-to-Fiber Media Converter Part Number: CSDTF3011-110, CSDTF3012-110, CSDTF3013-110,
CSDTF3014-110, CSDTF3015-110, CSDTF3022-110
Regulation: EMC Directive 89/336/EEC Purpose: To declare that the
CSDTF30xx
to which this declaration refers is in
conformity with the following standards. EN 55022:1994; EN 55024:1998; FCC Part 15 Class A; EN 60950 A4:1997; UL 1950
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
_July 8, 2001_____
Stephen Anderson, Vice-President of Engineering Date
CABLE SPECIFICATIONS (continUed)
Coax Copper Cable
E1:
Cable Type RG-58 Gauge 24 to 22 AWG Attenuation 2 dB/100 meters @ 1.0 MHz Differential Characteristic Impedance 75 ±10%
Switch-Selectable Functions
LOOPBACK TEST FUNCTION
A loopback switch facilitates installation and network debug procedures. The path for the CSDTF30xx loopback is shown:
TRANSMIT ALL ONES FUNCTION
A selectable Transmit All Ones switch on the fiber interface AND on the copper interface allows for insertion of an “all ones” pattern on the interface whenever
signal detect
is lost. The “all ones” pattern creates an
alarm condition at the equipment connected to the interface.
CSDTF30xx
3 10
INSTALLATION
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when setting switch and when installing Media Converter Slide-in-Module in the media conversion center. Failure to observe this caution could result in damage to, and subsequent failure of, the Media Converter Slide-in-Module.
Set Loopback Test Switch
NOTE: The Loopback Test switch, located on Media Converter Slide-in­Module front panel, allows the network administrator to enable a loopback test for installation and network debug procedures.
Use small flatblade screwdriver or similar device to set
Loopback Test switch.
Set 4-Position Switch
Use small flatblade screwdriver or similar device to set mode switches located on
Media Converter Slide-in-
Module
circuit board.
NOTE: E1 MUST BE SELECTED (by setting #4: DOWN) FOR PROPER OPERATION.
CABLE SPECIFICATIONS
Fiber Cable
Bit error rate: 1 0
-9
MULTIMODE
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber
Optional: 100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber CSDTF3011-110 850 nM Fiber Optic Transmitter Power: min: -14.0 dBm max: -12.0 dBm Fiber Optic Receiver Sensitivity: min: -25.0 dBm max: -12.0 dBm
Typical
Maximum Cable Distance*: 2 kilometers CSDTF3013-110 850 nM Fiber-optic Transmitter Power: min: -14.0 dBm max: -12.0 dBm Fiber-optic Receiver Sensitivity: min: -25.0 dBm max: -12.0 dBm
Typical
Maximum Cable Distance*: 2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended: 9 µm singlemode fiber CSDTF3012-110 1300 nM Fiber-optic Transmitter Power: min: -21.0 dBm max: -14.0 dBm Fiber-optic Receiver Sensitivity: min: -25.0 dBm max: -14.0 dBm
Typical
Maximum Cable Distance*: 8 kilometers CSDTF3014-110 1300 nM Fiber-optic Transmitter Power: min: -21.0 dBm max: -14.0 dBm Fiber-optic Receiver Sensitivity: min: -27.0 dBm max: -14.0 dBm
Typical
Maximum Cable Distance*: 8 kilometers
CSDTF3015-110
(long haul)
1300 nM Fiber-optic Transmitter Power: min: -15.0 dBm max: -5.0 dBm Fiber-optic Receiver Sensitivity: min: -27.0 dBm max: -14.0 dBm
Typical
Maximum Cable Distance*: 15 kilometers
CSDTF3022-110
(long haul)
1300 nM Fiber-optic Transmitter Power: min: -15.0 dBm max: -5.0 dBm Fiber-optic Receiver Sensitivity: min: -25.0 dBm max: -14.0 dBm
Typical
Maximum Cable Distance*: 15 kilometers
*Actual distance dependent upon physical characteristics of network installation.
CSDTF30xx
9 4
KEY
= UP
= DOWN
FAULT ISOLATION and CORRECTION
If the media converter fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action:
1. Is the P(o)W(e)R LED on the media converter illuminated?
NO
• Is the media converter inserted properly into the chassis?
• Is the power cord properly installed in the chassis and at the external power source?
• Does the external power source provide power?
• Contact Technical Support: (800) 260-1312.
YES
• Proceed to step 2.
2. Is the SDF (Signal Detect/Fiber) LED illuminated? NO
• Check fiber cables for proper connection.
• Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other media converter.
• Contact Technical Support: (800) 260-1312.
YES
• Proceed to step 3.
3. Is the SDC (Signal Detect/Copper) LED illuminated?
NO
• Check coax cables for proper connection.
• Check integrity of device attached to media converter by coax
cable.
• Contact Technical Support: (800) 260-1312.
YES
• Contact Technical Support: (800) 260-1312.
Install Slide-In-Module(s)
CAUTION : Wear a grounding device and observe electrostatic discharge precautions when installing Media Converter Slide-in­Module(s) in the media conversion center. Failure to observe this caution could result in damage to, and subsequent failure of, the Media Converter Slide-in-Module(s).
NOTE: Slide-in-Modules can be installed in any installation slot, in any order.
To install the Media Converter Slide-in-Module in the CPSMC18xx chassis:
1. Remove Media Converter Slide-in-Module protective plate from
selected installation slot by removing two screws that secure plate to front of CPSMC18xx.
2. Carefully slide Media Converter Slide-in-Module into installation slot, aligning Media Converter Slide-in-Module with installation guides.
NOTE: Ensure that the Media Converter Slide-in-Module is seated firmly against the backplane.
3. Secure Slide-in-Module to CPSMC18xx chassis by rotating captive screw attached to Slide-in-Module clockwise into chassis.
CSDTF30xx
5
8
INSTALLATION
(continued)
Install Cable
FIBER
1. Locate or build fiber cables that are compliant with specifications on page __, with male two-stranded TX to RX connectors installed at both ends.
2. Connect cable with connector installed at TX location on media converter to RX location on attached device.
3. Connect cable with connector installed at RX location on media converter to TX location on attached device.
COPPER
E1 75 OHM (COAX CONNECTOR)
NOTE: Ground coax segment to earth ground at one end.
Locate or build coax cables that are compliant with specifications on page 10.
Connect BNC connector at one end of cable to media converter.
Connect BNC connector at other end of cable to network equipment.
Power the Slide-In-Module Media Converter
NOTE: The Slide-In-Module is powered through the media conversion center.
OPERATION
Status LEDs
Use the status LEDs to monitor media converter operation in the network. SDC Signal Detect/Copper - Steady LED indicates twisted-pair
copper link is up.
Flashing LED (once/second) indicates transmitting All Ones (AIS) on link if
fiber
link (switch
selectable) is down.
Flashing LED (5 times/second) indicates All Ones detected on Link.
SDF Signal Detect/Fiber - Steady LED indicates fiber link is up.
Flashing LED (once/second) indicates transmitting All Ones (AIS) on link if
copper
link (switch selectable) is down.
Flashing LED (5 times/second) indicates All Ones detected on Link.
P(o)W(e)R Steady green LED indicates connection to external AC power.
Using SNMP*
Use SNMP at an attached terminal or at a remote location to:
Monitor media converter by monitoring:
Media Converter Power
Fiber Link Status
Copper Link Status
Hardware Switch settings
AIS detected on Fiber
AIS detected on Copper
Enter network commands that:
Enable/disable Loop-back on Fiber
Enable/disable Transmit All Ones on Fiber when Copper is down
Enable/disable Transmit All Ones on Copper when Fiber is down
Power Down Media Converter.
*See the on-line documentation that comes with TRANSITION Networks
FocalPoint
software for applicable commands and usage.
CSDTF30xx