Transition Networks CSDTF1022-100 User Manual

COMPLIANCE INFORMATION
UL Listed C-UL Listed (Canada) CISPR22/EN55022 Class A + EN55024 CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques appropriées
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners.
Copyright Restrictions
© 2001, 2002 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Printed in the U.S.A. 33201.C
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten
verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen
einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
TRANSITION Networks CSDTF10xx-100 series media converters, designed to be installed in a PointSystem
Conversion Center™chassis, encode and decode T1 or
E1 twisted-pair copper signals over duplex fiber-optic cable to extend the distance and transmission reliability of high speed T1 or E1 data traffic.
*In CSDTF10xx model designation, 10 represents the T1 or E1 RJ-45 connector; xx represents the selectable fiber connector installed on the media converter.
T1/E1 Twisted-Pair Copper
to Fiber
Slide-In-Module Media Converters
CSDTF10xx*-100
USER’S GUIDE
CSDTF1011-100
Provides an RJ-45 twisted pair copper connector for T1 or E1 signals and a set of RX/TX ST connectors to 850 nm multimode duplex fiber-optic cable.
CSDTF1012-100
Provides an RJ-45 twisted pair copper connector for T1 or E1 signals and an RX/TX ST connector to 1300 nm singlemode duplex fiber-optic cable.
CSDTF1013-100
Provides an RJ-45 twisted pair copper connector for T1 or E1 signals and an RX/TX SC connector to 850 nm multimode duplex fiber-optic cable.
CSDTF1014-100
Provides an RJ-45 twisted pair copper connector for T1 or E1 signals and an RX/TX SC-SM connector to 1300 nm singlemode duplex fiber-optic cable.
CSDTF1015-100 (long haul)
Provides an RJ-45 twisted pair copper connector for T1 or E1 signals and an RX/TX SC-LH connector to 1300 nm singlemode duplex fiber-optic cable.
CSDTF1022-100 (long haul)
Provides an RJ-45 twisted pair copper connector for T1 or E1 signals and an RX/TX ST connector to 1300 nm singlemode duplex fiber-optic cable.
CSDTF10xx in the Network . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . .3
Operation . . . . . . . . . . . . . . . . . . . . .7
Fault Isolation and Correction . . . . .8
Cable Specifications . . . . . . . . . . . .10
Technical Specifications . . . . . . . . .11
Compliance Information . . . . . . . . .12
M
50‰
PWR
PWR
SDC
SDC
SDF
PWR
DB-9
SET
LKS
LKM
RXF
LOOP
LKC
RXC
TX
Singlemode
TX
RX
RX
TX
Multimode
RX
CSDTF100
CFMFF100
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
SDF
TX
RX
CFETF100
PWR
PWR
SDC
PWR
LA
LNK
RXF
LOOP
RXC
Link Alert
E
10BASE-T
0
10BASE-2
CECF100
SDF
LKS
LKM
COL
TX
Singlemode
D
TX
RX
TX
RX
Multimode
50‰
RX
CFMFF100
CFETF110
PWR
LOOP
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CF
CSDTF10xx IN THE NETWORK
NOTE: THE CSDTF10xx REQUIRES A CSU BETWEEN THE MEDIA CONVERTER AND THE PUBLIC TELEPHONE NETWORK.
NOTE: T1/E1 MEDIA CONVERTERS MUST BE USED IN PAIRS. A TRANSITION Networks CSDTF10xx chassis media converter can be used with another CSDTF10xx chassis media converter, a SSDTF10xx stand-alone media converter, or with a previous model TRANSITION Networks T1/E1 media converter, such as a C/T1E1-CF-01 or a T1E1-CF-01.
Features
Media converter is framing independent (as ESF vs D4) and supports all common line codes, (AMI, B8ZS, HDB3).
Dry relay contacts allow media converter to be tied into separate alarm circuit
All Ones Insertion (AIS) on loss of signal at copper and/or fiber interface.
TECHNICAL SPECIFICATIONS
Standards Emissions: CISPR A
T1/E1 Physical Layer: ITU-T, ANSI, AT&T, ETSI
Dimensions 2.9" x 4.8" x 1.4" Weight 8 oz (approximate) Power Consumption 5 watts
Environment Typical Operating Temperature*: 0°
to 50°C (32° to 122°F )
Storage Temperature: -20°
to 85°C (-4° to 185°F)
Humidity 10-90%, non condensing Altitude 0-10,000 feet
Warranty Lifetime *Operating temperature range for this Slide-In-Module depends on the physical
characteristics and the installation configuration of the TRANSITION Networks chassis in which this Slide-In-Module will be installed. See the User’s Guide for the chassis in which this Slide-In-Module will be installed for a discussion of temperature-related installation constraints.
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA Model: CSDTF10xx Series Copper-to-Fiber Media Converter Part Number: CSDTF1011-100, CSDTF1012-100, CSDTF1013-100,
CSDTF1022-100
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the CSDTF10xx to which this declaration refers is in
conformity with the following standards. EN 55022:1994; EN 55024:1998; FCC Part 15 Class A; EN 60950 A4:1997; UL 1950
I, the undersigned, hereby declare that the equipment specified above conforms to the
above Directive(s) and Standard(s).
_January 8, 2001_____
Stephen Anderson, Vice-President of Engineering Date
T1/E1 Network Extension
Media Conversion Center
PWR
10BASE-T
DB-9
Power
LKC
1
In Use
Power
2
In Use
INPORT
RESET
INIT
12C
OUTPORT
PWR
TX
12C-1TERM
RX
LNK
MCCM10
MGMT MASTER
PWR
SPD
FLNK
FRX
SPD
PWR
LKF
FRX
RXF
CRX
CLNK
CRX
LKC
RXC
TX
TX
TX
100BASE-FX
100BASE-FX
10BASE-FL
RX
RX
10BASE-T
RX
CFETF100
CETTF100
SPD
FRX
PWR
PWR
SPD
FLNK
FLNK
FRX
CRX
CLNK
CRX
CLNK
TX
TX
10/100SX
10/100SX
RX
10/100TX
RX
CFETF110
10/100TX
Media Conversion Center
10BASE-T
Power
1
In Use
Power
2
In Use
INPORT
OUTPORT
MGMT MASTER
PWR
SPD
FLNK
FRX
CRX
CLNK
TX
100BASE-FX
RX
PWR
PWR
SPD
PWR
PWR
LKF
DB-9
RXF
LKC
RXC
TX
10BASE-FL
RESET
INIT
RX
12C
PWR
TX
10BASE-T
12C-1TERM
RX
LNK
MCCM10
CETTF100
SPD
FLNK
FRX
LKC
FLNK
FRX
CLNK
CRX
CRX
CLNK
TX
100BASE-FX
TX
10/100SX
RX
RX
10/100TX
CFETF100
CFETF110
PWR
SPD
FLNK
FRX
CRX
CLNK
TX
100BASE-FX
RX
SPD
FRX
CRX
TX
10/100SX
RX
10/100TX
CSU
CABLE SPECIFICATIONS (continued)
Twisted-Pair Copper Cable
Twisted pair connection requires two active pairs. The two active pairs in a T1/E1 network are pins 1 & 2 and pins 4 & 5. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins.
Category 3 or better twisted-pair copper wire is required. Either shielded twisted-pair (STP) or unshielded twisted-pair (UTP) can be used.
T1:
Gauge 24 to 22 AWG Attenuation 2.6 dB/100 meters @ 1.0 MHz Differential Characteristic Impedance 100 ±10%
E1:
Gauge 24 to 22 AWG Attenuation 2.6 dB/100 meters @ 1.0 MHz Differential Characteristic Impedance 120 ±10%
Dry-Contact Relay
RJ-45 dry-contact relay opens if power, signal detect/copper or signal detect/fiber are lost.
Operational rating on pins 3 and 6: 0-30VDC maximum 1A
Switch-Selectable Configurations
T1 COPPER RJ-45
Configured as either "long haul" or short haul on 100 ohm cable, with a variety of selectable distance settings.
E1 COPPER RJ-45
Configured as either "long haul" or short haul on 120 ohm cable.
STRAIGHT-THROUGH/CROSSOVER RJ-45
Allows straight-through cable to be used where crossover-configuration cable is required.
Switch-Selectable Functions
LOOPBACK TEST FUNCTION
A loopback switch facilitates installation and network debug procedures. The path for the CSDTF10xx loopback is shown:
TRANSMIT ALL ONES FUNCTION
A selectable Transmit All Ones switch on the fiber interface and on the twisted-pair interface allows for insertion of an all ones pattern on that interface when signal detect is lost, which creates an alarm condition at the equipment connected to the interface.
Relay
3
6
RJ-45
TP
Fiber
TP
INSTALLATION
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when setting switch and when installing Media Converter Slide-in­Module in the Media Conversion Center. Failure to observe this caution could result in damage to, and subsequent failure of, the Media Converter Slide-in­Module.
Set Loopback Test Switch
NOTE: The Loopback Test switch, located on Media Converter Slide-in­Module front panel, allows the network administrator to enable a loopback test for installation and network debug procedures.
Use small flatblade screwdriver or similar device to set recessed switches. Refer to drawing for switch locations.
Set 3-Position Jumper
NOTE: Jumper is located on Media Converter Slide-in-Module circuit board. Use small needle-nosed pliers or similar device to set
jumper. Refer to drawing for jumper positions. HARDWARE Converter mode is determined by
4-position switch settings below. SOFTWARE Converter mode is determined by most-
recently-saved on-board microprocessor settings.
Set MDI/MDI-X Switch
NOTE: The MDI/MDI-X switch, located on Media Converter Slide-in-Module circuit board, allows the network administrator to use straight-through cable in installations where crossover-configuration cable is required.
Use small flatblade screwdriver or similar device to set recessed switches. Refer to drawing for switch settings.
Set 8-Position Switch
NOTE: The eight-position switch, located on Media Converter Slide-in­Module circuit board, allows the network administrator to configure the media converter for network conditions.
Use small flatblade screwdriver or similar device to set recessed switches for site installation. Refer to drawings at right for eight-position switch settings.
CABLE SPECIFICATIONS
Fiber Cable
Bit error rate: 10-9
MULTIMODE
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber
Optional: 100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber CSDTF1011-100 850 nM Fiber Optic Transmitter Power: min: -14.0 dBm max: -12.0 dBm Fiber Optic Receiver Sensitivity: min: -25.0 dBm max: -12.0 dBm Typical Maximum Cable Distance*: 2 kilometers CSDTF1013-100 850 nM Fiber-optic Transmitter Power: min: -14.0 dBm max: -12.0 dBm Fiber-optic Receiver Sensitivity: min: -25.0 dBm max: -12.0 dBm Typical Maximum Cable Distance*: 2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended: 9 µm singlemode fiber CSDTF1012-100 1300 nM Fiber-optic Transmitter Power: min: -21.0 dBm max: -14.0 dBm Fiber-optic Receiver Sensitivity: min: -25.0 dBm max: -14.0 dBm Typical Maximum Cable Distance*: 8 kilometers CSDTF1014-100 1300 nM Fiber-optic Transmitter Power: min: -21.0 dBm max: -14.0 dBm Fiber-optic Receiver Sensitivity: min: -27.0 dBm max: -14.0 dBm Typical Maximum Cable Distance*: 8 kilometers CSDTF1015-100 (long haul) 1300 nM Fiber-optic Transmitter Power: min: -15.0 dBm max: -5.0 dBm Fiber-optic Receiver Sensitivity: min: -27.0 dBm max: -14.0 dBm Typical Maximum Cable Distance*: 15 kilometers CSDTF1022-100 (long haul) 1300 nM Fiber-optic Transmitter Power: min: -15.0 dBm max: -5.0 dBm Fiber-optic Receiver Sensitivity: min: -25.0 dBm max: -14.0 dBm Typical Maximum Cable Distance*: 15 kilometers
*Actual distance dependent upon physical characteristics of network installation.
Loop
H
HARDWARE MODE
H
SOFTWARE MODE
Twisted Pair #1
1 2
RTIP
RRING
MDI
TTIP
TRING
Twisted Pair #1
1 2
RTIP
RRING
MDI-X
RTIP
RRING
S
S
Twisted Pair #2
TTIP
4 5
TRING
Connectors for unlike devices
RTIP
RRING
Twisted Pair #2
TTIP
4 5
TRING
Connectors for like devices
TTIP
TRING
FAULT ISOLATION and CORRECTION
If the media converter fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action:
1. Is the P(o)W(e)R LED on the media converter illuminated? NO
Is the media converter inserted properly into the chassis?
Is the power cord properly installed in the chassis and at the
external power source?
Does the external power source provide power?
Contact Technical Support: (800) 260-1312.
YES
Proceed to step 2.
2. Is the SDF (Signal Detect/Fiber) LED illuminated? NO
Check fiber cables for proper connection.
Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other media converter.
Contact Technical Support: (800) 260-1312.
YES
Proceed to step 3.
3. Is the SDC (Signal Detect/Copper) LED illuminated? NO
Check twisted pair cables for proper connection.
Check RJ-45 Pinning Switch for correct twisted pair cable
configuration.
Check integrity of device attached to media converter by twisted-
pair cable.
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.
YES
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.
NOTE: T1 must be selected (
LEFT
SWITCH SET
#4 UP) for
RIGHT
SWITCH SET
to have any effect.
If E1 is selected (
LEFT SWITCH SET
#4 DOWN), RIGHT SWITCH SET
is
ignored and the default is E1
3.0V 120cable. If T1 and short haul are
selected (
LEFT SWITCH SET
#3
UP, #4 UP), but
RIGHT SWITCH
SET
is not set to a valid short haul value, the short haul default is DSX-1 0-133 cable.
If T1 and long haul are selected (
LEFT SWITCH SET
#3
DOWN, #4 UP), but
RIGHT
SWITCH SET
is not set to a valid long haul value, the long haul default is 0db 100cable.
KEY
= UP
= DOWN
RIGHT SWITCH SET
1 2 3 4
toward chassis
1 2 3 4
toward network connectors
LONG HAUL Switch Settings*
1 2 3 4
-22.5db
12
100 ohm cable
LEFT SWITCH SET
toward chassis
NETWORK Switch Settings
1 2 3 4
12
12
12
12
1 2 3 4
1 2 3 4
toward network connectors
Transmit All Ones onto Fiber on loss of TP Carrier Detect
UP= Enabled
Transmit All Ones onto TP on loss of FiberCarrier Detect
UP= Enabled
Long Haul/Short Haul (T1 only)
UP= Short Haul
T1/E1 Selection
UP= T1
SHORT HAUL Switch Settings*
1 2 3 4
DSX-1 533'-655'
12
12
12
100 ohm cable
DSX-1 399-533 100 ohm cable
DSX-1 266-399 100 ohm cable
-15db
12
100 ohm cable
-7.5db
12
100 ohm cable
0db
12
100 ohm cable
*Right switch set #4 not used
DSX-1 133'-266'
12
100 ohm cable
DSX-1 1 0-133
12
and ANSI T1.403 100 ohm cable
DSX-1 6.0V
12
100 ohm cable
*Right switch set #4 not used
INSTALLATION
(continued)
Install Slide-In-Module in PointSystem™Chassis
CAUTION: Any Slide-in-Module installation slot in which a Media Converter Slide-in-Module is NOT installed MUST have a protective plate instead. Failure to observe this caution will void Class A and/or Class B compliance.
NOTE: Install Media Converter Slide-in-Modules in any slot, in any order.
1. Carefully slide Media Converter Slide-in-Module into installation slot, aligning Media Converter Slide-in-Module with installation guides.
NOTE: Ensure that Slide-in-Module is firmly seated against backplane.
2. Secure Slide-in-Module by securing panel fastener screw (attached to Slide-in-Module) to chassis front.
3. Install protective plate at EVERY Slide-in-Module installation slot in which a Media Converter Slide-in-Module is not installed by securing attached protective plate panel fastener screw to chassis front.
Install Cable
COPPER
T1 100 OHM (RJ-45 CONNECTOR)
1. Locate or build twisted-pair cables that are compliant with
specifications on page 10, with RJ-45 plug connectors at both ends.
2. Ensure that MDI/MDI-X switch is set according to network
conditions.
3. Connect RJ-45 plug connector at one end of cable to media
converter RJ-45 jack connector.
4. Connect RJ-45 plug connector at other end of cable to network
equipment.
FIBER
1. Locate or build fiber cables that are compliant with specifications
on page 9, with male two-stranded TX to RX connectors installed at both ends.
2. Connect cable with connector installed at TX location on media
converter to RX location on attached device.
3. Connect cable with connector installed at RX location on media
converter to TX location on attached device.
Power the Slide-In-Module
NOTE: The Slide-In-Module is powered through the Conversion
Center
.
OPERATION
After installation, the media converter should function without operator intervention.
Status LEDs
Use the status LEDs to monitor media converter operation in the network. SDC Signal Detect/Copper - Steady LED
indicates twisted-pair copper link is up. Flashing LED (once/second) indicates
transmitting on link if other link is down. Flashing LED (5 times/second) indicates All
Ones detected on Link.
SDF Signal Detect/Fiber - Steady LED indicates fiber link is up.
Flashing LED (once/second) indicates transmitting on link if other link is down.
Flashing LED (5 times/second) indicates All Ones detected on Link.
P(o)W(e)R Steady green LED indicates connection to external AC power.
Using SNMP*
Use SNMP at an attached terminal or at a remote location to:
Monitor media converter by monitoring:
Media Converter Power Fiber Link Status Copper Link Status Hardware Switch settings AIS detected on Fiber AIS detected on Copper
Enter network commands that:
Enable/disable Loop-back on Fiber Enable/disable Transmit All Ones on Fiber when Copper is down Enable/disable Transmit All Ones on Copper when Fiber is down Power Down Media Converter.
*See the on-line documentation that comes with TRANSITION Networks
FocalPoint
software for applicable commands and usage.
TX
RX
TX
RX
SDC
SDF
PWR
LOOP